HomeMy WebLinkAboutGaston_Well Abandonment_20230915 WELL ABANDONMENT RECORD For Intern aI Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS William J. Miller 7a.For Geoprobe/DPT or Closed-L oopi Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: f 2927A t 05 r s NC Well Contractor Certification Number 1 .,,r F D 7b.Approximate volume of water remaining in well(s): (gal.) Catlin Engineers & Scientists SEP 1 r 2023 FOR WATER SUPPLY WELLS 0NLY: e Company Name , 7c.Type of disinfectant used: 2.Well Construction Permit#: List all applicable well construction permits(i.e.UIC,County,Stale,Variance,etc.)if known 7d.Amount of disinfectant used: 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑Neat Cement Grout a Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay ❑Industrial/Commercial ❑Residential Water Supply(shared) ❑ Concrete Grout ❑ Drill Cuttings ❑Irrigation ❑ Specialty Grout ❑ Gravel Non-Water Supply Well: ❑ Bentonite Slurry a Other(explain under 7g) CMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑Groundwater Remediation Bentonite 50 Ibs ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑StormwaterDrainage Concrete 16.67lbs ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) Hydrated bentonite to 4, inches below land surface. Concrete used to bring ;opening to grade. All well 4.Date well(s)abandoned: 8/2/23 materials left in place. I 5a.Well location: Ralph G Sellers Jr 00-030142 Facility/Owner Name Facility ID#(ifapplicable) 8.Certification: 7152 Dallas Cherryville Hwy, Cherryville, NC 28021 8/4/2023 Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date Gaston County 3509492178 i By signing this forni, I hereby certify that the ivell(s) was (were) abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field,one lat/long is sufficient) 9.Site diagram or additional well details: - 35.373787 N -81.333959 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction record(s)ifavailable. For rnulliple injection or non-water supply wells ONLY with the sauce convlrnclion,abandaunenl,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#: MW-2 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 25 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b. For Injection Wells: hi addition-to sending the form to the address in l0a 6c.Borehole diameter: 8.25 (in) above, also submit one copy of thisi form within 30 days of completion of well abandonment to the following: I I 6d.Water level below ground surface: 16.62 (ft) Division of Water Resources,Underground Injection Control Program, 1636 Mail Service Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): NA (ft.) 10c.For Water Supply&IniectioniW,ells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county'health department of the county where 6f,Inner casing/tubing length(if known): 10 (ft) abandoned. f 6g.Screen length(if known): 15 Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016 II`