Loading...
HomeMy WebLinkAbout790003_Compliance Evaluation Inspection_20211202 0 Division of Water Resources ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 010010 Facility Status: Active Permit: AWC010010 ❑ Denied Access Inspection Type: Compliance Inspection Inactive Or Closed Date: Reason for Visit: Routine County: Alamance Region: Winston-Salem Date of Visit: 12/02/2021 Entry Time: 10:15 am Exit Time: 10:40 am Incident#: Farm Name: Triple W Farms Owner Email: hwoody273@bellsouth.net Owner: Harold Woody Phone: 336-213-8644 Mailing Address: 3545 E Greensboro Rd Snow Camp NC 27349 Physical Address: 3545 E Greensboro-Chapel Hill Hwy Snow Camp NC 27349 Facility Status: ❑ Compliant 0 Not Compliant Integrator: Location of Farm: Latitude: 35' 54' 15" Longitude: 79' 18'00" Take 87 south 13 miles to Dauls Exxon-turn right-go 1/2 miles to farm on right. Question Areas: Dischrge&Stream Impacts Waste Col, Stor, &Treat Waste Application Records and Documents Other Issues Certified Operator: George H Woody Operator Certification Number: 997975 Secondary OIC(s): On-Site Representative(s): Name Title Phone 24 hour contact name Harold Woody 336-213-8644 On-site representative Harold Woody 336-213-8644 Primary Inspector: Rebecca D Chandler Phone: 336-776-9705 Inspector Signature: Date: Secondary Inspector(s): Inspection Summary: Mr.Woody notified of inspection via text on11/22/21, text was read. He was not present and no records were available for review 6. Small uncovered concrete pit is still open 7. Small amount of leachate from drystand leaking out of bad concrete. Ditch has been repaired. 3. &9. Continued waste storage from old pushoff, no new wastes,wastes still within 100'of onsite well Page 1 of 5 Permit: AWC010010 Owner: Harold Woody Facility Number: 010010 Inspection Date: 12/02/21 Inspection Type: Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current promotions Cattle Cattle- Dairy Heifer 200 0 Cattle- Milk Cow 400 0 Total Design Capacity: 600 Total SSLW: 760,000 Waste Structures Effective Built Closed Designated Observed Type Identifier Date Date Date Freeboard Freeboard Dry Stack 02 04/23/2013 D1/23/2013 12.00 Waste Pit CONCRETE PIT 07/17/1995 Waste Pond 01 04/23/2013 D4/23/2013 57.00 60.00 Page 2 of 5 Permit: AWC010010 Owner: Harold Woody Facility Number: 010010 Inspection Date: 12/02/21 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ 0 ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ 0 ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ 0 ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ 0 ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ 0 ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the 0 ❑ ❑ ❑ State other than from a discharge? Waste Collection, Storage &Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ 0 ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ larc ❑ 0 ❑ ❑ trees, severe erosion, seepage, etc.)? 6. Are there structures on-site that are not properly addressed and/or managed through a 0 ❑ ❑ ❑ waste management or closure plan? 7. Do any of the structures need maintenance or improvement? 0 ❑ ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE ❑ 0 ❑ ❑ to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ ❑ ❑ maintenance or improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ ❑ ❑ maintenance or improvement? 11. Is there evidence of incorrect application? ❑ ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ Crop Type 1 Page 3 of 5 Permit: AWC010010 Owner: Harold Woody Facility Number: 010010 Inspection Date: 12/02/21 Inspection Type: Compliance Inspection Reason for Visit: Routine Waste Application Yes No NA NE Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Soil Type 2 Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste ❑ ❑ ❑ Management Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre ❑ ❑ ❑ determination? 17. Does the facility lack adequate acreage for land application? ❑ ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ ❑ ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ ❑ ❑ If yes, check the appropriate box below. WUP? ❑ Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? ❑ ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Stocking? ❑ Crop yields? ❑ Page 4 of 5 Permit: AWC010010 Owner: Harold Woody Facility Number: 010010 Inspection Date: 12/02/21 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No NA NE 120 Minute inspections? ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipmen ❑ ❑ 0 ❑ (NPDES only)? 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ❑ ❑ 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the ❑ ❑ 0 ❑ appropriate box(es) below: Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non-compliant sludge levels in any lagoon ❑ List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ 0 ❑ ❑ 27. Did the facility fail to secure a phosphorous loss assessment(PLAT) certification? ❑ ❑ ❑ Other Issues Yes No NA NE 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document ❑ ❑ 0 ❑ and report mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, ❑ 0 ❑ ❑ contact a regional Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit% ❑ ❑ ❑ (i.e., discharge, freeboard problems, over-application) 31. Do subsurface tile drains exist at the facility? ❑ ❑ 0 ❑ If yes, check the appropriate box below. Application Field ❑ Lagoon/Storage Pond ❑ Other ❑ If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or ❑ 0 ❑ ❑ CAW M P? 33. Did the Reviewer/Inspector fail to discuss review/inspection with on-site representative? ❑ 0 ❑ ❑ 34. Does the facility require a follow-up visit by same agency? 0 ❑ ❑ ❑ Page 5 of 5