HomeMy WebLinkAboutSW6130202_Emails_20130214Patterson, Robert
From: Patterson, Robert
Sent: Thursday, February 14, 2013 1:54 PM
To: 'Luke Bugenske'
Cc: 'cburton@burtonengineering.com';'bill.allen@durbangroup.com';'darren.tuitt@durbangroup.com'
Subject: SW6130202 - E. Prospect - FDS - Add. Info. Req'st
Luke,
Just a few similar items with this other FDS also.
1. Original signature for the applicant
2. Verify/revise impervious area on page 3 of SWU-101. They vary from what's shown on the supplement form
and calculations.
3. Add sod to the bottom area around the sand bed.
4. The bypass is set to el. 198.0', but there is an emergency spillway below that at el. 197.5'. The spillway either
should be raised or provide calculations to show the WQVadj is available at 197.5 instead of 198.0.
This add. info. must be submitted for both this project and SW6130201 by March 16, 2013, or they may be returned as
incomplete. Please let me know if you have any questions. Thanks.
Robert D. Patterson, PE
Environmental Engineer
NCDENR I DWQ I Stotinwater Permitting
1617 Mail Service Center, Raleigh, NC 27699-1617 Mail 1 512 N. Salisbury St, 91" Flour, Raleigh, NC 27604 I -oration tS P;m els
(919) 807-6375 Phone 1 (919) 807-6494 Fax I Robert. PattersonR]ncdenr.eov Email I htto://noital.nedenr.ore/web/Wohvs/su website
r31fclurc printing this snail, plri5c amsidcr your budget and the omronmcm.
E-mail correspondence to and from this address maybe subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is
exempt by statute or other regulation.
Patterson, Robert
From: Luke Bugenske ILukeB@burtonengineering.com]
Sent: Tuesday, February 26, 2013 8:13 AM '
To: Patterson, Robert
Subject: RE: SW6130202 - E. Prospect-FDS - Additional Information Request
Attachments: E. Prospect SWIM Application (page 3)-022613.pdf
Good morning Robert,
The Suppliment Form is accurate. I have adjusted page 3 of the SWU-101 form to reflect the accurate characteristics of
the drainage area.
Please let me know if you need anything else.
Luke J. Bugenske, PE
Burton Engineering Associates
5950 Fairview Road, Suite 100
Charlotte, NC 28210
(P) 704.553.8881
(F) 704.553.8860
From: Patterson, Robert [mailto:robert.oatterson(c ncdenr.gov]
Sent: Friday, February 22, 2013 1:07 PM
To: Luke Bugenske
Subject: SW6130202 - E. Prospect-FDS - Additional Information Request
Luke,
I just left you a voice mail about this as well.
The drainage area and impervious area numbers are still not consistent between the supplement form (and calcs) and
the table in SWU-101. The table below shows the differences. Please update these as needed and send it to me via
email. Everything else from the first add. info. request was addressed. Thanks.
SWU-101
Supp. Form
DA
149,236
44,866
Imp. A
135,582
36,480
Robert D. Patterson, PE
Environmental Engineer
NCDENR I DWQ I Stormwater Permitting
1617 Mail Service Center, Raleigh, NC 27699-1617 Mail 1 512 N. Salisbury St, 9th Floor, Raleigh, NC 27604 Location & Parcels
(919) 807-6375 Phone 1 (919) 807-6494 Fax I Robert. Patterso uncdenr.eov Email I htto://i)ortal.ncdenr.org/web/wo/ws/su Website
,A Before printing this email, please consider your budget and the environment.
E-mail correspondence to and from this address maybe subject to the North Carolina Public Records Law and maybe disclosed to third parties unless the content is
exempt by statute or other regulation.