Loading...
HomeMy WebLinkAboutSW6230606_Plansheet - Other_20230906 NEW 8X8X8 TEE AND 8" VALVE ' -i / 2" METER COORDINATE ANY NECESSARY SHUTOFF I No / GENERAL NOTES: UTILITY PLAN w � design, I • • _� � 2"X1.5" REDUCER OF EXISTING MAIN WITH HARNETT I —_ cUj f) COUNTY REGIONAL WATER DEPARTMENT 1 _ M I cr 2" TAPPING SLEEVE AND 2" VALVE 5'X5' ASPHALT PATCH 1. BASE INFORMATION IS FROM A SURVEY MAP ENTITLED "EXISTING I / = i CONDITIONS LOTS1-3 FALCON CREST SUBD, BBQ TWP." DATED cD 1-1/2" WATTS 909 (OR EQUAL) I \ NM —/ / m 06/09/21 BY MkRSTAN, PLLC LAND SURVEYORS OF 2411 US 64 E RPZ TYPE BACKFLOW ♦ i 8" PVC WATER LINE ♦ BUSINESS WEST, PH: (919) 545-7001 PREVENTER IN ABOVE GROUND Q� �♦ � o � HEATED ENCLOSURE 0.25" THICK 16"0 STEEL CASING \ ♦ _ ci 6" PVC WATERLINE PIPE WITH BORE & JACK ♦ R' 2. ALL UTILITIES MUST BE INSTALLED IN ACCORDANCE WITH NCDEQ ? (SEE PROFILE THIS i / / AND HRW STANDARDS AND SPECIFICATION. o �� ���aaa�w�°uuunn PROPOSED NEW POWER EXISTING UTILITY POLE POLE LOCATION, ♦ _ 3. CONTRACTOR SHALL HAVE NORTH CAROLINA ONE CALL m ��•````� 'CN ROB '*,,,, (2) 2" SCH 40 PVC TO BE REMOVED COORDINATE WITH LOCAL r' z CONDUITS FOR FUTURE POWER SUPPLIER / I I BEGINNING 0-632-4949)CONSTRUCTION. cf) LOCATE ALL EXISTING UTILITIES PRIOR TO Q�pFESS/p�l� USE NEW 750 GAL CAPACITY BELOW GROUND OIL NEW FIRE ' o = SEAL =_ HYDRANT, VALVE 4. CONTRACTOR SHALL VERIFY THE LOCATION AND DEPTH OF ALL = 24438 (2) 3" SCH 40 PVC WATER SEPARATOR, SEE i fl EXISTING UTILITIES AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES m ' CONDUITS FOR PHONE PLUMBING PLANS (BY ,AND ASSOCIATED APPURTENANCES coGI OR CONFLICTS PRIOR TO BEGINNING CONSTRUCTION. 0 F _ i - '% NE P AND DATA OTHERS) FOR DETAILS � lq ,,,,...• '���``� / NEW 2" TEE 5. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE ELECTRIC, o 1" SCH 40 PVC CONDUIT / i y� r,NE�� GAS, AND TELEPHONE SERVICE WITH THE APPROPRIATE UTILITY N P"""'Pa""`�� FOR FUTURE PHONE AND r" 1 NEW 8" WATTS 909 RPDA COMPANY PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL DATA / FMB M-FM � F(OR EQUAL) IN ABOVE PROVIDE CONDUITS AS REQUIRED FOR THESE UTILITIES UNDER PAVED / -FM \ pNE�OH GROUND HEATED ENCLOSURE AREAS. (2) 2" SCH 40 PVC �_ FM \ \ �ONE� EXISTING WATER METER, TO a CONDUITS FOR FUTURE i IPF .750PEN 0.2BG o pNE 6. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE CONDUITS O I = BE ABANDONED AND USE \ ONE REMOVED NECESSARY FOR THE IRRIGATION SYSTEM, SITE LIGHTING, AND SIGNAGE 8" PVC WATERLINE PRIOR TO BEGINNING CONSTRUCTION. 0 7. THIS PLAN IS DIAGRAMMATIC AND REPRESENTS THE APPROXIMATE LOCATION OF UTILITIES UNLESS SPECIFICALLY DIMENSIONED. THE o 8"X6"X6" TEE WITH CONTRACTOR SHALL COORDINATE THE ACTUAL AND PROPOSED o " / M O CONCRETE BLOCKING LOCATION OF UTILITIES TO AVOID CONFLICTS. S\DEPPTH ' E I o o ' N E ONE 1 c^ \ 6" PVC WATERLINE 8. REFER TO SHEET. NO. C7.0 THRU C7.2 FOR SITE CONSTRUCTION o pVC W / /FM E ONE RD 1 = ti0 2" PVC FORCEMAIN DETAILS. U .7 EX 8 0 s _0 i FM' E i TR 9. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE WATER — / M / 50 �3 ° ONE 10 1 4" WATER LINE TO BLDG. `o / E ° 1° E \ AND SEWER SERVICE TO THE BUILDING WITH THE BUILDING z " /0 do GRINDER PUMP STATION PLUMBING CONTRACTOR AND THE BUILDING PLANS. NOTIFY ENGINEER �M FM �, ° °\ OHEt/ / FM H ° °pal li o WITH 24 HR CAPACITY, MIN. OF ANY DISCREPANCIES. fM' 10' S\DEPON —! c^ (DESIGN BY OTHERS) CLEAN-OUT, TYP. 10. ALL NEW UTILITY LINES (POWER, CABLE, ETC.) MUST BE ONE °;_ ° e °s � \ I o ti 4' PVC SANITARY SEWER LINE UNDERGROUND. o L / \ \ AT 2% MIN. CLEAN-OUTS r — _FM /ONE RD 11. ALL FITTINGS FOR PVC WATER MAIN AND FIRE HYDRANT PIPING o R FpRCEMAIN=FM ° ° ONE T (P —_ 4, \ EVERY 50' MAX 2 co NE i �STREE PE — \ s / ° \ / / EX 6" pVC MIE_FM HE�oHE 10 12' ND \\ —�\ °3 a1 FOG 1 i TO BE DI PUSH JOINT IPS PVC, CLASS 250 E \ \ 00 IBF .75 BENT BASE OHE / • �1_- \° a I I ' \ o °� 124 9 a _ONE ON_ • • ! ° ° ° ° a °. 1 1 \ I o \ y C o� 0 S@ P1H iOHEi "A ° s� COORDINATOR: HE�o� Blair Pittman T ONEi ONE�PRD ° STORM MANHOLE I I y DRAW BY: OHE/� 10 STREE / C a I \ 1" CONDUIT Narayan Nyaupane HE_ ° PROPOSED STATION X I WALL MOUNTED CONTROL C)i ± 12 I I \ PANEL FOR GRINDER PUMP CHK BY: BPP E °HEM K Q� ,200 SF N SE I \ I I Tgp,C i O 35i0N ' FFE 291 .00 = I �` 4" CONDUIT TO RELOCATED V I > POWER POLE O I I I NSF BENHAVEN EMERGENCY s • SERVICES, INC s I I PROPOSED PROPANE TANK (BY OTHERS) PIN# 9597-37-4281 ° \ PID# 039597 0014 01 •� ° I N \ CONCRETE PAD FOR GENERATOR w DB 3832 PG 965 \ DB841 PG 632 13 °° I N o PC C SLIDE 191-D • _ _° 0I U PB 2020 PG 248 ° I 1 \ °a ° s I CONCRETE PAD FOR � 1 ELECTRICAL TRANSFORMER $" ND \E ° I ROLL OUT TRASH CANS 1 s \ ° s °;; \ 1 ° ° 1 a °\ a o 29 Ld w 295 w LLI O a NEW ENCLOSURE FOR a °\ — o0 w x 0 NEW 8" WATTS 909 J 0 \ ° 11 e 1 Q o 1 w o Z RPDA (OR EQUAL) LL 1 1 ° — 1 0sLli I I Z EX. 1 \� ° ° ° On U\ W I 1 GROUND 0 z w \ / \ ° ° — NC 27 W 29 — / w 290 LL Q� 1 R/W, co V OLL 10I I I � IR \ \ / / 0.25" THICK 16"0 STEEL CASING ^' PIPE WITH BORE & JACK ° V \ (2) 2" SCH 40 PVC CONDUITS O EX. 6 1 \ FOR FUTURE USE (TYP. / / 1 II 1 NEW 8" GATE VALVE ' ^ �o V ! " PVC FORCE M NEW 8"X8"X8" TEE AND 24" MI (ACTUAL POSITION 8" VALVE DEPTH FIELD N C EARAN E VERIFY BEFORE INSTALLATION) v C , 8" SDR21 PVC 285 EXISTING 8" WATER MAIN WATER LINE 285 3: z (POSITION ASSUMED) NEW 2" DOMESTIC n SUPPLY LINE may° I -o c:)\ 1 0 ALL FITTINGS FOR PVC WATER 0 0 0 50 Q MAIN AND FIRE HYDRANT PIPING o N TO BE DI PUSH JOINT IPS/PVC, rn rn � / CLASS 250 w w z 0/ / 1 � ly0 / 03 0+00 1+00 r Q STORMWATER CONTROL STRUCTURE i / \�ti WATER SERVICE PROFILE LO O 1 \ \ AND ACCESS EASEMENT FR / ' / I I 1 I „ , 0 2.5 5 10 SETBP� � \ 25, VERTICAL SCALE: 1 :5 M M M 0 10 20 40 W W \ w000S 5,, 04 0 I I HZ SCALE: 1 :20 pER\MEj%FFE' IBF BASE BENT 5.49 j /' � m 200AK I I — 24 X 36 yo I 20 1 1 � 26GUM REVISIONS 14 NOV 2022 ' � o ,w No. DATE DESCRIPTION REV. BY 22-0011 1 1 s7,,o3 HARNETT COUNTY 1�5.B4 CALL BEFORE YOU DIG! APPROVED FOR 10 12.29.2022 COMMENTS BC 1 UTILITY 1 \ i NORTH CAROLINA LAW REQUIRES NOTIFICATION OF ADD WATER LINE PROFILE NN THE UNDERGROUND FACILITY OWNER NOT LESS Q 03.08.2023 PLAN N/F THAN TWO(2)BUT NO MORE THAN TEN (10) PERMITTING CLEARANCE UPDATE MICHAEL A CHADWICK WORKING DAYS PRIOR TO EXCAVATION OR Q 5.5.2023 NN OF NAIL AT BASE PIN# 9597-36-7576 DEMOLITION \ 1 IBF .75 NAIL 0.5BG w PID# 039597 0014 07 RTH CARO IN 4 8.31.2023 & UNDERDRAIN UPDATE NN 1 S,V_02'01 DB 842 PG 288 NOT FOR CONSTRUCTION SCM EASEMENT 5.62 DB841 PG 632 811 www.n c811 .o rg 1 1 PC C SLIDE 191-B 1 -800-632-4949 0 10 20 40 60 4 ■ 1 North Carolina One-Call Center Inc.