HomeMy WebLinkAboutGW1-2023-02347_Well Construction - GW1_20230331 WELL CONSTRUCTION RECORD(GW-1) For Internal Use Only:
1.Well Contractor Information:
Mike Young 14.WATER ZONES
Well Contractor Name FROM TO DESCRIPTION
ft. ft.
2370-A fL ft.
NC Well Contractor Certification Number 15.OUTER CASING for multi cased wells OR LINER it a licable
Fishburne Drilling Inc. FROM TO DIAMETER THICKNESS MATERIAL
5 ft 0.5 it 2 in sch.40
Company Name 16.INNER CASING OR TUBING(geothermal closed-too
2.Well Construction Permit#: FROM TO DIAMETER THICKNESS MATERIAL
List all applicable well construction permits(i.e.UIC,Couunty,State,Variance,etc.) ft. ft. in.
3.Well Use(check well use): ft. ft. in.
Water Supply Well: 17.SCREEN
FROM TO DIAMETER SLOT SIZE I THICKNESS MATERIAL
❑Agricultural ❑Municipal/Public 15 1 ft. 2 in• .010 Isch.40 PVC
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ft. ft. in.
❑Industrial/Commercial ❑Residential Water Supply(shared) 18.GROUT
❑h'ri ation ❑Wells>100,000 GPD FROM TO MATERLIL EMPLACEMENT METHOD&AMOUNT
Non-Water Supply Well: 4 ft- 2.5 fL bentonite tremie
MMonitoring ❑Recovery 2.5 ft- 1 ft. grout tremie
Injection Well:
ft. fL
❑Aquifer Recharge ❑Groundwater Remediation
19.SAND/GRAVEL PACK if applicable
❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO MATERIAL EMPLACEMENT METHOD
❑Aquifer Test ❑Stormwater Drainage 15 fL 4 fL #2 silica sand tremie
❑Experimental Technology ❑Subsidence Control ft. ft.
❑Geothermal(Closed Loop) ❑Tracer 20.DRILLING LOG(attach additional sheets if necessary)
❑Geothermal(Heating/Cooling Return) ❑Other(explain under#21 Remarks) FROM TO DESCRIPTION color,hardness,soil/rock typc grain size,etc.)
0 ft. .5 rt• Topsoil
4.Date Well(s)Completed: 03-20-2023 Well ID#W-2 .5 ft. 6 ft- Brown sandy clay
5a.Well Location: 6 ft 15 ft Tan sand "-; �•
Adam Heinrich ft. ft.
l) -E.
Facility/Owner Name Facility ID#(ifapplicable) ft. ft. MAGI 3 1 2023
Sandy Point Rd. ft. ft.
Physical Address,City,and Zip ft. ft
Chowan 783300124627 21.REMARKS
County Parcel Identification No.(PIN)
5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees:
(if well field,one lat/long is sufficient) 22.Certificatio
36.015118 N -76.523104 w 3/23/2023
6.Is(are)the well(s): nPermanent or ❑Temporary Signature of Certified Well Contractor Date
By signing this form,I hereby certify that th well was(were)constructed in accordance with
7.Is this a repair to an existing well: ❑Yes or ONo 15A NCAC 02C.0100 or 15A NCAC 02C.0 00 w, ,Construction Standards and that a copy
IJthis is a repair,fill out known well construction information and explain the nature of the of this record has been provided to the well owner.
repair under#21 remarks section or on the back of this form.
23.Site diagram or additional well details:
8.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same You may use the back of this page to provide additional well construction info
construction,only 1 GW-1 is needed. Indicate TOTAL NUMBER of wells (add'See Over'in Remarks Box).You may also attach additional pages if necessary,
drilled: 24.SUBMITTAL INSTRUCTIONS
9.Total well depth below land surface: 15 (fL) Submit this GW-1 within 30 days of well completion per the following:
For multiple wells list all depths ifdifferent(example-3 a200'and 2@100D
24a. For All Wells: Original form to Division of Water Resources (DWR),
10.Static water level below top of casing: (ft) Information Processing Unit,1617 MSC,Raleigh,NC 27699-1617
IJivater level is above casing,use"+"
11.Borehole diameter: 8.25 (in.) 24b.For Injection Wells:Copy to-DWR,Underground Injection Control(IUC)
Program,1636 MSC,Raleigh,NC 27699-1636
12.Well construction method: Hollow Stem auger
24c.For Water Supply and Open-Loop Geothermal Return Wells:Copy to the
(i.e.auger,rotary,cable,direct push,etc.) county environmental health department of the county where installed
FOR WATER SUPPLY WELLS ONLY: 24d.For Water Wells producing over 100,000 GPD:Copy to DWR,CCPCUA
Permit Program,1611 MSC,Raleigh,NC 27699-1611
13a.Yield(gpm) Method of test:
13b.Disinfection type: Amount:
t ,
Form GW-1 North Carolina Department of Environmental Quality-Division of Water Resources Revised 6-6-2018