Loading...
HomeMy WebLinkAboutNC0067024_Wasteload Allocation_19920708i NPDES WASTE LOAD ALLOCATION PERMIT NO.: NCO067024 PERMITTEE NAME: Watauga County Board of Education FACILITY NAME: Valle Crucis Elementary School Facility Status: Existing Permit Status: Renewal Major Minor. Pipe No.: 001 Design Capacity: 0.0065 MGD Domestic (% of Flow): Industrial (% of Flow): Comments: 100 % Refer : Basinwide / Streamline WLA File Completed By Permits & Engineering At Front Of Subbasin RECEIVING STREAM: Dutch Creek Class: B-Trout Sub -Basin: 04-02-01 Reference USGS Quad: C11NE (please attach) County: Watauga Regional Office: Regional Office Previous Exp. Date: 8/31/92 Treatment Plant Class: 1 Classification changes within three miles: No change within three miles. Requested by: Mack Wiggins Date: 5/6/92 Preparede:r. Date: % % FL- Reviewe GCiy�.� Date: `7 � -tot" W 7 Modeler Date Rec. # S LK a 5 z, b Drainage Area (mi ) 10. Avg. Streamflow (cfs):.2o,(� 7Q10 (cfs) on. � Winter 7Q10 (cfs) 3, �, 30Q2 (cfs) C. 2- Toxicity Limits: IWC % Acute/Chronic Instream Monitoring: Parameters 1•erY1 2%h Q Upstream ✓ Location ✓`J� a(�Q OU"`' l Downstream 4_/ LocationL5D , LLIO�T Qt^*V Effluent Characteristics Summer Winter BOD5 (mg/1) NH3-N (mg/1) , D.O. (mg/1) r, r TSS (mg/1) 3L> F. Col. V100 ml) G pH (SU) G `f LZ,,, �7-_ 0, 5 "C— 2-o°C - Comments: i RECEIVED N.C. Depi. of EWI Facility Name: NPDES No.: Type of Waste: Facility Status: Permit Status: Receiving Stream: Stream Classification: Subbasin: County: Regional Office: Requestor: Date of Request: Topo Quad: FACT SHEET FOR WASTELOAD ALLOCATION Valle Cruis Elementary School NCO067024 Domestic - 100% Existing Renewal Dutch Creek B Trout 040201 Watauga Winston-Salem Wiggins 5/8/92 C11NE Request # 6916 Stream Characteristic: USGS # Date: Drainage Area (mi2): Summer 7Q10 (cfs): Winter 7Q10 (cfs): Average Flow (cfs): 30Q2 (cfs): IWC (%): JUN1?IM Winston-Salerr Regional Offic( 10.6 2.6 3.8 20.6 6.2 Wasteload Allocation Summary (approach taken, correspondence with region, EPA, etc.) Facility requesting renewal of existing NPDES permit. Technical Support recommends renewal of existing limits. Special Schedule Requirements and additional comments from Reviewers: Recommended Reviewed by / / Instream Assessment: (��l��e.,SdQ/�!.�PJ1 Date: Regional Supervisor: �'-<- Date: '-- Permits & Engineering: Z— �� U-�-- _ Date: 4Z'J- Z Date:_6/9/92 RETURN TO TECHNICAL SERVICES BY: J U L 14 1992 �:�r�— d130—i3H3t3 03A130-3 P] CONVENTIONAL PARAMETERS Previous Existing Limits: Monthly Average Summer Winter Wasteflow (1VIGD): 6.0065 BOD5 (mg/1): 30 NH3N (mg/1): monitor DO (mg/1): nr TSS (mg/1): 30 Fecal Col. V100 ml): 200 pH (SU): 6-9 Residual Chlorine (µg/1): 28 Temperature (C): monitor Recommended Limits: Monthly Average Summer Winter WQ or EL Wasteflow (MGD): 0.0065 BOD5 (mg/1): 30 WQ NH3N (mg/1): monitor DO (mg/1): nr TSS (mg/1): 30 WQ Fecal Col. (/100 ml): 200 WQ pH (SU): 6-9 WQ Residual Chlorine (µg/l): 28 WQ Temperature-(C): monitor X7a(%r wecAm � Temr /Its -#YZw d. 5°C d ut -H d sckay E i'n- iw C'0.41 AxM cd 9"C, Limits Changes Due To: Change in 7Q10 data Change in stream classification Relocation of discharge Change in wasteflow Other (onsite toxicity study, interaction, etc.) Instream data New regulations/standards/procedures New facility information Parameter(s) Affected X Parameter(s) are water quality limited. For some parameters, the available load capacity of the immediate receiving water will be consumed. This may affect future water quality based effluent limitations for additional dischargers within this portion of the watershed No parameters are water quality limited, but this discharge may affect future allocations. ' � 1 3 MISCELLANEOUS INFORMATION & SPECIAL CONDITIONS Adequacy of Existing Treatment Has the facility demonstrated the ability to meet the proposed new limits with existing treatment facilities? Yes 4- No If no, which parameters cannot be met? Would a "phasing in" of the new limits be appropriate? Yes No If yes, please provide a schedule (and basis for that schedule) with the regional office recommendations: If no, why not? Special Instructions or Conditions Upstream monitoring: 100 ft. upstream of discharge Downstream monitoring: 100 ft, downstream of discharge Parameters: Temperature Wasteload sent to EPA? (Major) _ N (Y or N) (If yes, then attach schematic, toxics spreadsheet, copy of model, or, if not modeled, then old assumptions that were made, and description of how it fits into basinwide plan) Additional Information attached? (Y or N) If yes, explain with attachments.