Loading...
HomeMy WebLinkAbout030033_Compliance Evaluation Inspection_20230315 Division of Water Resources Facility Number - � Division of Soil and Water Conservation 0 Other Agency Type of Visit: Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: 15 Arrival Time: Departure Time: County: r) Region: Farm Name: Qd t)ar Owner Email: Owner Name: A+VJ 6 0� Phone: Mailing Address: Ch. Physical Address: 3 (`n")L czy Facility Contact: �/`/� i L� --Wo p Title: Phone: Onsite Representative: Integrator: Certified Operator: `z Certification Number: Back-up Operator: Certification Number: Location of Farm: Latitude:J2ji�l� 16 J I' Longitude: �� r Design Current Design Current Design Current Swine Capacity Pop. Wet Poultry Capacity Pop. Cattle Capacity Pop. Wean to Finish Layer Dairy Cow Wean to Feeder HNon-Layer Dairy Calf Feeder to Finish Dairy Heifer Farrow to Wean Design Current Dry Cow Farrow to Feeder Dry Poultry Capacity Pop. Non-Dairy Farrow to Finish Layers Beef Stocker Gilts Non-Layers Beef Feeder . Boars Pullets Beef Brood Cow Turkeys Other Turkey Poults Other Discharp,es and Stream Impacts 1. Is any discharge observed from any part of the operation? ❑ Yes �No ❑ NA ❑ NE Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? ❑ Yes ❑ No ❑ NA ❑ NE b. Did the discharge reach waters of the State'? (If yes,notify DWR) ❑ Yes ❑ No ❑ NA ❑ NE c. What is the estimated volume that reached waters of the State(gallons)? d. Does the discharge bypass the waste management system?(If yes,notify DWR) ❑ Yes No ❑ NA ❑ NE 2. Is there evidence of a past discharge from any part of the operation? ❑ Yes [Z No ❑ NA ❑ NE 3. Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Yes No ❑ NA ❑ NE of the State other than from a discharge? Page 1 of 3 511212020 Continued Facility Number: - Date of Inspection: Waste Collection&Treatment 4. Is storage capacity(structural plus storm storage plus heavy rainfall)less than adequate? ❑ Yes No ❑ NA ❑ NE a.If yes, is waste level into the structural freeboard? ❑ Yes No ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: _ Spillway?: ✓ Designed Freeboard(in): Observed Freeboard(in): 'f' 5.Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes XNo ❑ NA ❑ NE (i.e., large trees,severe erosion,seepage,etc.) �' "�v 1_U.k1a1."C , 6.Are there structures on-site which are not properly�addressed and/or managed through a ❑ Yes 4 No ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes,and the situation poses an immediate public health or environmental threat,notify DWR 7.Do any of the structures need maintenance or improvement? (y�('V�j�(�IAC%E j- Yes [:] No ❑ NA ❑ NE 8.Do any of the structures lack adequate markers as required by the permit? J Yes ❑ No ❑ NA ❑ NE (not applicable to roofed pits,dry stacks,and/or wet stacks) 9.Does any part of the waste management system other than the waste structures require [:] Yes [%"No ❑ NA ❑ NE maintenance or improvement? Waste An»lication 10.Are there any required buffers,setbacks,or compliance alternatives that need ❑ Yes No ❑ NA ❑ NE maintenance or improvement? 11. Is there evidence of incorrect land application?If yes,check the appropriate box below. ❑ Yes (�] No ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals(Cu,Zn,etc. ❑ PAN ❑ PAN> 10%or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12.Crop Type(s): � Cl(;� I 13. Soil Type(s): 14. Do the receiving crops differ from those designated in the CAWMP? ] Yes ❑ No ❑ NA ❑ NE 15.Does the receiving crop and/or land application site need improvement? ❑ Yes No ❑ NA ❑ NE 16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes No ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes '" No ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes Ix No ❑ NA ❑ NE Required Records& Documents 19. Did the facility fail to have the Certificate of Coverage&Permit readily available? ❑ Yes No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available?If yes,check ❑ Yes No ❑ NA ❑ NE the appropriate box. ❑WUP ❑Checklists ❑Design ❑Maps ❑ Lease Agreements ❑Other: 21.Does record keeping need improvement?_Uyes,o1wel 1' ❑ Yes No NA ❑ NE Waste Application Weekly Freeboard lysis DSoil-Anal:)i4s ❑-W4i rs �Weather Code Rainfall Stocking Crop Yield D44 ".- :�� 0 Monthly and 1"Rainfall Inspections E °•� 22.Did the facility fail to install and maintain a rain gauge? ❑ Yes No ❑ NA ❑ NE 23. If selected,did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ❑ No K] NA ❑ NE Page 2 of 3 511212020 Continued Facility Number: - Date of Inspection: 24.Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes DqNo 0 NA ❑ NE 25. Is the facility out of compliance with permit conditions related to sludge? If yes,check ❑ Yes [:] No NA ❑ NE the appropriate box(es)below. ❑Failure to complete annual sludge survey ❑Failure to develop a POA for sludge levels ❑Non-compliant sludge levels in any lagoon List structure(s)and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ Yes No ❑ NA ❑ NE 27.Did the facility fail to secure a phosphorus loss assessments(PLAT)certification? ❑ Yes No ❑ NA ❑ NE Other Issues 28.Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes No ❑ NA ❑ NE and report mortality rates that were higher than normal? 29.At the time of the inspection did the facility pose an odor or air quality concern? ❑ Yes No ❑ NA ❑ NE If yes,contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes Z No ❑NA ❑NE permit?(i.e.,discharge,freeboard problems,over-application) 31. Do subsurface tile drains exist at the facility? If yes,check the appropriate box below. ❑ Yes No ❑ NA ❑NE ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 0 Yes [;'No ❑ NA ❑ NE 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on-site representative? ❑ Yes RNo ❑ NA ❑NE 34. Does the facility require a follow-up visit by the same agency? ❑ Yes 4No ❑ NA ❑ NE Comments(refer to question ft Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain situations(use additional pages as necessary). Sol (S , �khcu\-IL I vv'l 41 A e csr-, . \pin u(J� +2S ? �� G v f in c�� A d pomo::5rs(cvm oAc� ed Reviewer/Inspector Name: ��_ (.�I tc.� La - Phone: Reviewer/Inspector Signature: "—'—"— ' " Date: Page 3 of 3 511212020