Loading...
HomeMy WebLinkAboutColumbus_Well Abandonment_20230706 (6) WELL ABANDONMENT RECORD For Internal Use ONLY: i 1.Well Contractor Information: WELL ABANDONMENT DETAILIS Justin Radford 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of 3270-A wells abandoned: NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): 1.14 (gal) Geological Resources, Inc. FOR WATER SUPPLY WELLS ONLY: Company Name 7c.Type of disinfectant used: 2.Well Construction Permit#: N/A List all applicable well construction permits fl.e.UIC,County,State,Variance,etc.)ifknown 7d.Amount of disinfectant used: 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): []Agricultural ❑Municipal/Public ❑Neat Cement Grout "Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑Dry Clay ❑Industrial/Commercial ❑Residential Water Supply(shared) "Concrete Grout ❑Drill Cuttings ❑Irri ation ❑ Specialty Grout ❑ Gravel Non-Water Supply Well: ❑Bentonite Slurry ❑ Other(explain under 7g) "Monitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑Groundwater Remediation 15 Ibs of Bentonite ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑Stormwater Drainage 10 I b concrete ❑Experimental Technology ❑Subsidence Control 7g,Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer Pour ❑Geothermal(Heating/Cooling Retum) []Other(explain under 7g) 4.Date well(s)abandoned. 04/24/2023 • ' ;L_°. � _y> 5a.Well location: j i.j L 0 c, Sam's Pit Stop #64 00-0-000035658 Facility/Owner Name Facility M#(ifapplicable) 8.Certifieation:1 4236 Sam Potts Highway, Hallsboro, NC f z� �3 Physical Address,City,and Zip Signature of'CerAed Well Contractor r Well OVnr Date Columbus 088934 By signing this form,I hereby certify that the well(s) was(were)abandoned in County Parcel Identification No.(PIN) accordance with 1 SA NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (ifwell field,one lat/long is sufficient) 9.Site diagram or additional well details: 34.3219583 N 78.5986083 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction record(s)ifavailable.For multiple injection ornon-watersupply wells ONLY with the same constructionlabandonment,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well ID 6a.Well #: 'V I W-9 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 1 1.96 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Iniection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: 2 (in.) above,also submit one copy of this'ffonn within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface•4.94 (ft) Division of Water Resources,Underground Injection Control Program, 1636 Mail Service Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): n/a (ft,) 10c.For Water Suuoly&Iniection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6f.Inner casing/tubing length(if known): 2 (ft.) abandoned. 6g.Screen length(if known): 10 (ft.) i � i Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016