Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yrlmolday Inspection Type Inspector Fac Type
1 �—IN I 2 u 3 I NCG551635 I11 12 23/05/15 17 18 I r I 19 (� I 201 I
211 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I I I^ I I I I I r6
Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA Reserved
I 72 I �, } 73 W 74 71 1 1 1 1 I 180
67 7013 I 71 I liL
f t J
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Dale
Permit Effective Date
POTW name and NPDES Demtit Number)
01:OOPM 23/05/15
14/10/06
6113 Dello Street
6113 Dello St
Exit Time/Date
Permit Expiration Date
Durham NC 27712
01:30PM 23/05/15
18/07/31
Name(s) of Onsite Representative(s)1Titles(s)lPhone and Fax Number(s)
Other Facility Data
1l1
Name, Address of Responsible OfficialMUelPhone and Fax Number
Contacted
Jokya Sanders,6113 Dello St Durham NC 277121/312-927-71511
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Sludge Handling Dispo:
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
James Westcott DWR/RRO WQ1919-791-42471
s/�/ 3
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yrlmolday Inspection Type
U (Cont.)
18
NCG551635 i11 1 23I05115 17
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Findings during the inspection were as follows:
1. Treatment system Operation: The wastewater treatment system shall be always
maintained to prevent seepage of sewage to the surface of the ground. The system was
operating as designed at the time of inspection.
2. Pumping the septic tank: You are required to inspect the septic tank at least yearly to
determine if solids must be removed or if other maintenance is necessary. Septic tanks
should be pumped out every five years or when the solids level is found to be more than
1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping
company can check the status periodically and determine when pumping is required.
During the inspection, the permittee provided verification that the septic tank was
pumped out on April 4, 2020. The General NPDES Permit requires the permittee to retain
records associated with sewage disposal activities for a period of at least 5 years.
3. Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine tablets
be maintained in the chlorinator to ensure proper disinfection of the discharged wastewater.
Chlorine tablets provide effective disinfection and prevent/limit harmful bacteria from
discharging to the environment. The product label for these tablets must indicate the tablets are
approved for wastewater use and not for swimming pools. Part 1, Section D (1) of General
NPDES Permit NCG550000 requires the permittee to inspect the tablet chlorinator and
dechlorinator unit weekly to ensure there is an adequate supply of tablets for continuous and
proper operation. Section D (4) requires the permittee to maintain all system components, always
including ...disinfection units... and in good operating order. The correct chlorine and
dechlorination tablets in the chlorinator/dechlorinator chamber(s) at the time of inspection.
Please continue to ensure the correct type of tablets are used and maintained in the chlorinator
and Dechlorinator unit as required by the General NPDES Permit.
4. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within
General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving
his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed
include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform
and Total Residual Chlorine. At the time of inspection, a receipt of the required annual effluent
analysis was not provided. Please collect a representative sample of the effluent, have it
analyzed by a certified commercial laboratory and submit the results to this office no later than
August 1, 2023 and submit the results to this office within 3 weeks after sampling results are
received. If, during this time, you are unable to collect a representative sample of the effluent
discharge due to insufficient flow from the discharge pipe, then update this office with that
information and continue to monitor the discharge and if conditions for sampling become
favorable, then arrange to collect a sample. Failure to monitor the effluent discharge as
required is a violation of NPDES General Permit NCG550000.
5. Discharge outlet location. The permittee is required to conduct a visual review of the outfall
location at least twice each year (one at the time of sampling) to ensure that no visible solids or
other obvious evidence of system malfunctioning is observed. Any visible signs of a
malfunctioning system shall be documented, and steps taken to correct the problem. The
discharge pipe was clear of obstruction the day of the inspection. Please ensure the outlet is
always visiblelmaintained and cleared of vegetation, soil, and leaves.
Please continue to periodically inspect and evaluate the wastewater system components
are properly maintained and operating as designed. Maintain all associated operational
records onsite for a period of three years as required by the subject permit.
If you have questions or comments about this inspection or the requirements to take
corrective action (if applicable), then please contact Jim Westcott at
Page# 2
Permit: NCG551635 Owner • Facility: 6113 Dello Street
Inspection Date: 05l1512023 Inspection Type: Compliance Evaluat on
james.westcott@deq.nc.gov or 919-7914247.