Loading...
HomeMy WebLinkAboutSW6130202_Emails_20130214Patterson, Robert From: Patterson, Robert Sent: Thursday, February 14, 2013 1:54 PM To: 'Luke Bugenske' Cc: 'cburton@burtonengineering.com';'bill.allen@durbangroup.com';'darren.tuitt@durbangroup.com' Subject: SW6130202 - E. Prospect - FDS - Add. Info. Req'st Luke, Just a few similar items with this other FDS also. 1. Original signature for the applicant 2. Verify/revise impervious area on page 3 of SWU-101. They vary from what's shown on the supplement form and calculations. 3. Add sod to the bottom area around the sand bed. 4. The bypass is set to el. 198.0', but there is an emergency spillway below that at el. 197.5'. The spillway either should be raised or provide calculations to show the WQVadj is available at 197.5 instead of 198.0. This add. info. must be submitted for both this project and SW6130201 by March 16, 2013, or they may be returned as incomplete. Please let me know if you have any questions. Thanks. Robert D. Patterson, PE Environmental Engineer NCDENR I DWQ I Stotinwater Permitting 1617 Mail Service Center, Raleigh, NC 27699-1617 Mail 1 512 N. Salisbury St, 91" Flour, Raleigh, NC 27604 I -oration tS P;m els (919) 807-6375 Phone 1 (919) 807-6494 Fax I Robert. PattersonR]ncdenr.eov Email I htto://noital.nedenr.ore/web/Wohvs/su website r31fclurc printing this snail, plri5c amsidcr your budget and the omronmcm. E-mail correspondence to and from this address maybe subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. Patterson, Robert From: Luke Bugenske ILukeB@burtonengineering.com] Sent: Tuesday, February 26, 2013 8:13 AM ' To: Patterson, Robert Subject: RE: SW6130202 - E. Prospect-FDS - Additional Information Request Attachments: E. Prospect SWIM Application (page 3)-022613.pdf Good morning Robert, The Suppliment Form is accurate. I have adjusted page 3 of the SWU-101 form to reflect the accurate characteristics of the drainage area. Please let me know if you need anything else. Luke J. Bugenske, PE Burton Engineering Associates 5950 Fairview Road, Suite 100 Charlotte, NC 28210 (P) 704.553.8881 (F) 704.553.8860 From: Patterson, Robert [mailto:robert.oatterson(c ncdenr.gov] Sent: Friday, February 22, 2013 1:07 PM To: Luke Bugenske Subject: SW6130202 - E. Prospect-FDS - Additional Information Request Luke, I just left you a voice mail about this as well. The drainage area and impervious area numbers are still not consistent between the supplement form (and calcs) and the table in SWU-101. The table below shows the differences. Please update these as needed and send it to me via email. Everything else from the first add. info. request was addressed. Thanks. SWU-101 Supp. Form DA 149,236 44,866 Imp. A 135,582 36,480 Robert D. Patterson, PE Environmental Engineer NCDENR I DWQ I Stormwater Permitting 1617 Mail Service Center, Raleigh, NC 27699-1617 Mail 1 512 N. Salisbury St, 9th Floor, Raleigh, NC 27604 Location & Parcels (919) 807-6375 Phone 1 (919) 807-6494 Fax I Robert. Patterso uncdenr.eov Email I htto://i)ortal.ncdenr.org/web/wo/ws/su Website ,A Before printing this email, please consider your budget and the environment. E-mail correspondence to and from this address maybe subject to the North Carolina Public Records Law and maybe disclosed to third parties unless the content is exempt by statute or other regulation.