Loading...
HomeMy WebLinkAboutGW1--06772_Well Construction - GW1_20230501WELL CONSTRUCTION RECORD This form can be used for single or mutiple wells 1. Well Contractor Information: Well Contractor Name NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction pertmits (ie County, State, Variance, etc. 3. Well Use: 4. Date Well(s) Completed:Well ID# 5a. Well Location: 5b. Latitude and Longitude degrees/minutes/seconds or decimal degrees: List all applicable well construction pertmits (ie County, State, Variance, etc. (If well field, one lat/long is sufficient.) N W 6. Is (are) the well(s): 7. Is this a repair to an existing well: 8. Number of wells constructed: 9. Total well depth below land surface: 10. Static water level below top of casing: 11. Borehole diameter: 12. Well construction method: FOR WATER SUPPLY WELLS ONLY: If this is a repair, fill out known well construction information and explain the nature of the repair under # 21 remarks section or on the back of this form. For multiple injection or non-water wells ONLY with the same construction, you can submit one form. For multiple wells list all depths if different (example- 3@ 200' and 2 @ 100') If water level is above casing, use "+" (i.e. auger, rotary, cable, direct push, etc.) 13a. Yield (gpm): Method of test: 13b. Disinfection type: Amount: Form GW-1 North Carolina Department of Environment and Natural Resources - Division of Water Quality Revised 2/22/16 Facility/Owner Name Facility ID (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) (ft.) (ft.) (in.) For Internal Use ONLY: 14. WATER ZONES FROM TO DESCRIPTION ft. ft. ft. ft. 15. OUTER CASING (for multi-cased wells) OR LINER (if applicable) FROM TO DIAMETER THICKNESS MATERIAL ft. ft. ft. ft. in. in. 16. INNER CASING OR TUBING (geothermal closed loop) FROM TO DIAMETER THICKNESS MATERIAL ft. ft. ft. ft. in. in. 17. SCREEN FROM TO DIAMETER THICKNESS SLOT SIZE MATERIAL ft. ft. ft. ft. in. in. 18. GROUT FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT ft. ft. ft. ft. ft.ft. 19. SAND/GRAVEL PACK (if applicable) FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT ft. ft. ft. ft. ft.ft. 20. DRILLING LOG (attach additional sheets if necessary) FROM TO DESCRIPTION (color, hardness, soil/rock type, grain size, etc) ft. ft. ft. ft. ft.ft. ft.ft. ft.ft. ft.ft. ft.ft. 21. REMARKS 22. Certification: Signature of Certified Well Contractor Date By signing this form, I hereby certify that the well(s) was (were) constructed in accordance with 15A NCAC 02C .0100 or 15A NCAC 02C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 23. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well construction details. You may also attach additional pages if necessary. SUMITTAL INSTRUCTIONS 24a. For All Wells:Submit this form within 30 days of completion of well construction to the following: Division of Water Quality, Information Procession Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 24b. For Injection Wells:In addtion to sending the form to the address in 24a above, also submit a copy of this form within 30 days of completion of well construction to the following: Division of Water Quality, Undergroun Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 24c. For Water Supply Injection Wells:In addtion to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well construction to the county health department of the county where constructed. Lake Valley Well Co., Inc 2269-A Chauncey Leggett 181979 Residential 3/13/2023 173 E Silverado CT, Kenly, 27542 Lot 8 Tyson's Corner Johnston HTH 35.670628 -78.246087 Blue Dog Residential 181 Air25 Rotary air Water zones at 30ft to 35ft, 43ft to 46ft, 90ft to 95ft and 165ft 3/13/2023 1 Permanent 6 No 10 12 OZ Page 1 Black Topsoil 20 Gray Clay 122 Cream Clay 1512 Gray Shale 2015 Light Gray Shale 6520 Gray Rock 18165 0 23 PVC plastic6.25 SDR21 0 23 Bentonite slurry Tremie Pipe12 OUTER CASING (for multi-cased wells) OR LINER (if applicable) FROM TO DIAMETER THICKNESS MATERIAL INNER CASING OR TUBING (geothermal closed loop) FROM TO DIAMETER THICKNESS MATERIAL SCREEN FROM TO DIAMETER THICKNESS SLOT SIZE MATERIAL GROUT FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT SAND/GRAVEL PACK (if applicable) FROM TO MATERIAL EMPLACEMENT METHOD & AMOUN DRILLING LOG (attach additional sheets if necessary) FROM TO DESCRIPTION (color, hardness, soil/rock type, grain size, etc) WATER ZONES FROM TO DESCRIPTION Page 2 Black Topsoil 20 Gray Clay 122 Cream Clay 1512 Gray Shale 2015 Light Gray Shale 6520 Gray Rock 18165 0 23 PVC plastic6.25 SDR21 0 23 Bentonite slurry Tremie Pipe12