HomeMy WebLinkAboutWM0401471_Application_20230810 NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY-DIVISION OF WATER RESOURCES
APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM
PLEASE TYPE OR PRINT CLEARLY
In accordance with the provisions of Article 7,Chapter 87,General Statutes of North Carolina and regulations pursuant thereto,
application is hereby made for a permit to construct monitoring or recovery wells.
1. Date: July 27,2023 FOR OFFICE USE ONLY
2. County: Gullford PERMIT NO. ISSUED DATE
3. What type of well are you applying for?(monitoring or recovery): Monitoring
4. Applicant: IANXESS Corporation Telephone: 412-809-3590
Applicant's Mailing Address: 111 RIDC Park West Drive, Pittsburgh, PA 15275-112
Applicant's Email Address(if available): john.scrabis@lanxess.com
5. Contact Person(If different than Applicant): Anthony Kellogg-WSP_ Telephone: 716-474-6247
Contact Person's Mailing Address 4021 Stirrup Creek Drive,Suite 100,Durham,NC 27703 _
Contact Person's Email Address(if available). Anthonv.Kellogg(&wsp.com
6. Property Owner(if different than Applicant): Hags—far Greensboro.LLC Telephone:
Property Owners Mailing Address: 520 Broome Road,Greensboro,NC 27406
Property Owner's Email Address(if available):
7. Property Physical Address(Including PIN Number) 520 Broome Road:PIN- 7873030812
City Greensboro County Guilford Zip Code 27406
8. Reason for Well(s): Groundwater contamination/assessment
(ex: non-discharge permit requirements,suspected contamination,assessment,groundwater contamination,r+emediation,etc.)
9. Type of facility or site for which the well(s)is(are)needed: Manufacturing
(ex: non-discharge facility,waste disposal site,landfill,UST,eta)
10. Are there any current water quality permits or incidents associated with this facility or site? If so,list permit and/or incident no(s).
Site is registered in the I SB Registered Environmental Consultant(RECI Pr ram.
11. Type of contaminants being monitored or recovered: Volatile and Semi-volatile organic compounds
(ex: organics,nutrients,heavy metals,etc.)
12, Are there any existing wells associated with the proposed well(s)? If yes,how many? Yes.14 _
Existing Monitoring or Recovery Well Construction Permit No(s).: NIA
13. Distance from proposed well(s)to nearest known waste or pollution source(in feet): —10 —
14. Are there any water supply wells located less than 500 feet from the proposed well(s)? No
If yes,give distance(s): WA
15. Well Contractor: Parrett-Wolff.Inc. Certification No.: 3371
Well Contractor Address: 501 Millstone Drive Hillsboro 27278
PROPOSED WELL CONSTRUCTION INFORMATION
1. As required by 15A NCAC 02C.0105(f)(7),attach a well construction diagram of each well showing the following:
a. Borehole and well diameter e. Type of casing material and thickness
b. Estimated well depth f. Grout horizons
C. Screen intervals g. Well head completion details
d. Sand/gravel pack intervals
Continued on Reverse ��
PROPOSED WELL CONSTRUCTION INFORMATION (Continued)
2_ Number of wells to be constructed in unconsolidated 5. How will the well(s)be secured? Fiush-rnount pad
material; 6 with locking well cap or locking stick-up
3. Number of wells to be constructed in bedrock: 1
6. Estimated beginning construction date: 7/17/2-023
4. Total Number of wells to be constructed: 7
(add answers from 2 and 3) 7. Estimated construction completion date: 10
ADDITIONAL INFORMATION
1. As required by 15A NCAC 02C.0105(f)(5),attach a scaled map of the site showing the locations of the following:
a. All property boundaries,at least one of which is referenced to a minimum of two landmarks such as identified roads,
intersections,streams,or lakes within 500 feet of the proposed well or well system-
b. All existing wells,identified by type of use, within 500 feet of the proposed well or well system.
C. The proposed well or well system.
d. Any test borings within 500 feet of proposed well or well system.
e. All sources of known or potential groundwater contamination(such as septic tank systems,pesticide,chemical or fuel
storage areas,animal feedlots as defined in G.S. 143-215.1013(5), landfills,or other waste disposal areas)within 500 feet
of the proposed well or well system.
SIGNATURES
The App!' t ass es total r ibility for ensuring that the well(s)will be located,constructed,maintained,and abandoned in
accordance with 15A NCAC 02C.
S' at re of plica t or•Agent Title of Applicant or'Agenh
1 'if signing as Agent, attach authorization agreement stating
rt e IM9 �?e✓)S �l 9 g g g
Printed name of Applicant or*Agent that you have the authority to act as the Agent.
If the property is owned by someone other than the Applicant,the properly owner hereby consents to allow the Applicant to construct
wel(s)as outlined in this Well Construction Permit application and acknowledges that it shall be the responsibility of the Applicant to
e ur ghat vrell(s)w'll bo located,constructed,maintained, and abandoned in accordance with 15A NCAC 02C.
z4 �2--5 - - f �aa
Signs re of Property Owner(if d' Brent than Applicant) Printed name of Property Owner(if different than Applicant) �i
DIRECTIONS
Please send the completed application to the appropriate Dhrision of Water Resources' Regional Office:
Asheville Regional Office Raleigh Regional Office Wilmington Regional Office
2090 U.S.Highway 70 3800 Barrett Drive 127 Cardinal Drive Extension
Swannanoe,NC 28778 Raleigh, NC 27609 Wilmington, NC 28405
Phone: (828)296-4500 Phone: (919)791-4200 Phone: (910)796-7215
Fax: (828)299-7043 Fax; (919)571-4718 Fax: (910)350-2004
Fayetteville Regional Office Washington Regional Office Winston-Salem Regional Office
225 Green Street,Suite 714 943 Washington Square Mall 450 W.Hanes Mill Road
Fayetteville,NC 28301-5094 Washington,NC 27889 Suite 300
Phone: (910)433-3300 Phone: (252)946-6481 Winston-Salem, NC 27105
Fax; (910)486-0707 Fax: (252)975-3716 Phone: (335)776-9800
Fax: (336)776-9797
Mooresville Regional Office
610 East Center Avenue
Mooresville,NC 28115
Phone: (704)663-1699
Fax: (704)663-6040
neftn
GW-22M1R(Rev.5-26-2022)
GZ.✓
1 f . BRODMERD
1pfrlt 0
t MW-1 f MIS r✓ � �•
ow
2� M W 2 R M W-3FL
F
`s r J5 0� / '�• r9 � M W-g
MW-1.1
r
ft
MW-4 MW-4D MW-5 � IeeF;e
4 W_15
IC
-7 MW-12 �� f"r ✓.
LL
1��] • i '
4b k, � �.
I ♦'
Cn
tt\`(dop
o _
MW-14 r or _
MW-16
N { � G•
l0
J
J
O
N
C
N
U � �
N
N o Legend Proposed Type II Monitoring Well MW-17 Mw'19 \oG�eeh
Proposed Type III Monitoring Well s0�t1�
.51
MW-18
• Type II Monitoring Well
E
L
Surface Water Feature
a 0 120 240
w y Site Boundary J Feet
" - ur• ri, Maxar, � E ,Earth tar � graphi• NE=/Airbu DS,U=DA, - � -,Aer �RID,I�N, nd the �1- er mmunit
CLIENT: TITLE:
WSP USA Environment & Infrastructure Inc.
LANXESS CORPORATION PROPOSED WELL LOCATION MAP FIGURE
4021 Stirrup Creek Drive, Suite 100
Durham, NC 27703 DATE: 7/6/2023 SCALE: 1 "=120' PROJ.: 6228230052 SITE: FORMER LANXESS GREENSBORO PLANT 1
(919) 381-9900 DR: A.Kellogg CHK: J.Smith 520 Broome Road
Greensboro, Gilford County, North Carolina
Estimated New Well Construction Details and Depths
520 Broome Rd.
Greensboro,North Carolina
DescriptionSurface isolation
Well ID Well Use Well Well/Casing Slot Size Total Depth Casing Screened Interval Sand Pack Well Head Completion Well Pad Aquifer Zone
Type
ON-SITE WELLS
MW-4D Monitoring III 2"PVC-Sch 40 0.01 65 6 50 55 65 Std Pack Flush mount,well tag,lock 2 x 2 Upper Bedrock
MW-11 Monitoring II 2"PVC-Sch 40 0.01 20 - - 25 35 Std Pack Flush mount,well tag,lock 2 x 2 Saprolite
MW-15 Monitoring II 2"PVC-Sch 40 0.01 20 - 10 - 20 Std Pack Flush mount,well tag,lock 2 x 2 Saprolite
MW-16 Monitoring II 2"PVC-Sch 40 0.01 20 - 10 - 20 Std Pack Stickup,lock,well tag 2 x 2 Saprolite
MW-17 Monitoring II 2"PVC-Sch 40 0.01 20 - 10 - 20 Std Pack Stickup,lock,well tag 2 x 2 Saprolite
MW-18 Monitoring II 2"PVC-Sch 40 0.01 20 - 10 - 20 Std Pack Stickup,lock,well tag 2 x 2 Saprolite
MW-19 Monitoring II 2"PVC-Sch 40 0.01 20 10 20 Std Pack Stickup,lock,well tag 2 x 2 Saprolite
Notes:
in-inches,ft bgs-feet below ground surface
Std Pack-Standard packed screen with sand poured/tremmied in annulus to approximately 2 feet above screen with 2 feet bentonite.
1of1
TYPE III MONITORING WELL RECORD " )
Well Development
Client LANXESS Corporation,LLC
Method Project Number:6229230052 WELL ID: MW-41)
Surge Site Location:520 Broome Rd.,Greensboro State: NC
Well Location:TBD Date Began:TBD
Amount Removed
Drill Method:Hollow Stem Anger and Air Rotary Rig e:Truck Rig Log By:TBD
TBD Aquifer Type:Bedrock Date Installed:TBD
(see Record) Coords: N TBD E TBD Proposed Drill Conftaaor:Parratt Wolff
General Notes/Comments:
Depth from L.S.(feet) Elevation(ft)
Datum(ft)(ft MSL or other)
Top of Steel Guard Pipe ft als/bls N/A
MP for Surveying and Water
Levels
Top of Riser Pipe ft als.Nls
Land Surface L.S. 0.0
Top of Riser Pipe(ft.Ids)
Cement,Bentonite,or
Bentonite Slurry Grout
Riser Pipe:
Grout Data Length(ft) 55
TBD %Water Inside Diameter(ID)(ft) 0.166
TBD %Grout Type of Material PVC
TBD %Bentonite
TBD Volume(gals)
Bottom of6"PVC Outer Casing 50
Method Added
Trernie
TBD Bent.Chips Vol. Top of Bentonite(ft bls) 51
3/8" Size of Chips Bentonite Seal Thickness(ft) 2
TBD Amt.Water Addedd Top of Sand(ft bls) 53
Top of Screen(ft bls) 55.0
Stabilized Water Level(ft bmol TBD
Screen.
Length(ft) 10
Inside Diameter(ID)(ft) 0.166
Slot Size(in) 0.01
TypeofMaterial PVC
Type/Size of Sand q2 Amt Sand(cu.ft.) TBD
Sand Pack Thickness(ft) 12 Method Added: Top pour
Bottom of Screen(ft bls) 65
Bottom of Tail Pipe:(ft bls) 65A
Bottom of Borehole(ft bls) 65A
Borehole Diameter (ft) By Date:
Describe Measuring Point(MP):
Notes:Measure depths from land surface(Is).El—From MP Elm Approval Date
Signature
TYPE II MONITORING WELL RECORD " )
Well Development
Client LANXESS Corporation,LLC
Method WELL ID: MW-11
Project Number:6228230052
Surge Site Location:520 Broome Rd.,Greensboro State: NC
Well Location:TBD Date Began:TBD
Amount Removed
Drill Method:Hollow Stem Auger Rig e:Truck Rig Log By:TBD
TBD Aquifer Type:Saprolite IDate Installed:TBD
(see Record) Com& N TBD E TBD Proposed Drill Contra or:Parratt Wolff
General Notes/Comments:
Depth from L.S.(feet) Elevation(ft)
Datum(ft)(ft MSL or other)
Top of Steel Guard Pipe ft als/bls N/A
MP for Surveying and Water
Levels Top of Riser Pipe ft als./bls
Land Surface L.S. 0.0
Cement,Bentonite,or
Bentonite Slurry Grout
Riser Pipe:
Grout Data Length(it) 21
TBD %Water Inside Diameter(ID)(ft) 0.16
TBD %Grout Type of Material PVC
TBD %Bentonite
TBD Volume(gals)
Method Added
Tremic
TBD Bent.Chips Vol. Top of Bentonite(ft bls) 21
3/8" Size of Chips Bentonite Seal Thickness(ft) 2
TBD Amt.Water Addedd Top of Sand(ft bla) 23
Top of Screen(ft bls) 25
Stabilized Water Level(ft bmol TBD
Screen.
Length(ft) 10
Inside Diameter(ID)(ft) 0.16
Slot Size(in) 0.01
Type of Material PVC
Type/Size of Sand q2 Amt Sand(cu.ft.) TBD
Sand Pack Thickness(it) 12 Method Added: Top pour
Bottom of Screen(ft bls) 35
Bottom of Tail Pipe:(ft bls) 35A
Bottom of Borehole(it bls) 35A
Borehole Diameter (ft) By Date:
Describe Measuring Point(MP):
Notes:Measure depths from land surface(Is).Elev.From MP Elm Approval Date
Signatu e
TYPE II MONITORING WELL RECORD " )
Well Development
Client LANXESS Corporation,LLC
Method Project Number:6229230052 WELL ID: MW-15 through MW-19
Surge Site Location:520 Broome Rd.,Greensboro State: NC
Well Location:TBD Date Began:TBD
Amount Removed
Drill Method:Hollow Stem Anger Rig Type:Truck/Track Rig Lug By:TBD
TBD Aquifer Type:Saprolite Date Installed:TBD
(see Record) Coords: N TBD E TBD Proposed Drill Contractor:Parratt Wolff
General Notes/Comments:
Depth from L.S.(feet) Elevation(ft)
Datum(ft)If,MSL or other)
Top of Steel Guard Pipe ft als/bls N/A
MP for Surveying and Water
Levels Top of Riser Pipe ft als./bls
Land Sorface L.S. 0.0
Cement,Bentonite,or
Bentonite Slurry Grout
Riser Pipe:
Grout Data Length(it) 10
TBD %Water Inside Diameter(ID)(ft) 0.16
TBD %Grout Type of Material PVC
TBD %Bentonite
TBD Volume(gals)
Method Added
Tremic
TBD Bent.Chips Vol. Top of Bentonite(ft bls) 6
3/8" Size of Chips Bentonite Seal Thickness(ft) 2
TBD Amt.Water Addedd Top of Sand(ft bla) 8
Top of Screen(ft bls) 10
Stabilized Water Level(ft bmol TBD
Screen.
Length(ft) 10
Inside Diameter(ID)(ft) 0.16
Slot Size(in) 0.01
Type of Material PVC
Type/Size of Sand q2 Amt Sand(cu.ft.) TBD
Sand Pack Thickness(it) 12 Method Added: Top pour
Bottom of Screen(ft bls) 20
Bottom of Tail Pipe:(ft bls) 2044
Bottom of Borehole(it bls) 2044
Borehole Diameter (ft) By Date:
Describe Measuring Point(MP):
Notes:Measure depths from land surface(Is).Elev.From MP Elm Approval Date
Signatu e