Loading...
HomeMy WebLinkAbout760009_Compliance Evaluation Inspection_20191218 I Division of Water Resources I Facility Number - C 0 Division of Soil and Water( ervation 1 p Other Agency I O Q Type of Visit: Compliance Inspection 0 Operation Review O Structure Evaluation O Technical Assistance Reason for Visit: Routine O Complaint O Follow-up O Referral O Emergency O Other O Denied Access Date of Visit: Arrival Time: '�, Departure Time: County: Region: V ,J r✓v Farm Name: tKl(A ra ryvs Owner Email: Owner Name: T� Q �{ L1- Phone: O'd Mailing Address: U (b[ l Oq o Physical Address: �� �j� 'rd� Lac(�� fi�- t , �U�l S U y— Facility Contact: l L ' (�� Title: Phone: Onsite Representative: Integrator: Certified Operator: 1L —)-,e Certification Number: Back-up Operator: Certification Number: Location of Farm: Latitude: Longitude: Design Current Design Current Design Current Swine Capacity Pop. Wet Poultry Capacity Pop. Cattle Capacity Pop. Wean to Finish La er Dairy Cow Wean to Feeder I INon-Layer I I Dairy Calf Feeder to Finish 3 Dairy Heifer Farrow to Wean Design Current Dry Cow Farrow to Feeder Dry Poultry Capacity Pop. Non-Dairy Farrow to Finish Layers Beef Stocker Gilts Non-Layers Beef Feeder Boars Pullets Beef Brood Cow Turkeys Other Turkey Poults lot el Other Discharus and Stream Impacts 1. Is any discharge observed from any part of the operation? ❑ Yes ❑ No ❑ NA ❑ N F? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? ❑ Yes ❑ No ❑ NA ❑ NE b. Did the discharge reach waters of the State?(If yes,notify DWR) ❑ Yes ❑ No ❑ NA ❑ NE c. What is the estimated volume that reached waters of the State(gallons)? d. Does the discharge bypass the waste management system?(If yes,notify DWR) ❑ Yes ❑ No ❑ NA ❑ NE 2. Is there evidence of a past discharge from any part of the operation? ❑ Yes ❑ No ❑ NA ❑ NE 3. Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Yes ❑ No ❑ NA ❑ NE of the State other than from a discharge? Page I of 3 21412015 Continued Facility Number: jDate of Inspection: Waste Collection&Treatment 4. Is storage capacity(structural plus storm storage plus heavy rainfall)less than adequate? ❑ Yes ❑ No ❑ NA ❑ NE a. If yes,is waste level into the structural freeboard? ❑ Yes ❑ No ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Spillway?: Designed Freeboard(in): Observed Freeboard(in): 1 5.Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes ❑ No ❑ NA ❑ NE (i.e.,large trees,severe erosion,seepage,etc.) 6.Are there structures on-site which are not properly addressed and/or managed through a ❑ Yes ❑ No ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes,and the situation poses an immediate public health or environmental threat,notify DWR 7.Do any of the structures need maintenance or improvement? ❑ Yes ❑ No ❑ NA ❑ NE 8.Do any of the structures lack adequate markers as required by the permit? ❑ Yes ❑ No ❑ NA ❑ NE (not applicable to roofed pits,dry stacks,and/or wet stacks) 9.Does any part of the waste management system other than the waste structures require ❑ Yes [:] No ❑ NA ❑ NE maintenance or improvement? Waste Application 10.Are there any required buffers,setbacks,or compliance alternatives that need ❑ Yes ❑ No ❑ NA ❑ NE maintenance or improvement? 11.Is there evidence of incorrect land application?If yes,check the appropriate box below. ❑ Yes ❑ No ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals(Cu,Zn,etc.) ❑ PAN ❑ PAN> 10%orJ 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12.Crop Type(s): Y I 13. Soil Type(s): i 14.Do the receiving crops differ from those designated in the CAWMP? ❑ Yes No ❑ NA ❑ NE 15.Does the receiving crop and/or land application site need improvement? ❑ Yes ❑ No ❑ NA ❑ NE 16.Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes ❑ No ❑ NA ❑ NE acres determination? 17.Does the facility lack adequate acreage for land application? ❑ Yes ❑ No ❑ NA ❑ NE 18.Is there a lack of properly operating waste application equipment? ❑ Yes ❑ No ❑ NA ❑ NE Required Records&Documents 19.Did the facility fail to have the Certificate of Coverage&Permit readily available? ❑ Yes No ❑ NA ❑ NE j i 20. Does the facility fail to have all components of the CAWMP readily available?If yes,check ❑ Yes [ No ❑ NA ❑ NE the appropriate box. ❑WUP ❑Checklists ❑Design ❑Maps [:] Lease Agreements ❑Other: 21.Does record keeping need improvement?If yes,check the appropriate box below ❑ Yes ❑ No ❑ NA ❑ NE j 1 Waste Application Weekly Freeboard Waste Analysis - oil Analysis ❑Waste Transfers Weather Code Rainfall Stocking Crop Yield 120 Minute Inspections [2Monthly and 1"Rainfall Inspections KSludge Survey 22. Did the facility fail to install and maintain a rain gauge? /\ ❑ Yes ❑ No ❑ NA ❑ NE 1 1 23.If selected,did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ❑ No ❑ NA ❑ NE a Page 2 of 3 21412015 Continued Facility Number: - Date of Inspection: 24. Did the facility fail to calibrate waste app. .ion equipment as required by the permit? ❑ Yes ❑ No ❑ NA ❑ NE 25. Is the facility out of compliance with permit conditions related to sludge? If yes,check Yes ❑ No ❑ NA ❑ NE the appropriate box(es)below. WN ❑Failure to complete annual sludge survey ❑Failure to develop a POA for sludge levels Non-compliant sludge levels in any lagoon r_yist structure(s)and date of first survey indicating non-compliance: At 26. Did the facility fail provide documentation of an actively certified operator in charge? ❑ Yes ❑ No ❑ NA ❑ NE 27. Did the facility fail to secure a phosphorus loss assessments(PLAT)certification? ❑ Yes ❑ No ❑ NA ❑ NE Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes ❑ No ❑ NA ❑ NE and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? 0 Yes ❑ No ❑ NA ❑ NE If yes,contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes ❑ No ❑ NA ❑ NE permit?(i.e.,discharge,freeboard problems,over-application) 31. Do subsurface tile drains exist at the facility?If yes,check the appropriate box below. ❑ Yes ❑ No ❑ NA ❑ NE ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? ❑ Yes ❑ No ❑ NA ❑ NE 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on-site representative? ❑ Yes ❑ No ❑ NA ❑ NE 34. Does the facility require a follow-up visit by the same agency? ❑ Yes ❑ No ❑ NA ❑ NE Comments(refer to question#):Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain situations(use additional pages as necessary). So Cup p t�ca4- 20�U Coy O--WLA CG- 7 1 bo•yv �d\ ve u, J V PC t e i 1 ft lb l ( -51 t+ I vi q I l el Reviewer/Inspector Name: Phone: Reviewer/Inspector Signature: Date: Page 3 of 3 21412015