Loading...
HomeMy WebLinkAboutNCG551795_Permit (Issuance)_20230323DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director S.E. Eskridge, Jr. 424 Yadkin Run Lane P.O. Box 1834 Southern Pines, NC; 28387 Dear Mr. Eskridge: NORTH CAROLINA Environmental Quality 3/23/2023 Subject: Issuance of Certificate of Coverage (COC) / Authorization to Construct (ATC) NPDES General Permit NCG551795 under General Permit NCG550000 Single Family Residence (SFR) 5312 Farrington Road, Chapel Hill Durham County In accordance with your application for discharge under the subject NPDES General Permit, the Division of Water Resources (DWR) herewith forwards a Certificate of Coverage (COC) and Authorization to Construct (ATC) permit for upgraded facilities. This permit is issued pursuant to the requirements of North Carolina General Statue 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency (EPA) dated October 15, 2007 (or as subsequently amended). Your permit package includes: • Certificate of Coverage (COC) /Authorization to Construct (ATC) • A copy of the approved plans and specifications (signed 03/10/2023). • Engineer's Certification form (to be returned to DWR upon project completion). • A copy of Wastewater Discharge General Permit NCG550000 To maintain your COC, you must remit an annual fee of $60, due each year on the date of this letter, to the Division of Water Resources. Please include the COC number NCG551795 on your check. Mail your Annual Fee to: NCDEQ / DWR / NPDES / SFR Permitting Atm. Wren Thedford 1617 Mail Service Center Raleigh, NC 27699-1617 DWR understands that the subject property has been judged "unsuitable" for a ground -absorption sewer system by the Durham County Health Department. Therefore, your authorized consultant, Agri -Waste Technologies, Inc. (AWT, Inc.) intends to upgrade/install a wastewater treatment system designed to discharge to Surface Waters of the State in accordance with plans and specifications signed by the engineer on 03/10/2023. Compliance under General Permit NCG550000 restricts discharge flow, not to DEQ� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 zl�, NOP.T1 CAFOLM � o.P.w�nm��.nantilu�ar� /'� 919.707.9000 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 Page 2 of 5 5312 Farrington Road NPDES General Permit COC NC551795 exceed 1,000 gallons per day. This ATC covers treatment facilities for a three (3)-bedroom single-famil residence estimated to discharge 360 gpd (120 gallons per bedroom). Please note that you must provide regular treatment -system operation, maintenance and inspections in accord with manufacturer's recommendations, this ATC; and the General Permit. All records, water analyses, and logs are to be kept onsite available for DWR inspection [NCG550000, Section A. (2.)]. Operation and Maintenance. The Permittee is responsible to maintain all components of the approved treatment system, designed to meet Surface Water -Quality Standards. Compliance includes following the manufacturer's guidelines, conducting and documenting inspections, establishing sources for OEM spare parts and supplies, taking samples for analyses, making necessary repairs, and documenting said maintenance for the duration of the permit. Please note that the receiving stream is currently classified and governed as WS-IV; NSW (Water Supply IV; Nutrient Sensitive Waters). If DWR determines that your discharge contributes to future degradation or impairment of this waterbody, an individual NPDES permit may be mandatory. Upon DWR's request, the Permittee must provide records and demonstrate regular efforts to maintain the approved treatment system. The Division recommends that the Permittee solicit manufacture -certified training, or a qualified contractor or service to regularly inspect and maintain this treatment system. Authorization to Construct (ATC) Permit. This ATC details the conditions of installation and operation. Before startup, activation requires notice to the Raleigh Regional Office (919-791-4200), attention Scott Vinson, a minimum of three (3) days in advance of discharge. Such notification shall be made during normal office hours from 8:00 a.m. until 5:00 p.m. Monday through Friday, excluding State holidays. The attached Engineer's Certification form, must be returned to DWR by the Engineer, documenting compliance "as built" in accord with this ATC and approved plans and specifications submitted to DWR and signed on March 10, 2023. No changes may be made without prior approval. Therefore, in accord with the application and the attached approved plans and specifications, DWR hereby authorizes the installation of upgrades to the existing treatment system described as: • 1,250 Gallon Septic Tank with Effluent Filter and Access Risers • AdvantTex AX20-RT Treatment Pod with Re -circulating Chamber • UV Disinfection System 0 Control Panel with Alarm • Discharge Outlet with Riprap • All Piping and Appurtenances Compliance with the above shall include a leakage test performed on reused tanks and proposed new tanks, or leak -certified new by the manufacture not to exceed an exfiltration rate of twenty (20) gallons per twenty-four (24) hours per 1,000 gallons of tank capacity. The Engineer's Certification shall serve as proof of compliance with this condition. Mail the completed Engineer's Certification to: DEQ / DWR/ NPDES Program 1617 Mail Service Center Raleigh, NC 27699-1617 ❖ The Permittee shall, for the life of the treatment facility, maintain on site a copy of the approved plans and specifications available for DWR inspection. All elbow piping must conform to the long -sweeping type. All cleanouts must be housed in meter boxes below grade. This treatment system shall be located at least 15 feet away from a dwelling, at least 100 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 Page 3 of 5 5312 Farrington Road NPDES General Permit COC NC551795 feet from any water -supply well either on- or off -site. The system shall also be located and constructed above any applicable 100-year flood line; 50-ft setback from property lines. Upon completing construction and prior to operating this permitted facility, a North Carolina - registered engineer shall sign and submit to DWR the attached Engineer's Certification form, thereby certifying that the permitted facility has been installed in accordance with the NPDES Permit, this COC, this ATC, and the approved plans and specifications. This ATC permit is issued in accordance with Part III, Paragraph 2 of NPDES General Permit NCG550000, and is subject to revocation unless wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in this General Permit. In the event that the facilities fail to perform satisfactorily, including creating nuisance conditions, the Permittee shall take immediate corrective action as may be required by this Division, such as the construction of additional or replacement wastewater treatment(s) or disposal facilities. Failure to abide by the requirements of this ATC permit may subject the Permittee to an enforcement action by the Division of Water Resources in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. If any parts, measurement frequencies or sampling requirements contained in this general permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, the COC shall be final and binding. This COC is not transferable except after notice to the Division of Water Resources. The Division may modify or revoke and reissue this COC. This COC does not affect your legal obligation to obtain other permits that may be required by the Division of Water Resources, the Division of Energy, Mineral and Land Resources, the Coastal Area Management Act, or any other Federal, State or Local government. NPDES Contact. If you have any questions concerning the requirements of this Certificate of Coverage or Authorization to Construct permit, please contact Bradley Bennett at bradlgy.bennettkncdenr. og_v or (919) 707-3629. Sincerely, DocuSigned by: 8328B44CE9EB4A1... Richard E. Rogers, Jr. Director, Division of Water Resources Attachments: COC; Plans, Engineer's Certification form (to be signed and returned to DWR), Copy of GP NCG550000 cc: Raleigh Regional Office — Laserfiche NPDES General Permit Files — Laserfiche Kevin Davidson — AWT, Inc. - electronic DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 Page 4 of 5 5312 Farrington Road NPDES General Permit COC NC551795 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES CERTIFICATE OF COVERAGE - NCG551795 Under GENERAL PERMIT NCG550000 TO DISCHARGE 100%-DOMESTIC AND SIMILAR WASTEWATERS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NEDES) In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, E.S. Eskridge Jr. is hereby authorized to operate a wastewater treatment facility consisting of a septic tank with effluent filter, AdvanTex AX-20 RT Pod system with re -circulating chamber, UV disinfection, control panel with alarm, discharge point with riprap; discharging from facilities located at the Single -Family Residence (SFR) 5312 Farrington Road, Chapel Hill, NC Durham County to receiving waters designated as UT to Little Creek [Stream Index: 16-41-1-15-(0.5)] a waterbody currently classified WS-IV; NSW located within sub -basin 03-06-06 [HUC: 030300020603] of the Cape Fear River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV of General Permit NCG550000 as attached. This Certificate of Coverage and Authorization to Construct shall become effective April 1, 2023 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signedthisday March 23, 2023 DocuSigned by: 18328B44CE9EB4A1 .. Richard E. Rogers, Jr. Director, Division of Water Resources By Authority of the Environmental Management Commission DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 Discharge Eskridge Property E.S. Eskridge, Jr. Facility 5312 Farrington Road, Chapel Hill, NC `4 Location Receiving Stream: UT to Little Creek Stream Class: WS-IV; NSW (not to scale) River Basin: Cape Fear Sub -Basin: 03-06-06 Latitude: 35' 55' 18.3" Longitude: 78' 59' 32.2" Stream Segment 16-41-1-15-(0.5) HUC#: 030300020603 NORTH NPDES Permit NCG551795 uad: Southwest Durham County: Durham DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 &M Engineers and Soil Scientists Agri -Waste Technology, Inc. 501 N. Salem Street, Suite 203 Apex, North Carolina 27502 919-859-0669 www.agriwaste.com Date: FINAL DESIGN NOT RELEASED FOR CONSTRUCTION RECEIVED March 10, 2023 NCDEQ/DWR/NPDES 5312 Farrington Road Chapel Hill, NC 27514 Durham County Plans and Specifications for Discharge System Design Engineer: March 10, 2023 Kevin Davidson, P.E. Agri -Waste Technology, Inc. 501 N. Salem Street, Suite 203 Apex, NC 27502 Office: 919-859-0669 Direct: 919-367-6310 Email: kdavidsonkagriwaste.com 1 of 61 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 Narrative Description of Discharge Treatment System The Discharge System that has been designed considers the following components: - Septic Tank - AdvanTex AX20-RT Treatment Pod - UV Disinfection - Discharge Outlet - Control Panel Due to the advanced technology in this system, a Certified Operator should be contracted to maintain this system. Septic Tank A new 1,250-gallon septic tank will be installed for this system. The existing 1,000-gallon tank will be abandoned in place. An Orenco 8" Biotube effluent filter will be installed in the outlet end of the septic tank. 24" access risers will be installed on both the inlet and outlet ends of the septic tank. All wastewater from the single-family residence, including greywater, will be routed into the septic tank. Waste that exits the septic tank will flow via gravity into the AdvanTex AX20-RT Treatment Pod. AdvanTex AX20-RT Treatment Pod The treatment component of the system is an AdvanTex AX20-RT treatment pod. The pod is an integrated unit that combines recirculation, treatment, and discharge modules into a single, sealed unit. Liquid from the septic tank will flow via gravity to the inlet of the treatment pod and into the recirculation tank portion of the AX-RT unit. Liquid from the recirculation tank will be periodically applied across the filter fabric. Wastewater will be sprayed over the textile sheets. The wastewater percolates down through the textile sheets and is distributed between the recirculation chamber and discharge chamber by means of the tank baffle. The treated wastewater then exits the AX-RT unit via gravity to the discharge outlet after passing through the UV disinfection system within the AX- RT unit. The recirculation pump is controlled by a system of 3 floats that operate the recirculation pump in a Timed Dose arrangement. Float I (lowest elevation) is a redundant off float. Float 2 is a Peak Enable Float and Float 3 acts as a High Water Alarm. Under normal operation, the redundant off float will be engaged thereby activating the timer in the control panel. At the pre-set interval, the pump will engage and distribute effluent over the textile fabric ("on" cycle). Following this period, the pump will turn off and rest for a designated time ("off' cycle)". During periods of high water in the recirculation portion of the tank, the Peak Enable float will engage and reduce the pre-set "off' time and thereby send increased flow across the fabric. If the water level in the recirculation tank continues to rise, the High Water Alarm will activate. 3of61 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 To prevent groundwater from affecting the pod, the pod will be installed on a bed of gravel. Anti - flotation measures or a concrete ring installed around the mid -flange will be installed to provide extra ballast to prevent the flotation of the pod during high water table conditions. UV Disinfection Disinfection for the system will be accomplished using a UV system. The UV light should operate for approximately one year prior to needing to be replaced. If the UV light burns out or loses sufficient intensity (below a set threshold) an alarm will activate and disable the system pump. An alarm light on the control panel will also illuminate. When the alarm is activated, the homeowner should reduce water use (laundry, dishes, washing) until the system is operating properly. Discharge Outlet The system discharges into a culvert located on the property. Riprap will be placed at the discharge location to provide aeration of the water as it is discharged and also as erosion protection. Vegetation and debris should be kept clear of the discharge location. A grate will be installed on the discharge pipe to prevent animals and rodents from entering the discharge pipe. Control Panel One control panel will be installed with this wastewater system. This panel will control operation of the pumps and UV system. If desired, this panel can be connected to a land -based phone line that will notify the operator of system operation. 4of61 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 dkridae Residence surface Discharae Project Location: 5312 Farrington Road Chapel Hill, NC 27514 Durham County PIN# 0709-20-13-8735 Project Owner: E. S.m Eskridge 424 Yadkin Run Lane Southern Pines, NC 28387 (919) 423-6050 stan@4unc.com z— ri 1 t _~Cirlp F{Ilf p� 1 SITE ry j �Ir'',• R� rr r- arrrescpnlG. �! VICINITY MAP Project Consultant: Kevin D. Davidson, P.E. kdavidson@agriwaste.com Agri —Waste Technology, Inc. Sheet Index 501 N. Salem Street, Suite 203 Sheet 1 Cover Sheet Apex, NC 27502 Sheet 2 Property Layout (919) 859-0669 Sheet 3 Component Layout (919) 233-1970 Fax Sheet 4 System Detail #1 Sheet 5 System Detail #2 System Overview: Single Family Residence Three (3) Bedroom, 360 gpd Design Standard — Discharge AdvanTex AX-20 RT Pod with Single Bulb UV Disinfection AVVr Engineers and Soil Scientists Agri -waste Technology, Inc. 501 N. Salem Street, Suite 203 Apex, North Carolina 27502 919-859-0669 www.agriwaste.com Eskridge Surface Discharge Wastewater Treatment System Owner Information: E. S. Eskridge 424 Yadkin Run Lane P.O. Box 1834 Southern Pines, NC 28387 (919) 423-6050 stan04unc.com Property Information: 5312 Farri1on Road Chapel Hill, ryC 27514 Durham County PIN# 0709-20-13-8735 SEAL I FINAL DESIGN NOT RELEASED FOR CONSTRUCTION REV. ISSUED DAIS DESCRIPTION SHEET TITLE Cover Sheet DRAWN BY: CREATED ON: A. HUDSON 03/02/2023 REVISED BY: REVISED ON: RELEASED BY: RELEASED ON: 10 of 61 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 5315,GEORGE KIN \ / ROAD LLC D.B. 9572-77-773 i ANITA H HICKS-h D.B. 5210-266 '�' i NOTES: - Adjust tanks to meet site constraints. - Control Panel to be within 15'-18' of the UV system. Can be mounted near the house. PROPERTY LAYOUT JAMES G KING JUNE PIERCE KING D.B, 384-210 IIN POWERLINE EASEMENT JEROME SOLOMON SHONGYAN WANG LIWEN ZHONG D.B. 7540-156 0 100 200 7771 Feet AM/r Engineers and Soil Scientists Agri -Waste Technology, Inc. 501 N. Salem Street, Suite 203 Apex, North Carolina 27502 919-859-0669 www.agriwaste.com Eskridge Surface Discharge Wosteylater Treatment System Omer Information: E. S. Eskridge 424 Yodkin Run Lone P.O. Box 1834 Southern Pines, NC 28387 (919) 423-6050 slano4unc.com Property Information: 5312 Farrington Rood Chapel Hill, MC 27514 Durham County PIN# 0709-20-13-8735 PROFESSIONAL ENGINEER SEAL FINAL DESIGN NOT RELEASED FOR CONSTRUCTION REY, ISSUED DATE DESCRIPTION SHEET TITLE Property Layout DRA N BY: CREATED ON: HUDSON 03/02/2023 REVISED BY: REVISED ON: RELEASED BY: RELEASED ON: DRAWING NU BER WW-2 11 of 61 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 ST A � O I Uv � AX20-RTO �sora`ge / �o� COMPONENT LAYOUT / / J 0 LL1 DL -To_H_ou_se 0 5 10 Feet T Lys \�� chap \ T 9P 1 Op h 0 5 10 Feet \ n DISCHARGE POINT W W-3 Line Legend Line Name Size Type DL Drain Line 4.0" SCH 40 PVC EDL Effluent Discharge Line 4.0" SCH 40 PVC ERL Effluent Return Line 1.0" SCH 40 PVC NOTES: - Adjust tanks to meet site constraints. - Grade surface in tank area as needed to maintain required slope on pipes. - Effluent discharge line (EDL) to maintain minimum 18" burial depth. - Ball valve on effluent return line may be inside RT Unit or ST inlet riser. - Properly abandon existing septic tank and treatment system. - Adjust outlet location of all gutters/downspouts as needed to shed runoff away from treatment system. COMPONENT LEGEND ST Septic Tank CP Control Panel RT Recirculation Tank LIV LIV Disinfection A AdvanTex Pod P Pump SIB Splice Box EF Effluent Filter IT Inlet Tee BV Ball Valve Avvr Engineers and Soil Scientists Agri -Waste Technology, Inc. 501 N. Salem Street, Suite 203 Apex, North Carolina 27502 919-859-0669 www.agriwaste.com Eskridge Surface Discharge Wastewater Treatment System Owner Information: E. S. Eskridge 424 Yadkin Run Lane P.O. Box 1834 Southern Pines, NC 28387 (919) 423-6050 stun®4unc.com Property Information: 5312 Farrington Road Chapel Hill, NC 27514 Durham County PIN# 0709-20-13-8735 PROFESSIONAL ENGINEER SEAL FINAL DESIGN NOT RELEASED FOR CONSTRUCTION REV. ISSUED DATE DESCRIPTION SHEET TITLE Component Layout DRAWN BY: CREATED ON: A. HUDSON 03/02/2023 REVISED BY: REVISED ON: RELEASED BY: RELEASED ON: I ---- DRAWING NUMBER WW-3 12 of 61 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 s Drenca 24' Rlser Dase Lld L�!J 4 INLET 6 OUTLET BOOTS ON ENDS OLNY • 713P VIEW MEASUREMENTS ARE TO WIDEST DIMENSIONS Cy East In Place arenco Rlser Adapters _F 4' IRS Ve• O TLF 2/4'r— 3e 2/4' a• ADtfPME-CE�� — WATER LEVEL SHOAF PRECAST SEPTIC INC. MODEL: T.S 1250 $TB NON TRAFFIC 1250 Gallon Septic Tank 413l) WEST US HWY 64 LEXINGTON, NC 27295 PHONE (336) 767-5826 FAX (336) 787-2826 WWW.SHOAFPRECAST.COM SHOAF-1,250 SEPTIC TANK STB-389 LIQUID CAPACITY-1,252 GALLONS/10' AIRSPACE TANK HEIGHT-61 }' BOTTOM OF TANK TO CENTER OF INLET-52' BOTTOM OF TANK TO CENTER OF OUTLET-50' LENGTH TO WI➢TH RATIO-2 TO 1 SIZE OF INLET 6 01 PIPE TYPE OF INLET 6 OUTLET-POLYLOCK OR EQUAL (MEETS ASTM C-923) CONCRETE PSI-40001 TANK WEIGHT- 11,000 1 REINFORCEMENT PER STATE CODE SCALE - N.T.S. -*VT -ME NDT S PPLIED VENT 4e' TO BOTTOM DF FLOW u ve• 4. OUTLET THROUGH TO BOTTOM OF 4, INLET 4, SIDE VIEW s 1 Not to scale n SEPTIC TANK (OR EQUIVALENT) Not to scale F1R•�E„T� I o Ire• u ve' � � � � • 04'FLOW THROUGH STD-389 n Clean, Tamped Backfil 4" SCH 40 PVC B Rip Rap-\ w/ Grate I _-s s s s;is s s ss_s s s %i s IlnilnT - Tamped Backfill 'Undisturbed Earth @ DISCHARGE RIPRAP DETAIL plce8a ~roa�nage �� �Ym'Camm"CnrstmlPamel Rau rchmp eaym�r aefnepm7 a.G� C—Igh—pond Flosa-1,0 im (, opn 1:pine m3 e sepX>mtsro AX20 Recirc. Tank - Top View Fm. c naI talledHem _— ---- (2) Gioke'gW1 Pump Canncceoas _dFlood (Optiw s,Plicc box, J, Se 4c _ 23.88" 24,88 sesx, aotenowa> F'.tCompa,'lmerct 1��, eraax lz" t. Recirc. Rehm Y R 44^•� ••,• — - - Yvlve >1^ z131 _—_—_—_ —_—_ _— F .c.aranl. one 2g., ii �nr Orexnu("_ grnco Rectir. PeanP System oe„cao�.ena�e AX20 Recirc. Tank -Side View _14"1P"' Discharge Chamber - End View Not to scale n AX20-RT UV ADVANTEX TREATMENT SYSTEM - FOR ILLUSTRATION ONLY Install Safety Net In Each Access Riser Install Safety Net BeloW 2nd Riser Rib Rubber Washer, Flat Washer, & cap Nut or Lock Safety Nut Net m Threaded Eye Rise Wall Riser Wall S*Clamp fNtti Eye B (4 Above Filter) Not to scale @) SAFETY NET (INSTALL IN TANK RISERS) i�- 24' (typ) Fiberglass Reinforced Beam 24" (typ) Turn Budde W In. Not to scale ANTI -BUOYANCY INSTALLATION NOTES 1. Boundary information based on GIS and aerial data. 2. Septic Tank to have approved Orenco Effluent Filter model FFPS-0854-36 NC- 3. Treatment system to be 100' from any Well, 15' from residence or building foundation, 50' from property lines, and 50' from stream/pond. Verification of these setbacks to be performed by contractor. 4. Contractor shall backfill around all access areas such that storm Water is shed away from potential entry points. 5. Invert elevations of all components to be verified in field by contractor to ensure proper operation. 6. All system piping to be SCH40 PVC except Where noted 7. All gravity elbows to be long radius or long sweeping type elbows. 8. Actual installation and placement of treatment system to be overseen by Contractor. 9. Use Class 'B' erosion control stone for structural base for outlet stabilization structure. Use #5 or #57 stone for sediment control. 10. Discharge line must be covered to a minimum depth of 18". Discharge pipe outlet to have grate. 11. Flow from the receiving stream back into the system shall be prevented. 12. Engineer Inspection required during system installation and at final completion. 13. Contractor to seed and/or mulch disturbed areas to coincide With existing landscape. Area shall not be left With uncovered soil. 14. Upon system completion, Contractor to supply Engineer With documentation of installation and a signed letter indicating system Was installed per approved design or noting any deviation from approved design. 15. Contractor to install internet line to VCOM control panel. 16. AdvanTex-RT Unit to be placed on gravel bed and backfilled With gravel. 17. Mount Control Panel a minimum of 24" above grade. Power to panel to be installed by licensed electrician per code. 18. Leak test required on septic tank and pod. 19. Water spigot to be located on exterior of residence Within 50' of tanks. 20. Pour concrete collar around flange of treatment unit or install anti -buoyancy beams per manufacturer's recommendations. 21. Existing septic tanks to be properly abandoned. Contractor shall provide documentation from Durham County. 22. All Wastewater from the SFR, including greyWater, is to be conveyed to the septic tank. 23. Separate circuits for each pump and alarm/control panel are requried (2-12OV, 20 amp; 1-120V, 15amp)_ Separate conduits required for phone and internet line. 24. Recirculation Timer Settings: TIME ON/OFF: 0.94/14.06 minutes 12 gpm to Pod / 5 gpm to Septic Tank. ANW Engineers and Soil Scientists Agri -Waste Technology, Inc. 501 N. Salem Street, Suite 203 Apex, North Carolina 27502 919-859-0669 www.agriwaste.com Eskridge Surface Discharge Wastewater Treatment System Owner Information: E. S. Eskridge 424 Yadkin Run Lane P.O. Box 1834 Southern Pines, NC 28387 (919) 423-6050 stan®4unc.com Property Information: 5312 Farrington Road Chapel Hill, NC 27514 Durham County PIN# 0709-20-13-8735 PROFESSIONAL ENGINEER SEAL FINAL DESIGN NOT RELEASED FOR CONSTRUCTION REV, ISSUED DATE DESCRIPTION SHEET TITLE System Details #1 DRAWN BY: CREATED ON: A. HUDSON 03/02/2023 REVISED BY: REVISED ON: RELEASED BY: RELEASED ON: DRAWING NUMBER WW-4 13 of 61 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 Control Panel 24" above ground (min.) 4"x6" Support Post 24" Gasketed Fiberglass Safety Net With Safety Net With 4 Bury 36" min in Lid With Stainless Quick Disconnect Quick Disconnects Vent natural soil. Steel Bolts (4) One Piece Advantex AX20-RT 6" above ground Riser UV Unit surface Splice Box Slope soil away Cast In Place from unit Ball Valve Riser Adapter i Return -- ---- _ Line Undisturbed Clean, Tamped Bockfill 1 Return ' Earth Clean, Tamped Une I Backfill U ion With -__- ; --- FIoW Orifice _I III -I � I -I °oo I I -I I I -I I I 'o o o L Baffle I I I I II I II I II I o°c, Discharge Line Holes 1 Undisturbed j Earth to f I Effluent1 I Support Pipe E 1 Filter ��Compacted (l Baffled Septic Tank (FTP 0848-36-NC i Backfill \ Recirculation I-- -------------- #78 Gravel Pump Vault 6" (min) Gravel Bed 6" (min) Gravel Bed -I I I -I III-III-III-III-� i'� #5 or #57 Gravel I I -III -III -III -III III- _ _ Recirculation l-I �-III-III-11=III- III-� I_I I I=1 I -I Transfer Line Undisturbed Earth Undisturbed Earth Return Valve Not to scale SYSTEM DETAIL - FOR ILLUSTRATION ONLY SINGLE CONDUIT (no splices) CONDUIT SUPPORT RISER OR CORRUGATED PIPE COVER CONDUIT MINIMUM 18" TO RT UNIT INSTALL MULTIPLE CONDUITS AS NEEDED Not to scale MOUNT PANEL DIRECTLY TO POSTS OR TO ALUMINUM PLATE CONTROL (grind off protruding screws) PANEL 0000 2' min. 2X4TREATED -SECURE WITH 4 - 3" DECK SCREWS PER POST GRAVEL AV*fr Engineers and Soil Scientists Agri -Waste Technology, Inc. 501 N. Salem Street, Suite 203 Apex, North Carolina 27502 919-859-0669 www.agriwaste.com Eskridge Surface Discharge Wastewater Treatment System OWner Information: E. S. Eskridge 424 Yadkin Run Lane P.O. Box 1834 Southern Pines, NC 28387 (919) 423-6050 stun®4unc.com Property Information: 5312 Farrington Road Chapel Hill, NC 27514 Durham County PIN# 0709-20-13-8735 I , I TO POWER SOURCE PROFESSIONAL ENGINEER SEAL ALL CONDUIT TO BE 3/4 " (min) 3' BURIAL DEPTH MINIMUM CONTROL PANEL SUPPORT (OR EQUIVALENT) Elevation Determination Sheet Site Elevation Readings AdvanTex RT Unit Approximate Elevations Elevation Pipe Length from ST outlet 13.00ft Dranline Invert at House 290.50ft Slope of Line 2.75% GS at Septic Tank 291.00ft Ground Surface at RT Unit 290.50ft GS at RT Unit 290.50ft Elevation at Inlet Invert 288.52ft Float Settings Elev. (ft) Height Elevation at Discharge Invert 288.00ft Distance to Inlet invert from top 25.8in from Tank Top of Unit 290.67ft Recirculation Floor (in) Septic Tank Cover over Inlet Invert 1.98ft Low Water/Redundant Off 287.00 28 Ground Surface at Septic Tank 291.00ft 23.79in Pump Override Timer 288.08 41 Cover over Septic Tank 12.00in Extension Height 0.00in High Water Alarm 288.21 42.5 1.00ft Height of Unit 72.00in Elevation at top of Septic Tank 290.00ft 6.00ft Discharge Pump Distance to Inlet Invert from Top 0.96ft Bottom Elevation 284.67ft Pump Off 286.00 16 Elevation at Inlet Invert of ST 289.04ft Outlet Distance from Bottom 32.5in Pump On 287.58 35 Drainline Length From House 60.00ft Outlet Elevation 287.38ft High Water Alarm 287.75 37 Slope of Line 2.43% Height of Unit Exposed 2.00in Distance to Outlet Invert from Top 1.13ft Elevation at Outlet Invert of ST 288.88ft n ELEVATION DETERMINATIONS �ws FINAL DESIGN NOT RELEASED FOR CONSTRUCTION REV. ISSUED DATE DESCRIPTION SHEET TITLE System Details #2 DRAWN BY: CREATED ON: A. HUDSON 03/02/2023 REVISED BY: REVISED ON: RELEASED BY: RELEASED ON: DRAWING NUMBER WW-5 14 of 61 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 **NOTE -USE 24' CAST -IN -PLACE 25 1/2 SHOAF PRECAST SEPTIC INC. ORENC❑ RISER 19 1/2 ADAPTER 3.0 Orenco 24' 6'0 Oren co 24' Riser Base Riser Base ' W/ Lid W/ Lid 59 /2' \ 65 /2'13 4' OUTLET BOOT TOP VIEW ­KTOP VIEW MEASUREMENTS ARE TO WIDEST DIMENSIONS 4' SIDE INLET BOOT SCALE — N.T.S. Cast in Place Orenco Riser Adapters 3A''t' 4.0' -NOTE 1' BUTYL RUBBER STATE MASTIC SEALANT APPROVAL # 25 1/2 CONTINUOUS IN JOINT SHOAF-1250 s 1/z• STB-389 INLET i191/2 0 TLET 91/2 78 3/4 ' --NOTE-TEE NOT SUPPLIED 10' AI SPACE V VENT 2' VENTSLOT LL 4 .0'TO BOTTOM OF 4' OUTLETOF .0' 61 /2' 54 /2' 5 0'TO BOTTOM 4' INLET ' FL0W THROUGH.--ma.o• FLOW THROUGH SIDE VIEW END VIEW 75 35' 6' 16 22 2.0' Not to scale MODEL: TS 1250 STB NON TRAFFIC 1250 Gallon Septic Tank 4130 WEST US HWY 64 LEXINGTON, NC 27295 PHONE C336) 787-5826 FAX C336) 787-2826 W W W,SHOAFPRECAST,COM SHOAF-1,250 SEPTIC TANK STB-389 LIQUID CAPACITY-1,252 GALLONS/10' AIRSPACE TANK HEIGHT-61 BOTTOM OF TANK TO CENTER ❑F INLET-52° BOTTOM OF TANK TO CENTER OF OUTLET-50' LENGTH T❑ WIDTH RATIO-2 T❑ 1 SIZE ❑F INLET & OUTLET-4' PIPE TYPE ❑F INLET & OUTLET—P0LYL0CK ❑R EQUAL (MEETS ASTM C-923) CONCRETE PSI-4000; TANK WEIGHT— 11,000 LBS, REINFORCEMENT PER STATE CODE 15 of 61 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Permittee- NPDES COClATC Number: Coun Engineer's Certification: NORTH CAROLINA Environmental Quality E.S. Eskridge, Jr— 5312 Farrington Road NCG551795 Durham I, , a duly registered Professional Engineer in the State of North Carolina, as authorized by the Permittee to observe [ daily, part time, full time ] the construction of the project, , Project Name Location do hereby state that to the best of my abilities, I practiced due care and diligence to observe the construction of said project such that it was advanced and completed in accordance and in compliance with the NPDES Permit, approved plans and specifications, Authorization to Construct Permit, and General Permit Certificate of Coverage issued by the Division of Water Resources. Signature Registration No. Date [Stamp] [Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $10,000, or by imprisonment not to exceed six months, or by both. [ 18 U.S.C. Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment not more than 5 years, or both, for a similar offense.] D � ��� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 �w 919.707.9000 DocuSign Envelope ID: 42F7C7FE-6E59-444A-96EC-6A626D410002 NPDES General Permit NCG550000 A Complete Copy of the 2020 NCG550000 General Permit was Provided in the Permittee Package STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES GENERAL PERMIT NCG550000 DISCHARGE OF DOMESTIC WASTEWATER FROM SINGLE FAMILY RESIDENCES AND OTHER 100% DOMESTIC DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, this permit is hereby issued to all owners or operators, hereafter permittees, which are covered by this permit as evidenced by receipt of a Certificate of Coverage by the Environmental Management Commission to allow the discharge of treated domestic wastewater in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II and III hereof. This permit shall become effective November 1, 2020. This permit shall expire at midnight on October 31, 2025. Signed this day 10/30/2020 DocuSigned by: �4 P Nof 8FB19BI349DD2478... for S. Daniel Smith, Director Division of Water Resources By Authority of the Environmental Management Commission Page 1 of 18