Loading...
HomeMy WebLinkAboutSW3230501_Supplement-EZ Form_20230823 SAND FILTER 1 Drainage area number 1 2 Minimum required treatment volume(cu ft) 1872 'GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered side slopes? No 7 Are the inlets,outlets,and receiving stream protected from erosion(10-year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with General MDC(10)? N/A 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes SAND FILTER MDC FROM 02H.1056 18 SHWT elevation(fmsl) 674 19 Type of sand filter(open or closed) Open 20 If closed,will the filter will be pre-cast or pour-in-place? n/a 21 If closed,top of grate elevation(fmsl) n/a 22 Is this sand filter designed to attenuate peak flows? Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) 3161 cf 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber(fmsl) 678.00 26 Area of the sediment chamber(square feet) 1108 sf 27 Physical depth of the sediment chamber(inches) 24 in 28 Ponding depth in the sediment chamber,above any permanent pool(inches) 24 in 29 Elevation of top of weir between chambers(fmsl) 680 (Sand Chamber 30 Volume that can be retained in the sand chamber(cubic feet) 2281 cf 31 Bottom of the sand chamber(fmsl) 678.00 32 Area of the sand chamber(square feet) 1459 sf 33 Physical depth of the sand chamber(inches) 24 in 34 Ponding depth in the sand chamber,above the sand surface(inches) 24 in 35 Elevation of the bypass device(fmsl) 681 36 Type of bypass device Riser Weir 37 Mechanism for distributing flow over the sand surface Riprap Weir 38 Sand specification for sand chamber ATSM C33 or equivalent 39 Depth above underdrain pipe(inches) 24 in 40 Will the media be maintained to drain at least two inches per hour at the sand surface? Yes 41 Is at least one clean-out pipe provided at the low point of each underdrain line? Yes 42 Will clean-out pipes be capped? Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the sand filter(s):