HomeMy WebLinkAboutScotland_Well Abandonment_20240119 I WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS I. Matthew Steele 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of 4548 A wells abandoned: f NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): 6.48 (gal.) I. , Geological Resources, Inc. FOR WATER SUPPLY WELLS ONLY: Company Name 7c.Type of disinfectant used: I' 2.Well Construction Permit#: I List all applicable well construction permits(i.e.UIC,County,State,Variance,etc.)if known . 7d.Amount of disinfectant used: 3.Well use(check well use): t Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public 0 Neat Cement Grout ! U Bentonite Chips or Pellets 0 Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) 0 Sand Cement Grout i 0 Dry Clay ❑lndustrial/Commercial ❑Residential Water Supply(shared) IN Concrete Grout . . 0 Drill Cuttings 0 Irrigation 0 Specialty Grout 1 0 Gravel Non-Water Supply Well: 0 Bentonite Slurry i 0 Other(explain under 7g) U Monitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑GroundwaterRemediation 200 lbs of Bentonite ❑Aquifer Storage and Recovery 0 Salinity Barrier ❑Aquifer Test ❑StormwaterDrainage 200 lb concrete ❑Experimental Technology 0 Subsidence Control 7g.Provide a brief description of the abandonment procedure: oGeothermal(Closed Loop) OTracer Pour I, 0 Geothermal(Heating/Cooling Return) 0 Other(explain under 7g) i, 4.Date well(s)abandoned: 08/17/2023 i 5a.Well location: I' Breeden's 66 00-0-0000000347 - �"'� Ey.-v :i3,-)G Facility/Owner Name Facility ID#(if applicable) ertif�--rati ^' 22900 Aberdeen Road, Laurinburg, NC ;: 08/22/2023 Physical Address,City,and Zip Signature of Certified Well Contractor'o:':.i r:wner Date Scotland 0203-14 010-3401 By signing this form, I hereby certify that the well(s) was (were) abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field,one lat/long is sufficient) 9.Site diagram or additional well details: 34.865101 N 79.455527 W You may use the back of this edge to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. i CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction record(s)if available.For multiple injection or non-water supply wells I ONLY with the sa`meconstrAu'ction/abandonment,you can submit one form. 10a. For All Wells: Submit this;form within 30 days of completion of well A 6a.Well ID#: V V S V V—1 abandonment to the following: I Division of Water Resources,Information Processing Unit, 6b.Total well depth: 77.30 -(ft.) 1617 Mail Serviced Center,Raleigh,NC 27699-1617 ' lOb.For Injection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter:4 (in.) above, also submit one copy of!this form within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface: 37.52 (ft.) Division of Water Resources,Underground Injection Control Program, 1636 Mail Service�,Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): n/a (ft,) 10c.For Water Supply&Iniec ion Wells: In addition to sending the form to the address(es)above,also submit orie copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6f.Inner casing/tubing length(if known): unknown (ft.) abandoned. 6g.Screen length(if known): unknown (ft.) ' Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016 WELL ABANDONMENT RECORD For Internal Use ONLY: is 1.Well Contractor Information: WELL ABANDONMENT DETAILS Matthew Steele 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of 4548 A wells abandoned: NC WellContractor Certification Number 7b.Approximate volume of water remaining in well(s): 1.86 (gal.) I' i Geological Resources, Inc. FOR WATER SUPPLY WELLS ONLY: Company Name A' l� 7c.Type of disinfectant used: 2.Well Construction Permit#: N/„ List all applicable well construction permits(i.e.UIC,County,State, Variance,etc.)if known r 7d.Amount of disinfectant used: 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural OMunicipal/Public 0 Neat Cement Grout I Bentonite Chips or Pellets 0 Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) 0 Sand Cement Grout 0 Dry Clay , ❑lndustrial/Commercial •❑Residential Water Supply(shared) I Concrete Grout j 0 Drill Cuttings ❑Irrigation 0 Specialty Grout ! 0 Gravel Non-Water Supply Well: 0 Bentonite Slurry 0 Other(explain under 7g) IMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑Groundwater Remediation 20 lbs of Bentonite ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑Stormwater Drainage 15 lb concrete ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: OGeothermal(Closed Loop) ❑Tracer OGeothermal(Heating/Cooling Return) ❑Other(explain under 7g) Pour r a1.v.,9 l '� 'v it 1 ' , ; - 4.Date well(s) 08/17/2023 abandoned: JAI N 1 9 mn 5a.Well location: 00-0-0000009375 lt1 yt. • Laurinburg Food Mart ` ;:; .`.; ;;' • - Facility/Owner Name Facility ID#(if applicable) 8.Certification: II �a 1201 Produce Market Road, Laurinburg, NC i 8/18/23 Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date Scotland 1004-10-1073 By signing this form,I hereby certt&that the well(s) was (were) abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C,.0100 or 2C.0200 Well Construction Standards and that a copy of this record has;been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field,one 1at/long is sufficient) 9.Site diagram or additional well details: 34.790327 N 79.445983 `,l, You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction record(s)if available.For multiple injection or non-water supply wells ONLY with the same construction/abandonment,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#: M V A V-2 abandonment to the following: 1 ,t Division of Water Resources,Information Processing Unit, 6b.Total well depth: 24.65 (ft.) 1617 Mail Service,Center,Raleigh,NC 27699-1617 10b.For Infection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: 6 (in,) above, also submit one copy of jthis form within 30 days of completion of well abandonment to the following: I I i 13.24 Division of Water Resources,Underground Injection Control Program, 6d.Water level below ground surface.: (ft.) i 1636 Mail Service'Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): n/a (ft) 10c.For Water Supply&Infection Wells: In addition to sending the form to the address(es)above,also submit ode copy of this form within 30 days of completion of well abandonment to the county health department of the county where I 6f.Inner casing/tubing length(if known): 15 (ft,) abandoned. 6g.Screen length(if known): 1 0 -- (ft.) : Form GW-30 • North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016