Loading...
HomeMy WebLinkAbout20221135 Ver 2_TriWest BC - Building 2_2023.02.21_20230224l` BUILDING 2 CONSTRUCTION DRAWING PACKAGE US HIGHWAY 158 DAVIE COUNTY, NORTH CAROLINA MOCKSVILLE DEVELOPMENT PARTNERS, LLC x isazs5zzso _ — ,� . W r soa9»izo � — R/W R/W z zazsso — — — — i R R/W R/W / R/W R/W /W— DAVIE COUNTY TRC NOTES 1. CONSTRUCTION SITE SHALL BE KEPT CLEAN WITH DUMPSTERS COVERED TO PREVENT DEBRIS FROM LEAVING THE SITE. 2. ANY HVAC, DUMPSTER OR OTHER STORAGE OF THE LIKE SHALL BE SCREENED. 3. OUTDOOR STORAGE OF ANY KIND SHALL BE SCREENED FROM PUBLIC VIEW. OUTDOOR STORAGE INCLUDES MATERIALS, EQUIPMENT, PARTS, SUPPLIES OF ANY TYPE, OR ANY OTHER ITEM LOCATED ON THE PROPERTY. 4. THE CONSTRUCTION ENTRANCE NEEDS TO BE KEPT CLEAN OF MUD/ROCK AND DEBRIS. CONTRACTOR SHOULD HAVE PLAN READY TO IMPLEMENT. 5. EXISTING TREES THAT ARE TO BE USED IN LIEU OF LANDSCAPING REQUIREMENTS OR EXISTING TREES THAT ARE NOT TO BE REMOVED SHALL BE PROTECTED. A PROTECTIVE BARRIER SHALL BE PLACED AROUND THE ROOT PROTECTION AREA (DRIP LINE) PRIOR TO GRADING OF THE PROPERTY. 6. SITE LIGHTING REQUIREMENTS: 6.1. MAXIMUM POLE HEIGHT IS 30 FEET 6.2. ALL LIGHTS MUST BE CUT OFF FIXTURES 6.3. LIGHT SHALL BE CONFINED TO STAY WITHIN PROPERTY 6.4. NO OUTDOOR LIGHTING SHALL BE INSTALLED OTHER THAN NORMAL RESIDENTIAL DUSK TO DAWN LIGHTING. NO LIGHTING SHALL BE DIRECTED ONTO ADJACENT PROPERTY. FLOOD LIGHTS OR OTHER HIGH -INTENSITY LIGHTING SHALL BE PROHIBITED ANY NEW SIGN OR CHANGE IN EXISTING SIGN WOULD REQUIRE THE ISSUANCE OF A PERMIT, DETAILED DESIGNS SHOWING ALL RELEVANT INFORMATION REQUIRED TO DETERMINE COMPLIANCE WITH THE SIGN REGULATIONS SHALL BE REQUIRED AS PART OF THE COMPLETE APPLICATION. SIGNAGE WILL NEED TO COMPLY WITH SECTIONS 155.090 AND 155.148 OF THE DAVIE COUNTY UDO, INCLUDING NO OFF PREMISE SIGNAGE. FIRE HYDRANTS AND FDC SHALL HAVE 5-INCH STORZ CONNECTION FACING THE STREET (NOT BUILDING) o s / �f���p e366 y �! 1000 711 , ` . . / D ed Book 1019CPo9e 912 ...... .... 1 PIN 5�02 66 :•.•.•.•.•.....:•:•:-: . 1 � ....: i i I 1 \ 1 1 I � � � P,� sssa35z36z _ 1 ° P�ss814,Pz9'3011 1 t _ 1 1 I`I .. 1 sesoo<929z i Ali VICINITY MAP SCALE: 1 " = 2,500' PROJECT SUMMARY PROJECT NAME: TRIWEST BUSINESS CENTER - BUILDING 2 DEVELOPER/CONTRACTOR: MOCKSVILLE DEVELOPMENT PARTNERS, LLC PLANS PREPARED BY: OAK ENGINEERING, PLLC TAX PARCEL NUMBER: F500000053 ZONING: GI JURISDICTION: DAVIE COUNTY RIVER BASIN: YADKIN PEE DEE HUC: YADKIN PEE DEE FEMA INFORMATION: MAP NO. 3710584000J MAP DATE: 9/7/2008 FLOOD ZONE: IN LOT SIZE: +201.14 ACRES CONSTRUCTION DATES: 7/1 /22 - 2/2/23 DENUDED AREA: 1 13.0 ACRES (PERMITTED SEPARATELY) EXISTING BUILDING USE: N/A PROPOSED BUILDING USE: SPEC INDUSTRIAL BUILDING SIZE: 297,600-SF (1 STORY) PROPOSED FAR: 297,600-SF / 201.14 AC = 0.034 FAR REQUIRED PARKING: 1 SPACE PER 300-SF OFFICE, PLUS 1 SPACE PER EACH EMPLOYEE ON THE LARGEST SHIFT, PLUS 1 SPACE PER EACH VEHICLE IN BUSINESS USE to Q W N N � Z� LL w r z Z Ow J V O7 V � � a Q a) OZ o AncO 0 Oa �U Z 0� ::E 0 0 01 [V Z U It PE SEAL: CA Y\ '�. .• / O % • 10 I SEAL 045345 •'•:�G A NE��••• �% BUGF 02/21/2023 200 0 200 SCALE: 1 " = 200' N Z PROPOSED PARKING: 200 TOTAL SPACES (INCLUDING 6 ADA SPACES) (SUPPORTS 10% OFFICE PLUS 100 ADDITIONAL SPACES FOR InEMPLOYEES AND BUSINESS VEHICLES) DRAWING INDEX ORIGINAL LATEST LATEST SHEET SHEET TITLE DATE ISSUE REV. C1.0 COVER SHEET 6/28/22 2/21 /23 6 C1.1 PROJECT NOTES 6/28/22 1 1 /18/22 C2.0 EXISTING CONDITIONS (BY OTHERS) FOR REFERENCE ONLY C3.0 SITE PLAN 6/28/22 1 1 /18/22 C3.1 UTILITY PLAN 6/28/22 1 1 /1 8/22 2 C3.2 UTILITY PLAN 6/28/22 1 1 /1 8/22 2 C3.3 SANITARY SEWER PROFILES 6/28/22 1 1 /1 8/22 2 C4.0 GRADING & DRAINAGE PLAN 6/28/22 1 1 /18/22 C4.1 GRADING PLAN 6/28/22 1 1 /18/22 C4.2 STORM DRAINAGE PROFILES 6/28/22 1 1 /1 8/22 C4.3 STORMWATER MANAGEMENT PLAN - POND #2 6/28/22 2/21 /23 6 C4.4 STORMWATER MANAGEMENT PLAN - POND #3 1 2/21 /22 2/21 /23 6 C5.0 LANDSCAPING PLAN 6/28/22 1 1 /18/22 C6.0 PUBLIC ROAD PLAN & PROFILE 6/28/22 1 1 /1 8/22 C6.1 PUBLIC UTILITIES 6/28/22 1 1 /18/22 3 C7.0 PROJECT DETAILS 6/28/22 1 1 /1 8/22 C7.1 PROJECT DETAILS 6/28/22 1 1 /1 8/22 2 C7.3 PROJECT DETAILS 6/28/22 10/6/22 C7.4 PROJECT DETAILS 6/28/22 1 1 /1 8/22 PROJECT CONTACTS PROPERTY OWNER - - — THE CROWN COMPANIES, LLC 121 N. CRUTCHFIELD STREET DOBSON, NC 27017 336.386.9790 CONTRACTOR OMEGA CONSTRUCTION 1 100 S. STRATFORD RD., BUILDING C, SUITE 1 10 WINSTON SALEM, NC 27103 336.368.2277 DEVELOPER THE CROWN COMPANIES, LLC 121 N. CRUTCHFIELD STREET DOBSON, NC 27017 336.386.9790 SURVEYOR (BOUNDARY) JERRY W. ELLIS, PLS ENCOMPASS SURVEYING & ENGINEERING, PC 6206-B HACKER'S BEND CT. 336.893.7397 MUNICIPALITY CONTACTS PLANNING/ZONING DAVIE COUNTY 298 E. DEPOT STREET MOCKSVILLE, NC 27028 336.753.6050 NCDOT JEREMY GUY, PE NCDOT DIVISION 2, DISTRICT 9 375 SILAS CREEK PKWY WINSTON-SALEM, NC 27127 336.747.7900 STORMWATER DAVIE COUNTY 298 E. DEPOT STREET MOCKSVILLE, NC 27028 336.753.6050 ENGINEER LUKE J. BUGENSKE, PE OAK ENGINEERING, PLLC 4929 MONROE ROAD CHARLOTTE, NC 28205 704.559.9456 Juke@oak.engineering ARCHITECT MERRIMAN SCHMITT ARCHITECTS, INC. 605 LEXINGTON AVENUE CHARLOTTE, NC 28203 704.870.3101 nnanii@msacha rlotte.com EROSION CONTROL NCDEQ WINSTON SALEM OFFICE 450 WEST HANES MILL RD, STE 300 WINSTON-SALEM, NC 27105 336.776.9800 UTILITIES JOHNNY LAMBERT DAVIE COUNTY PUBLIC UTILITIES 298 E. DEPOT STREET MOCKSVILLE, NC 27028 336.751.5855 1 Q J W Z� J W oZ GGLu z r— M ova W W a�Z cn O W V = Z CL 0 0 H Lu = Z W > join p W "= VW i W >� 00 44 ca N W ce N 0 ~ N N Z w w�se oe oe 0 ::E O O J 0 ::E < Lu OV V-:1 Q Umm03O W C o �0 V w w w O a a a a N W p p 0 100 CL W W W W W D to cn cn to cn W > > > > > N W W W W W> Cie Qe oe Cie ile W oe CV CV CV n! CV N \\\\\ N Z.0N'IT 00r\ O 00770 t%f p - - - N CV Lu ca N O 01 J Lu (^ r r w 0 ,Lmm Z p 2 r Z 3W V) W Z w W O Lu 2 0 = � N V � SEEDBED PREPARATION 1. AREAS TO BE SEEDED SHALL BE RIPPED OR TILLED AND SPREAD WITH AVAILABLE TOPSOIL 4" DEEP. TOTAL SEEDBED PREPARED DEPTH SHALL BE 6". 2. ROCKS, ROOTS & OTHER OBSTRUCTIONS & CONSTRUCTION DEBRI SHALL BE REMOVED FROM THE SURFACE OF THE SEEDBED. SURFACE OF COMPLETED PREPARED SEEDBED SHALL BE LOOSE, SMOOTH AND UNIFORM. CONTRACTOR SHALL TILL, DISC AND/OR HARROW IF NECESSARY TO ACHIEVE THIS. 3. IF NO SOIL TEST IS TAKEN, FERTILIZER AND LIME SHALL BE APPLIED ACCORDING TO THE SEEING SPECIFICATIONS. 4. IF SOIL TEST IS TAKEN, APPLY FERTILIZER AND LIME IN ACCORDANCE WITH SOIL TEST RECOMMENDATIONS. 5. LIME AND FERTILIZER SHALL BE APPLIED UNIFORMLY AND MIXED WITH THE SOIL DURING SEEDBED PREPARATION. 6. IMMEDIATELY AFTER SEEDING, MUCH ALL SEEDED AREAS WITH A THIN DENSE LAYER OF CLEAN WHEAT STRAW. LANDSCAPING NOTES 1. ALL PLANTS SHALL MEET OR EXCEED THE MINIMUM STANDARDS SET FORTH IN THE AMERICAN STANDARDS FOR NURSERY STOCK BY THE AMERICAN ASSOCIATION OF NURSERYMEN, INC., WASHINGTON, D.C. 2. ALL PLANTS SHALL BE COMPACT, UNIFORM, AND WELL GROWN. PLANTS SHALL NOT BE LOOSE, OPEN PLANTS. THE CLIENT'S LANDSCAPE ARCHITECT RESERVES THE RIGHT, IN OUR SOLE OPINION, TO REJECT ANY AND ALL MATERIALS WHICH DO NOT MEET THESE REQUIREMENTS. 3. ALL PLANTING BEDS SHALL BE MULCHED A MINIMUM OF 4" WITH PINE NEEDLE MULCH. 4. ALL PLANTS SHALL BE FREE FROM DISEASE, INSECT INFESTATIONS, AND INJURIES. 5. ALL PLANT BEDS SHALL HAVE A 4" V-CUT TRENCH INSTALLED AT THE PERIMETER OF THE BED. 6. CONTRACTOR MUST PROVIDE A ONE YEAR WRITTEN GUARANTEE FOR ALL PLANT MATERIALS FROM THE DATE OF FINAL ACCEPTANCE BY THE ENGINEER / OWNER. CONTRACTOR TO PROVIDE TEMPORARY IRRIGATION AS NECESSARY UNTIL PLANTS ARE ESTABLISHED. 7. THE SPECIES, VARIETIES, AND SIZE LISTED SHALL BE PROVIDED AS SPECIFIED. SUBSTITUTIONS WILL BE PERMITTED ONLY UPON WRITTEN APPLICATION BY THE CONTRACTOR TO THE ENGINEER / OWNER, AND WHEN APPROVAL IS IN WRITING. 8. SYMBOLS: B&B = BALLED AND BURLAPPED; O.C. = ON CENTER; GAL. = GALLON CONTAINER, M.S. = MULTI -STEM; HT. = HEIGHT, CAL. = CALIPER. 9. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL PLANTS ILLUSTRATED ON THE PLANTING PLAN. IF ANY DISCREPANCIES EXIST BETWEEN THE QUANTITIES LISTED ON THE PLANT LIST AND THE QUANTITIES SHOWN ON THE PLAN, THE CONTRACTOR SHALL PROVIDE ALL QUANTITIES ILLUSTRATED ON THE PLAN. IF ANY PLANTS ARE SHOWN NOT LABELED, THE CONTRACTOR SHALL VERIFY THE PLANT IDENTITY WITH THE ENGINEER AND THESE PLANTINGS SHALL BE INCLUDED IN THE CONTRACTOR'S INITIAL BID. 10. SOIL AMENDMENTS SHALL BE UNIFORMLY SPREAD AND CULTIVATED THOROUGHLY BY A MECHANICAL TILLER INTO THE TOP 1 2" OF SOIL THROUGHOUT SHRUB BEDS. 11. THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE ENGINEER AND THE OWNER IN WRITING OF ALL SOIL CONDITIONS THE CONTRACTOR CONSIDERS DETRIMENTAL TO THE GROWTH OF PLANT MATERIALS. PROPER DRAINAGE MUST BE ASSURED. 12. ALL SIGNAGE AND SITE LIGHTING TO BE COORDINATED AROUND THE TREES LOCATED ON THE PLANTING PLAN. ALL TREES SHOWN ON THE PLANTING PLAN MUST GO IN AS SPECIFIED. ANY CHANGES TO THE PLANTING PLAN COULD RESULT IN A DELAY IN RECEIVING AND OCCUPANCY PERMIT. 13. CONSULT PLANT LIST FOR PLANT SIZES AND SPECIFICATIONS. 14. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO INSTALLATION. NOTIFY ENGINEER IF FIELD CONDITIONS WARRANT ADJUSTMENT OF PLANT LOCATIONS. 15. CONTRACTOR IS RESPONSIBLE FOR ALL PLANTS SHOWN ON PLANS. QUANTITIES ARE FOR CONVENIENCES ONLY. 16. GENERAL CONTRACTOR TO SEED ALL DISTURBED AREAS BEYOND PARKING LOT PERIMETER. LANDSCAPE CONTRACTOR SHALL SEED ALL AREAS WITHIN PARKING AS NOTED. 17. CONTRACTOR MAY CONTACT THE COUNTY INSPECTOR FOR A 02/21 /2023 MEETING TO NEGOTIATE CREDIT FOR EXISTING TREES IN THE BUFFER AREA. TREE PLANTING NOTES 1. ALL STRAPPING AND TOP 2/3 OF WIRE BASKET MUST BE CUT AWAY AND REMOVED FROM ROOT BALL PRIOR TO BACKFILLING PLANTING PIT. REMOVE TOP 1 /3 OF THE BURLAP FROM ROOT BALL. 2. FOR NEW PLANTING AREAS, REMOVE ALL PAVEMENT, GRAVEL SUB -BASE, AND CONSTRUCTION DEBRIS; REMOVE COMPACTED SOIL AND ADD 24" NEW TOPSOIL -OR- UNCOMPACT AND AMEND TOP 24" OF EXISTING SOIL TO MEET TOPSOIL/PLANTING MIX STANDARDS FOR TREES. 3. MINIMUM TREE SIZE AT PLANTING IS 2-INCH CALIPER (FOR SINGLE STEM TREES). ALL MULTI -STEM PLANTS MUST BE TREE FORM, MAXIMUM 3 TO 5 TRUNKS, AND MINIMUM 8 FEET TALL. 4. ADJUST TREE PLANTING LOCATIONS TO AVOID UNDERGROUND UTILITIES. 5. ATTENTION LANDSCAPER: NOTIFY ENGINEER OF ANY SIGN, POWER LINE, OR OTHER CONFLICTS BEFORE PLANTING NEW TREES. 6. LARGE MATURING TREES MUST BE A MINIMUM 25 TO 30 FEET FROM THE OVERHEAD DISTRIBUTION OR TRANSMISSION LINES. IF TREES CONFLICT WITH POWER LINES OR SIGNS, CALL URBAN FORESTER TO RESOLVE BEFORE PLANTING. 7. UNLESS APPROVED BY URBAN FORESTRY STAFF ALL REQUIRED TREES MUST HAVE SINGLE STEM TRUNKS WITH NO CO -DOMINANT TRUNKS OR BRANCHES. TREE TRUNKS SHALL BE STRAIGHT IN FORM AND FREE OF DAMAGE OR CRACKS. PRUNING CUTS SHALL BE CALLUSED OVER. BRANCH LENGTH SHALL BE TYPICAL FOR THE TREES AGE AND NOT BE BROKEN, DISEASED OR INJURED. ROOT FLARE SHALL BE LOCATED AT GRADE AND BE FREE FROM EXCESSIVE ADVENTITIOUS ROOT GROWTH. 8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR / LANDSCAPER TO NOTIFY THE ENGINEER OF ANY SITE CONFLICTS THAT AFFECT TREE SPECIES OR LOCATIONS PRIOR TO PLANTING TREES. UTILITY NOTES 1. DIMENSIONS TO, OR COORDINATES OF MANHOLES, VALVES, PIPELINES, ETC., ARE TO CENTERLINE UNLESS OTHERWISE NOTED. 2. THE CONTRACTOR SHALL OBTAIN & PAY FOR, PRIOR TO THE BEGINNING OF ANY WORK, ALL PERMITS & LICENSES NECESSARY TO ACCOMPLISH WORK. PERMITS CAN INCLUDE, BUT ARE NOT LIMITED TO DAVIE COUNTY ENCROACHMENT PERMIT, GRADING PERMIT, &/OR UTILITY COMPANY'S PERMIT FOR THE WORK TO BE PERFORMED ON THEIR RESPECTIVE FACILITIES. 3. ANY CONTRACTOR PERFORMING WORK ON THIS PROJECT SHALL FAMILIARIZE HIMSELF WITH THE THE JOB SITE & LOCATION OF ALL EXISTING FACILITIES & UNDERGROUND UTILITIES SHOWN OR NOT SHOWN ON THESE PLANS. THE CONTRACTOR WILL BE UNILATERALLY RESPONSIBLE FOR ANY DAMAGE DONE TO EXISTING FACILITIES OR UNDERGROUND UTILITIES THAT ARE SHOWN OR NOT SHOWN ON THESE PLANS; & IF DAMAGED, THEY SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER AT NO COST TO THE OWNER. 4. THE CONTRACTOR SHALL RE -SET ALL MANHOLE COVERS, CATCH BASIN GRATES & ANY OTHER UTILITY ACCESS COVERS TO FINISHED PAVEMENT SURFACE OR SIDEWALK GRADE. THE CONTRACTOR SHALL PROTECT UNDERGROUND UTILITIES & THEIR APPURTENANCES TO REMAIN ON SITE FROM DAMAGE DURING CONSTRUCTION OPERATIONS. 5. SEWER CLEAN -OUTS TO BE PROVIDED AT ALL BENDS ON 6" Q OR LESS LINES. CLEAN -OUTS SHALL BE PROVIDED EVERY 75' ON 4" 0 LINES AND EVERY 100' ON 6" O LINES. SEWER LATERALS TO BE PLACED AT A MINIMUM SLOPE OF 1 /4" PER FOOT ON 4" O LINES AND 1 /8" PER FOOT ON 6" O LINES. 6. WHEN WATER MAIN IS ABOVE SEWER, BUT WITH LESS THAN 18" CLEARANCE, OR WHEN THE SEWER IS ABOVE THE WATER MAIN, BOTH WATER MAIN & SEWER LINE SHALL BE CONSTRUCTED OF FERROUS MATERIALS WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A MINIMUM LATERAL DISTANCE, MEASURED AT RIGHT ANGLES TO THE SEWER, OF 1 O' ON EACH SIDE OF THE CROSSING WITH FULL SECTIONS CENTERED AT THE POINT OF CROSSING. 7. UPON COMPLETION OF CONSTRUCTION & BEFORE ACTIVATION OF SEWER LINES & WATER MAINS, THE CONTRACTOR SHALL PROVIDE AS -BUILT SURVEY INFORMATION TO THE ENGINEER. 8. ALL STANDARD NCDENR/COUNTY UTILITY SEPARATIONS MUST BE PROVIDED FOR WATER AND SEWER MAINS. 9. THERE SHALL BE NO TAPS, PIPING BRANCHES, UNAPPROVED BYPASS PIPING, HYDRANTS, FIRE DEPT. CONNECTION POINTS, OR OTHER WATER -USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANY WATER METER AND ITS REQUIRED BACKFLOW PREVENTER. 10. CONSTRUCT UTILITIES IN ACCORDANCE WITH THE REQUIREMENTS OF THE DAVIE COUNTY & THE STATE OF NORTH CAROLINA. COMPLY WITH ALL APPLICABLE HEALTH & SAFETY REQUIREMENTS. 14. VERIFY EXISTING UTILITY LOCATIONS & OTHER EXISTING FEATURES PRIOR TO CONSTRUCTION. REPORT ANY INCONSISTENCIES TO OWNER PRIOR TO BEGINNING WORK. 15. CONTRACTOR SHALL COORDINATE WITH THE UTILITY COMPANY TO RELOCATE ANY EXISTING UTILITY POLES. ALL EXISTING FACILITIES WHICH CONFLICT WITH THE IMPROVEMENTS UNDER THE SCOPE OF THIS PROJECT MUST BE RELOCATED, AND SHALL BE INCLUDED IN THE CONTRACTOR'S BID. 16. ALL ON -SITE PRIVATE WATER AND SEWER LINES TO BE MAINTAINED BY OWNER. EROSION CONTROL MAINTENANCE NOTES EROSION CONTROL MEASURES MAINTENANCE PLAN EROSION CONTROL MEASURES MAINTENANCE NOTES 1. ALL EROSION SEDIMENT CONTROL STRUCTURES SHALL BE INSPECTED AT LEAST ONCE EVERY 7 CALENDAR DAYS AND WITHIN 24 HOURS OF ANY STORM EVENT OF GREATER THAN 1 /2" RAIN IN A 24 HOUR PERIOD. A RAIN GAUGE SHALL BE MAINTAINED ON THE SITE AND A RECORD OF THE RAINFALL AMOUNTS AND DATES SHALL BE KEPT. SEE SPECIFIC MAINTENANCE FOR EACH EROSION CONTROL MEASURE. 2. A RECORD OF INSPECTIONS BY THE CONTRACTOR SHALL BE KEPT AND MADE AVAILABLE TO THE INSPECTOR UPON REQUEST. VISIBLE SEDIMENTATION FOUND OUTSIDE THE DENUDED AREA LIMITS SHALL BE RECORDED AND A BRIEF EXPLANATION KEPT WITH THE RECORDS AS TO THE MEASURES TAKEN TO CONTROL FUTURE RELEASES. ANY MEASURES TAKEN TO CLEAN UP THE SEDIMENT THAT HAS LEFT THE DENUDED AREA LIMITS SHALL ALSO BE RECORDED. 3. SEDIMENT SHALL BE REMOVED & TRAP(S)/BASIN(S) RESTORED TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA IN SUCH A MANNER THAT IT WILL NOT ERODE. 4. CLEANOUT STAKES SHALL BE PLACED IN ALL SEDIMENT BASINS AT THE LOW POINT IN THE BASIN. THE STAKES SHALL BE MARKED SHOWING THE HALF FULL (CLEANOUT POINT) OF THE BASIN. 5. SEDIMENT BASINS SHALL BE STABILIZED IMMEDIATELY AFTER INSTALLATION. IF STABILIZATION IS INTERRUPTED DURING MAINTENANCE WORK, CONTRACTOR SHALL WORK TO RE-ESTABLISH STABILIZATION IMMEDIATELY. PERMANENT SEEDING SCHEDULE LATE WINTER / EARLY SPRING SEEDING DATES: 2/15 TO 4/15 SEEDING MIXTURE: SLOPES 3:1 AND OVER: - 258 LBSACRE / TALL FESCUE - 258 LBS/ACRE TALL FESCUE**SERICEA LESPEDEZA* - 90 LBS/ACRE KOBE LESPEDEZA* - 30 LBS/ACRE SUMMER SEEDING DATES: 4/15 TO 8/15 SLOPES 3:1 AND OVER: SEEDING MIXTURE: TALL FESCUE** - 258 LBS/ACRE TALL FESCUE - 215 LBS/ACRE SERICEA LESPEDEZA* - 90 LBS/ACRE HULLED BERMUDA GRASS - 43 LBS/ACRE KOBE LESPEDEZA* - 30 LBS/ACRE FALL SEEDING DATES: 8/15 TO 10/15 SEEDING MIXTURE: TALL FESCUE - 80 LBS/ACRE (OVERSEED WITH 15 LBS/ACRE KOBE LESPEDEZA* MIN. OF ONE TIME) NOTE: OVER SEEDING IS PART OF THE BASE BID AND THERE SHALL BE NO SEPARATE PAYMENT NOTES: EFFECTIVE OCTOBER 1, 2010, PERSONS RESPONSIBLE FOR LAND DISTURBING ACTIVITIES MUST INSPECT THE SEDIMENT AND EROSION CONTROL MEASURES ON A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED SEDIMENT & EROSION CONTROL PLAN IS BEING FOLLOWED. SELF -INSPECTION REPORTS ARE REQUIRED. A SAMPLE SELF -INSPECTION REPORT, AS WELL AS DETAILS OF THE SELF -INSPECTION PROGRAM, CAN BE FOUND ON THE LAND QUALITY WEBSITE: HTTPS://DEQ.NC.GOV/ABOUT/DIVISIONS/ENERGY-MINERAL-LAND-RESOURCES AS A MINIMUM, THE INSPECTIONS SHALL BE PERFORMED AFTER EACH OF THE FOLLOWING PHASES OF A PLAN: 1. INSTALLATION OF PERIMETER EROSION AND SEDIMENT CONTROL MEASURES 2. INSTALLATION OF SEDIMENT TRAPS/BASINS 3. CLEARING AND GRUBBING OF EXISTING GROUND COVER 4. COMPLETION OF ANY PHASE OF GRADING THAT REQUIRES PROVISION OF STABILIZATION 5. INSTALLATION OF MEASURES DURING ANY PHASE OF THE PROJECT 6. COMPLETION OF CONSTRUCTION OR DEVELOPMENT 7. INSTALLATION OF STORMWATER RETENTION MEASURES 8. QUARTERLY UNTIL THE ESTABLISHMENT OF PERMANENT GROUND COVER IS FULLY ESTABLISHED SOIL AMMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LBS/ACRE GROUND AGRICULTURAL LIMESTONE AND 1000 LBS/ACRE 10-10-10 FERTILIZER MULCH: APPLY 4,000 LBS/ACRE THRESHED WHEAT OR OAT STRAW. ANCHOR BY TACKING WITH EMULSIFIED ASPHALT, NETTING OR A MULCH ANCHORING TOOL (EMULSIFIED ASPHALT TACK RATE: 400 GAL/ACRE). A DISK WITH BLADES SET AT NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: SEE SEED/SOD MAINTENANCE NOTES SOIL AMMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LBS/ACRE GROUND AGRICULTURAL LIMESTONE AND 1000 LBS/ACRE 10-10-10 FERTILIZER MULCH: APPLY 4,000 LBS/ACRE THRESHED WHEAT OR OAT STRAW. ANCHOR BY TACKING WITH EMULSIFIED ASPHALT, NETTING OR A MULCH ANCHORING TOOL (EMULSIFIED ASPHALT TACK RATE: 400 GAL/ACRE). A DISK WITH BLADES SET AT NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: SEE SEED/SOD MAINTENANCE NOTES SOIL AMMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LBS/ACRE PELLETIZED DOLOMITIC LIMESTONE AND 1000 LBS/ACRE 10-10-10 FERTILIZER SLOPES 3:1 AND OVER: TALL FESCUE** - 258 LBS/ACRE SERICEA LESPEDEZA* - 90 LBS/ACRE KOBE LESPEDEZA - 30 LBS ACRE / MULCH: APPLY 4,000 LBS/ACRE THRESHED WHEAT OR OAT STRAW. ANCHOR BY TACKING WITH EMULSIFIED ASPHALT, NETTING OR A MULCH ANCHORING TOOL (EMULSIFIED ASPHALT TACK RATE: 400 GAL/ACRE). A DISK WITH BLADES SET AT NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: SEE SEED/SOD MAINTENANCE NOTES * APPROVED ALTERNATIVES INCLUDE SWITCHGRASS (PANICUM VIRGATUM), SPLITBEARD BLUESTREAM (ANDROPOGON TERNARIUS), OR PARTRIDGE PEA (CHAMAECRISTA FASCICULATA). ** APPROVED ALTERNATIVES INCLUDE SWITCHGRASS (PANICUM VIRGATUM), BIG BLUESTEM (ANDROPOGON GERARDII), LITTLE BLUESTEM (SCHIZACHYRIUM SCOPARIUM), INDIAN GRASS (SORGHASTRUM NUTANS), BEAKED PANICGRASS (PANICUM ANCEPS), PURPLETOP (TRIDENS FLAVUS), BROOMSEDGE (ANDROPOGON VIRGINICUS), DEER TONGUE (DICANTHELIUM CLANDESTINUM), CANADIAN WILDRYE (ELYMUS CANADENSIS), VIRGINIA WILDRYE (ELYMUS VIRGINICUS), SENSITIVE PARTRIDGE PEA (CHAMAECRISTA NICTITANS), AND PARTRIDGE PEA (CHAMAECRISTA FASCICULATA). 1. SUBSTITUTIONS WILL BE PERMITTED ONLY UPON WRITTEN APPLICATION BY THE CONTRACTOR TO THE ENGINEER, AND WHEN APPROVED BY SAID ENGINEER IN WRITING. 2. ALL SEED SHALL HAVE A 98% MINIMUM PURITY, 85% MINIMUM GERMINATION, AND BE FREE OF NOXIOUS WEED. SEED OVER ONE YEAR OLD, OR OTHERWISE DAMAGED, WILL NOT BE ACCEPTED. 3. ALL OTHER SITE WORK REQUIRED BY THIS CONTRACT, IN THE AREA TO BE SEEDED, SHALL BE COMPLETE AND IN PLACE BEFORE GRASSING OPERATIONS ARE BEGUN. WORK MAY BE COMPLETED IN PARTS IF SO REQUESTED BY THE CONTRACTOR AND APPROVED BY THE OWNER OR ENGINEER. 4. PROTECTIVE COVER MUST BE ESTABLISHED ON ALL DISTURBED AREAS, GRADED SLOPES AND FILLS WITHIN 21 CALENDAR DAYS AFTER LAND DISTURBING ACTIVITY IS COMPLETED OR HAS TEMPORARILY CEASED. 5. FOR ADDITIONAL INFORMATION, INCLUDING SEED BED PREP, SEASONAL LIMITATIONS FOR SEEDING OPERATIONS, THE KINDS OF GRADES OF FERTILIZERS, THE KINDS OF SEED, AND THE RATES OF APPLICATION OF LIMESTONE, FERTILIZER, AND SEED, REFER TO NCDENR ESCPDM SECTION 6.1 1. SEDIMENT BASIN CONSTRUCTION SPECIFICATIONS 1. SITE PREPARATIONS- CLEAR GRUB AND STRIP TOPSOIL FROM AREAS UNDER THE EMBANKMENT TO REMOVE TREES VEGETATION ROOTS AND OTHER OBJECTIONABLE MATERIAL. DELAY CLEARING THE POOL AREA UNTIL THE DAM IS COMPLETE AND THEN REMOVE BRUSH, TREES, AND OTHER OBJECTIONABLE MATERIALS TO FACILITATE SEDIMENT CLEANOUT. STOCKPILE ALL TOPSOIL OR SOIL CONTAINING ORGANIC MATTER FOR USE ON THE OUTER SHELL OF THE EMBANKMENT TO FACILITATE VEGETATIVE ESTABLISHMENT. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW THE BASIN AS NEEDED. 2. CUT-OFF TRENCH EXCAVATE A CUT-OFF TRENCH ALONG THE CENTER LINE OF THE EARTH FILL EMBANKMENT. CUT THE TRENCH TO STABLE SOIL MATERIAL BUT IN NO CASE MAKE IT LESS THAN 2 FEET DEEP. THE CUT-OFF TRENCH MUST EXTEND INTO BOTH ABUTMENTS TO AT LEAST THE ELEVATION OF THE RISER CREST. MAKE THE MINIMUM BOTTOM WIDTH WIDE ENOUGH TO PERMIT OPERATION OF EXCAVATION AND COMPACTION EQUIPMENT, BUT IN NO CASE LESS THAN 2 FEET. MAKE SIDE SLOPES OF THE TRENCH NO STEEPER THAN 1:1. COMPACTION REQUIREMENTS ARE THE SAME AS THOSE FOR THE EMBANKMENT. KEEP THE TRENCH DRY DURING BACKFILLING AND COMPACTION OPERATIONS 3. EMBANKMENT - TAKE FILL MATERIAL FROM THE APPROVED AREAS SHOWN ON THE PLANS. IT SHOULD BE CLEAN MINERAL SOIL, FREE OF ROOTS, WOODY VEGETATION, ROCKS, AND OTHER OBJECTIONABLE MATERIAL. SCARIFY AREAS ON WHICH FILL IS TO BE PLACED BEFORE PLACING FILL THE FILL MATERIAL MUST CONTAIN SUFFICIENT MOISTURE SO IT CAN BE FORMED BY HAND INTO A BALL WITHOUT CRUMBLING. IF WATER CAN BE SQUEEZED OUT OF THE BALL, IT IS TOO WET FOR PROPER COMPACTION. PLACE FILL MATERIAL IN 6 TO 8 INCH CONTINUOUS LAYERS OVER THE ENTIRE LENGTH OF THE FILL AREA AND COMPACT IT. COMPACTION MAY BE OBTAINED BY ROUTING THE CONSTRUCTION HAULING EQUIPMENT OVER THE FILL SO THAT THE ENTIRE SURFACE OF EACH LAYER IS TRAVERSED BY AT LEAST ONE WHEEL OR TREAD TRACK OF HEAVY EQUIPMENT, OR A COMPACTOR MAY BE USED. CONSTRUCT THE EMBANKMENT TO AN ELEVATION 10 PERCENT HIGHER THAN THE DESIGN HEIGHT TO ALLOW FOR SETTLING. 4. CONDUIT SPILLWAYS- SECURELY ATTACH THE RISER TO THE BARREL OR BARREL STUB TO MAKE A WATERTIGHT STRUCTURAL CONNECTION. SECURE ALL CONNECTIONS BETWEEN BARREL SECTIONS BY APPROVED WATERTIGHT ASSEMBLIES. PLACE THE BARREL AND RISER ON FIRM SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE AS BACKFILL AROUND THE PIPE OR ANTI -SEEP COLLARS. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4-INCH LAYERS, AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM FIRM CONTACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. ANCHOR THE RISER IN PLACE BY CONCRETE OR OTHER SATISFACTORY MEANS TO PREVENT FLOTATION. IN NO CASE SHOULD THE PIPE CONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS COMPLETE. 5. EMERGENCY SPILLWAY- INSTALL THE EMERGENCY SPILLWAY IN UNDISTURBED SOIL. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE EMERGENCY SPILLWAY. 6. INLETS- DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT -LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY 7. EROSION CONTROL- CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENT BEFORE THE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION . 8. INSTALL POROUS BAFFLES AS SPECIFIED IN DETAILS. ALL EROSION & SEDIMENTATION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH HEAVY RUNOFF RAINFALL. ALL MEASURES SHALL COMPLY WITH NCDEQ REGULATIONS. CONTRACTOR TO COORDINATE ALL INSTALLATION AND INSPECTIONS WITH NCDEQ EROSION CONTROL INSPECTOR. EROSION CONTROL MEASURES TO BE INSPECTED INCLUDE: TEMPORARY SEDIMENT BASINS INSPECT TEMPORARY SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1 /2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN IT ACCUMULATES TO ONE-HALF THE DESIGN DEPTH. PLACE REMOVED SEDIMENT IN AN AREA WITH SEDIMENT CONTROLS. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE RISER AND POOL AREA. REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE -ANCHOR THE BAFFLES IF WATER IS FLOWING UNDERNEATH OR AROUND THEM. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLY JERKING ON THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THE FLOW DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE IF IT IS CLOGGED; IF SO REMOVE DEBRIS. IF THE SKIMMER ARM OR BARREL PIP IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. CHECK THE SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH FABRIC THAT SPANS THE FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. SILT FENCE INSPECT SILT FENCE AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SILT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. CHECK DAMS ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE CHECK DAM AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS BETWEEN DAMS, INSTALL A PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL. REMOVE SEDIMENTATION ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE OR WATTLE CHECK DAM AND TO PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE DAM. ADD STONE OR ADDITIONAL WATTLES AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION. DIVERSION DITCHES CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED TO AVOID GULLY FORMATION. WHEN THE AREA ABOVE THE TEMPORARY DIVERSION DITCH IS PERMANENTLY STABILIZED, REMOVED THE DIKE AND FILL AND STABILIZE THE CHANNEL TO BLEND WITH THE NATURAL SURFACE. OUTLET PROTECTION INSPECT RIPRAP OUTLET STRUCTURES AFTER HEAVY RAINS TO SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. CONSTRUCTION ENTRANCE MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH 2" STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED OR TRACKED ONTO PUBLIC ROADS. SEEDING RESEED AREAS WHERE SEEDING EMERGENCE IS POOR OR WHERE EROSION OCCURS AS SOON AS POSSIBLE. CONCRETE WASHOUT MAINTAIN CONCRETE WASHOUT STRUCTURE(S) TO PROVIDE ADEQUATE HOLDING CAPACITY PLUS A MINIMUM FREEBOARD OF 18 INCHES. REMOVE AND DISPOSE OF HARDENED CONCRETE AND RETURN THE STRUCTURE TO A FUNCTIONAL CONDITION AFTER REACHING 75% CAPACITY. INSPECT CONCRETE WASHOUT STRUCTURES FOR DAMAGE AND MAINTAIN FOR EFFECTIVENESS. REMOVE THE CONCRETE WASHOUT STRUCTURES AND SIGN UPON PROJECT COMPLETION. GRADE THE EARTH MATERIAL TO MATCH THE EXISTING CONTOURS AND PERMANENTLY SEED AND MULCH AREA. STOCKPILES CHECK STOCKPILES FOR SILT FENCE EFFICIENCY, SEDIMENTATION AND STABILIZATION. INLET PROTECTION INSPECT INLET PROTECTION AFTER EACH RAINFALL EVENT AND MAKE NEEDED REPAIRS IMMEDIATELY. REMOVE SEDIMENT FROM POOL AREA TO PROVIDE STORAGE FOR THE NEXT RAIN EVENT. AVOID DAMAGING OR UNDERCUTTING THE FABRIC DURING SEDIMENT REMOVAL. WHEN CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, INSPECTED AND APPROVED, REMOVE ALL CONSTRUCTION MATERIAL AND ANY UNSTABLE SEDIMENT AND DISPOSE OF THEM PROPERLY. GRADE THE DISTURBED AREA TO THE ELEVATION OF THE DROP INLET CREST. STABILIZE ALL BARE AREAS IMMEDIATELY. SLOPE DRAINS INSPECT THE SLOPE DRAINS AND SUPPORTING DIVERSION AFTER EVERY RAINFALL AND PROMPTLY MAKE NECESSARY REPAIRS. WHEN THE PROTECTED AREA HAS BEEN PERMANENTLY STABILIZED, TEMPORARY MEASURES MAY BE REMOVED MATERIALS DISPOSED OF PROPERLY AND ALL DISTURBED AREAS STABILIZED APPROPRIATELY. BAFFLES SEE SEDIMENT BASINS SILT BAGS INSPECT SILT BAGS WHILE DEWATERING IS ONGOING. REPLACE SILT BAGS WHEN TRAPPED SEDIMENT HAS ACCUMULATED TO 50% OF THE BAG CAPACITY OR IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. DEWATERING BAGS ARE FULL WHEN THEY NO LONGER EFFICIENTLY FILTER SEDIMENT OR PASS WATER AT A REASONABLE RATE. EROSION CONTROL BLANKETS INSPECT ROLLED EROSION CONTROL PRODUCTS (RECP) AT LEAST WEEKLY AND AFTER SIGNIFICANT (1 /2 INCH OR GREATER) RAINFALL EVENT - REPAIR IMMEDIATELY. GOOD CONTACT WITH THE GROUND MUST BE MAINTAINED, AND EROSION MUST NOT OCCUR BENEATH RECP. ANY AREAS OF THE RECP THAT ARE DAMAGED OR NOT IN CLOSE CONTACT WITH THE GROUND SHALL BE REPAIRED AND STAPLED. IF EROSION OCCURS DUE TO POORLY CONTROLLED DRAINAGE, THE PROBLEM SHALL BE FIXED AND THE ERODED AREA PROTECTED. MONITOR AND REPAIR THE RECP AS NECESSARY UNTIL GROUND COVER IS ESTABLISHED. GENERAL EROSION CONTROL NOTES 1. ON -SITE BURIAL PITS REQUIRE AN ON -SITE DEMOLITION LANDFILL PERMIT FROM THE ZONING ADMINISTRATOR AND THE DIVISION OF WASTE MANAGEMENT, SOLID WASTE SECTION. 2. ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF THE EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE. 3. GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION OF THE CITY/COUNTY EROSION CONTROL ORDINANCE & IS SUBJECT TO A FINE. 4. ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3:1 (H:V) SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTIBLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS FROM THE LAST LAND -DISTURBING ACTIVITY. ALL OTHER DISTURBED AREAS SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT WITH 14 CALENDAR DAYS FROM THE LAST LAND -DISTURBING ACTIVITY. 5. ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY A REPRESENTATIVE OF THE COUNTY OR STATE ENGINEERING DEPARTMENT. 6. SLOPES SHALL BE GRADED NO STEEPER THAN 2:1. SOILS ENGINEER TO VERIFY STABILITY OF SLOPES GREATER THAN 2:1. 7. TEMPORARY DRIVEWAY PERMIT FOR CONSTRUCTION ENTRANCES IN NCDOT RIGHT-OF-WAY MUST BE PRESENTED AT PRE -CONSTRUCTION MEETING. 8. ALL EMBANKMENTS MUST BE CONSTRUCTED PER SECTION 4.0.6 EMBANKMENT REQUIREMENTS IN THE BMP DESIGN MANUAL. (IF APPLICABLE). 9. STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING IS NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS AND ESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTION SEQUENCE SHOWN ON THE PLAN. GENERAL GRADING NOTES 1. CONTACT THE DAVIE COUNTY EROSION CONTROL OFFICE AT LEAST 48 HOURS PRIOR TO COMMENCING THE LAND -DISTURBING ACTIVITY. 2. THE CONTRACTOR SHALL MAINTAIN EACH STREAM, CREEK, OR BACKWASH CHANNEL IN AN UNOBSTRUCTED STATE AND SHALL REMOVE FROM THE CHANNEL AND BANKS OF THE STREAM ALL DEBRIS, LOGS, TIMBER, JUNK AND OTHER ACCUMULATIONS. 3. PE SEALED SHOP DRAWINGS FOR RETAINING WALL(S) MUST BE SUBMITTED TO CITY/COUNTY ENGINEER PRIOR TO CONSTRUCTION. 4. APPROVAL OF THIS SITE PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. 5. ANY OFF -SITE BORROW AND WASTE REQUIRED FOR THIS PROJECT MUST COME FROM A SITE WITH AN APPROVED EROSION CONTROL PLAN. 6. IN ORDER TO ENSURE PROPER DRAINAGE, KEEP A MINIMUM OF 0.5% SLOPE ON THE CURB. 7. CONTRACTOR TO SAVE SUFFICIENT TOPSOIL ON SITE TO BE RE -SPREAD AFTER GRADING IS COMPLETE. HAUL OFF ANY EXCESS TOPSOIL. NCDENR GROUND COVER REQUIREMENTS NEW STABILIZATION TIMEFRAMES {Effective Aug. 3, 20111 SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS rr�\ � I I 1 Perimeter dikes, swales, ditches, slopes 7 days None c3 High Quality Water (HOW) Zones 7 days None Slopes steeper than 3:1 7 days ''slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed. Slopes 3:1 or flatter 14 days 7 days for slopes greater than 50' in length. OAll other areas with slopes flatter than 4:1 14 days None, except for perimeters and HOW Zones. PERMANENT SEEDING AS NEEDED 1. AREA TO BE STABILIZED WITH PERMANENT SEEDING: AREAS NOT DISTURBED BY THE DAY-TO-DAY ACTIVITIES. 2. CONTROL RUNOFF AND EROSION ON DISTURBED AREAS BY ESTABLISHING PERENNIAL VEGETATIVE COVER WITH SEED. 3. REDUCE EROSION AND DECREASE SEDIMENT YIELD FROM DISTURBED AREAS. PERMANENTLY STABILIZE SUCH AREAS IN A MANNER THAT IS ECONOMICAL, ADAPTS TO SITE CONDITIONS, AND ALLOWS SELECTION OF THE MOST APPROPRIATE PLANT MATERIALS. 4. FINE -GRADED AREAS ON WHICH PERMANENT, LONG-LIVED VEGETATIVE COVER IS THE MOST PRACTICAL OR MOST EFFECTIVE METHOD OF STABILIZING THE SOIL. PERMANENT SEEDING MAY ALSO BE USED ON ROUGH -GRADED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE FOR A YEAR OR MORE. 5. TEST AND ANALYZE THE TYPE(S) AND QUALITY OF THE EXISTING SOILS ON A SITE, THEIR PH RANGES, AND THEIR NUTRIENT LEVELS. TAKING SOIL SAMPLES FROM THE DIFFERENT AREAS OF THE PROJECT SITE AND HAVING THEM TESTED AT A STATE OR INDEPENDENT LAB WILL PROVIDE A BASELINE FOR DETERMINING THE PH MODIFIERS AND ADDITIONAL NUTRIENTS REQUIRED FOR THE SELECTED PLANT VARIETIES. 6. DISTURBED CONDITIONS ON A SITE MAY PRODUCE A VARIETY OF SOIL COMMUNITIES. NUTRIENT AND PH LEVELS IN DEEPLY CUT SOILS WILL BE QUITE DIFFERENT FROM THOSE SOILS FOUND ON THE ORIGINAL SURFACE. WHEN SITES ARE HIGHLY DISTURBED THROUGH MECHANICAL MEANS SUCH AS GRADING, THE SOILS BECOME MIXED TOGETHER IN MANY DIFFERENT RATIOS. THESE AREAS SHOULD BE IDENTIFIED AND TESTED. RESULTS FROM SOIL TESTS WILL USUALLY INCLUDE RECOMMENDED APPLICATION RATES OF SOIL MODIFIERS SUCH AS LIME AND FERTILIZER FOR THE SELECTED PLANT SPECIES IN THE PARTICULAR SOILS. APPLICATION RATES WILL BE ITEMIZED IN THE REPORT. THE TEXTURE OF THE SOIL ON A SITE, WHICH IS THE PROPORTION OF SAND, SILT, AND CLAY IN THE SOIL, IS AN IMPORTANT PHYSICAL INDICATOR OF THE SITE'S ABILITY TO SUPPORT VEGETATION. IN HEAVY CLAY SOILS, AMENDMENTS MAY BE NECESSARY TO PROVIDE AN ADEQUATELY DRAINED PLANTING MEDIUM. CONVERSELY, IN EXTREMELY SANDY SOILS, AMENDMENTS MAY BE REQUIRED TO PROVIDE FOR MOISTURE AND NUTRIENT RETENTION. 7. PREPARATION FOR PRIMARY/PERMANENT STABILIZATION SHALL NOT BEGIN UNTIL ALL CONSTRUCTION AND UTILITY WORK WITHIN THE PREPARATION AREA IS COMPLETE. HOWEVER, IT MAY BE NECESSARY TO PREPARE FOR NURSE CROPS PRIOR TO COMPLETION OF CONSTRUCTION AND INSTALLATION OF UTILITIES. 8. A NORTH CAROLINA DEPARTMENT OF AGRICULTURE SOILS TEST (OR EQUAL) SHALL BE OBTAINED FOR ALL AREAS TO BE SEEDED, SPRIGGED, SODDED OR PLANTED. RECOMMENDED FERTILIZER AND PH ADJUSTING PRODUCTS SHALL BE INCORPORATED INTO THE PREPARED AREAS AND BACKFILL MATERIAL PER THE TEST. 9. ALL AREAS TO BE SEEDED OR PLANTED SHALL BE TILLED OR RIPPED TO A DEPTH SPECIFIED ON THE APPROVED PLANS, CONSTRUCTION SEQUENCE AND/OR CONSTRUCTION BID LIST. RIPPING CONSISTS OF CREATING FISSURES IN A CRISS-CROSS PATTERN OVER THE ENTIRE SURFACE AREA UTILIZING AN IMPLEMENT THAT WILL NOT GLAZE THE SIDEWALLS OF THE FISSURES. SITE PREPARATION THAT DOES NOT COMPLY WITH THESE DOCUMENTS SHALL NOT BE ACCEPTABLE. THE DEPTH OF SOIL PREPARATION MAY ESTABLISHED AS A RANGE BASED ON THE APPROVAL OF THE REVIEWING STATE OR LOCAL AGENCY. ONCE TILLED OR RIPPED ACCORDING TO THE APPROVED PLAN, ALL AREAS ARE TO BE RETURNED TO THE APPROVED FINAL GRADE. PH MODIFIERS AND/OR OTHER SOIL AMENDMENTS SPECIFIED IN THE SOIL TESTS CAN BE ADDED DURING THE SOIL PREPARATION PROCEDURE OR AS DESCRIBED BELOW. 10. ALL STONES LARGER THAN THREE (3) INCHES ON ANY SIDE, STICKS, ROOTS, AND OTHER EXTRANEOUS MATERIALS THAT SURFACE DURING THE BED PREPARATION SHALL BE REMOVED. 11. TILL OR DISC THE PREPARED AREAS TO BE SEEDED TO A MINIMUM DEPTH OF FOUR (4) INCHES. IF NOT INCORPORATED DURING THE SOIL PREPARATION PROCESS, ADD PH MODIFIER AND FERTILIZERS AT THE RATE SPECIFIED IN THE SOIL TEST REPORT. 12. RE -COMPACT THE AREA UTILIZING A CULTIPACKER ROLLER. THE FINISHED GRADE SHALL BE A SMOOTH EVEN SOIL SURFACE WITH A LOOSE, UNIFORMLY FINE TEXTURE. ALL RIDGES AND DEPRESSIONS SHALL BE REMOVED AND FILLED TO PROVIDE THE APPROVED SURFACE DRAINAGE. SEEDING OF GRADED AREAS IS TO BE DONE IMMEDIATELY AFTER FINISHED GRADES ARE OBTAINED AND SEEDBED PREPARATION IS COMPLETED. 13. VEGETATION STABILIZATION (3 TYPES) 13.1. IMMEDIATE STABILIZATION - NURSE CROP VARIETIES (NOTE: TEMPORARY MULCHING MAY BE UTILIZED FOR IMMEDIATE STABILIZATION IF OUTLINED ON THE APPROVED PLANS AND CONSTRUCTION SEQUENCE.) 13.2. PRIMARY STABILIZATION - PLANT VARIETIES PROVIDING COVER UP TO THREE (3) YEARS WITH A SPECIFIED MAINTENANCE PLAN. 13.3. LONG TERM STABILIZATION - PLANT VARIETIES PROVIDING PROTECTIVE COVER WITH MAINTENANCE LEVELS SELECTED BY THE OWNER. AN ADEQUATE JOB IN ONE OF THESE AREAS DOES NOT GUARANTEE SUCCESS IN THE LATER PHASES. IMMEDIATE VEGETATIVE COVER WILL ALWAYS REQUIRE ADDITIONAL FERTILIZATION, SOIL AMENDMENTS, SOIL TESTS, OVERSEEDING, AND/OR OTHER HORTICULTURAL MAINTENANCE UNTIL PRIMARY VEGETATIVE COVER IS ESTABLISHED. 14. IF NO SOIL TEST IS AVAILABLE, FOLLOW THESE RECOMMENDATIONS FOR ALL GRASSES EXCEPT CENTIPEDEGRASS: 14.1. APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE. 14.2. APPLY A STARTER TYPE FERTILIZER (ONE THAT IS HIGH IN PHOSPHORUS) BASED ON THE TYPE OF GRASS AND PLANTING METHOD. 15. FERTILIZERS REQUIRED FOR A 1,000 SQ. FT. AREA INCLUDE 40 POUNDS OF 5-10-10, 20 POUNDS OF 9-20-20, OR 16 POUNDS OF 18-24-6. FOR SANDY SOILS, TYPICAL TO COASTAL PLAIN AND SANDHILLS OF NORTH CAROLINA, FERTILIZER RATES SHOULD BE INCREASED BY 20 PERCENT. MATERIALS PROPOSED FOR USE MUST BE INDUSTRY CERTIFIED AND/OR PRIVATELY TESTED AND CERTIFIED TO BE ACCEPTABLE FOR PROPOSED AREAS OF USE AND APPLICATION PRIOR TO APPROVAL. 16. INFORMATION IS PROVIDED IN THE STATE'S EROSION CONTROL MANUAL FOR SEEDING RATES, OPTIMUM PLANTING DATES IN THE STATE'S THREE (3) REGIONS, SUN AND SHADE TOLERANCES, INVASIVE CHARACTERISTICS, COMPATIBILITY IN WETLANDS AND RIPARIAN BUFFERS, AND INSTALLATION MAINTENANCE CONSIDERATION. 17. TO USE THE INFORMATION IN THE SEEDING CHARTS FOUND IN THE STATE EROSION CONTROL MANUAL, FOLLOW THESE STEPS: 17.1. DETERMINE WHAT NURSE CROP BEST FITS THE SITE, SOIL CONDITIONS, AND PERMANENT SEED MIX. 17.2. OBTAIN SOIL TESTS FOR ALL AREAS TO BE SEEDED. 17.3. SELECT THE SITE'S REGION: MOUNTAINS, PIEDMONT, OR COASTAL PLAIN. 17.4. SELECT SUNNY, PART SHADE, OR FULL SHADE. 17.5. SELECT WELL OR POORLY DRAINED. 17.6. AVOID A CROP THAT IS INVASIVE AND IF NECESSARY, DETERMINE POTENTIAL IMPACTS ON THE SITE AND ADJACENT PROPERTIES. GENERAL NOTES 1. ALL CONCRETE SIDEWALKS SHALL BE FULL 4" THICK 3600 PSI CONCRETE W/1" DEEP GROOVE CONTROL JOINTS AT INTERVALS INDICATED ON SITE PLAN. PROVIDE EXPANSION JOINTS ADJACENT TO ALL RIGID STRUCTURES. EXPANSION JOINT SPACING SHALL NOT EXCEED 301 . 2. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 3. SEE ARCHITECTURAL PLAN FOR EXACT LOCATION & SIZE OF WATER, SEWER CONNECTIONS & ROOF DOWNSPOUTS. 4. SEE ARCHITECTURAL PLAN FOR BUILDING DIMENSIONS, FEATURES, STAIRS & HANDRAILS, ETC. 5. DRIVEWAYS SHALL BE CONSTRUCTED TO STATE & LOCAL CODES. 6. ACCESSIBLE PARKING: a. AN ACCESSIBLE PARKING SPACE SHALL HAVE NO GREATER SLOPE THAN 1 /A" PER FOOT ACROSS THE SPACE. b. HANDRAILS ARE TO BE PROVIDED ON ACCESSIBLE RAMPS WITH A DROP OF 2" OR MORE. c. MAX. SLOPE FOR AN ACCESSIBLE ROUTE (SIDEWALK) SHALL BE 5.0% (1:20). d. ALL ACCESSIBLE PARKING SPACES SHALL DISPLAY APPROVED RESERVED PARKING SPACE SIGNS AS PRESCRIBED BY THE N.C.D.O.T. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES & APPROVED FOR USE UNDER N.C. GENERAL STATUTE R7-8, R7-8D "PENALTY" SIGN & HERE APPLICABLE, "VAN ACCESSIBLE" SIGN. 7. THE CONTRACTOR SHALL VISIT THE SITE & FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. 8. ALL DISTANCES & DATA SHALL BE CHECKED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION, IN CASE OF CONFLICT, THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY SO THAT CLARIFICATIONS MAY BE MADE PRIOR TO THE START OF WORK. 9. THE PROPOSED GRADES AS SHOWN ARE THE FINISH GRADES UNLESS OTHERWISE NOTED. 10. LIGHTING SHALL NOT EXCEED WIN HEIGHT. 11. THE CONTRACTOR SHALL SUPPLY & ESTABLISH SURVEY CONTROL, INCLUDING THE HORIZONTAL & VERTICAL CONTROL POINTS. THE CONTRACTOR SHALL MAINTAIN THIS CONTROL & PROVIDE ALL BENCHMARKS, STAKES, GRADES, LEVELS, & LINES NECESSARY FOR CONSTRUCTION. CONTRACTORS SHALL PROVIDE ADEQUATE SUPERVISION TO PREVENT () Q DAMAGE & MOVEMENT FROM EQUIPMENT WORKING AROUND CONSTRUCTION STAKES. THESE CONSTRUCTION STAKES SHALL REMAIN IN PLACE & BE PROTECTED UNTIL OWNER APPROVES THEIR REMOVAL. ANY STAKES THAT HAVE BEEN DISPLACED AS A RESULT OF CONSTRUCTION ACTIVITY ARE TO BE REPLACED BY A LICENSED LAND SURVEYOR ENGAGES BY THE CONTRACTOR AT NO COST TO THE OWNER. 12. ALL EXISTING IMPROVEMENTS DAMAGED AS A RESULT OF CONSTRUCTION OPERATIONS SHALL BE RESTORED TO THEIR ORIGINAL CONDITION TO THE SATISFACTION OF THE OWNER. 13. ALL EXISTING PAVEMENT & CONCRETE TO BE JOINED SHALL BE SAWCUT. 14. BURNING ON, OR NEAR THE JOB SITE WILL NOT BE PERMITTED. 15. ALL FILL SHALL BE COMPACTED TO 95% PER ASTM D 698. UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL CLEAN THE ENTIRE SITE OF ALL CONSTRUCTION RELATED MATERIAL & DEBRIS. 16. THE SITE WORK CONTRACTOR(S) SHALL BE FAMILIAR WITH & OBSERVE THE APPLICABLE TREE SAVE REQUIREMENTS. ANY QUESTIONS SHOULD BE DIRECTED TO THE PROJECT CIVIL ENGINEERING REPRESENTATIVE. 17. LAND DEVELOPMENT ENGINEER TO BE GIVEN 24 HOURS NOTICE PRIOR TO START OF CONSTRUCTION. 18. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ON ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFFSITE GRADING, WRITTEN PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER(S). 19. COORDINATE ALL CURB & STREET GRADES IN INTERSECTION WITH CITY INSPECTOR. 20. IN ORDER TO ENSURE PROPER DRAINAGE, KEEP A MINIMUM SLOPE OF 0.5% ON CURB. 21. INSTALL ALL EROSION CONTROL MEASURES PRIOR TO START OF CONSTRUCTION. THE LOCATION OF EXISTING UTILITIES, STORM DRAINAGE STRUCTURES & OTHER ABOVE & BELOW -GRADE IMPROVEMENTS ARE APPROXIMATELY AS SHOWN. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT LOCATION, SIZE & INVERT ELEVATIONS OF SUCH PRIOR TO START OF CONSTRUCTION. 22. THE DEVELOPER SHALL MAINTAIN EACH STREAM, CREEK, OR BACKWASH CHANNEL IN AN UNOBSTRUCTED STATE & SHALL REMOVE FROM THE CHANNEL ALL DEBRIS, LOGS, TIMBER, JUNK & OTHER ACCUMULATIONS. 23. ANY ROAD IMPROVEMENTS AT US HWY 158 ARE TO BE COORDINATED WITH THE NORTH CAROLINA DEPT. OF TRANSPORTATION PRIOR TO CONSTRUCTION. 24. THE DAVIE COUNTY ENGINEERING DEPT. HAS NOT REVIEWED THE STRUCTURAL STABILITY OF ANY RETAINING WALLS ON THE SITE & DOES NOT ASSUME RESPONSIBILITY FOR THEM. 25. THE ENGINEER WILL NOT BE CONTINUOUSLY PRESENT IN THE FIELD. IT IS SPECIFICALLY UNDERSTOOD THAT HE DOES NOT UNDERTAKE NOR ASSUME ANY OBLIGATION FOR SUPERVISION OF CONSTRUCTION, SAFETY MEASURES TAKEN DURING THE COURSE OF CONSTRUCTION, RESPONSIBILITY FOR SCHEDULING THE WORK FOR INSURING COMPLETE COMPLIANCE WITH THE CONTRACT DOCUMENTS AND/OR ALL CODE REQUIREMENTS, RULES & REGULATIONS OF ANY PUBLIC OR PRIVATE AUTHORITY HAVING JURISDICTION OVER THE WHOLE OR ANY PART OF THE WORK. IN ADDITION, THE ENGINEER NEITHER UNDERTAKES, ASSUMES, NOR GUARANTEES THE WORK AND/OR PERFORMANCE OF THE CONTRACTOR. 26. ALL CONSTRUCTION SHALL MEET DAVIE COUNTY & STATE STANDARDS. 27. BEFORE YOU DIG, STOP. CALL THE NC ONE -CALL CENTER AT (800)632-4949. IT'S THE LAW. 28. SIGHT TRIANGLES SHOWN ARE THE MINIMUM REQUIRED. CONSTRUCTION SEQUENCE PHASE 1 (SEE MASS GRADING PLANS - PERMITTED SEPARATELY) PHASE 2 (SEE MASS GRADING PLANS - PERMITTED SEPARATELY) SITE CONSTRUCTION DRAWINGS 1. COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF EROSION CO CONTROL MEASURES AND FINAL VERSION OF STORMWATER MANAGEMENT PONDS. N N *EROSION AND SEDIMENT CONTROL (E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE ANY LAND DISTURBING ACTIVITIES OCCUR. THE COC CAN BE OBTAINED BY FILLING OUT THE ELECTRONIC NOTICE OF INTENT (e-NOI) FORM AT deq.nc.gov/NCGO1. PLEASE NOTE, THE e-NOI FORM MAY ONLY BE FILLED OUT ONCE THE PLNAS HAVE BEEN APPROVED. A COPY OF THE E&SC PERMIT, THE COC, AND A HARD COPY OF THE PLAN MUST BE KEPT ON SITE, PREFERABLY IN A PERMITS BOX, AND ACCESSIBLE DURING INSPECTION. *WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT NCDEQ TO CLOSE OUT THE E&SC PLAN. AFTER DAVIE COUNTY INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL VISIT deq.nc.gov/NCGO1 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (e-NOT). A $100 ANNUAL GENERAL PERMIT FEE WILL BE CHARGED UNTIL THE e-NOT HAS BEEN SUBMITTED. ADDITIONAL NOTES: 1. NO IMPACT TO STREAM, WETLANDS, BUFFER ZONES, NOR FLOOD ZONES AND FLOOD PLAINS IS PROPOSED AS PART OF THIS PROJECT. THEREFORE NO USACE 404 PERMIT / DWR 401 CERTIFICATION WILL BE REQUIRED. 2. THIS SITE IS DESIGNED TO BALANCE. IF ANY BORROW MATERIAL IS BROUGHT ONTO THIS SITE, THE BORROW MATERIAL MUST BE FROM A LEGALLY OPERATED MINE OR OTHER APPROVED SOURCE. ANY SOIL WASTE THAT LEAVES THIS SITE CAN BE TRANSPORTED TO A PERMITTED MINE OR SEPARATELY PERMITTED CONSTRUCTION SITES WITHOUT ADDITIONAL PERMITS UNDER NCGS 74-49(7)(d). DISPOSAL AT ANY OTHER LOCATION WOULD HAVE TO BE INCLUDED AS A PERMIT REVISION FOR THIS APPROVAL. N (D z 1 tii Z O tQ W I= CV m 1- 3 0 ,w0 J CV C2 } r O LU m Co LU ZZC) *# 3LU Z"w oLU0 = V CG CL to 0 C" CV (V � Z4t xs: u.i w r 2 Z Ow J U O7 (_1 Fz � 'S 7 m aQ C ZO­8�O 0 Oa = U Z OL2 0 o, Z CN Z 01 It Q J Ztn� J W o Z ad � U a r- _ Q � Z O LU 3 Z a _ ,0 (1� J \.J W = Z LU N ::) 0 Z)0J U = W i > �e 00 ►J 1 a • LL w O LU 2 N V) w ULU s2 Lf N85-05'06 "W 497.98' Tie AU All S85'05'061E --.li�` 1 "5quore Iron 708 43' o o N -91-a 234.30' V A!$7'20'19"W r3Y#"Rebar 0 140 O Q�o �\ Fbar w/cap J� flb• V ;\? SO QU 01 Structure --1 lTy, o 4G Jam.-il�J -otb�z \ Z 112" Rebar ¢G o� ti m ;3 "t n 1/2" Rebar N M 0) Thar wloop NA083(2011) North 805, 938.21 / East 1,547,638.90 o` a �o b o Z z O � o 00 8�co NIM 'ri Z �b�m o � Q §r I Iry Z Q 0 0 to t. jn Notes: �0 �`A> s. u A, AU � .� AU AU AU ---- AU 159.3318 Acres± Now or Formerly Wachovia Bank, N.A. Deed Book 65, Page 381 PIN 5840855939 Now or Formerly Clyde Seats Deed Book 63, Pogo 49 PIN 5850084822 N 78 Davie County, North Carolina I, Jerry W. Ellis, certify that this map was drawn under my supervision from an actual traditional and a GPS survey made under my supervision (deed description recorded in Deed Book 65, Page 381 and other reference sources as shown); that the boundaries not surveyed are indicated as dashed lines and drawn from information shown; that the ratio of precision � or positional accuracy for the traditional survey as calculated by coordinates is 1/20,000+; the following information was used to perform the GPS survey. (1) Class of survey. A (2) Positional accuracy. 0.10' (3) Type of GPS field procedure. RTK (4) Date of survey. August 15, 2021 (5) Datum: NA083(2011) (6) NCGS VRS/RTN (7) Geoid model: 2018 (8) Combined grid 4factor(s): 0.9999077 (9) Units: US Survey Feet; that the area was calculated by coordinates; and that this map meets the requirements of The Standards of Practice for Land Surveying in North Carolina (21 NCAC 56.1600) and does not meet the requirements of NCGS 47-30 as amended. Witness my original signature, license number and seal this 20th day of i August, A.D., 2021. CAR w J >L .••' '•••. l ��� ofess' al Land Surveyor : O, i L - 4558 = SEAL •a f L-4558 - 4 ?J Z,o0 Su 1232.51 T v 54.64 w w ► Y �► I t °o �o �. Now or Formerly % Steve Wiliam Hungerford Deed PBook 68,7Pog 798 (0 01 C� r ' J r� 2"Iron ' .e r I -�Iilir AP J "$en t Iron 75 51'52 L10 Lr� 7bar w/cop » •_ S85'11 02 E 776.57' Total 718 69' 50.00' I "s$ 228� $;R0� 1140 g 0 �k1. 00 P a J 9�g S9 y `9r0 r9' 5 564.39 Cn' / Now or Formerly 07, Arc dIk1 Ys 00, DeeSao102Pge94668 E I5 440'Rod ! PIN 5850058252 1 ' o -� r-- AL) U 87' ,57„ 1178.68' Axle G AU G -- G Legend 5/8" Rebar Placed O �p Iron Found (As Noted) 1�11;1 Stone Found 1) Encompass Surveying and Engineering, PC located all surface utilities (vertical and horizontal) which were accessible to a survey crew. Underground utilities not discernible by surface appurtenances shown per information obtained from public/private records, utility entities or others and should be considered approximate only. Some underground utilities may not be shown. Encompass Surveying and Engineering, PC, does not guarantee that all utilities are shown on this map, nor do we guarantee that all underground utilities are shown accurately. 2) This property is subject to any easements, agreements, or rights -of - way of record prior to the date of this map which were not apparent at the time of my inspection and might otherwise be disclosed by an attorney's title opinion which as of date shown hereon has not been supplied to Encompass Surveying and Engineering, PC. There may be easements or other matters of record affecting this property not shown hereon. 3) Geodetic Datum acquired via the NCGS VRS/RTN Horizontal Datum: NAD83(2011) 4)AII distances shown are measured horizontal ground distances unless specifically noted otherwise. NAY structures not shown. R/W Monument Found A Boundary Line Unsurveyed Line -- - Adjoining Boundary Line Light Pole > Utility Pole Power Meter Aerial Utility Au Au Water Valve Water Meter '3 Fire Hydran t Gas Val ve D4 Guard Rail Utility Pedestal Slobtop Inlet Fence x - x Sign Mailbox -n- Creek 39.0851 Acres± Now or Formerly Wachovia Bank, N.A. Deed Book 65, Page 381 PIN 5840855939 2 10, 0 7.88' re t ��� 58507'07AE 372.79' %tal /171.94' 1'8ent (rat 200. 85, X PNG, Inc. Easement Deed Book 1071, Page 1113 M �o L25 cow 0 `Ir ti, -• Now or Formerly (�9 7 Steven Don Whitaker L22 Deed Book 828, Page 616 PIN 5850049820 01 01 N f Now or Formerly Helen 1. Jordan, Trustee V Deed Book 814, Page 307 PIN 5850140429 Now or Formerly Dorothy Morklin, *tat v Deed Book 1049, Page 1199 .`1x PIN 5850049292 �o N N r a- N Now or formerly Sharon Smith Cox, Oat Deed Book 1019, Page 912 PIN 5850257667 Location Ma Not to scale Line Table Line Bearing Length L1 S44'54'16"W 23.98' L2 S16'10'11 "W 60.09' L3 S15.47'08"E 69.22' L4 S36'02'19"E 209.86' L5 S63'24'14"E 170.95' L6 S11'16'28"W 121.67' L7 S0852'48"E 108.32' L8 S30'3459"E 57.98' L9 S76'4855"E 114.00' L 10 S89'06'5 7'"E 165. 72" L11 S64'40'37"E 1 89.72' L 12 S36033'35 "E 51.25' L14 N36'44'38'°E 110.76' L 15 N16 36'07"E 47.16' L 16 N 14'25'05 "W 189, 83' L17 N05'18'07"W 152.93' L18 N04 21'07"W 185.91' L 19 N53 25'41 "W 38.73' L20 N1542'06"W 30.07' L21 S36.42'13"W 54.03' L22 S87 2739"W 22.47' L23 N56'51'58"W 106.44' L24 N60'06'49'"W 208.66' L25 N78 45'19"W 81.76' L26 N22'11'24"W 23.20' 198.4169 Acres± Total Boundary Survey Covenant Development Partners, LLC PIN 5840855939 Farmington Township Now or Formerly Davie County, North Carolina Gwendolyn c. Smith August 20, 2021 Deed Book 44, Page 134 PIN 5850352362 Deed Book 65, Page 381 GRAPHIC SCALE 200 0 100 200 400 dOD pp' N,:1.7 ,2 Axle / 28`3 �o "fy 41S79. 5 "E Now or Formerly toy 46' Ire Immanuel Baptist Church Now or Formerly Deed Book 113, Page 314 PIN 5850f 30865 Sharon Smith Cox, etal Deed Book 1019, Page 912 PIN 5650234862 IN FEET 1 inch - 200 ft. Jerry W. Ellis, PLS ENC(f)MPASS Surveying & Engineering, PC Firm # C-4644 6206-B Hacker's Bend Court Winston-Salem, North Carolina 27103 (336) 893-7397 Drawing 21033bound.dwg V Z w w Z C� Z W PE SEAL: to 0 N N W 04 Z � Lyj W U� Z Ow J V O7 V � � 'p) OZ o �O o Oa rY U Z O� ::E 0 o, 0 [N Z U FOR REFERENCE ONLY N W Ind O Q J W Z V �>. J O LU W H � V ad W a�LU z �0:2 O Z = Z W N D in O J O V = > W v 00 � 2 X W W Z 0 > W cc m LU N O o, J W (^ r r w O ,Lmm zZo M 3W V) LU Z�w o LU 4 4 4 / \\\ \\\\+ I--)- " A 0 �53.33`7 0 Ln CM O w M x x r\\ 10' x x I III : 1 I I�,allEl iI� 11 II x � �111''II iilil X X X Ij�111 IIIII 1 ' 1111 II ( I�Ti 11 111'III � lid ----- - I I 6 1111111 30, 1 vB �— I � I — r 15 12) (10) (1 1 `� ®® ��\\\\\ , 3 0 m PARKING REQUIREMENTS PAVEMENT HATCH LEGEND ±297,600-SF (WAREHOUSE w/ 1 0% OFFICE) LIGHT DUTY ASPHALT HEAVY DUTY ASPHALT CONCRETE PAVEMENT REQUIRED PARKING: 1 SPACE PER 300-SF OFFICE, PLUS 1 SPACE PER EACH EMPLOYEE ON THE LARGEST SHIFT, PLUS 1 SPACE PER EACH VEHICLE IN BUSINESS USE � PROPOSED PARKING: PAVEMENT SECTIONS 197 TOTAL SPACES (INCLUDING 6 ADA SPACES) SUPPORTS 10% OFFICE PLUS 97 ADDITIONAL SPACES FOR LIGHT DUTY ASPHALT N HEAVY DUTY ASPHALT HEAVY DUTY CONCRETE EMPLOYEES AND BUSINESS VEHICLES 3 f� 1 a � 1 � SC ASPHALT SURFACE COURSE (S9.5B) IC INTERMEDIATE COURSE (119.0B) BC AGGREGATE BASE COURSE SB COMPACTED SUBBASE NOTES: 1. CONFIRM WITH GEOTECHNICAL ENGINEER FOR PAVEMENT SECTIONS AND SUBGRADE. NOTIFY ENGINEER IN CASE OF CONFLICT. �j 2. PROVIDE CONSTRUCTION JOINTS PER ACI AND/OR GEOTECHNICAL ENGINEER RECOMMENDATIONS c: (CONCRETE PAVEMENT ONLY). a SITE KEYS 1 1'-6" CURB &GUTTER 2 FEATHER CURB AT RIGHT-OF-WAY % a 3 NEW 4-INCH THICK CONCRETE SIDEWALK 4 NEW 4-INCH WHITE PAINTED STRIPING 5 NEW LIGHT DUTY ASPHALT PAVEMENT. SEE PAVEMENT SECTION, THIS SHEET 6 NEW HEAVY DUTY ASPHALT PAVEMENT. SEE PAVEMENT SECTION, THIS SHEET a 7 NEW HEAVY DUTY CONCRETE PAVEMENT. SEE PAVEMENT SECTIONS, THIS SHEET $ NEW DRIVE-IN RAMP. SEE ARCHITECTURAL PLANS FOR DETAILS 9 NEW 10' CONCRETE DOLLY STRIP. SEE PAVEMENT SECTION, THIS SHEET 10 NEW ACCESSIBLE PEDESTRIAN RAMP w/ TRUNCATED DOMES 11 ACCESSIBLE PARKING SIGN 77 12 ACCESSIBLE PARKING SIGN (VAN) 13 4' CONCRETE FLUME 14 25x25 SIGHT TRIANGLE 15 NEW 24" WHITE THERMOPLASTIC STOP BAR 16 NEW STOP SIGN (R1-1) l� NEW DUMPSTER PAD & ENCLOSURE. FINAL LOCATION TO BE COORDINATED WITH z L� 17 ZONING INSPECTOR. SEE ARCHITECTURAL PLANS FOR DETAILS. ` a 18 NEW 10'X10' CONCRETE TRANSFORMER PAD (CONFIRM SIZE PRIOR TO INSTALL) f Nx P vim, Q 639 A4, � J r 960.9 PROPOSED BUILDING 2 960' x 310' 297,600-SF FFE: 727.00 3 C! 3 a w it F � I W I � I I I 12 10 11 12 10 11 I � -- -- I '. G -----. 6- JL .F « Ff- . ...v i.. :. ... .:..., r.. a ... .. .. t.... .t.. «.. ... .: ......u.Y-.. r:i. .t. 'l�r. 3t s'l.„" d : .. r: .. ... ,. .: .r t a t .. r ....., r.. ".<....:r.:. t �.s ...*• ,;:t 't'r r t» "'} r < t . .. , i .a .. ... r" ... .. .. ., .. .. ':.., .. `(•.:- c;t'?:;`� V'f?:';+'r>z ±/:tf f�^ mf%;�.'-:i'✓."'.,. � 98 CAR PARKING SPACES � i vv 4 TYP ��' 18 5 9 '9' �s ° 5 R5' R25' 99 CAR PARKING SPACES 24' T _ 15 14 1 14 / 16 ^✓c M nn A/ (�2 a T� 1� 12"w ,rw 12 2 W ,7°W ,rW ,2 W ,2 W ,2°W , Vd 12° 12 W W ,r 12 � 2 — 6 6 1 15 4 � 'R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W - R R/W-R/W-R/W17T 16 ----------------------------------- -------------------- � I � I 3 \ EXISTING R/W 7 \ o' V z oc w w z (D z Lu to Q W N N � Z� ww rz oW V o) V � � az� OO 00 Oa �U Z �0 0 oa [V z 01 It PE SEAL: N• I SEAL 045345 •'•:�G A N6 0 C� % GGGF 02/21/2023 50 0 50 SCALE: 1 " = 50' N 0 W JI Z O W � H 41� GGCL � V = W Z W a�L — 30C N V = _O C� W = Z W �oLu W u = W W > > 0o O 44 W V) F_ z V Cie Cie M. 0 w N w m Ui CV O � w J w m LL 0 m z z C) w _ v 3w cn w Z�w w02 _ cn V � UTILITY LEGEND 77u EXISTING WATERLINE — -- ----------------------- PROPOSED WATERLINE/FIRE LINE (SIZE) FIRE HYDRANT HOSE PULL PROPOSED FIRE HYDRANT - \ \ / / / ` \ \ \ /_ PROPOSED GATE VALVE PROPOSED WATER METER — -- — ---- PROPOSED PRIVATE LIFT STATION. PROPOSED BACK FLOW PREVENTER SEE SHEET C3.2 PROPOSED FIRE DEPARTMENT CONNECTION EXISTING SANITARY SEWER LINE EXISTING SANITARY SEWER MANHOLE PROPOSED SANITARY SEWER LINE -- ----------- ------------------- PROPOSED SANITARY SEWER EASEMENT --------------- PROPOSED SANITARY SEWER CLEANOUT PROPOSED SANITARY SEWER MANHOLE N 4- 0 P1.1 N a: f 7LLL —COJ ' N o a- ------------------------ — m 0 ------ — — — — — — !21 ---------- w — — — — W_ 1 o" vo— I o" W__ FIRE FIRE FDIC ---SS . . . . SS M Ol \8/ _SS _SS _SS PE SEAL: SSE SSE Y\ 0 .......... 'o SEAL 045345 • - 1b A NE_, 41 02/21/2023 40 0 40 SCALE: 1 40' SS Co — — — — — — — -- — — - 4- — A A 0 ss Co 70" Gv ----------- 7 0 rp PLUG 60 LF OF 70" RJ DIP 0 25 LF OF 6 RJ DIP 6"GV CD A TE FIRE HYDRANT. 70"X8" TEE NEW PRIVATE PAINT TO CITY FIRE DEPT SPECS 'r X 8'r TEE 7 O'PX6'p REDUCER FOR PRIVATE HYDRANT ON PUMP 7 0'r X 8'r 1� -c SS Co SS Co Ss Co s Co SS co ss Co [SS:c�o SS CO NEW PRIVATE FIRE HYDRANT. 918' OF 6" PVC (SDR 26) SAN SEVER 0 1.00% (MIN) SS CO SS_SS__SS_ _SS —SS —Ss SS_SS_SS_ _Ss S Ss _Ss _Ss _Ss _4(_SS __Ss _Ss _Ss _SS _SS — SS_SS__s _Ss _SS__SS_Ss _Ss SS_SS_Ss SS PAINT TO CITY FIRE DEPT SPECS I I � I� t— FOR PRIVATE HYDRANT ON PUMP 1 o" vo— I o" vo— I o" 117�1 01, \A1__ 1 o" V#— 1 o" vo— 101, 1110-- 1 o" \160— 1 o" \A1__ 101. 1 o" \A1_ 1 o" V#— 1 o" \1111— 10., 1 o" \Ao— 1 o" \A1_ 1 o" V#— 101, vo.— 101, 1110-- 101, 11,10— 101, \Ai— 101, A— I o" Ss Co ss RJ DIP 20 LF OF 6' 7 O'p X 8'p TEE Q3 7 0 "X6 " TEE C4 C4 6"GV > 0 > .......... . ... co iL 80 LF OF 8" .............. .. 80 LF OF 8 ,'PVC 80 LF OF 8 PVC iL 0 a: (C900) FIRE (C900) FIRE RISER LEAD (C900) FIRE RISER LEAD R. 80 LF 0 0 U) -In z (C900) FIRE RISER LEAD 0 < F 8" PVC 7 L /V A U) SS Co SS Co < Q)Ii Lu z t- uj COORDINATE wl FIRE SPRINKLER 0 L4 L RISER LOCATIONS (Typ) Cie z GG z PROPOSED 6-INCH SEWER CONNECTION 1E = 777.0.± co < Le) U (REFER TO PLUMBINGS PLANS) PROPOSED 6-INCH SEWER CONNECTION 1E = 777.0+ z (REFER TO PLUMBINGS PLANS) i LuQ he UJ 4 z z Lu V) ED) PROP 250,000 GAL v I vU ON -GRADE WATER LLJ LLI > tn STORAGE TANK (DESIGN BY OTHERS) v < 0 PROP FIRE PUMP -- -------- ( X_x DESIGN BY OTHERS) 1­11k A 11 vI_ 101, 70"X6 "TEE 759 LF OF 8" RJ DIP (TO FDC) ----------------------- -- - - -------------- oc 101. 1 0� ... 101, 7 0 FIRE PUMP DISCHARGE I I I I I �;TO PRESSURIZED YARD PIPING E7 Lu /x I 70"X70" TEE 2 DOMESTIC SERVICE CONNECT/ON x x x 70"GV I j COORDINATE wl PLUMBING PLANS 7 0 " PLUG TEE 6 LF OF 70" RJ D : IP 70X70" to GV 70" PLUG �o 6 LF OF 7 0" RJ DIP 4" FDC STANDPIPE wICHECK VALVE 2"DOMESTIC SERVICE CONNECTION & 5" STORZ CONNECTION COORDINATE wl PLUMBING PLANS 75-LF 2-INCH SCH 40 PVC DOMESTIC WATER LINE PER CITY/ COUNTY FIRE MARSHAL NEW PRI VA TE WATER MAIN SEE SHEET C6. 7 REQUIREMENTS. Iv Iv v VI v I I IVI --------- 75-LF 2-INCH SCH 40 PVC PLUG 7"IRRIGATION SERVICE. DOMESTIC WATER LINE IRRIGATION TO BE DESIGN/BUILD BY 0 THERS NEW 2 "DOMESTIC REDUCED PRESSURE PRINCIPAL ASSEMBLY 7 OX 7 0' TRANSFORMER PAD NEW 2 DOMESTIC REDUCED PRESSURE PRINCIPAL ASSEMBLY _77— INSTALLED ABOVE GROUND WITHIN INSULATED ENCLOSURE PER I (CONFIRM SIZE WITH UTILITY INSTALLED ABOVE GROUND WITHIN INSULATED ENCLOSURE PER DAVIE COUNTY REQUIREMENTS. ENCLOSURE TO INCLUDE PROVIDER PRIOR TO INSTALL DAVIE COUNTY REQUIREMENTS. ENCLOSURE TO INCLUDE DRAIN PORTS) FOR DISCHARGE WATER DRAIN PORT(S) FOR DISCHARGE WATER 2" DOMESTIC METER NEW 7 IRRIGA TION REDUCED PRESSURE PRINCIPAL ASSEMBLY INSTALLED ABOVE GROUND WITHIN INSULA TED ENCLOSURE PER — — — — — — — DAVIE COUNTY REQUIREMENTS. ENCLOSURE TO INCLUDE 71,7= - I V) DRAIN PORT(S) FOR DISCHARGE WATER z sz Lu Oe m/d m/d m/d-_mLL_m/d-m/a 0 ---------------------- 0 u 7­�l AMENI NEW 7 " IRRIGATION METER Cie II NEW PUBLIC WATER MAIN X Lu Lu CL. 0- SEE SHEET C6. 7 NEW 2" DOMESTIC METER Lu Lu V > > Lu Lu Cie Ile IN, 1:,/W—R/W R/W— R R/W R/W R/W R/W —­­—­­'—R/W —R/W — R —R/W —R/W --I4—R/W — W—IR R/W R/W R/W R/W _R ...... R/W —I IR R/W_R R/W ---------- R/W— R R v R/W CV CV 1-1 12 rX2 r' TEE AND 2 VA L VE (SEE SHEET C6. 7) 04 04 50 LF OF 2'r DOMESTIC K-COPPER FROM TEE TO 5'BEYOND BFA — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — o & 7 2'rX2'r TEE AND 2 r' VA L VE (SEE SHEET C6. 7) NEW PUBLIC ROAD uj 50 LF OF 2 "DOMESTIC K-COPPER IR r ci N11 SEE SHEET C6. 0 FROM TEE TO 5'BEYOND BFA N. co 01 0 C4 LL 0 z zzo cv) Lu se V) Lu Lu vv ��Lu cle Lu V) - - $�\ p o to :AX,�:,; 18t0 9t00 20t00 21t��/ 22t00 /2 23t00 _ - 4t00 25+00 �X ' �� W / MM Fm-FliIO -- y0 • O O Now o ormerly --_ i - �T�'��• ••••`, PROPOSED 2.5-INCH PVC FORCEMAIN. \ \ ^ G clyde =,s - ���' I co - SEE SHEET C3.3 FOR PROFILE N �'' Pl . ate; oa 2 \ - - - - - ;�'` ^ ` 1 / Deed Boo< 6 Ya e 19 \ `.`.`.` W A�' 61 NYF' I � - V i I I I O \ o I _ I I O I I _ I II 11 , A A r . LLI . ---. L I _--- - O I I ✓ I \ \ \ 1' + I k- II / 1 I Ii \ O ✓ I I N \ � / I '�' sI � I I I v v I I I I W I v I I O v O I I /li I II �Av�,II� 1 + v o I' M I .. ... ......... M . ♦ I it II IIII .r. -'�' / III II / c II I I / � - - - - I I �I II �I I I II I II I 11 ♦ ♦.a to I I I ,III III II I ': ': . III � I it .\. ti ♦ ♦ , I I I III '.'- m I" i I \ O I III li I I I r I I I O I I I # I I ;.1, 159.3318 Acres a I al � ll I I I I I O Ili i \ I I I- - O I \ I I I i i t I II I I I i �1 Now or Formed \ I I r Y' i I I I' W 1 I I I . I I I I •7 I 11 1 I N�achovia Ban N.A. �1 I k I I ! I 1 I I N � I I I ', I -III M I �`PageI I I ti If l � I .� "Deed Book 65 381 I I �III I I I I I I I I �I I I I PIN 5840855939 I I •!' I I I I I I i II I I I � � II III 1 I I IIIII � ,% �� i j I � I I I I,I I • �. v •v. 1 I I b - I„I I I I`. III I I -� ` \ I I _ I 11 III ..... .. . I-'I-.L. �:-. - iI I I IIII I 11 Ij I III III IIII II `��. 1 i' IYiI / / / G 1 IIII \ � I � I III II '.I' J I I I I v ate �I I k' ,II I I I v I I _ I III lI I I � T r �'- I � I 1 I r I � 1 i i / 1 I N i I Ir I � I � I I 1 O/ - r O o / I I / 1 l\ I O I \\ , I \ r G - I I - �1 I I / 1 v I / V \ / Ir IIII 1 I / I I I I T I l i2 z o O I � I I Z o I i I I i 0 O i i d X I I I `O I 1 + - - /T l /, l�l WE 703.5 -=vi' / \ to _ / I - ,� i II / I / I - I I � I 1 / I l i- 1 I • f - 1 - il i _ 1 - L I I i40+90-v +00 v v�///l/// �O�r,_� - - -• v _ - ; - - ✓ ti LIFT STATIONS I s GRAT E69050 - \ -_ O1 W T �O L I � + Run ]2101'� ¢ N 710.21 •�\\ _ O Volt 710.97 \ I g V� S n i== \ \ I � I � � � - �, � INV IN:683.00 6 PVC �I I A r i I - -_ Ir I _ �690.9I - I r - WE ti I CONNECTION 2.5-INCH FM ' v w/ INSIDE DROP PER DETAIL 6.05 A r a• X Q SSMH-2 (PROPOSED) GRATE:734.00 I INV OUT:710.61 8" DIPv v �I v I�I�I I 9miw.uannn \ \ - y°`.a� CIV, 7 l94�O • �i10jtl II \ \ _ \ I III I. s08 22J2[- .r � ,..: >u,•- � X \ - - - - _ � I �' � 11 I III ! • f , o T 935' \ I .. a \ o R1,7409•E � 8„ DIP (401 PROTECTION) ® 0.50.6 404.37 LF - 10' RaE. \ \ . SSMH-11 (EXISTING) w s� GRATE:725.88 Ole INV IN:708.60 8 DIP _ M / I S . 4 I I I v I v \ / I I III / .I •• ,- . _ II I I / i I wv I 3 I I // ✓ �� / , / m / , m f:2rCM:I: U,I:Ly :I DISCHARGE 1-1/4"NPTVertical, Bolt -on Flange LIQUID 160°F Intermittent TEMPERATURE VOLUTE Cast Iron, Class 30 MOTOR HOUSING Cast Iron, Class 30 SEAL PLATE Cast Iron, Class 30 IMPELLER 12 Va ne, Vo rtex, Bronze SHREDDING RING Stainless Steel CUTTER Stainless Steel SHAFT Stainless Steel SQUARE RINGS Buna-N HARDWARE Stainless Steel PAINT Powder Coated - Industrial Grade Tandem Double Mechanical, SEAL Carbon/Ceram icBuna-N UPPER BEARING Single row, Bail, Oil Lubricated INTERMEDIATE Single row, Ball, Oil Lubricated BEARING LOWER BEARING Sleeve, Oil Lubricated PFG Series: 20 ft. Custom Molded, Fast POWER CORD Disconnect, for Sealing and Strain Relief. CSA approved, 12/4Type SOW Oil Filled, Squirrel Cage Induction, MOTOR Class B Insulation Capacitor Start/Capacitor Run. Includes overload protection in the motor. Requires SINGLE PHASE starter or control panel which includes capacitors. THREE PHASE Dual Voltage 230/460. NOTE: Consult factory before making modifications as they may effect CSA listing. Description Designed to reduce domestic, commercial, institutional and light industrial sewage to a finely ground slurry. Submersible Grinder Pumps PFG - HH & HV 2HP Submersible Grinder Pumps Series: PFG2002HV & HH PFG2022HV & HH PFG2062HV & HH PFG2032HV & HH PFG2042HV & HH 2 HP 3450 RPM - 60 Hz Submersible Grinder Pump c C"Ous F` WER-FLO Power -Flo Pumps & Systems • 877-24PUMPS • www.powernopumps.com Pumps & Systems 3 BACK TO INDEX e EL HP Hz Volts/Ph RPM Full Load Amps Locked RotorAmps NEMA Start Code Cord Type or Size Cor D. High Volume PFG2002HV* 2 200/1 3450 17.0 53.0 F 12/4 .67 PFG2022HV* 2 60 23 3450 15.0 53.8 SOW 12/4 .67 PFG2062HV 2 60 200/3 11.0 42.0 J SOW 1214 .67 PFG2032HV 2 60 230/3 3450 6.0 J SOW 12/4 .67 PFG2042HV 2 1 60 1 460/3 3450 18.0 1 J 1 SOW 1 12/4 1 .67 High Head PFG2002HH* 2 60 200 3450 17.0 53.0 F SOW 12/4 .67 PFG2022HH* 2 6 230/1 3450 15.0 53.8 H SOW 12/4 .67 PFG2062HH 60 200/3 3450 11.0 42.0 J S 12/4 .67 PFG20 2 60 230/3 3450 9.0 36.0 J SOW .67 G2042HH 2 60 460/3 1 3450 4.0 18.0 J SOW 12/4 (*j IMPORTANT! - These pumps require a control panel with start, run capacitors and relay. Capacitor kits which include Start & Run capacitors and Start relay, are available if a Power -Flo control panel is not used. See page 13 for wiring schematic. PF88243 - for 200 volt, 1 phase PF73306 - for 230 volt, 1 phase MODEL ITHPVIts/Ph BREAKER SIZE I HEATER SIZE (**} I VOLTAGE I START RELAY CAPACITOR RUN CAPACITOR High Volume PFG2002HV 2 200/1 30 Amp K-60 MARS 169 150 mfd - 250 volts 20 mfd - 450 volts PFG2022HV 2 230/1 30 Amp K-57 MARS 169 150 mfd - 250 volts 45 mfd - 450 volts PFG2062HV 2 200/3 20 Amp K-53 N/R N/R N/R PFG2032HV 2 230/3 20 Amp K-50 N/R N/R N/R PFG2042HV 2 460/3 15 Amp K-33 N/R N/R N/R High Head PFG2002HH 2 1 200/1 30 Amp K-60 MARS 169 150 mfd - 250 volts 20 mfd - 450 volts PFG2022H H 2 230/1 30 Amp K-57 MARS 169 150 mfd - 250 volts 43 mfd - 450 volts PFG2062HH 2 200/3 20 Amp K-53 N/R N/R N/R PFG2032HH 2 230/3 20 Amp K-50 N/R N/R N/R PFG2042HH 2 460/3 1SAmp K-33 N/R N/R N/R Winding resistance ± 5% at terminal block. Rated operation at ± 10% voltage at motor. (*} Recommended heater sizes may very depending on pump station requirements. POWER-FLO Pumps & Systems Power -Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com 4 BACK TO INDEX PFG-HV 2HP Submersible Grinder Pumps 110 5.00" 10 4.75" 90 4.50" 80 T 0 T 7D A 4.00" L H E 60 3.75" A D 50 I N 3.25" 40 3.00" F E E T 30 za 1 D-j 0 O MODELS: PFG2002HV PFG2D32HV PFGPC2002HV STD. IMP. DIA. 5.13' SPEED RPM: 3450 HP: 2 DISCH. SIZE: 1.25" ISSUE DATE:: 4109 CURVE NO. a PFG2022HV PFG2042HV PFGPC2022HV 5.13" HERTZ: 60 SP. GR. PFG2HV curve PFG2062HV PFG2052HV 5.13" 1.0 - f4_ / WIt74 V ,� 1. I ftL .. . . P WER-FLO Pumps & Systems 6 10 OPERATING POINT 26 GPM @ 81 TDH 20 30 40 50 US GALLONS PER MINUTE Power -Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com BACK TO INDEX PFG - HH & HV 2HP Submersible Grinder Pumps G L4 L2 L3 Z p 2 y � 3 i G 1 2 1 3 TERMINAL BLOCK G t 2 3 x Y 0 1 m G T1 T2 T3 Figure 7 - 2001230Volt, 1Phase R G L1 L2 L3 Y L7 K G 1 2 3 TERMINAL BLOCK G I 1 1 2 1 3 '•• MOTOR LEADS Figure 7 - 460 V01tr 3Phase Power -Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com G L7 L2 L3 . "m G I ! 1 2 3 TERMINAL BLOCK G 1 2 3 Z c� BACK TO INDEX MOTOR LEADS Figure 7 - 200/240 Volt, 3Phase 1 Phase Capacitor & Relay Pack For Control Panels: 2HP, 200 V, 1 Ph - PIN: PF88243 2HP, 230 V, 1 PH - PIN: PF73306 F' WER-FLO Pumps & Systems 13 UTILITY LEGEND EXISTING WATERLINE PROPOSED WATERLINE/FIRE LINE (SIZE) FIRE HYDRANT HOSE PULL PROPOSED FIRE HYDRANT PROPOSED GATE VALVE PROPOSED WATER METER PROPOSED BACK FLOW PREVENTER PROPOSED FIRE DEPARTMENT CONNECTION EXISTING SANITARY SEWER LINE EXISTING SANITARY SEWER MANHOLE PROPOSED SANITARY SEWER LINE PROPOSED SANITARY SEWER EASEMENT PROPOSED SANITARY SEWER CLEANOUT PROPOSED SANITARY SEWER MANHOLE 30" X 36" SINGLE LEAF ALUMINUM HATCH W/ SS HINGES do SLAMLOCK (300 PSF) r I r HATCHWAY SAFETY NET DUPLEX CONTROL PANEL W/ HIGH LEVEL ALARM BEACON �NEi19FF- ROY ELECTRICAL CABLE ACONDUIT J 3' ELEC. CPLG. CONTROL CABLE BRACKET 7'-6" PRECAST CONCRETE NET WELL BASIN MANUFACTURED BY PARK EQUIPMENT 888-611-PARK OR EOUAL -MODEL wW%X r 6" INLET PIPE 13' 6" INV EL " 683.00 PVC INTERIOR LINER FLOAT SWITCH (TYP) 681.00 HIGH WATER "ALARM" LEVEL 680.0 LAG ruMP ON LEVEL 679.0 60" LEAD PUMP ON LEVEL ------ ------- 48" 678.0 36" PUMPS 24" BTM BL . 676.0 ---w----w o" w 10" Vd FIRE FIRE 0 FDC ---ss ----ss O ss ss ss Q • �,111 1 A ' I Ir 1�1 .- SUBMERSIBLE 0 4' CALV VENT W/ SCREEN - 8' 48" 72" BASE SLAB DIA.- *NOTE: THIS DETAIL IS PROVIDED FOR DIMENSIONAL REQUIREMENTS ONLY. PRODUCT SPECIFIC DETAILS MAY VARY FROM WHAT IS DEPICTED. NOTE TO CONTRACTORS EL 690.50 42" RESILIENT RUBBER PIPE CONNECTION *PRESS -SEAL TYP. �RRST JOINT 15 ABOVE INLET ELEVATION dIIS MADE WATER -TIGHT W PLASTIC FLEXMLE GASKET. RAM -NIX) X' PVC BALL VALVE W/ UNION X" PVC BALL CHECK VALVE X• DISC1ARGE PIPE SCH 8D PVC LIFT -OUT CHAIN, 1/4' STAINLESS STEEL STAINLESS STEEL GUIDE RAILS 2" DISCHARGE ELBOW BOTTOM POURED MONOLITHIC W/ FIRST SECTION OF RISER FILLET BY OTHERS 1. LIFT STATION SHALL BE A DUPLEX SUBMERSIBLE GRINDER PUMP SYSTEM. 2. EACH PUMP SHALL BE CAPABLE OF PUMPING 26 GPM AT 81 FEET OF TOTAL DYNAMIC HEAD. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL COMPONENTS NECESSARY INCLUDING POWER, ALARM PANEL, FLOATS, VALVES, ETC. 4. CONTRACTOR SHALL PROVIDE START-UP AND PRESSURE TESTING OF SYSTEM. 5. WET WELL SHALL BE VENTED WITH A SCREEN 6. LIFT STATION SHALL BE EQUIPPED WITH A QUICK CONNECT GENERATOR RECEPTACLE. GENERATOR SHALL BE AVAILABLE ON SITE (PROVIDED BY OWNER) PFG - HH & HV 2HP Submersible Grinder Pumps L1 L2 CB d 1 2001240 VOLT, 1 PHASE 60HZ WITH CAPACITORS IN PANEL -------- POWER-FLO Pumps & Systems 14 L1 L2 L3 CB 200-2401480 VOLT !!!! !!!! 3 PHASE, 60H7 M OILSG T T1 T2 T3� Z v LU Ld x s DL � � Power -Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com BACK TO INDEX V Z w w Z (D 0 Z w to O N N W � N � Z � LL w KZ O w � � V � V � � LL 'CA a _Z OLU -he J O De 0 V o L2 0, 0 [V Ch It PE SEAL: ,�rrraaa♦ \-\• CARO I SLAL 045345 '••��c 1 N6- •' ���: 02/21/2023 100 0 100 SCALE: 1 " = 100' N In 1 Q J LLJ Zvi J W O I- GG � U >- 1-- W aoW Va =Z0 J _ W Z W �0J U = w > W a� 0 O cC W N Z Iz w ae 03 V U V O° Cie Z) I- d Cie Q' w w � d N L > > w w Cie fl� 00'^ N N D III V W m • 0 m ZZLU L.I..I 2 3Se w LU Z�wLU w02 o V) V � LZ Q I�n1 to (D O N N � I o n a0 N Z Z xx OM �to /� H O •` A A O Z J W \ Q ~ w m =Ole � Qf -0 50 °000 1+00 2+00 3+00 Z) 4 i " ? 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 `L V °? y�22 Z QZ c9^� 2 Op ■ O J o — Anc WQ^ Z OD O 74 z �' h a Z EXISTING GRADE ; a w M Z ol PROPOSED GRADE - 73 FM PE SEAL: C A FMB •.......... O II - _ FM FM FM FM FM FM FM FM FM FM FM FM F FM � . , CORE EXISTING MANHOLE _ _ SEAL 045345 72 ao AND CONNECT wl RUBBER CONSTRUCT INSIDE DROP FORCEMAIN PROPOSE 2.5-INCH PVC FORCEMAIN ' •• v BOOT AND NON -SHRINK GROUT CONNECTION PER CETAIL 6.05 : �G� ''•: GAN6 •• ��� BUG 8" DIP (401 PROTECTION) 0 0.50M 02/21/2023 71 7 LF : 404. PROFILE SCALES VERT. SCALE: 1 " = 10' 70 HOR. SCALE: 1 " = 50' ■ 69 ■ 68 67 -0+50 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 0 18+00 c*q 17+00 18+00 19+00 20 00 21 00 22 00 23 00 24 00 25 00 26 00 27 00 28 00 29 00 30+00 31+00 32+00 33+00 34+00 35+00 • • w J Q ' V PROPOSED GRADE Q EXISTING GRADE FM----I--FM FM —FM FM —FM FM —FM FMB —- FM FMB M FM- �F ___-�-FM--FM— M FM—FM FM —FM FM —FM FM _ —M—FM Z N �FM W LLM : PROPOSED 2.5-IN H PVC FORCEMAIN : Z "1 Lu O • �— FM�F J W z 00 < a ■ ■ z W W W a ■ Z a = O W ■ ■ W ■ �/ I = Z W � • • W V Lu a W . < o 0 ■ �z Lu aZ■ _■ _ ■ V' ■ Q• • 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 kn W 34+00 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 45+50 ■ 740 730 EXISTING GRADE ■ ■ PROPOSED GRADE Z 720 FM�F FM M OVA Q. h io too 0 710 FM _ co FM FM FM FM— M FM FM p ■ Z lz C9 2 cn ■ • V 2 w ' PROPOSED 2.5-INCH PVC FORCEMAIN \ 700 0 3 ■ V V -, ■ ■ V m Cie ■ \ L Ine � a F,y 90 0 0 ■ Lnv) ■ FIN w w Cie Qe ■ ■ CV CV N N LU■ ■ N\\ Z -0 CV 80 O \ \ J ■ t/'f p V' W ■ ix CV Q5 ' ■ ■ 70 34+00 ■ 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 45+50 3 � mLcl - J LL- w m m w 0 zZo � =M 3w w Z�w o w= o= V V � I I� � I J �,I' � I I \"" �0-- 11 / 11 \1, 1 "I, \ 1, " 11 I'll I 1\11 I , "I 11\1 11, "1', 1\1 \1 11 " I'll I "I 1a1 --03P7\ "I 1, "I , \1 \ \11, "I 1, v GRADING LEGEN \` JNG CONTOUR o \ / �j � A / - - - \ir / / 3 PROPOSED CONTOUR \\ - S / m V a0 -- , - i C %; / I - '���� r' �v - ' " dp / 1 PROPOSED LIMITS OF CONSTRUCTION \; \ / 680 - vv� v PROPOSED STORM DRAINAGE EASEMENT �: 0�1 �\/ \ - 3 PROPOSED STORM DRAINAGE PIPE -v v v v v - /_ �_- _v 0 --------z:�-�------�-- f� � �,- --------1� 1'1_511\\11\, N\\ -\\,1\N1/ \ - " \ N k -,. '_' I I I I/\ - I.11 ,.�1-11II I I- � _, I_I 1I- , ( ' I' I ��' \ '/ , III I I \ I � � \ \-1 -\ _ _v � v v' v v -- - - / v v v PROPOSED SPOT ELEVATION (GUTTER LINE ELEV) V �-I/ \ J - _� - / A ` 77 v v � -� I v "I I v `� v v �y69S 6�3� / / PROPOSED JUNCTION BOX v - - 9� - I b - v - -_ �� O - 3 PROPOSED CATCH BASIN \ ` - - � � \ \ \ �� I PROPOSED DROP INLET ` V \ V - - - _ _ - � / N / "_ 8 � . v / j - v / v - - - - - _ - - - - ' � I PROPOSED FLARED END SECTION 685 --- vv �6 `r � vv v` -- -v ----------- v - 8`s�%� .) ' � - _ - _ - v v zJ 3 PROPOSED OUTLET STRUCTURE 68S � .) -) - --- ----- I - �� -- - r /� _- -- - --- -- ---- / - -- -- - \ 680 _i 6> "� - - - v I PROPOSED HEADWALL 680 - 8 V -v ----- I -- 11 685 � �I',, 11 \-3- PROPOSED RIPRAP APRON 6 \ -) �' v 90 _ --- 692 V �I \ \ v vv i_* -_-- --- \ � _� � 0) \_� 4 �" \ \ \ I I \1 \" I I \ ---_ I - - _ _ - / / v J 9 9 \ i- -_ -- - --- -- / � . 3 9 9 ,\ \ A v- -693 - - -- -�� ,�-4 ` v v v .) � v v v -- ---- �� /'I W " / ` v _* / _ �_ "v ` / _ N - --- --- v-v - / / - v I - // 11� � � � \ \ � ,\ \ ` / -- / - r / - -- _' \\ \ \ \ G / -v A / �- --v \. / A * -- v A \ V -_ 1-1 A �� -- \ \ / \ h - --- 696 \ \ \\ � � ------ v 694 / / , / // - v � C1 - / � / / _--� v -v v v v � / , // --- 700 v- � v -� v I i --- v / __ �� v. - - - / �705 - - v /' \ \ \ a V% \ A / \ V /-v �� / / / v v �v I �� / / ` -_ -� v / v a _i i/ �� \� LL G :v cs _--- --- v 695 -- /� ii y - - - v a v v V -- .. �1 I- - - � / v- -_ ,� ,/ - - -� - �00 / - - �� v� I / v -v v i -�- - - v v - \ t v _ � I I -- - ��T I �I "I .1 _* \ -- -- `\ ---- V / - - �II vv _* / �� - - - � - - d O2 v - v _- v--- �� �\\� - -- _ - - - --- - \ / \ ---- 698 697 696 y - / I i - - - 1," /� \ ��� - - - \ / - - - - --- v i� - - "�"�� - '\ 'I \\\V� , A � \ � - - / I I I - ���VO �� ,�� / I - cy v I a, %� I'II I III - vvv�S y v _----- - e , _ -�-/ I ��;, I I/- vyvv v - v -- - ---I I I ;;'I '_ II vv� OS -- -v -, \ - -- �1 �i ` i ,/ /___ v IIII �yyvv� '�___ v - I � Ir � / l' �-- v v �, - - ' � I 1 � ` 1 / �� ., - - v - � _-v � _ // - v - �rl�o 1 - ��� / ��� �� " _ A -- r' V 703 /i - ` - - Q' y � - I �� - - - -� �i' / AV �'�� �A v - I ?, o - - v / - �' I '.�� v., - - v - --- -- - -I� I �, / �;; I v v j ��\V� v -- \ 3 ----- - - - - - i --699- - v - 10 ��� �" ice/ r,. �� v�� �� - - - v v / - _ - - I v I _ / / - v - - - ' 4� J p'I I Ir J'� I �?I '� - - - - - -� '��/ �1 _ O CIO i ---- o - 7 / - /- -- v - � ��/ ' - - �� , -70 �� �ti\� / _ \-V ---_- I I \\_ : \, � I � \ v ,�I ;,� I I I°re­v � v I I I fES 2 -_ FES-1 - I � / v - `a , � I I I -- ----- '/ �� I I 1+ i INV IN: 702.00 30" RCP -- ��- - �" �, - -- ��.... pP - �I i' -� - - - - - _ _ - lNV lNN_ 702.00 36" RCP - - �� - - - ��----- T- - �� �j CB1.2 CB Z.1.1 I - - ,_ - / v/ �I --- -_- /- - 701.5-- - --- - - ` RIM CRATE: 718.96 v� �� �� - v A \ / IN IN: 709.42 24 " RCP v - � , I RIMIGRA 719.32 � � / � � _702 - 0 702 702 -_ I � \ --- - � :� INV OUT: 715.07 24" RCP „I 705 �� 70S 705 - - --- 70S - - / 39 - - - - v v - - INV OUT: 708.42 36 " RCP b 10 - _ - - v - - - I I ' � ;- . - � h �` ✓i �,/ - 770 �-3 770 770 -770 ��� - � v - - 59 ,� / - - - - - - - - v i � �� 77S � � 77S 71S 715 �` - ;; / 0 ��,� ,i - - 719 719 - ---- 719 _ v . I o 700- --- ��r ° -_0 144.0 LF / - -v 144.00 LF - - - - - I I � h ' f I I I ,I 4 „ RCP ® 0. 50/ / 24 " RCP @ 0. 50/ --- -- --- �� 'V '�.) � i� i ' I `� - \ i I 1 LF 50 00 LF 6 RCP @ 1.00% I I ___ + b - --_ �� //� ` �I � �� II I CB2.1 7I �2 ��I /t'� �c��� Q - v - - v / I v . , � I I . ti ... RlMIGRATE: 719.32 CB-2.2 CB 1.1.1 �..:CB 7 �I "O � �� � A '. RIMIGRA TE: 719.32 3, v ' I ...... ��.;:.♦:�. ��.:.: ......: h �.. ..... : . O r: .. �.....:. ... ,•...... lNV lN. 714.35 24 RCP � • :..... .... .. � . � �..:: <::.:. .� •......... :. .. �® v a o o ... RIM�GRA TE. 719.32 RlIN�GRA TE. 719.32 ... �. . - I � � � �, � � � � �.� I h , ...: ....... ..... � ,. > .... .. . ..... INV IN: 706.98 36" RCP � `' ' � �v , t - v � - - - - - \ i I r" o INV IN: 714.35 24 " RCP lNV OUT: 715.07 24 " RCP lNV OUT: 715.07 24 " RCP . t v - v - v A "I � � e.) � � � I I � � � I � I N' I �� INV OUT: 702.30 30 RCP INV IN: 714.35 24" RCP 8 33���9 v � - \ - � / � 699�I 7 .> ,. I I l �.� I lNV OUT: 702.30 36" RCP 2�„ MCP zF I � v 721 ° --------------- 76- v/ -/1 v 00 v . �I j CB 1.3 JB-1.4 �1 I �� �1 a / / - 0> r+ RIMIGRA 725.25 v- /i � A / III, -v -- -� // - �� 1' ��� / - - ss ss RlM/GRATE: 721.50 ss - - - - - - v v ,' ! : '01 v - - _ _ - _ / I INV IN: 710. 68 24 " RCP INV IN: 713. 45 24 " RCP I - � v - - - - INV OUT: 713.35 24" RCP ; `� - ` --- ----- - - l INV our: 710.58 24" RCP v - I / I _ - h � � \ o 72 22 2 7 I 7 2 r 7 I r T' - - - .... ........ . t .. . - , .. .,..... . ! �i %_.. \ I \ . ... •• it • Y � •• •. . •! • i , .. Y ':jam'.'`. �: ir ti r: 23 23 x \ ..... •. .... ... .. • .. .. t .. .. . v .. ... .. ... . e - . .. r � I t L �'� �i> 24 24 Y "'1f -- .. ...... . / i t" wF t • . . . . n r 702 / - i ✓ . . O. .. ::.t'. l 2S . t Y . � 4 '' 2S 7 ` v . Y. h Iy S r r / :. .. ... ..,• :... ... •. . a. r..� r. %J.:. / v do w •v. .. fir", �'�:? ��:. �: / / 7 Y 7 � ..*�.'/*.­ A" t. L. / \ ya i i v v.: I 'v•• I , Y. . 7 4 ♦ s ; , r � Ii / I • 71S - '1 � _ / I ,- , / // I I / I i -51 \� � 'II of o // _- - - i T � � - - - - _ \ / - CB- (OPEN THROAT) v � I I _>0 � � / - RIMIGRA TE: 724.00 I / / INV OUT: 715.77 24" RCP 11 � LLJ \ - - v- ��,' v 11 v ��� .) v �� - --- / / / /- /v � ->0 1 ! �\ 1\ , \�' -i )I tE I I / / // � -i 3 _ - -- a - . - / � I ��. - - B --- _ � 724 1 B /; - /' �' / `�v O v v vv �� ` v /� �� O - / j A - 8v �� \ \ \ v�� .) v v v'\ // / (� /�� I� I� V � �T1 v� \� / / / va �� � V I I A -v a / / / - - - - -I-- D�It -v--� A �'I IIII A � A � _> a .> .> �- -- 11 4 � - - + ON _ - ' 1 v i \ �a N C \ h �- -vv A' I v - '�I I I - % h, >> -/�� III �� �� VA r�� � ---I- - - - -�- vv y� v I, II III II, ,� I��I,_ -�� 709 j I I I !���K /--- �� / I � � o v , - X _ �I I I I vll, ,, , M >>_s - / -- _�- . I - - "'� - 7 b _ -- � II , -- -/ _ I ,�1kI 'j�I -�, I �,vo �� 720 I � / / �� i / / - , � i � �� _ �- r / / -> .> 3. .>/ '� a .) a .) , � - 9 � � .)_ '� .) I I dol , , i i 'r ) i i i '1 'r +- 4 i j ->- -." -j .) .) 4 i j j j �- i 'r /.) � _� > .) .) ___� - -, �- / / , .) l4 i i i-� 3 i i .) + -i i i 9 9 3 i i -) 9 i 9 9 9 i/ / i\ 9\ 11 -3 .> .) .) .> 31 * .> . / / / '-_ ` .> y z a by//� i .) .) i i i i .) .) a a i �. i i a i a �,.. 9 9 i i 9 9 4 9 9 9 9 9 i 9 9 i i __jiz �\ //// �O- "/// \\\�\, 100 - 100 \` � - - - / / \ ", ----- � I' /-- �, . . or L725 - � C'w / II / x x \ 1 1 - / / / !' \� I � / \ �� ��� I A� -_ / � V I �4� I Il������ ��� I I ��Z r I N III ����770.5" v x x 11 I ,_s- . . - s, --'"' / I I - I - i,� to" � I �z �O 3 v i' /II II vv III I ` ---' N '�\I � I a f �� v h I � I �.� 1 ' IIIIII �LII ��h �� i - / \ - 3 I I �, x hI III II I.� .,� oo ,\ I `v X X. I� I I o I II - III I - � v I \ r�C 1(I \ v v I I '` _ --- I C I cr e Q � I,'\ (� llI � I I I . ' --- - --- �� +� ��, a, v fi '>> III v II 726 i of v (n v I I 1 _ U v I I I I v � CB 3.2 � 11 � I CB 3.3 v 1 1 I � ��� a v �� I v i i, ii' II II v I I Rl� GRATE: 721.59 � � � / � � � � ; I I I I I I h , h I / � Rl�r/cRA TE: 721. s9 � � ``' , � Q 0 0 op Jv / ! I I I v v\ 1 1 1 1 N I I CB-4.7 (OPEN THROAT) IN IN: 714.24 36" RCP op W_ � ca - v _ I B ) i �.11 vv v III11 I RIM GRATE: 718.25 INV IN: 714.74 30" RCP INV IN: 717.25 18" RCP I I ', \ INV IN: 716.25 30" RCP O � Jc `I �v \ V� - �j �II�I�vv \v �� I 1 ! F � � �� I Iv lNV OUT: 713.96 24" RCP lNV OUT: 713.74 42" RCP ------- ---- --- r � � 0 „� Ig I 1 1 I lNV OUT: 715.75 36" RCP - - - - v0 O ` �� I FES-4 1 ;� I 727 _ G� I I aj � v - - - - ------+;� I Lc)Z I 4� : ,.-:......, . ..:..... . Q � � .<. .. .t :. ..r. ., . tF N , :... .. .".. :Y� >Y"-a �;w -Y. .a.... •. r?S: u.. •,. ::f. T.Y^ I ,.. .. ....: . < .. : ..F. , ... .:.. .• f 5 .. : . ... :.j'�2%.';�...��'d'?: .�ia.::y;". .. r:,.+.:?a:" � I INV IN: 710.00 24 RCP ". , : <. , . , .. ... _ . .. . • • ..... .�• ,: s::'�.. , . : s . Y.. .. .,. s : .. "e.. . R , : .K a ♦ .i'.' .t_ ''y"'•.i :`i:t'.;. iikl �,: � - I .. .. .. .1 ..< .> _J:_.":. <. .. .: <.i s .. ..,. ! i.. <.._� .... _T. 2 ;.� .5.: t','1. ":i �•i":.. "::X:a'.'.."ts','t : .. .. . :... ..4 1. ,rF .c .. :. , x r..: .. ...r .: .i. ., .. 1. .. i i ... t.. . < .. .. ss ... .. ., 1:i _:�'H3 ., a:k... .`.1�v �:::: �i fit:'+,'li: �'; SJI:'. I � ' �fS:. ^.f... O I 1 h� I I I Wv II O I \ 0, , \ �VA \ y. I 1 726 726 726 726 726 726 0 � / I a V� l l b I tff` - I � � V A A A I VAN VAN / - VAN - - - - �' 3 \ \ \ ��\ I to _ _ - 9 9 A A \ j`� fES_3 � w / // ---- _-- v v w 11 -v II � \�, vv V/ / ��j ��, lNV IN: 711.32 48" RCP 1 I�� �s / / v----- 727 �� v ' ` � \ ,p \ \ j 1� \ \ \ V \ \ \ i c { 12� tj"kI �15 / I / C r� - i ¢:. - -n� I �25 �2 / / I � lil± [ / I / /2 �6� - i I � Idi I � I _ I a-, v / \ �� ���� ,t,,.- %-� � .> '___ �•.-> --->-)�� v Iv v .- - 2 v I � �\ v v I �� , iA' ` 724 725-I 724 723 - 724 - - -� p \ � -- � \ 2 ° --- --------- - ------ ----- - - --- - -- -� - -- 723 -- -' - ----- - --- �--------- �3 7 722- - 2 $ � -_-4 ..) /') �����vv�� �� _ 7 v v 720 721 , 722 --- v �2v "4 -) ` ` _� > 779 720 727 / / 723 - , a .) � \i �_\ .) � +� \ J2s - 2.i ?! Mob M�1! M/8 b Mid/ Mob -_ ` \ T 3.7 LF 722.. 722 03.00 LF ,z„ ,2" , �,z Y-199,63 LF� -713 l � l i _____ I.. " (", \ 726 ".� 1 , z 1�, , 2„ , - F � �; �_7� _�41 � , 9\ \\ \\ \727 \ " iv 724 723 724 723- A RN`' 72.5 R/W RAW R W 72S R/VJ R�/d / / - v - - � % � 726. / - 726 _� /' - �_ - sl `� ��-- --727 ---- 48" RCP @ 0.50% ---- ----- ----- 727 ---- --- '---- ---- - - - - �� - v 728 49.66 LF v 728 - - / / v / 30 " RCP @ 6.86/ CB-3.1.1 RIMIGRA TE: 721.27 RIM/GRATE: 721.59 30.00 LF - - RIA41GRA TE: 721, 27K \ � \ � IN IN: 712.07 42 " RCP INV OUT: 716.80 30" RCP ' - � - - - v INV OUT: 716.48 30" RCP ,�,,, ,A,, 7, d Q / / \ \ \ 1-1 „mr „m. , , .�,�, 30" RCP / / \ \ 729 / v - v 729 / v INV OUT: 711.57 48" RCP 729 - - --� , �v � vv � vv /_vv� /--- 30" RCP @ 8.00% �- \ \ - - / 30.00 LF - / - - / - - - - -730 � v v ,, 730 ` v ��� _ v \ - _ / - / \ / --- 737 `v // 737 - �� / i - CB-3.3.1 RIMIGRA TE: 721.59 INV OUT: 716.80 50" RCP 730 -73 724 728 I I CB-3.4.7 RIMIGRA TE: 724.65 INV OUT: 720.94 18" RCP I 30 " RCP @ 1.83% / 30.00 LF W J V J W j V Ce w a b 72� a a M/�- z�,," _28-z„ ,z„ i s � i -R 726 R/ jV/W R/`�6/' R/R W RA 11 �' o - - - - - - - - - - - -7 CB-3.4 RIM/GRA TE: 724.65 ,\10 INV IN: 720.34 18" RCP /0 LF/ - - - � Z 1 � r N N N � Z� u.i w K� O w 6, � V = aJ'7 V � � a Q a� QZ� OJ O °c aQ N Uan PE SEAL: I SEAL � ®45345 02/21/2023 50 0 50 SCALE: I" = 50'0 ;> �e :E ; 44 (D ca IIIIIIIIIIIIIIIIIIIIIIIIIIIIII V) 1111111111111111111111111111111111111 ce IIIIIIIIIIIIIIIIIIIIIIIIIIIIII n in c w w Z ( ) Z w V V H w 0 w N w 0 N Z� O --- 0) �_ 01 Lu 0 u z m�3 i - CB-3.3.1 RIMIGRA TE: 721.59 INV OUT: 716.80 50" RCP 730 -73 724 728 I I CB-3.4.7 RIMIGRA TE: 724.65 INV OUT: 720.94 18" RCP I 30 " RCP @ 1.83% / 30.00 LF W J V J W j V Ce w a b 72� a a M/�- z�,," _28-z„ ,z„ i s � i -R 726 R/ jV/W R/`�6/' R/R W RA 11 �' o - - - - - - - - - - - -7 CB-3.4 RIM/GRA TE: 724.65 ,\10 INV IN: 720.34 18" RCP /0 LF/ - - - � 1 � r N N N � Z� u.i w K� O w 6, � V = aJ'7 V � � a Q a� QZ� OJ O °c aQ N Uan PE SEAL: I SEAL � ®45345 02/21/2023 50 0 50 SCALE: I" = 50'0 ;> �e :E ; 44 (D ca IIIIIIIIIIIIIIIIIIIIIIIIIIIIII V) 1111111111111111111111111111111111111 ce IIIIIIIIIIIIIIIIIIIIIIIIIIIIII n in c w w Z ( ) Z w V V H w 0 w N w 0 N Z� O --- 0) �_ 01 Lu 0 u z m�3 N � O J w U' � r w m �.: 0 w GRADING LEGEND EXISTING CONTOUR 100 PROPOSED CONTOUR 100 ���, \ � , � � � � � I PROPOSED LIMITS OF CONSTRUCTION --------------------- PROPOSED STORM DRAINAGE EASEMENT SDE SIDE ---777— 696 PROPOSED STORM DRAINAGE PIPE PROPOSED SPOT ELEVATION (GUTTER LINE ELEV) 700 PROPOSED JUNCTION BOX PROPOSED CATCH BASIN Q�- Q�l 1Z NO PROPOSED DROP INLET -L725 uj Lu 70 11c —726 7 >< Ld — — — — — — — — — — — — — — — — — — — — 6 726.23 727 C�— 0ria 726.2 726,20 726.20 726,20 726.20 726.20 726 7266 726 VAl\ VAN 72 '72� 72S. 87 �j 725.33 c c S-4 724.91 72 72' 721 725 \ \ \\= �/ -7725��OO __�711 F- z FES-3 72 724 723— — ----- �724 7— 30 —— ------- —722— --- --------- 722---—------ -----------C -4.1 (OPEN THROAT) Z 2 ufie u 723 Cie 5 Lu a B-3.1 yl 12"— 12"W-1 B-3.4.1. - W— 12" V12" W 728 12' V, 7-� -3.1 1 Lp w U3 7234 - 724 724 '� 7 RIW—,_72j -"777— R/W—R R/W—R/W,11111111111111 �Rl��725—R W R//W—R/W--7— R/W--.--R/W VA/ AR W—K/W—K/W— 1</VV—K/W R/w R 726—R/W—R 1�1--�—R/w R/W—R —R/ w R/W w R/W 726 726 - - - - - --- - - - - - - - - - 727 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - INSTALL HARDWARE CLOTH &GRAVEL 728 728 INLET PROTECTION ON ALL NEW INLETS CN -728 - - - - - - - SEE DETAIL ON SHEET C7.4 �<- x kc) In 729 729 In 00 to 0 " 04 4 LL; Lu r � Ow J—ne r-D 0 zi 0 < Lu cle = u 2: 0 0 01 CN z 01 It PROPOSED FLARED END SECTION PROPOSED OUTLET STRUCTURE 1k PE SEAL: V A t�o PROPOSED HEADWALL �-/-A N J 0-. 1 10 �7 PROPOSED RIPRAP APRON O 01 - '�rAL o 45345 % �11 9- - ti - - - I �� \\ % - \ PROPOSED INLET PROTECTION • c(- BU(3-\- 0:0, 02/21/2023 c o Jill c(- d", cp 703 7 40 0 40 �00 1 S3 710 SCALE: I = AO 5 - 0- FES-2 \�� '\�� '___-_ _ `�� ___� _____�=______- =//.. __ = FES-1 - � ��\ - --� ----- f� � \ � �� —7Cr27:-��70 7.5 - - — - — - - 702---- �'02- INSTALL HARDWARE CLOTH& GRAVEL < 705 705 70705 INLET PROTECTION ON ALL NEW INLETS SEE DETAIL ON SHEET C7.4 63 sg 770 770 770- -770 775 -775 775 m 775 -- - 779 -779 779 7 B-2 1 B-2.1 B- 1.2 11779.59 N 7=78.96 720.0 719.32 720.0 779.32 720.0 72 > C 720.0 I--- H 0 B- 1.3 J CD 7* 99 O \ Q) \F 727,372 1 'Q 1p 72 IR. 1 A 727 5 ss —ss SS O ss —ss SST ss 0 ss ss ss ss (p ss —ss —ss —ss A ss —ss —ss —ss (p ss ss —ss a ss —ss —ss —ss 0 SS SS SS SS ss SS SS ss s ss ?; I o" i o" v,— 10', VL— �0-�*— 10 w k.4 10" VIL— I o" i o" v,— 1011 1 o I o" vv-- loll i o" N4— i o" 0 1 o" vvl-- loll, 1 o" vl`�� 1 1 o" v,,-- vll--� W-LL— 1011 (n -7� 0 722— 722 722— z 172" L 722.7 0 72V. 3- O —j l. 7 -725 725- -724- 24 z Lu Lu rd ti - C 1.5 (OPEN THROAT)", < B T) LO -7 7 O 726 - 00 bV CL Lu Z Lu 10 z 0-> Z > Lu 0 ::) in Lu 724 B u Lij Lu > Ld C'N < 0 L 3; !J 0 -Q)- O Ld FM 101, 04 C14 Z 0 N, N, C14 0 01 Lu C4 LL m Lu 0 Lu ca z C) Lu 01 Lu V) Lu Z o Lu Lu CieLu V) -0+25 0+00 74 73( 72( 71( !/I 4 , n n 7 , /1 fl M A , /1'n C� ciz: L� c nn C1 o N 6+00 -n L'2� n Lnn � �_ �® er O �c O o EXISTING GRADE PROPOSED GRADE / - - 24" RCP @ 2.00°0 24" RCP @ 2. 0�° 24" RCP @ 1.00°0 116.00 LF 36 " RCP @ 1.00% 133.40 L / 116.16 LF 3 RCP @ 0.50% 144.00 LF 59.61 LF O N 00 � n O O O n O n O n n r n Z_ � Z_ O O O O O z > z > z > z > z > 68 -0+25 0+00 / tVV L tVU STORM DRAINAGE STRUCTURE TABLE JtVV STRUCTURE NAME: DETAILS: PIPES IN: PIPES OUT RIM/GRATE: 719.32 CB 1 1 INV IN: 706.98 FROM CB-1.2, 36" RCP INV IN: 706.98 @ 1.00% TO FES-1, 36" RCP INV OUT: 702.30 @ 0.50% INV IN: 714.35 FROM CB-1.1.1, 24" RCP INV IN: 714.35 @ 0.50% INV OUT: 702.30 CB-1 1 1 RIM/GRATE: 719.32 TO CB- 1.1, 24" RCP INV OUT: 715.07 @ 0.50% INV OUT: 715.07 RIM/GRATE: 718.96 CB-1.2 INV IN: 709.42 FROM CB-1.3, 24" RCP INV IN: 709.42 @ 1.00% TO CB- 1.1, 36" RCP INV OUT: 708.42 @ 1.00% INV OUT: 708.42 RIM/GRATE: 721.50 CB-1.3 INV IN: 710.68 FROM JB-1.4, 24" RCP INV IN: 710.68 @ 2.00% TO CB-1.2, 24" RCP INV OUT: 710.58 @ 1.00% INV OUT: 710.58 CB-1.5 (OPEN THROAT) RIM/GRATE: 720.06 TO JB-1.4, 24" RCP INV OUT: 715.77 @ 2.00% INV OUT: 715.77 RIM/GRATE: 719.32 CB 2.1 INV IN: 714.35 FROM CB-2.1.1, 24" RCP INV IN: 714.35 @ 0.50% TO FES-2, 30" RCP INV OUT: 702.30 @ 0.50% INV IN: 714.35 FROM CB-2.2, 24" RCP INV IN: 714.35 @ 0.50% INV OUT: 702.30 1 1 RIMCB-2 TO CB-2.1, 24" RCP INV OUT: 715.07 @ 0.50% 715.07 INV OUT: 715.07 INV OUT: CB-2 2 RIM TO CB-2.1, 24" RCP INV OUT: 715.07 @ 0.50% INV OUT: 715.07 INV OUT: 715.07 RIM/GRATE: 721.27 CB-3.1 INV IN: 712.07 FROM CB-3.2, 42" RCP INV IN: 712.07 @ 0.50% TO FES-3, 48" RCP INV OUT: 71 1.57 @ 0.50% INV IN: 714.08 FROM CB-3.1.1, 30" RCP INV IN: 714.08 @ 8.00% INV OUT: 711.57 RIMCB-3.1.1 TO CB-3.1, 30" RCP INV OUT: 716.48 @ 8.00% INV OUT: 716.48 INV OUT: 716.48 RIM/GRATE: 721.59 CB-3.2 INV IN: 714.24 FROM CB-3.3, 36" RCP INV IN: 714.24 @ 0.50% TO CB-3.1, 42" RCP INV OUT: 713.74 @ 0.50% INV IN: 714.74 FROM CB-3.2.1, 30" RCP INV IN: 714.74 @ 6.86% INV OUT: 713.74 CB-3.2.1 RIM/GRATE: 721.59 TO CB-3.2, 30" RCP INV OUT: 716.80 @ 6.86% INV OUT: 716.80 RIM/GRATE: 721.59 CB-3.3 INV IN: 717.25 FROM CB-3.4, 18" RCP INV IN: 717.25 @ 1.50% TO CB-3.2, 36" RCP INV OUT: 715.75 @ 0.50% INV IN: 716.25 FROM CB-3.3.1, 30" RCP INV IN: 716.25 @ 1.83% INV OUT: 715.75 CB-3.3.1 RIM/GRATE: TO CB-3.3, 30" RCP INV OUT: 716.80 @ 1.83% INV OUT: 716.80 RIM/GRATE: 724.65 CB-3.4 INV IN: 720.34 FROM CB-3.4.1, 18" RCP INV IN: 720.34 @ 2.00% TO CB-3.3, 18" RCP INV OUT: 720.24 @ 1.50% INV OUT: 720.24 CB-3.4.1 RIM/GRATE: 724.65 TO CB-3.4, 18" RCP INV OUT: 720.94 @ 2.00% INV OUT: 720.94 CB-4.1 (OPEN THROAT) RIM/GRATE: 718.25 TO FES-4, 24" RCP INV OUT: 713.96 @ 2.90% INV OUT: 713.96 FES-1 INV IN: 702.00 FROM CB- 1.1, 36" RCP INV IN: 702.00 @ 0.50% FES-2 INV IN: 702.00 FROM CB-2.1, 30" RCP INV IN: 702.00 @ 0.50% FES-3 INV IN: 711.32 FROM CB-3.1, 48" RCP INV IN: 711.32 @ 0.50% FES-4 INV IN: 710.00 FROM CB-4.1 (OPEN THROAT), 24" RCP INV IN: 710.00 @ 2.90% RIM/GRATE: 725.59 JB-1.4 INV IN: 713.45 FROM CB-1.5 (OPEN THROAT), 24" RCP INV IN: 713.45 @ 2.00% TO CB-1.3, 24" RCP INV OUT: 713.35 @ 2.00% INV OUT: 713.35 4tVU -0 25 0+00 75 74( 73( 72( 71( 70( JtVV i 4nn 740 74 30 73( 20 72( 1+75 -0+25 0+00 740 75 - - ��� ca � ti Q) - ti i;c' zzz i;� z PROPOSED GRADE EXISTING GRADE 24" RCP @ 0.507. 144.00 LF L O M n Z � - O Z z 80 68 6+00 -0+25 0+00 9-/-nn l tVU 3-�nn 30 741 20 73( 10 72( 2+00 2+25 -0+25 0+00 750 75 Q- cl- cw w Lr) Ln �N-)N)N r o\ o '� o i;C'Z: PROPOSED GRADE 24" RCP @ 0.50% 144.00 LF EXISTING GRADE 3 RCP 59.61 LF O M Lo I� 0 O M N N � O 0 T n n - 0- O 4 z > z > 80 69 1+75 -0+25 0+00 /tVV '40 74( '20 72( 710 71( 700 70( � c<a w Ln � �N)�� - - o\ � � � O N � O i✓C z PROPOSED GRADE 24 " RCP @ 0.50% 144.00 LF EXISTING GRADE M 0 n Z H � - O Z 4 z 1 1 90 69 2+00 2+25 -0+25 0+00 /tVV 750 740 to 0 N N W 04 Z 4t ui w Kz O w 6, V V � � ne OZ o �O 0 Oa �U z aQ N U PE SEAL: 730 N. C A I SEAL 045345 .,�.'•��G A N' F : . 720 BUG 02/21/2023 710 PROFILE SCALES VERT. SCALE: 1 " = 8' HOR. SCALE: 1 " = 40' 700 90 1 +75 N 4+00 5+00 6+00 7+00 8+00 9+00 9+25 �a � EXISTING GRADE a Ln ti ti Z p O g:z � ZZZ v� Z Z Z / v Z Z Z PROPOSED GRADE 18 " RCP @ 1. 0/ - 36" RCP @ 0.50% 42-' RCP @ 0.50% 199.63 L -- 18 RCP @ 2�0% 303.00 LF 30.0 333.75 LF 48 " RCP @ 0.50% 49.66 LF �_O �It Ln �N Lo NM O� M r N N '� 00 N 0 N 04 z �z Sz �z �z D - O- O- O- O- O z >z >z >z >z > - z- Z- z- Z- Z 69 -0+25 0+00 ItUU LtVV JtUV 4tVV JtUV otUV /tUV OtUV -D 25 0+00 74 73( 72( 71( 70 69 750 740 1 730 W V � W Q Z J J to O J O W Z 720 ova Q W W a�z 0 W Q = Z a 0 Z 710 = Z W W �Oo V W = Q W W a� i � 700 Q CQ L O 90 9+00 9+25 1+00 1+50 5 11 N� Q c6 � PROPOSED GRADE W 3 o EXISTING GRADE 24„ RCP @ 2.90°0 136e49 LF O o c° rn � M z � - O > Z_ j z 740 W 730 720 10 700 z w 0 695 V V 0+25 0+00 1+00 1+50 � I 0 w V) N N Z ,o t!f O >r W �3 mcle CV N '^ J V� 0 r m LL w • 0 w m Z O 2 Z 3w V Z�w w�= � w O V � 7. F3.1.1 ® WET POND #2 SCALE: 1 °' = 20' 720 715 710 705 r �� 10'EMERGENCYSPILL WAY ELEV, • 7 / 8.50 o i & WIDE LITTORAL SHELF (3,426-sFJ REQUIRES 857 PLANTINGS (SO PLANTS1200-SF) 857 PLANTINGS ARE PROVIDED SEE STANDARD PLANTINGS, THIS SHEET It d RIPRAP BERM i CLASS B RIPRAP FACED W1 #57 STONE 2:1 SIDE SLOPES, 5.5' TALL 14/ i \ OUTLET STRUCTURE � �' (SEE DETAIL, THIS SHEET) 14/ - --- - - - - - - - - - - - - - - - - - _ ----- ---------------------------- ----- '1 FES-4� T----------T-------�-----�_�' •� 770.5i Al V O 770 75 M • rad riv - 775 _720 725 723 ' o' v i OOYR-24HR PEAK STAGE = 718.2 / / i / 71,5- 50YR-24HR PEAK STAGE = 717.51 - 7107 - 1 0YR-24HR PEAK STAGE = 715 83 OPEN ON TOP ELEVATION = 77 8.00 PEAKED TRASH RACK WITH ANTI VORTEX PLATE 2:1 SLOPE, WITH 2' x 3' HINGED HATCH ALIGN WITH STEPS INSIDE SECURE HATCH WITH CHAIN & LOCK TOP OF BOX @ ELEV. 718.00 (3) 36" X 6" SLOTTED WEIR @ ELEV. 715.00 PRECAST CONCRETE STRUCTURE TINDALL UV4848 OR EQUAL 48" X 48" INSIDE DIMENSIONS (MIN. 6" WALL THICKNESS) DRAINAGE STRUCTURE STEPS (TYPICAL) INV. OF 24 RCP OUTLET @ ELEV. 709.39 4.5' ORIFICE @ ELEV. 710.50 (SEE WATER QUALITY ORIFICE DETAIL, THIS SHEET) ? 2 f� 2 Y R-24HR PEAK STAGE = 714.93 - - 1 YR-24HR PEAK STAGE = 713.90 - l O'� PRECAST CONCRETE BOX TYNDALL 48"X 48"(INSIDE DIMS) _ 6' LITORAL SEE DETAIL THIS SHEET 24 RCP SHELF 6' AL (0-RING JOINTS) 6:1 (H. V) 4-6 "TOPSOIL SHELF V° 4-6" TOPSOIL 6:1 (H:V) 1 " RUNOFF VOLUME - 710.95 - TOP OF LITTORAL SHELF = 71 1.00 - �ERMANENT POOL ELEVATION = 710.50 - BOTTOM OF LITTORAL SHELF = 710.00 WATER QUALITY DRAWDOWN STRUCTURE 6"SCHEDULE 40 PVC a - i (SEE DETAIL, THIS SHEET) Q�V - C) J� FOREBAY MAIN POND as INV.=709.39 Q RIPRAP BERM AND WEIR �� d _ Q (CLASS B RIPRAP) �Q - i1i � (SEDIMENT) BOTTOM = 704.50 WET POND NOTE: IN LIEU OF MAINTENANCE DRAIN PIPE, POND TO BE MECHANICALLY PUMPED FOR MAINTENANCE. (SEDIMENT) / BOTTOM = 705.00 2' x 2' x 6 "(tJ CONCRETE PAD _ BELOW WATER QUALITY----' DRAWDOWN DEVICE WET DETENTION POND SECTION A -A NOT TO SCALE WET PON 5' x 5' x 24" CONCRETE ANTI -FLOATATION BLOCK (FILL BOTTOM OF STRUCTURE W/ 24" OF CONCRETE) • ►, 4.5" ORIFICE WATER QUALITY DRAW DOWN STRUCTURE TOP OF DAM ELEVATION = 720.00 NOT TO SCALE EMERGENCY SPILL WAY ELEVATION = 7/8.50 (SEE PLAN FOR LOCATION) ANTI -SEEP COLLARS (2 MINIMUM). COLLARS TO PROJECT 24"FROM OUTS/DE OF PIPE. MAINTAIN 24" SPACING FROM PIPE JOINTS. (SEE DETAIL, THIS SHEET 720 715 710 705 INSTSALL 8" D50 RIPRAP OVER ENTIRE WIDTH OF SPILLWAY TOP OF SPILLWAY @ ELEV. 718.50 TOP OF DAM 3:1 10' 3:1 @ ELEV. 720.00 WET POND #2 EMERGENCY SPILLWAY DETAIL NOT TO SCALE 2' 2' 12 a e d .° d d d BARREL I- d a _ d: d. NOTES: USE SIDE WALLS AND BOTTOM OF TRENCH AS FORM COMPACT OVER -EXCAVATION TO 95% DENSITY (PER ASTM D-698) CONCRETE SHALL BE 3,000-PSI CONCRETE ANTI -SEEP COLLARS TYPICAL SECTION CARDINAL FLOWER (LOBELIA CARDINALIS) SPACED @ 3.5' O.C. (1 23 TOTAL) NOT TO SCALE -6' ®6:1 SLOPE co) - + V z oc w w z C� z w to 0 N N CN� N r., Z� Ld w r2 Z OW fieCD V O7 V � � QZ� O J cl O D O� � 0 0 oa N U PE SEAL: .` YCARO • .• O10 ff•• I SEAL 045345 •'•:�G A NE��:'• ���� 02/21/2023 LONGLEAF LOBELIA (LOBELIA ELONGATA) SPACED @ 4' O.C. I CAIC41 (1 23 TOTAL) _ NARROW PLUMEGRASS (SACCHARUM BALDWINII) ice SPACED @ 2' O.C. i (488 TOTAL) i QUILL SEDGE (CAREX TENERA) SPACED @ 1.5' O.C. O (1 23 TOTAL) I \,f T C4o --/ W Lo a W z Z I� W O H LITTORAL SHELF ° U a TYPICAL PLANTING uj Q o UJ Z u =0 W NOT TO SCALE Z J =ZW W BMP MAINTENANCE NOTE N 5 W C� t� �°J a OWNERSHIP &MAINTENANCE OF BMP BELONGS TO THE OWNER ! W >� Z SEDIMENT BASIN CONVERSION NOTES a a 1. RECEIVE PERMISSION FROM THE CITY OF STATESVILLE AND DAVIE COUNTY PRIOR TO DEWATERING (email O stormwater@p statesvillenc.net) L 2. ALL SLOPES AND BOTTOM OF POND SHALL BE PREPARED & SEEDED TO PERMANENT GROUND COVER - SPECIFICATIONS. SEDIMENT 3. THE SEDIMENT BASIN SHALL NOT BE CONVERTED TO THE PERMANENT WET POND UNTIL THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED. ANY SEDIMENT THAT ACCUMULATES WITHIN THE POND SHALL BE REMOVED W AND THE FINAL GRADE REESTABLISHED TO THE PROPOSED CONTOURS SHOWN. 4. THE CONVERSION TO A PERMANENT WET POND SHALL BE ACCOMPLISHED BY REGRADING THE BASIN CONTOURS a TO THOSE SHOWN ON THE PLAN, REMOVING SKIMMER BASIN (PLUG VOID) AND CORING PERMANENT WATER QUALITY ORIFICE(S) AND INSTALLING WET POND PLANTINGS (AS SHOWN). 5. ANY SEDIMENT LADEN WATER WITHIN THE SEDIMENT BASIN SHALL BE DRAWN DOWN BY USE OF PUMPS AND DISCHARGES THROUGH A'BLADDER' TYPE SYSTEM OR DISPOSED OF OFFSITE IN AN APPROVED SYSTEM. 6. ALL SEDIMENT REMOVED SHALL BE PLACED IN A DESIGNATED SPOIL PILE AND ADEQUATELY PROTECTED WITH EROSION CONTROL MEASURES AND PERMANENTLY STABILIZED WITH PERMANENT SEEDING. WET POND MAINTENANCE REQUIREMENTS BMP ELEMENT POTENTIAL PROBLEM HOW TO REMEDIATE THE PROBLEM THE ENTIRE BMP TRASH/DEBRIS IS PRESENT REMOVE THE TRASH/DEBRIS THE PERIMETER OF THE BMP AREAS OF BARE SOIL AND/OR EROSIVE GULLIES HAVE FORMED REGRADE THE SOIL IF NECESSARY TO REMOVE THE GULLY, AND THEN PLANT A GROUND COVER AND WATER UNTIL IT IS ESTABLISHED. PROVIDE LIME AND A ONE-TIME FERTILIZER APPLICATION. VEGETATION IS TOO MAINTAIN VEGETATION AT A HEIGHT OF SHORT OR TOO LONG APPROXIMATELY SIX INCHES THE PIPE IS CLOGGED UNCLOG THE PIPE. DISPOSE OF THE SEDIMENT OFF -SITE THE PIPE IS CRACKED OR OTHERWISE DAMAGED REPLACE THE PIPE REGRADE THE SWALE IF NECESSARY TO SMOOTH THE INLET DEVICE EROSION IS OCCURRING IN THE SWALE IT OVER AND PROVIDE EROSION CONTROL DEVICES SUCH AS REINFORCED TURF MATTING OR RIPRAP TO AVOID FUTURE PROBLEMS WITH EROSION. STONE VERGE IS CLOGGED OR COVERED REMOVE SEDIMENT AND REPLACE WITH CLEAN IN SEDIMENT (IF STONE APPLICABLE) TRASH/DEBRIS IS PRESENT REMOVE THE TRASH/DEBRIS PROVIDE ADDITIONAL EROSION PROTECTION EROSION HAS OCCURRED SUCH AS REINFORCED TURF MATTING OR RIPRAP THE FOREBAY OR RIPRAP IS DISPLACED IF NEEDED TO PREVENT FUTURE EROSION PROBLEMS REMOVE THE WEEDS, PREFERABLY BY HAND. IF WEEDS ARE PRESENT PESTICIDES ARE USED, WIPE THEM ON THE PLANTS RATHER THAN SPRAYING SEARCH FOR THE SOURCE OF THE SEDIMENT AND SEDIMENT HAS REMEDY THE PROBLEM IF POSSIBLE. REMOVE THE ACCUMULATED AND SEDIMENT AND DISPOSE OF IT IN A LOCATION REDUCED THE DEPTH TO WHERE IT WILL NOT CAUSE IMPACTS TO STREAMS 75% OF THE ORIGINAL OR THE BMP. REVEGETATE DISTURBED AREAS DESIGN DEPTH (PER POND IMMEDIATELY WITH SOD (PREFERRED) OR SEED DESIGN DATA SHEET) PROTECTED WITH SECURELY STAKED EROSION THE MAIN TREATMENT AREA CONTROL MAT. ALGAL GROWTH COVERS CONSULT A PROFESSIONAL TO REMOVE AND OVER 50% OF THE AREA CONTROL THE ALGAL GROWTH CATTAILS, PHRAGMITES OR OTHER INVASIVE PLANTS REMOVE THE PLANTS BY WIPING THEM WITH COVER 50% OF THE BASIN PESTICIDE (DO NOT SPRAY) SURFACE SHRUBS HAVE STARTED TO GROW ON THE REMOVE SHRUBS IMMEDIATELY EMBANKMENT EVIDENCE OF MUSKRAT USE TRAPS TO REMOVE MUSKRATS AND CONSULT OR BEAVER IS PRESENT A PROFESSIONAL TO REMOVE BEAVERS THE EMBANKMENT A TREE HAS STARTED TO GROW ON THE EMBANKMENT CONSULT A DAM SPECIALIST TO REMOVE THE TREE AN ANNUAL INSPECTION BY AN APPROPRIATE PROFESSIONAL SHOWS MAKE ALL NEEDED REPAIRS THATTHEEMBANKMENT NEEDS REPAIR. CLOGGING HAS CLEAN OUT THE OUTLET DEVICE. DISPOSE OF THE OCCURRED SEDIMENT OFF -SITE THE OUTLET DEVICE THE OUTLET DEVICE IS DAMAGED REPAIR OR REPLACE THE OUTLET DEVICE EROSION OR OTHER CONTACT THE LOCAL INC DEPARTMENT OF THE RECEIVING WATER SIGNS OF DAMAGE HAVE ENVIRONMENT AND NATURAL RESOURCES OCCURRED AT THE OUTLET REGOINAL OFFICE 0 uj \ N 5 ce N N F- Z w CZ O::E < J � O Cie L ~ O VZQCJ u03Lu 0 Cie V w O ne CI_ a N w Lu Lu L a to cn cn w N w w w > Cie fle ce w . . ne CV CV CV ' N CV N M N \\\N Z -o ao \ 0 -0--7_--_C11 M C) r N CWC V vi 6 m�3C�e CV M 01 0 J V� wmm o w w O Z Lu 2 r Z 3 Lu se to Lu Z � wLu w0= w a N V a 710 .J r 705 - OOYR-24HR PEAK STAGE = 705.62100 50 OYR-24HR PEAK STAGE = 705.38 OYR-24HR PEAK STAGE = 704.83- _ OPEN ON TOP ELEVATION = 708.00 1 PRECAST CONCRETE BOX 1 2YR-24HR PEAK STAGE = 703.56 TYNDALL 48"X 48"(INSIDE DIMS) 1 YR-24HR PEAK STAGE = 703.09 SEE DETAIL, THIS SHEET _ _ SHELF 6' LITORAL 6.1 (H.V) 4-6 TOPSOIL SHELF 1„ 4-6 TOPSOIL 6.1 (H. V) - 1 " RUNOFF VOLUME - 701.79 -TOP OF LITTORAL SHELF = 702.00 PERMANENT POOL ELEVATION = 701.50 + - - - BOTTOM OF LITTORAL SHELF = 701.00 RIPRAP BERM AND WEIR ,` WATER QUALITY DRAWDOWN STRUCTURE a (CLASS 8 RIPRAP) ' 6"SCHEDULE40PVC a 700 J (SEE DETAIL, THIS SHEET) FOREBAY MAIN POND 0710 (SEDIMENT) (SEDIMENT) BOTTOM = 697.50 BOTTOM - 698.00 2' x 2' x 6 "(t) CONCRETE PAD [� 695 - -BELOW WATER QUALITY - - WET POND NOTE' DRAWDOWN DEVICE IN LIEU OF MAINTENANCE DRAIN PIPE, POND TO BE MECHANICALLY PUMPED FOR MAINTENANCE. WET DETENTION POND SECTION A -A NOT TO SCALE e WET POND #3 SCALE. 1 " = 30' TOP OF DAM ELEVATION = 77 0.00 24"RCP _ - (O-RING JOINTS) INV. = 70 7.3 9 L\ - EMERGENCY SPILLWAY - ELEVATION = 708.50 (SEE PLAN FOR LOCATION) ANTI -SEEP COLLARS (2 MINIMUM). COLLARS TO PROJECT 24"FROM OUTSIDE OF PIPE. MAINTAIN 24" SPACING FROM PIPE JOINTS. (SEE DETAIL, THIS SHEET 710 705 700 695 PEAKED TRASH RACK WITH ANTI VORTEX PLATE 2:1 SLOPE, WITH 2' x T HINGED HATCH ALIGN WITH STEPS INSIDE SECURE HATCH WITH CHAIN & LOCK TOP OF BOX @ ELEV. 708.00 (2) 36" X 6" SLOTTED WEIR @ ELEV. 705.00 PRECAST CONCRETE STRUCTURE TINDALL UV4848 OR EQUAL 48" X 48" INSIDE DIMENSIONS (MIN. 6" WALL THICKNESS) DRAINAGE STRUCTURE STEPS (TYPICAL) INV. OF 24" RCP OUTLET @ ELEV. 701.39 4.5' ORIFICE @ ELEV. 701.50 (SEE WATER QUALITY ORIFICE DETAIL, THIS SHEET) 5' x 5' x 24" CONCRETE ANTI -FLOATATION BLOCK (FILL BOTTOM OF STRUCTURE W/ 24" OF CONCRETE) CARDINAL FLOWER (LOBELIA CARDINALIS) SPACED @ 3.5' O.C. 0 6:1 SLOPE- (1 I Z TOTAL) I I I I ) i LONGLEAF LOBELIA I + (LOBELIA ELONGATA) co I-) SPACED @ 4' O.C. I (1 12 TOTAL) NARROW PLUMEGRASS _ (SACCHARUM BALDWINII) SPACED @ 2' O.C. (444 TOTAL) t I QUILL SEDGE C4 i I-) (CAREX TENERA) SPACED @ 1.5' O.C. (1 12 TOTAL) co 0-) CN LITTORAL SHELF TYPICAL PLANTING NOT TO SCALE INSTSALL 8" D50 RIPRAP OVER ENTIRE WIDTH OF SPILLWAY TOP OF SPILLWAY @ ELEV. 708.50 TOP OF DAM 3:1 10' 3:1 @ ELEV. 710.00 WET POND #3 EMERGENCY SPILLWAY DETAIL NOT TO SCALE �2 2 a as . a. I G 4 A OBARREL .44°. u . Ll °,. ° a NOTES: USE SIDE WALLS AND BOTTOM OF TRENCH AS FORM COMPACT OVER -EXCAVATION TO 95% DENSITY (PER ASTM D-698) CONCRETE SHALL BE 3,000-PSI CONCRETE ANTI -SEEP COLLARS TYPICAL SECTION NOT TO SCALE 4.5" ORIFICE WATER QUALITY DRAW DOWN STRUCTURE NOT TO SCALE �= BMP MAINTENANCE NOTE \ \ OWNERSHIP & MAINTENANCE OF BMP BELONGS TO THE OWNER BA I ER NOTES SEDIMENT BASIN CONVERSION SON NO S RCQ i 1 RECEIVE PERMISSION FROM THE CITY OF STATESVILLE AND DAVIE COUNTY PRIOR TO DEWATERING (email WET POND #3 OUTLET STRUCTURE NOT TO SCALE stormwater@statesvillenc.net) 2. ALL SLOPES AND BOTTOM OF POND SHALL BE PREPARED & SEEDED TO PERMANENT GROUND COVER SPECIFICATIONS. 3. THE SEDIMENT BASIN SHALL NOT BE CONVERTED TO THE PERMANENT WET POND UNTIL THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED. ANY SEDIMENT THAT ACCUMULATES WITHIN THE POND SHALL BE REMOVED AND THE FINAL GRADE REESTABLISHED TO THE PROPOSED CONTOURS SHOWN. 4. THE CONVERSION TO A PERMANENT WET POND SHALL BE ACCOMPLISHED BY REGRADING THE BASIN CONTOURS TO THOSE SHOWN ON THE PLAN, REMOVING SKIMMER BASIN (PLUG VOID) AND CORING PERMANENT WATER QUALITY ORIFICE(S) AND INSTALLING WET POND PLANTINGS (AS SHOWN). 5. ANY SEDIMENT LADEN WATER WITHIN THE SEDIMENT BASIN SHALL BE DRAWN DOWN BY USE OF PUMPS AND DISCHARGES THROUGH A'BLADDER' TYPE SYSTEM OR DISPOSED OF OFFSITE IN AN APPROVED SYSTEM. 6. ALL SEDIMENT REMOVED SHALL BE PLACED IN A DESIGNATED SPOIL PILE AND ADEQUATELY PROTECTED WITH EROSION CONTROL MEASURES AND PERMANENTLY STABILIZED WITH PERMANENT SEEDING. WET POND MAINTENANCE REQUIREMENTS BMP ELEMENT POTENTIAL PROBLEM HOW TO REMEDIATE THE PROBLEM THE ENTIRE BMP TRASH/DEBRIS IS PRESENT REMOVE THE TRASH/DEBRIS THE PERIMETER OF THE BMP AREAS OF BARE SOIL AND/OR EROSIVE GULLIES HAVE FORMED REGRADE THE SOIL IF NECESSARY TO REMOVE THE GULLY, AND THEN PLANT A GROUND COVER AND WATER UNTIL IT IS ESTABLISHED. PROVIDE LIME AND A ONE-TIME FERTILIZER APPLICATION. VEGETATION IS TOO MAINTAIN VEGETATION AT A HEIGHT OF SHORT OR TOO LONG APPROXIMATELY SIX INCHES THE PIPE IS CLOGGED UNCLOG THE PIPE. DISPOSE OF THE SEDIMENT OFF -SITE THE PIPE IS CRACKED OR OTHERWISE DAMAGED REPLACE THE PIPE REGRADE THE SWALE IF NECESSARY TO SMOOTH THE INLET DEVICE EROSION IS OCCURRING IN THE SWALE IT OVER AND PROVIDE EROSION CONTROL DEVICES SUCH AS REINFORCED TURF MATTING OR RIPRAP TO AVOID FUTURE PROBLEMS WITH EROSION. STONE VERGE IS CLOGGED OR COVERED REMOVE SEDIMENT AND REPLACE WITH CLEAN IN SEDIMENT (IF STONE APPLICABLE) TRASH/DEBRIS IS PRESENT REMOVE THE TRASH/DEBRIS PROVIDE ADDITIONAL EROSION PROTECTION EROSION HAS OCCURRED SUCH AS REINFORCED TURF MATTING OR RIPRAP THE FOREBAY OR RIPRAP IS DISPLACED IF NEEDED TO PREVENT FUTURE EROSION PROBLEMS REMOVE THE WEEDS, PREFERABLY BY HAND. IF WEEDS ARE PRESENT PESTICIDES ARE USED, WIPE THEM ON THE PLANTS RATHER THAN SPRAYING SEARCH FOR THE SOURCE OF THE SEDIMENT AND SEDIMENT HAS REMEDY THE PROBLEM IF POSSIBLE. REMOVE THE ACCUMULATED AND SEDIMENT AND DISPOSE OF IT IN A LOCATION REDUCED THE DEPTH TO WHERE IT WILL NOT CAUSE IMPACTS TO STREAMS 75% OF THE ORIGINAL OR THE BMP. REVEGETATE DISTURBED AREAS DESIGN DEPTH (PER POND IMMEDIATELY WITH SOD (PREFERRED) OR SEED DESIGN DATA SHEET) PROTECTED WITH SECURELY STAKED EROSION THE MAIN TREATMENT AREA CONTROL MAT. ALGAL GROWTH COVERS CONSULT A PROFESSIONAL TO REMOVE AND OVER 50% OF THE AREA CONTROL THE ALGAL GROWTH CATTAILS, PHRAGMITES OR OTHER INVASIVE PLANTS REMOVE THE PLANTS BY WIPING THEM WITH COVER 50% OF THE BASIN PESTICIDE (DO NOT SPRAY) SURFACE SHRUBS HAVE STARTED TO GROW ON THE REMOVE SHRUBS IMMEDIATELY EMBANKMENT EVIDENCE OF MUSKRAT USE TRAPS TO REMOVE MUSKRATS AND CONSULT OR BEAVER IS PRESENT A PROFESSIONAL TO REMOVE BEAVERS THE EMBANKMENT A TREE HAS STARTED TO GROW ON THE EMBANKMENT CONSULT A DAM SPECIALIST TO REMOVE THE TREE AN ANNUAL INSPECTION BY AN APPROPRIATE PROFESSIONAL SHOWS MAKE ALL NEEDED REPAIRS THAT THE EMBANKMENT NEEDS REPAIR. CLOGGING HAS CLEAN OUT THE OUTLET DEVICE. DISPOSE OF THE OCCURRED SEDIMENT OFF -SITE THE OUTLET DEVICE THE OUTLET DEVICE IS DAMAGED REPAIR OR REPLACE THE OUTLET DEVICE EROSION OR OTHER CONTACT THE LOCAL NC DEPARTMENT OF THE RECEIVING WATER SIGNS OF DAMAGE HAVE ENVIRONMENT AND NATURAL RESOURCES OCCURRED AT THE OUTLET REGOINAL OFFICE V Z oc w w Z (D Z W to 0 N N W N � Z� ui w u� Z OW � V O7 V � � QZ� OO 00 Oa = U Z oa 0 N Z U It PE SEAL: CARO Y\ .• O �� • 10 I SEAL 045345 % GGGF 02/21/2023 z c1l) 0 0 Z O CL W 1 V Q J LLJ Z � Z ° W ME � H L V W QCleW Z =ZZa W V ,,^^ ' 0 V W =ZW W N�o(D °J a V = W >� Z 000 a L::E. 44 ad W a O W Fmm N N F Z w CZ O�C < J � G ~ O O 0 �- a u030 Cie " V w O � ne a 0- N w Lu Lu Lu a 0 to cn cn w N w w w > CieQe oe w oe CV N CV . N N N C) N \\\N Z .0 ao \ O ��� CN t/f C) r N CWC _: V vi CV ol w O J Lu wmm o w LL O Lu Z 2 Z 3 w � �, Lu z w w�= Lu w o V V a I I \ I NNIII „y ! I !lj ��xs ,; �I s • • .. .. I i I N N B !� i I c I r i _ J FM - -------- - - � > — ,, I 1 1 Dr I 1 III I I I11J 1 IIIII � '-9 1 I I I _ I I - I L I I J - y _ > ... ... .. .... ., _... .._,, ... ....,.< ... ., ._ .,:,: .. F.P., i � 3 V � � 25x25 SIGHT TRIANGLES TrW _r� H_H+� _L L M �m� t H — A � R/W R R/W PLANTING SCHEDULE QTY BOTANICAL NAME COMMON NAME LOCATION TYPE ROOT PLANTING / SPACING CONTAINER HEIGHT /SIZE 9 LAGERSTROEMIA INDICA'CATAWBA' CRAPE MYRTLE'CATAWBA' STREET SMALL B & B MIN. 8' TALL 25' O.C. 13 NYSSA SYLVATICA BLACK GUM STREET LARGE B & B MIN. 2.5" CALIPER 40' O.C. \ 28 PRUNUS CAROLINIANA CAROLINA CHERRY LAUREL PARKING SMALL 5 GAL MIN. 3' TALL 5' O.C. J cy 28 QUERCUS PHELLOS WILLOW OAK STREET LARGE B & B MIN. 2.5" CALIPER 40' O.C. / 7 THUJA STANDISHII X PLICATA ' GREEN GIANT' GREEN GIANT ARBORVITAE TRUCK COURT LARGE B & B MIN. 8' TALL 15' O.C. 3 \ LANDSCAPING CALCULATIONS PE SEAL: 25x25 SIGHT TRIANGLES GREEN GIANT ARBORVITAE (14) TRUCK COURT LANDSCAPING WILLOW OAK (29) STREET LANDSCAPING CRAPE MYRTLE 'CATAWBA' (14) STREET LANDSCAPING BLACK GUM (32) STREET LANDSCAPING CAROLINA CHERRY LAUREL (200) PARKING LANDSCAPING • b . M/ . . 8 a /21. M/21 M/8 . M/8 M Y _ 1 9^ R/W R/W R/W R/W R/W -------------- NEW PUBLIC ROAD ------- SEE SHEET C6.0 Loi —_ 2 V z oc w w z C� z w to Q N N W N � Z � ua w r z Z OW J V O7 V o QZ � O O 00 Oa �U �0 0 Qa N Or It PARKING LANDSCAPING REQUIRED �� N CARD INDUSTRIAL PARKING AREA: TYPE C BUFFER REQUIRED (10' WIDE) O�/>'; ROW OF EVERGREENS AT MINIMUM OF 5' APART TO FORM CONTINUOUS HEDGE OF MIN. OF b' SEAL �r IN HEIGHT WITHIN 2 YEARS OF PLANTING (LAWN, LOW -GROWING EVERGREEN SHRUBS, 045345 EVERGREEN GROUND COVER, OR ROCK MULCH COVERING THE BALANCE OF THE BUFFER) r• ' !0AN' 0 \% 200 SMALL TREES PROVIDED ♦♦�i �� g�A��**% STREET LANDSCAPING REQUIRED:, 02/21/2023 1 TREE PER 40-LF OF FRONTAGE NEW INTERNAL ROAD FRONTAGE: 32 LARGE TREES PROVIDED US HMIY 158 FRONTAGE: 29 LARGE TREES & 14 SMALL* TREES PROVIDED (*DUE TO OVERHEAD POWER LINES) LANDSCAPING KEY 50 0 50 SCALE: 1 " = 50' .0 I'D 639 F 25x25 SIGHT TRIANGLES/ WILLOW OAK CRAPE MYRTLE 'CATAWBA' 'ITAE N 4> - CAROLINA %;o; CHERRY LAUREL AREA TO BE SODDED In 0 LANDSCAPE NOTES m 1. EXISTING VEGETATION LOCATED ON SITE MAY BE SUBSTITUTED ' SO LONG AS URBAN FORESTRY REQUIREMENTS ARE MET. COORDINATE ONSITE WITH URBAN FORESTER. 2. ALL TREES 8-INCHES OR GREATER IN DIAMETER AND LOCATED WITHIN PERIMETER BUFFER YARDS SHALL BE PROTECTED UNTIL Q J REMOVAL IS CONFIRMED WITH ZONING ADMINISTRATOR. Lu Z tri 3. ALL TREES 2-INCHES OR GREATER IN DIAMETER AND LOCATED J W WITHIN PUBLIC RIGHT-OF-WAY SHALL BE PROTECTED UNTIL Cie REMOVAL IS CONFIRMED WITH URBAN FORESTRY INSPECTOR. co Q p� 4. PLANT SPECIES MAY BE SUBSTITUTED DEPENDING ON TIME OF z Lei r U PLANTING, AVAILABILITY, ETC. UPON APPROVAL OF URBAN = FORESTER AND AS LONG AS PLANT SELECTION, TYPE, SPACING MEETING DAVIE COUNTY'S LANDSCAPING ORDINANCE. W >- a � O Z � V3 a =ZOCL L�J a = Z W W V N ::) O in Lu I W >> Z 00 II+ � i a _ 3 WR/ R/W R/W R/W R/ R����l R/W � R/W -------------- ------------------ -- - -- i � EXISTING RAW K p I V) F_ z O V Cie a 0 w Cie w m,_3 N O01 LL , Lu J o LL w O wmm ZzLu �*Lu _ r 3 se to Lu z�w w0= Lu w o N V � O � � C � C N vo L� ' NEW PUBLIC ROAD O PROPOSED 60' PUBLIC RIGHT-OF-WAY y to 0 N N N � Z� Lll w r u� Z Ow f V O7 V 2E c CD oZ--,a,�0 o LU OU O� 0 oa 0 N z 01 It --------~ - ---- ~ - a --~--------- ~ -- ~ -----~--------- ~ ---- -� ---- a �, a co � + -- -- -- - ----- + -- ------ �-------- � PE SEAL: M/ M/21 M b /21 /Z] M/21 /21 M M/21 M/d M/21 1�, b M b �� M/21 M/21 M M 21 M b M/21 MIN M b \ 8 CB-3.4.1 CB-3.3.1 �- CB-3.2.1 CB-3.1.1 \ N•• CA��� - - - - - CB-3.4 - SEAL � S ,ZI '1 „ZI -M.�� M..ZI M..ZI '1 „ZI ,�ZI ��Zl M��ZI N�„Zl '1„ZI ..ZI-..ZI N�„Zl l ,�Ll •\..ZI ..Zl Ll G/ •:��n ��•• •��♦ „ I „ZL ZL „ZL •'.„Z „ZL „ZL ;, M„ZL //r V „ZIN, '1„ZI „Zl •',„ZI ",„ZI „ZI A-\",� ♦ R RAW R R � AW (OPEN THROE E RAWR/RAW RAW RAW R RRCB-4.1 ♦� ••••••� g� 02/21 /2023 �fi1�-( `S�- - FES-3 z I ��E / L m rnpal �- .W 3 � N 5 cam' m m D � Z m 4-1 0 75( 74( 73( 72( 71( 70( N CB-1.5 (OPEN THROAT) N N JB-1.4 a Ib Ib Ib M„OL M„OL ---AA,.OL "".„OL M„OL „OL „OL „OL "1„OL M,„OL M.„OL „0L „OL „OL "1„OL M,„OL ,M,.OL m,,OL „OL SSA SS SS is �� SS SS SS -0- SS SS SSA- SS SS -o- SS SS SSA SS SS SSA- SS SS SSA- SS SS SSA SS SS 9 CB-1.3 J? i FES-1 FES-2 E FES-4 ` LI E SCALE: 1 " = 40' o cam, cia:- rn 00 1 a �a �cb u I, III \ cN kQ z , LO X X X cb C 4 I I AOL N +11 / TVV LTVV JTVV `FTVV JTVV VTVV /TVV OTVV ,7TVV / VTVV / /TVV / LTVV / JTVV / `FTVV /JTVV 10 Q H 0, �[ r M PVI TA: 10+81.28 PV STA: 15+16.25 Lu m PVI ELEV: 723.33 VI ELEV: 726.99 < w PVI STA: PVI ELEV: 723.33 60.00 LVC: 70.00 il�O Lu 30.00 K:30.00 BVCS: 10+51.28BVCS: 14+81.25 LVC: 60.00 BVCE:723.03 BVCE:726.11 BVCS: +48.28 EVCS: 11 +1 1.28 VCS: 15+51.25 BVCE: 723.03 EVCE: 723.03 EVCE: 726.64 - -€VC 723.03 LOW PT ELEV: ??? LOW PT ELEV: ??? 3 0% LOW PT. STA:? HIGH PT. TA: 10+81.28 HIGH PT STA: 15+31.25 _375/ LOW PTELEV: ??? HIGH PT ELEV: 723.18 HIGH PT ELEV: 726.74 HIGH PT. STA: +78.28 HIGH PT ELEV 723.18 \ 2.50% -1.00% 1.00% -1.00% 1.00% _ -1.00%- PVI ST : 0+43.81 PVI ELEV: 736.46 PVI STA 2+20.69 K: 10.00 PVI TA: 5+ 1 .1 LVC: 67.48 PVI ELEV: 729.83 PVI ELEV: 722.90 PVI STA: 6 26.78 BVCS: 0+10.07 K: 50.0 K: 50.00 PVI ELEV: 21.82 PVI STA: 9 29.78 PVI STA: 1 2+87.4 BVCE: 735.45 LVC: 71 04 K: 30.00 721 82 PVI ELEV: 721.27 EVCS: 0+77.55 BVCS: 1 +85.17 BVCSV4+84.46 LVC: 60.0 K: 30 00. K: 30.00 EVCE: LOW 735.20 T. STA: ??? EVCS: 2 500 EVCS: 5+51.36 BVCS: 5+ BVCE: 722.12 6.78 BVCS: 8+9 .78 +34.97 BVCS: 121.79 LOW T ELEV: ??? EVCE: ? 9.00BVCE: EVCE: 722.57 EVCS: 6+ 6.78 BVCE: 722.1 2 721.79 HIGH T. STA: 0+40.05 LOW PT. STA: 2+56.21 LOW PT. STA: 5+51.36 EVCE: 722 1 2 EVCS: 9+5 .78 EVCS: 1 3+39.97 HIGH T ELEV: 735.90 LOW P ELEV: 729.00 LOW PT ELEV: 722.57 LOW PT. TA: 6+26.78 EVCE: 722.12 EVCE: 722.58 HIGH P HIGH P" .STA: ??? ELEV: ?22HIGH HIGH PT. STA: ??? LOW PT E EV: 721.97 LOW PT. S A: 9+29.78 LOW PT. STA: 1 2 64.97 PT. TA: ??? LOW PT ELEV: HIGH PT. S 721.97 A: ??? HIGH PT. STA: ??? HIGH PT ELEV: ??? HIGH PT ELEV: ??? HIGH PT ELEV: ??? >lnn )inn zlnn Alnn Senn alnn 71nn S71nn alnn Inlnn 111nn 1)lnn lzlnn 1Ainn 1Sinn 1Si 69 -0+25 0+00 m N r O Lu �w0 J o LL Lu Z z o LuO v = 4 11% to 0 z w Lu w V � i i �J* kp) o0 PROP 250,000 GAL ON -GRADE WATER STORAGE TANK (DESIGN BY OTHERS � X X X —�� i' ♦ X PROP FIRE PUMP \ (DESIGN BY OTHERS) loll i \ 3 \ X X X \ 3 Q 3 / C1 Lo \ _ L C Lr) ��m� �0 o o NEW PRIVATE WATER MAIN. o m ? PROP 8" DIP WATER TANK FILL LINE .o PROP FH ASSEMBLY 12"X6" TEE !� 12 "X8" REDUCER \ Z \ + UTILITY LEGEND EXISTING WATERLINE PROPOSED WATERLINE/FIRE LINE (SIZE) FIRE HYDRANT HOSE PULL PROPOSED FIRE HYDRANT PROPOSED GATE VALVE PROPOSED WATER METER PROPOSED BACK FLOW PREVENTER PROPOSED FIRE DEPARTMENT CONNECTION EXISTING SANITARY SEWER LINE EXISTING SANITARY SEWER MANHOLE PROPOSED SANITARY SEWER LINE PROPOSED SANITARY SEWER EASEMENT PROPOSED SANITARY SEWER CLEANOUT PROPOSED SANITARY SEWER MANHOLE NO ---w----w 0 FDC ---ss ----SS O ss SS_SS SSE SSE — 0 M IPROP PRIVATE FIRE 1 III SERVICE LINE (BLDG 2). IIIIII II SEE SHEET C3.1 IIIIII IIII IIIII PROP 8" GV IiIIII� III PROP 8" RPZ BACKFLOW I I' PER STD DET 4.09 PROP 8" GV II�iIII� I, 1 11 ii \\\\ /w PROP 12" 45° BEND Ii' IFS INSTALL MJ TEE w/ 2" NPT BRANCH AND 2" GATE VALVE FOR DOMESTIC SERVICE R/W 3 N 01 6 o SS SS SS o SS SS SS o SS SS SS SS SS SS o SS SS SS SS SS SS SS SS o S SS SS - SS i o° W i o° w 1 o° 1 o'. W 1 o° W----�,_ PROP FH ASSEMBLY 12" W 12" W 12" W 12" w—�y2 m PROPOSED BUILDING 2 �R f1 � IIIII i NEW PUBLIC ROAD SEE SHEET C6.0 NEW PUBLIC WATER MAIN. 1527 LF OF 12" DR14 350 PSI C900 PVC 4 6 \/a nn/a nn/a nn a7L&a 12" 12" W W 12" 12" 2"'A— 12" Yv�R/W R/W O W R R/V R/W R/W R/ O O Q INSTALL MJ TEE w/ 2" NPT BRANCH AND 2" GATE VALVE FOR DOMESTIC SERVICE. PROVIDE A 2X2X 1 MUELLER H-15381 N PG. 6.24 FITTING FOR IRRIGATION CONNECTION TO 2" WATER LINE 2 V Z W w Z CD Z (:)LU to 0 W N N � Z4t ui w u� Z Ow J U O7 V � � O? OZ--ale �O o Oa = U Z L2 0 � 0 oa 0 [N Z U It PE SEAL: A01.. 1 Y\ ....... 0� / �i, I SEAL 045345 %'•:�G A N' 02/21/2023 50 0 50 SCALE: 1" = 50' 3 3 a v 3 c N UA z� a w OB 3 w � c � W w LLJ _Z vi J W �I N" O Z W �. Cie � U l Lu ao:z- ~ W F � =Z0 >- � EdW V w =ZLu Q W W J Ly Lu N a PROP 8 Wx20 Lx4 D ; Se BORE PIT 0 O (3' MIN OFF EX EOP) _T z 0 PROP 8'WxIO Lx4'D 3 RECEIVING PIT (3' MIN OFF EX EOP) 3 PROP FH ASSEMBLY v L � �e 4 r .R/yy /" O c ll + %&I O ry CAC JACK AND BORE 12" WATERMA/N T U IN A 20" (T=0.250") STEEL CASING w/ 3 SPIDERS PER JOINT N ck- 6X6 TAPPING SLEEVE/TEE, 6" GATE VALVE. STANDARD 'U' CONNECTION PER DETAILS 2.03. REPLACE LOWER 90-DEGREE BEND w/ 12X6 TEE. CONNECT TO EX. 6" WATERMAIN AFTER SUCCESSFUL TESTING AND SAMPLING. RP BACKFLOW DEVICES MUST BE TESTED AND CERTIFIED. O I ry I N N Z � � �33 0 V V V J J 12X6 TEE v Cie0-CL 12GV www a a 0 0 0 12 MJ CAP N N N w/ THRUST BLOCK > > > Lu Lu FOR FUTURE CONNECTION � Qe ce 1 CV CV CV I I N \\\ 1 Z o cv v r�12" O ��� N 0 m�3 0- J Lu U— o 0 wmm Z Zp Lu _41%0 v 3W V Lu Z�w Lu Lu W�= o V V CG d 1/2" RADIUS I 3" RADIUS �d ° e d, d . da. .$ c' ,_ 2s" STANDARD 2'-6" CURB AND GUTTER rs" V-6" 3" RADIUS e nd N i0 40 a n a' t. d. a 2'-0" STANDARD CURB & GUTTER 1/2" RADIUS 1/8" RADIUS V 3" RADIUS d: 1/8" RADIUS N a d' a l'-6" STANDARD CURB AND GUTTER V-6" " RADIUS L3J S a°a a 0? FT/FT N t 4 J�J� d a as .d e .03 FT/FT SLOPE FOR VARIABLE SUPERELEVATION RATES STANDARD CURB AND GUTTER O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O p 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C4 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O 4'-O" MIN. WIDTH COVERED WITH DETECTABLE WARNING MAT NOTES: 1. ALL DETECTABLE WARNING DEVICES USED /N NEW CONSTRUCTION SHALL BE OF A R/DG/D PRECAST OR EMBEDDED PRODUCT APPROVED BY THE CITY ENGINEER. RETRO FIT MATS WILL ONLY BE ALLOWEED ON EXISTING RAMPS WITH PRIOR APPROVAL OF THE CITY ENGINEER FOR MATERIAL TYPE AND INSTALLATION (IE. RESURFACING). 2. RAMP AND DETECTABLE WARNING AREA SHALL BE A MINIMUM OF 4 FEET /N WIDTH, BUT NOT BE LESS THAN THE WIDTH OF SIDEWALK LEADING TO BACK OF RAMP. 3. DETECTABLE WARNING SURFACES SHALL EXTEND 2.0 FT MINIMUM /N THE DIRECTION OF PEDESTRIAN TRAVEL. 4. DETECTABLE WARNING AREA CAN BE SQUARE WHERE USED IN A CURB RADIUS 5. THE ROWS OF TRUNCATED DOMES IN DETECTABLE WARNING SURFACES SHOULD BE ALIGNED PERPENDICULAR TO THE GRADE BREAK BETWEEN THE RAMP RUN AND THE STREET. WHERE DETECTABLE WARNING SURFACES ARE PROVIDED ON A SURFACE WITH A SLOPE THAT IS LESS THAN 5 PERCENT, DOME ORIENTATION /S LESS CRITICAL. 6. DETECTABLE WARNING AREA SHALL BE A RED FIBERGLASS MAT. 7. IF PAVERS ARE TO BE USED, PAVERS SHALL BE 6" THICK AND CAST FROM 5000 psi CONCRETE. B. MATS ARE TO BE RIGID WITH TURN DOWN EDGES EMBEDDED /N CONCRETE TO ELIMINATE TRIP HAZARD, 9. DIMENSIONS PER NCDOT 848.06 TRUNCATED DOMES PLAN AND CROSS-SECTION .03 FT/FT NOT TO SCALE 0.65" (1.6" TO 2.4") 2.4") TRUNCATED DOME SPACING 50%-65% OF BASE DIAMETER I0 0.2" F� TRUNCATED DOME SECTION NOT TO SCA JOINT SEALER 1 /8" RADIUS (TYPICAL) as °' 4. s de JOINT FILLER TRANSVERSE EXPANSION JOINT NOTES: 1. CONTRACTION JOINTS SHALL BE SPACED AT 10-FOOT INTERVALS. FOR VALLEY GUTTER, A 10-FOOT SPACING MAY BE USED WHEN A MACHINE IS USED. JOINT SPACING MAY BE ALTERED BY THE CITY ENGINEER TO PREVENT UNCONTROLLED CRACKING. 2. CONTRACTION JOINTS MAY BE INSTALLED BY THE USE OF TEMPLATES OR FORMED BY OTHER APPROVED METHODS. WHERE SUCH JOINTS ARE NOT FORMED BY TEMPLATES, A MINIMUM DEPTH OF 1 1/2" SHALL BE OBTAINED. J. ALL EXPANSION JOINTS SHALL BE SPACED AT 90-FOOT INTERVALS, AND ADJACENT TO ALL RIGID OBJECTS. JOINTS SHALL MATCH LOCATIONS WITH JOINTS IN ABUTTING SIDEWALK. 4. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3600 P.S.I. IN 28 DAYS. CURB SHALL BE DEPRESSED AT INTERSECTIONS TO PROVIDE FOR FUTURE ACCESSIBLE RAMPS. 5. TOP 6" OF SUBGRADE BENEATH THE CURB AND GUTTER SHALL BE COMPACTED TO 100% STANDARD PROCTOR DENSITY. NOT TO SCALE CURB AND GUTTER PARKING SPACE PAVEMENT MARKINGS SIGNAGE ACCESSIBLE PARKING REQUIREMENTS (MUST NOT OBSTRUCT ACCESSIBLE ROUTE ACCESSIBLE ROUTE TOTAL PARKING SPACES PROVIDED MINIMUM NUMBER OF ACCESSIBLE SPACES SPACES REQUIRED MINIMUM NUMBER OF ACCESSIBLE SPACES REQUIRED TO BE VAN ACCESSIBLE 1 TO 25 1 1 26 TO 50 2 1 51 TO 75 3 1 76 TO 100 4 1 101 TO 150 5 1 151 TO 200 6 1 201 TO 300 7 2 301 TO 400 8 2 401 TO 500 2 2 501 TO 1000 2% OF TOTAL 1 IN EVERY 6 ACCESSIBLE SPACES 1001 AND OVER 20 PLUS 1 FOR EACH 100 OVER 1000 1 IN EVERY 6 ACCESSIBLE SPACES REFERENCE: SECTION 1106 OF NC BUILDING CODE SEE NOTE 2 SEE MUNICIPALITY STANDARDS FOR DIMENSIONS ON ONEOUTOF EVERY SIX (6) ACCESSIBLE 11' S' 8' e' e' 8' 5' 8' SPACES, BUT NOT LESS THAN ONE, IS REQUIRED TO BE VAN VAN VAN ACCESSIBLE, PER ACCESSIBLE ACCESSIBLE SECTION 1 OF BUIL SPACE SPACE NC STATE BUILDING CODE (OPTION 1) (OPTION 2) O MUTCD VAN R7-SP NO MUTCD RESERVED ACCESSIBLE 12`x6` PARKING �"x'B" PARKING MUTCD ® R7-8 RESERVED ,2"x18" NOTES: PARKING R7-8 ANY I AT 7 FEET SFROMSIGNS GRADE TO BOTTOM EDGE IOF SIGN OF C£(MUTCD).MMOUNTING Y IBLE LL BE OUNTED 1x18" TIME HEIGHT CAN BE REDUCED TO 5 FEET IF PLACED IN AN AREA BETWEEN SIDEWALK AND BUILDING FACE IN WHICH PEDESTRIANS ARE NOT EXPECTED TO N OPTIONAL USE. MAXIMUM ACADING PENALTY 50.10C 2. IF ACCESSIBLE ROUTE IS A RAISED SIDEWALK AREA, THEN RAMPS ARE LOADING $250 12" REQUIRED AT LOADING ZONE AREA. MAINTAIN MIN. 4' WIDE CONTINUOUS ZONE SIGN PASSAGE. MAXIMUM PENALTY 50.10C 3. VERTICAL CLEARANCE FOR VANS MUST BE GREATER THAN 98-INCHES. $28O 12"x9" 4. THIS DETAIL IS TO PROVIDE GENERAL GUIDANCE FOR PARKING LAYOUT AND O1'0 SEE ALSO DESIGN, REFER TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) SUPPLEMENTAL SIGN U.S DEPARTMENT OF TRANSPORTATION AND NORTH CAROUNA DEPARTMENT OF DETAIL TRANSPORTATION SUPPLEMENT AND NC BUILDING CODE FOR ADDITIONAL INFORMATION. ACCESSIBLE PARKING AND SIGNAGE STANDARDS NOTES: NOT TO SCA 2'-6" CURB AND GUTTER .............. CONTRACTION JOINT PLAN VIEW NOTES: 1. TRANSITION TO BE ALONG BACK OF CURB. CURB TRANSITION 2'-6" CURB AND GUTTER TO V-6" CURB AND GUTTER R7-8P DIMENSIONS (INCHES) A B C D E F G H J K L 12 6 3/8 3/8 1-1/2 1-1/2D 1/2 1D 2-1/2 4 1-1/2 ,INCREASE SPACING 50% D-FHWA (FEDERAL HIGHWAY ADMINISTRATION/USOOT) SERIES D LETTERS LEGEND AND BORDER - GREEN BACKGROUND - WHITE SUPPLEMENTAL VAN ACCESSIBLE SIGN (R7-8P) 1. REMOVE WIRE AND NYLON TWINE FROM BALL AND CANOPY. NOTES: 2. SOAK ROOT BALL AND PLANT PIT IMMEDIATELY AFTER INSTALLATION. 1. SCARIFY ROOT MASS OF 3. STAKING IS REQUIRED FOR ALL TREES IN R.O.W. OR UPON CONTAINERIZED PLANT MATERIAL. TYP. CQLLAF REQUEST OF ARBORIST. MIN. 2" HT. 2. INSTALL CONTAINERIZED PLANTS AT 4. REMOVE EXCESS SOIL FROM SITE AND DISPOSE OF IN A FINSHED GRADE 4" LAYER LEGAL MANNER. APPROVED' OF CH 3. TAMP PLANTING MIX FIRMLY 5. RESEED UNMULCHED, DISTURBED AREAS. AS PIT IS FILLED AROUND EACH PLANT BALL. - 3/4' NYLON STRAP 6" SUP KNOT VATH STOP KNOT. 4. OMIT COLLAR AROUND EACH SHRUB S' LARGER THAN TREE DIAMETER WHEN IRRIGATION SYSTEM IS PRESENT. "V" TRENCH AROUNC ROOT CROWN TO 5. ENTIRE PLANTING BE SOAK EACH PLANT BALL AND BE AT FINISH GRADE EEP MULCH AWAY FROM TRUNK 1" TO 2" PIT IMMEDIATELY AFTER EDGE OF INSTALLATION. PLANTING 4" HIGH / 8' MADE MAXIMUM BERM OUTSIDE OF ROOTBALL 4' MAXIMUM LAYER OF MULCH 3 - 1'x2'x18" WOOD STAKES WITH CENTERED 3/8' HOLE DRIVEN IN LINE KITH STRAP EQUALLY SPACED AROUND TREE FINISH GRADE REMOVE TYPICAL EXCESS SOIL FROM ROOT CROWN REMOVE TOP 1/3 BURLAP UNDISTURBED SOIL AND ANY NAILS/PINS, ETC. ROOT BALL DIA. 12' REMOVE TOP 1/3 OF WIRE VARIES BASKET WHERE PRESENT RAISE PIT BOTTOM TO SET ROOT CROWN AT THE CORRECT HEIGHT. FIRM SOIL UNDER ROOT BALL ALL TREES SHALL MEET AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1-2004) FOR EXAMPLE: CALIPER HEIGHT (RANGE) MAX. HEIGHT MIN. ROOT BALL DIA. MIN. ROOT BALL DEPTH 2" 12-14' 16, 24" 16" 3' 14-16' 18, 32" 21" TREE PLANTING (FOR SINGLE AND MULTI -STEM TREES) CROWN HEIGHT IN INCHES EQUALS MEDIAN BACKFILL AS SPECIFIED WIDTH IN FEET TO 12" MAX. FINAL GRADE 10" (EX.) f---- lo'(Ex.) -- -y EXISTING GRADE TYPICAL BED CROWNING NOT TO SCA SPACING VARIES SEE LANDSCAPE PLAN 1'� AND GUTTER .............. 1/8" GENERAL NOTES: 1. A GROOVE JOINT I" DEEP WITH 118" RADII SHALL BE REQUIRED /N THE CONCRETE .::. SIDEWALK AT 5' INTERVALS. ONE 112" EXPANSION JOINT WILL BE REQUIRED AT 45' INTERVALS NOT TO EXCEED 50' AND MATCHING EXPANSION/CONSTRUCT/ON JOINT /N ADJACENT CURB. A SEALED 1/2" EXPANSION JOINT WILL BE REQUIRED WHERE THE 4" it ; SIDEWALK JOINS ANY RIGID STRUCTURE. a ..' 1. 2. SIDEWALK AT DRIVEWAY ENTRANCES TO BE 6" THICK. 3. WIDTH OF SIDEWALK ON THOROUGHFARE STREETS SHALL BE A MINIMUM OF 6. WIDTH f'' -: a 'd • OF SIDEWALKS /N THE CENTRAL BUSINESS DISTRICT WILL BE DETERMINED BY THE CDOT. 4. WIDTH OF SIDEWALKS ON NON -THOROUGHFARE STREETS SHALL BE BASED ON TYPICAL STREET SECTION, A GROOVE JOINT IN SIDEWALK INTERSECTING STREETS/N/MUM OF 5. SIDEWALK TO BE POURED TO END OF RADIUS AT 1 /8" RADIUS 5. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3600 PSG IN 28 DAYS. 6. ZONING CONDITIONS MAY REQUIRE ADDITIONAL WIDTH SIDEWALKS WHICH SHALL SUPERSEDE THESE STANDARD DIMENSIONS SHOWN. 7. LIDS FOR JUNCTION BOXES AND UTILITY VAULTS SHALL BE NON-SKID AS SPECIFIED BY ENGINEER. 8. JOINT MATERIALS SHALL LIMIT SHRINK/SWE 1 /8" TO 1 Rf�$ULIS /N A MAX/MUM OF 1/4" FROM FL JOINT FILLER c 1/2" -1/2" EXPANSION JOINT 1.50% (2.00X MAX.) MPLE S/DEWALK CONSTRUCTION DIMENSIONS 4' 1.56% 5' 1 " 1.67% 6' 1-4" 1.56% 8' 1-4" 1.56% TRANSVERSE EXPANSION PROPOSED CURB do GUTTER JOINT IN SIDEWALK „ PROPOSED 4 CONCRETE SIDEWALK DETAILS SHOWING EXPANSION JOINTS IN CONCRETE SIDEWALK NOT TO SCALE NOT TO SCALE VAN SIGN R7 8P ACCESSIBLE RESERVED PARKING { f SIGN R7-8 r MAXIMUM PENALTY f SIGN 50.10C $ 250 FINISHED GRADE IIIII� NOT TO SCA INDER PLANT MEDIA EACH PLANT BALL TO MINIMIZE SETTLEMENT TYPICAL PLANTING BED DETAIL EQUAL BEONTING BETWEEN ALL PLANTS TYPICAL PLANTING BED PLAN SHRUB PLANTING BED TOP CONCRETE SIDEWALKS NOTE: SUPD IF THERE IS ONLY 12" i,\ry ONE PREQUIRED ACCESSIBLE LEMENrAL VAN SPARKING SPACE (MIBLE SIGN UST EBE VAN ACCESSIBLE) AND AT EACH ADDITIONAL REQUIRED VAN ACCESSIBLE SPACE (SEE SUPPLEMENTAL VAN ACCESSIBLE SIGN R7-8P DETAIL ( ) ) I + VAN SIGN R7-8P ACCESSIBLE ................................................. RESERVED MAXIMUM PARKING PENALTY SIGN R7.11 $250 3/8" (TYPICAL) /8" (TYPICAL) GS20-37.6 --. LEGEND AND BORDER - GREEN BACKGROUND - WHITE SIGN APPROVED FOR USE UNDER GENERAL STATUTE 20-37.6 THIS PENALTY SIGN IS REQUIRED TO ACCOMPANY ALL R7-8 PARKING SIGNS ERECTED AFTER D£CEMBER 31,1990 SUPPLEMENTAL ACCESSIBLE SIGN ?ALL DIAMETER SOIL LINE TOP 2" MAX/MUM OF SOIL COVERING ACCEPTABLE NATURAL S )WN MAXIMUM PENALTY I -SIGN 50.10C $ 250 (AS DELIVERED) (AS DELIVERED) NOTE: A ROOT FLARE EXCAVATION FOR ALL TREES SPECIFIED WILL BE DONE BY THE CITY ARBORIST TO ENSURE THAT TREES WERE NOT PLANTED/GROWN TOO DEEPLY AT SOURCE (NURSERY). LANDSCAPE CONTRACTOR SHALL HAVE SUPPLIER MARK GROUND LEVEL LINE ABOVE ROOT BALL. IF CITY ARBORIST DETERMINES THAT THERE IS EXCESSIVE SOIL OVER THE ROOT CROWN, THESE TREES WILL BE REJECTED. ROOT FLARE DEPTHS (TREE ROOT BALL CONDITION ON TREES FROM SUPPLIERS) FINISHED GRADE NOT TO SCA IETER METER SOIL V Z LL w Z (D Z LU to 0 N CV 1D 04 Z� Ld w O LZu � V � V � � LL Qj QZ OJ O OU 0� °c oa 0 C4 of PE SEAL: CARO ,,44�MAA�t'�♦ �� �• I SEAL 045345 i • "`•:� l A NE�9- C�l: 02/21/2023 N 1 Q J WJ Ix O W cle H r�a = W W z p O "I V =Z0 V W =ZW W kn V) O Lu 1 O V W i W 5: a 0 50 L W N Z 0 _N W N CNI o LL. O Lu Z ZLu L~u _ ,o 3w V Z�w w�= � w 0 V � TRENCH AND UTILITY NOTES 1. FOLLOW ALL OSHA GUIDELINES FOR SAFETY. FOR SHORING, FIELD DETERMINE SOIL CLASSIFICATION TYPE. 2. PERFORM ALL WORK TO NCDOT STANDARDS, 3. PROVIDE CONTINUOUS TRAFFIC FLOW IN AT LEAST ONE LANE DURING CONSTRUCTION. 4. PROVIDE TRAFFIC CONTROL IN ACCORDANCE WITH THE 'NORTH CAROLINA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES'. 5. PROVIDE NEAT SAWCUT EDGES WHEN PAVING IS REMOVED. PAVEMENT OPEN CUT SHALL BE 7 FT WIDE MINIMUM. 6. RESTORE AND REPAIR DAMAGED DRIVES, WALKS AND FIXTURES. 7. SEE TRENCH BACKFILL DETAIL FOR SOIL COMPACTION. 8. EACH DAY CLEAN UP AND KEEP STREETS FREE OF ALL DEBRIS EXCEPT AS APPROVED BY ENGINEER. 9. REMOVE ROCK IN ACCORDANCE WITH ALL SAFETY REGULATIONS AND COORDINATE BLASTING WITH ENGINEER 10. COORDINATE EXISTING FIBER OPTICAL CABLE CONFLICTS WITH UTILITY COMPANIES. 11. WHEN DIGGING BESIDE UTILITY POLES CONTACT THE UTILITY COMPANY FOR THEM TO STABILIZE POLE AND ADJUST GUY WIRE TO ACCOMMODATE NEW PIPE. 12. VERIFY LOCATION OF UTILITIES. 'NC ONE CALL CENTER' '811' OR (800)632-4949 13. UTILITY REPAIR PHONE NUMBERS IN DAVIE COUNTY ARE: DUKE ENERGY (W-S) (336)917-2556 ENERGY UNITED ELECTRIC CORP. (336)751-2136 PIEDMONT NATURAL GAS (336)726-7761 AT&T FIBER (800)924-9420 CENTURY LINK (336)526-3294 QWEST COMMUNICATIONS (336)210-4402 SPECTRUM (CHARTER) (336)785-3390 YADKIN VALLEY TELEPHONE (336)463-5074 WAKE FOREST UNIV MEDICAL (336)716-4657 MOCKSVILLE WATER (336)751-2519 DAVIE COUNTY WATER (336)753-6090 . WATER MAIN GENERAL NOTES: 1. STANDARD WATER MAIN SHALL BE DR14 305 PSI C900 PVC WITH DUCTILE IRON FITTINGS OR CEMENT LINED ASPHALTIC COATED DUCTILE IRON FOR PUSH CLASS 50 AND MJ CLASS 51, 2. NCDENR PER SECTION .0904 REQUIRES PVC WATER MAIN TO HAVE 30" MINIMUM GROUND COVER. 3. NCDOT REQUIRES 36" MINIMUM COVER IN ROADWAY AREA. 4. DUCTILE IRON PIPE SHALL BE USED IF WATER MAIN DOES NOT MEET OR EXCEED THE FOLLOWING SEPARATION: A. 18" VERTICAL ABOVE CROSSING STORM OR SANITARY SEWER PIPE. B. 10' HORIZONTAL SEPARATION FROM PARALLEL SEWER PIPE. C. 10' HORIZONTAL FROM STREAM, LAKE OR WATER IMPOUNDMENTS. 5. CENTER ONE 20' SECTION OF DUCTILE IRON PIPE AT ALL CULVERT PIPE CROSSINGS. MAINTAIN 18" VERTICAL CLEARANCE BETWEEN NEW WATER LINE AND EXISTING PIPES. 6. PROVIDE A TRACER WIRE ABOVE THE PIPE. THE TRACER WIRE SHALL A. BE SOLID NO.12 COPPER WITH 30 MILS BLUE HDPE INSULATION. B. BE FASTENED AT 10 FT INTERVALS TO THE PIPE WITH ZIP TIES. C. HAVE CONTINUOUS ELECTRICAL CONNECTION. 7. PROVIDE A CONTINUOUS WARNING TAPE 12" ABOVE THE PIPE. 8. DISINFECT, FLUSH AND PRESSURE TEST WATER MAIN UNDER UTILITY INSPECTION AS FOLLOWS: A. DISINFECT SYSTEM BY MAINTAINING DISINFECTANT AT 50 PPM IN SYSTEMS FOR 24 HOURS. B.FLUSH SYSTEM THOROUGHLY TO 0 PPM, TAKE SAMPLE FROM FLUSHED SYSTEM AND SEND TO LAB FOR BACTERIOLOGICAL TEST. C. PRESSURE TEST THE SYSTEM AT 175 PSI OR GREATER. MAINTAIN FOR AT LEAST 3 HOURS. ADD SUFFICIENT WATER TO BRING BACK TO STARTING PRESSURE. WATER ADDED SHALL NOT EXCEED THE GPH/1000 FT OF LINE TESTED PER THE TABLE. PRESSURE TESTING MUST BE OBSERVED BY THE A UTILITY REPRESENTATIVE AND DOCUMENTED IN THE CONSTRUCTION RECORDS BY THE CONTRACTOR. Allowable Leakage D Ga111000ft Water Added H Pipe Dia. in. 201 pipe galthr Gals for 3 hrs Gals D 8 H in .0034 x D�H) 4 0.33 099 6 0.5 1.50 D & H ft 6.876 x DI(H) a 0.67 2.01 12 1 3.00-1 SUPPLEMENTAL SPECIFICATIONS THE FOLLOWING SPECIFICATIONS SHALL APPLY TO THE DETAILS PROVIDED BY DAVIE COUNTY. 1. WATER DISTRIBUTION MATERIALS MUST BE MANUFACTURED TO AND MEET THE APPROPRIATE AWWA STANDARDS, SECTION C OR ANSI/NSF STANDARD 61, DRINKING WATER SYSTEM COMPONENTS. 2. PVC PIPES AND FITTINGS SHALL MEET THE LATEST AWWA C900 STANDARDS. 3. DUCTILE IRON PIPE & APPURTENANCES SHALL MEET, BASED ON DEVICE, THE LATEST AWWA C100 SERIES STANDARDS. 4. FIRE HYDRANTS SHALL MEET THE LATEST AWWA C502 STANDARDS. 5. GATE VALVES SHALL MEET THE LATEST AWWA C509 STANDARDS. 6. METERS MUST SHALL THE LATEST AWWA C700 STANDARDS. 7. SERVICE CONNECTIONS SHALL MEET THE LATEST AWWA C800 STANDARDS. 8. INSTALLATION OF PVC PIPES AND FITTINGS SHALL MEET THE LATEST AWWA C605 STANDARDS. 9. INSTALLATION OF DUCTILE IRON PIPE AND APPURTENANCES SHALL MEET THE LATEST AWWA C600 STANDARDS. 10. NEW WATER MAINS SHALL BE DISINFECTED AS OUTLINED IN RULE _1001 AND RULE .1003. 11. HYDROSTATIC PRESSURE TESTING SHALL BE COMPLETED ON ANY PRESSURE PIPES CARRYING LIQUIDS AND BE COMPLETED PER THE LATEST AWWA C600 OR AWWA C605 STANDARDS. 12. AFTER DISINFECTION, WATER STORAGE OR DISTRIBUTION FACILITIES SHALL NOT BE PLACED INTO SERVICE UNTIL BACTERIOLOGICAL TEST RESULTS OF REPRESENTATIVE WATER SAMPLES SHALL BE ANALYZED BY A STATE CERTIFIED LABORATORY PER RULE .1001. U Z Ld f- V1 c W_ J n U J m d Z> O� Ui W_` > .j Q i 0 U) Ld O 0 F_ O Z J U Q w fY IZ W (n L7 Q H- Z W a2 :2 W 0 a� 68 FN c2 • 00 r EMBEDMENT SOIL MATERIAL CLASSIFICATIONS CLASS TYPEI DESCRIPTION OF SOIL MATERIAL I * MANUFACTURED ANGULAR, GRANULAR MATERIAL, '-, TO 11-2 INCHES (6 TO 40MM) SIZE, INCLUDING MATERIALS HAVING REGIONAL SIGNIFICANCE SUCH AS CRUSHED STONE OR ROCK, BROKEN CORAL, CRUSHED SLAG, CINDERS OR CRUSHED SHELLS. GW WELL -GRADED GRAVELS AND GRAVEL -SAND MIXTURES, LITTLE OR NO FINES. 50% OR MORE RETAINED ON NO. 4 SIEVE. MORE THAN 95% RETAINED ON NO. 200 SIEVE. CLEAN. II ** POORLY GRADED GRAVELS AND GRAVEL -SAND MIXTURES, LITTLE OR NO FINES. 50% OR MORE RETAINED ON NO. 4 SIEVE. MORE THAN 95% RETAINED ON NO. 200 SIEVE. CLEAN. GP WELL -GRADED SANDS AND GRAVELLY SANDS, LITTLE OR NO FINES. MORE THAN 50% PASSES NO.4 SIEVE. MORE THAN 95% RETAINED ON SW NO, 200 SIEVE. CLEAN. POORLY GRADED SANDS AND GRAVELLY SANDS, LITTLE OR NO FINES. MORE THAN 50% PASSES NO. 4 SIEVE. MORE THAN 95% RETAINED ON SP NO. 20D SIEVE. CLEAN. GM SILTY GRAVELS, GRAVEL -SAND -SILT MIXTURES, 50% OR MORE RETAINED ON NO. 4 SIEVE. MORE THAN 50% RETAINED ON NO. 200 SIEVE. III ** CLAYEY GRAVELS, GRAVEL -SAND -CLAY MIXTURES. 50% OR MORE RETAINED ON NO. 4 SIEVE. MORE 50% RETAINED ON NO. 200 SIEVE. GC SM SILTY SANDS, SAND -SILT MIXTURES. MORE THAN 50% PASSES NO.4 SIEVE. MORE THAN 50% RETAINED ON NO. 200 SIEVE. CLAYEY SANDS, SAND -CLAY MIXTURES. MORE THAN 50% PASSED NO. 4 SIEVE, MORE THAN 50% RETAINED ON NO. 200 SIEVE. Sc ME INORGANIC SILTS, VERY FINE SANDS, ROCK FLOUR, SILTY OR CLAYEY FINE SANDS. LIQUID LIMIT 50% OR LESS. 50% OR MORE PASSES NO. 200 SIEVE. IV INORGANIC CLAYS OF LOW TO MEDIUM PLASTICITY, GRAVELLY CLAYS, SANDY CLAYS, SILTY CLAYS, LEAN CLAYS. LIQUID LIMIT 50% OR LESS. 50% OR CL MORE PASSES NO. 200 SIEVE. INORGANIC SILTS, MICACEOUS OR DIATOMACEOUS FINE SANDS OR SILTS, ELASTIC SILTS. LIQUID LIMIT GREATER THAN 50%. 50% OR MORE PASSES MH NO. 200 SIEVE. INORGANIC CLAYS OF HIGH PLASTICITY, FAT CLAYS, LIQUID LIMIT GREATER CH THAN 50%. 50% OR PASSES NO. 200 SIEVE. OL ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW PLASTICITY. LIQUID LIMIT 50% OR LESS. 50% OR MORE PASSES NO. 200 SIEVE. V ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY. LIQUID LIMIT GREATER THAN 50%. 507. OR MORE PASSES NO. 200 SIEVE. OH PT PEAT, MUCK AND OTHER HIGHLY ORGANIC SOILS. * SOILS DEFINED AS CLASS 1 MATERIALS ARE NOT DEFINED IN ASTM D2487. ** IN ACCORDANCE WITH ASTM D2487, LESS THAN 5% PASS NO. 200 SIEVE. *** IN ACCORDANCE WITH ASTM D2487, LESS THAN 12% PASS NO. 200 SIEVE. SOILS WITH 5% TO 12% PASS NO. 200 SIEVE FALL IN BORDERLINE CLASSIFICATION, E.G., GP -GC. 3' fix? ROMAC STYLE THRUST FOR 6" MAIN SST (SS TAPPING BLOCK fi" MJxFLG SLEEVE) ON MAIN GATE VALVE a. THRUST BLOCK II I. n u V NOTE: BEND ALL FITINGS SHALL PLAN BE MJ RESTRAINTED. VALVE BOX COLLAR/PAD SECTION SEE DTL 2.31 o � oho Oc 6" MJxFLG z GATE VALVE MTL VALVE BOX THRUST 6x? ROMAC STYLE BLOCK SST (SS TAPPING SLEEVE) ON MAIN • :. - THRUST BLOCK s EDGE OF 45° -' - - PAVEMENT BEND SEE PLAN NEW TAPPING TEE, VALVE & BEND ON EXISTING MAIN 24 W-TEE-TAP-VAL+BND f- (n Z U) Ld Q -1 0 U W m Ld of N , a �o0 V) o W_ °o J to r� U J m 2 r Zo Ou U� W0 a� 0 LJ Z J Q Q > U Z_ LLLJ ~ H x c� Z_ Z 11 O Q C) ~ Z 3: W Ldm \n/ PIPE CONSTRUCTION NOTES: 1. FITTINGS SHALL BE CLASS 51 DUCTILE IRON MECHANICAL JOINTS WITH AN APPROPRIATE TRANSITION GASKET TO PVC WHERE APPLICABLE. 2. WHEN CONNECTING DUCTILE IRON PIPE TO PVC PIPE, USE AN APPROPRIATE TRANSITION GASKETS TO PVC BELL END AND A SLEEVE WITH APPROPRIATE GASKETS AT THE PLAIN END. 3. DEFLECTION AT THE JOINTS SHALL NOT EXCEED 14" FOR LENGTH OF PIPE OR 80% OF MANUFACTURER'S RECOMMENDATION, WHICHEVER IS LESS, 4. CASING PIPES SHALL BE BORED UNLESS OTHERWISE NOTED. SEE CASING PIPE SPACERS DETAIL. 5. FOR JURISDICTIONAL DRAINAGE CROSSINGS, USE PIPE CROSSING STREAM INSTALLATION DETAIL AND JURISDICTIONAL STREAM CROSSING DETAIL 6. FOR NON -JURISDICTIONAL DRAINAGE CROSSING, USE PIPE CROSSING STREAM INSTALLATION DETAIL AND DITCH CROSSING DETAIL. 7. PROVIDE JOINT RESTRAINT AT ALL BENDS, TEES AND CAPS. JOINT RESTRAINT SHALL BE A COMBINATION OF CONCRETE THRUST BLOCKING ACCORDING TO DETAILS SHOWN AND MECHANICAL JOINT RESTRAINT AS APPROVED BY THE ENGINEER. MECHANICAL JOINT RESTRAINTS SHALL BE PLACED AT MULTIPLE LOCATIONS ON EACH SIDE OF FITTINGS ACCORDING TO MANUFACTURER'S RECOMMENDATION. 8. MECHANICAL JOINT RESTRAINT SHALL BE A. FOR DI PIPE TO MJ: CLOW MJ FIELD LOK, MEGLUG #1100, MIDCO #4 RESTRAINT, SMITH-BLAIR #981 OR STAR PIPE #3000, #3000S. B. FOR C900 PIPE TO MJ: CLOW MJ FIELD ECK, MEGLUG #200OPV, MIDCO #4 RESTRAINT, SMITH-BLAIR #981 OR STAR PIPE #4000, #1000C, #1200. C. FOR SDR-21 PIPE TO MJ: MEGLUG #20OOPV MIDCO #4 RESTRAINT, SMITH-BLAIR #981 OR STAR PIPE #4000, #1000S. NOT APPLICABLE TO NEW PROJECTS. D. FOR PIPE BELL/SPIGOT RESTRAINT: SMITH-BLAIR #932, STAR PIPE #410OP, #1100. 8. CONCRETE THRUST BLOCK RESTRAINT AND SUBSURFACE SUPPORT SHALL BE 4000 PSI CLASS 'B' CONCRETE WITH 5% AIR ENTRAINMENT, 0.45 WATER CEMENT RATIO AND PLACED AT A SLUMP NO GREATER THAN 3". 9. CONTRACTOR SHALL SUBMIT TO ENGINEER THE MODEL, MANUFACTURER AND TYPICAL PLACEMENT OF RESTRAINT SYSTEM TO BE USED ON PROJECT. (DXX �Q'( IX tN� -- EXIST. OR NEW O \ O 2 V11 01 z 4 6" PIPE 1 Q) 1 Z I 2N O -------------- 2'-8" MIN. O BEYOND (/ STEEL CASING SECTION A -A SECTION B-B PLAN m O KEYNOTES: STEEL CASING PIPE O (DGATE ROMAC SST TAPPING SLEEVE/TEE, :nl VALVE & VALVE BOX: SEE ---------- PLAN FOR SIZE I I I - O 90' BEND MJ RESTRAINED ' OTWO(2) 3/4"0 S5 THREADED RODS WITH SS NUTS TYP. EA. SPOOL PIECE 1 O VALVE BOX & COLLAR/PAD, SEE DTL O OnQ 2.31 ° NOTE: ALL FITTINGS SHALL BE MJ RESTRAINED. A 4 m A STD, ' U' CONNECTION 24 W-UCON NEW ASPHALT _NCH TOP WI❑ In w J F- 7) EX. ASPHALT PAVEMENT TRENCH WIDTH NEW EX. GROUND GROUND I -I III �\ II I -I \ 95% STD. I -I I 1� PROCTOR % I I- MIRAFI 40OX N 1 FILTER FABRIC AS DIRECTED I I I I I I I i} O I I OPEN OVERNIGHT. I I OUTSIDE I � m INSIDE PAVEMENT AREA m PAVEMENT AREA } KEYNOTES FOR TRENCH BACKFILL ~ Z ° CONTRACTOR SHALL COMPLY WITH ALL OSHA REGULATIONS FOR TRENCH SHORING AND O2 PROVIDE CLASS I, II, III OR IV SOIL BACKFILL. O C_' SLOPING. A "COMPETENT PERSON" AS DEFINED COMPACT SOIL IN 6" LAYERS TO 95% (� BY 'OSHA' SHALL BE ON SITE AT ALL TIMES STANDARD PROCTOR DENSITY IN ALL PAVED w 'o WHEN ANY WORKER IS IN A TRENCH. AND SHOULDER AREAS AND TO 90% STANDARD w PROCTOR DENSITY FOR ALL OTHER AREAS. Q v i0 SEE EMBEDMENT SOIL MATERIAL CLASSIFICATIONS TABLE FOR SOIL CLASSES. 2R PROVIDE FLOWABLE FILL FOR HEAVY DUTY ADD WATER TO EACH LAYER AS NEEDED OR DIRECTED FOR COMPACTION AND ASPHALT REPAIR, SEE PAVING DESIGN TABLE FOR SUBGRADE. MECHANICALLY TAMP THOROUGHLY. O3 PROVIDE CLASS I, II, ill OR IV SOIL BACKFILL. KEYNOTE FOR BEDDING PIPE COMPACT SOIL IN 6" LAYERS TO 100% O PROVIDE CLASS I, II, III SOIL FOR BEDDING. STANDARD PROCTOR DENSITY FOR TOP 1 FT � DIG BELL HOLES IN ACCORDANCE WITH OF SUBGRADE. Z MANUFACTURERS RECOMMENDATIONS. O4 SEE PAVING DESIGN TABLE FOR PAVING. z A. PLACE PIPE ON COMPETENT 501E BOTTOM. O SEE PAVING DESIGN TABLE FOR SURFACE COURSE. 0 B. FOR UDhL COMPETENT TRENCH BOTTOM, U PLACE PIPE ON 12" BEDDING OVER MIRAFI 400X FILTER FABRIC AS DIRECTED BY TRENCH BACKFILL � ENGINEER. 32 TRNCHFLL-W SHEET: 1 OF 1 05/20/2o TRENCH BACKFILL FOR WATER GSB 1 0 DAVIE COUNTY PUBLIC UTILITIES uz • daviecount C. ov 336 753-5090 n '■7 101 C IN o� 8 4) 0o0 W Ln U m COVER FITTING WITH PLASTIC BEFORE PLACING CONCRETE �3D 8" MIN. -31D8" MIN. B A o m �A A D/4 MIN. m G Q i_� m o SECTION A -A HORIZONTAL n_ r I- Z> O C' U� w Qo SHEET: i OF 1 05/20/20 1. 09 GSB A B ELEVATION ommmmmmm SECTION B-B COMPRESSION THRUST VERTICAL BLOCKS AT BENDS THRBK3 COMPRESSION THRUST BLOCKS AT BENDS DAVIE COUNTY PUBLIC UTILITIES a,..ae....._. .nlr ,.,.,. lzzalaz_annn 5Y4" FIRE HYDRANT, YELLOW W/ 5" \ I ST/ORZ CONNECTION VALVE BOX EDGE OF COLLAR/PAD PAVEMENT cv � SEE DTL 231 GROUND I MTL VALVE BOX 77 1 � 6" DI 6" MJ GATE VALVE t ALPHA RESTRAINED RJ PIPE 6" ATTACHMENT I+ TEE ON MAIN IooQ o°a° o o°;. 6 • e THRUST b - ' ° BLOCK I , f °gyp .. THRUST 3 CF MIN. BLOCK WASHED STONE 3 (AS REQUIRED) V-1.5" 3' MIN. 31u. rim DAVIE COUNTY STD W-FHYD-TEE DC SHEET: i OF 1 05/24/21 STD. FIRE HYDRANT GSB DAVIE COUNTY PUBLIC UTILITIES 2.07 W/ H YD . TEE daviecountAC.aov (336)753-6090 CONCRETE DIMENSIONS MIN DIM FOR PIPE DIA(D)O DIM 2-4" 6" 8" 10" 12" 16" A 19" 19" 24" 28" 35" 44" B 15" 15" 18" 21 " 25" 33" C 6„ 6„ 8„ 8„ 10„ 12„ COVER FITTING WITH PLASTIC BEFORE PLACING CONCRETE A A jo < ,e m SECTION A -A CAP THRUST BLOCK THRBKI CONCRETE DIMENSIONS MIN DIM FOR PIPE DIA(D)4 DIM 2-4" 6" 8" 10" 12" 16" A 6" 6" 8" 12" 12" 16" B 8" 8" 10" 12" 15" 20" C 8" 9 9" 10" 12" 14" E 6" 6" 8" 8" 8" 10" COVER FITTING WITH PLASTIC BEFORE PLACING CONCRETE Z PLAN The SECTION A -A TEE THRUST BLOCK THRBK2 SHEET: i of , 05/20/20 CAP & TEE THRUST BLOCKS GSB DAVIE COUNTY PUBLIC UTILITIES 1.08 // / . 0j��y rinvirrnllnhA r,, nnv (.S.1fi)753-f;Dgn Z 5Y4" FIRE HYDRANT, J YELLOW W/ 5" \I STORZ CONNECTION o in I 0 1 +1 l N I 4// GROUND z 6" DI 1 ALPHA RESTRAIN i 1 PIPE look o°Ja o°©RJ VALVE BOX EDGE OF COLLAR/PAD PAVEMENT SEE DTL 2.31 MTL VALVE BOX 6" MJ GATE VALVE 6" MJ TEE ON MAIN - THRUST I �A BLOCK 4 I e THRUST 3 CF MIN. 3/4" 0 SS THREADED BLOCK I WASHED STONE RODS WITH SS NUTS (BOTH SIDES) 1' 3" (AS REQUIRED) 2'-6" MIN. STD. FIRE HYDRANT DAVIE COUNTY STD 24 W-FHYD2 DC SHEET 1 0 0s/24/21 STD. FIRE HYDRANT 2.06 GSB 3' MIN. DAVIE COUNTY PUBLIC UTILITIES leCD Z Lu w Z C� Z Lu to Q N NN � (N Z� Ld w I- 2 OW V o� V c .0) n Q a� OZ o ALu O o cle = U OL2 � 0 oa Z [N Z oI PE SEAL: A.. Y\ CARO '0 SEAL 1. 045345 •G I NE��••• �% BUGF #11 least* on 02/21/2023 N 0 In ca I Q J Wtin J LU Cie O H 00 �a V a 1-- r = W W a�z p O L1 Va =Z0 V W =ZW Lu O Lu 1 O V = Lu i W a� a 0 0 � G W se De 0 3 V J m Oe W fi- n W _N W Cie CV N Z N O\ t!f r >r W f� N CV 0 m�3 a LL J ,w0CNI LL wmm o Lu0 ZZC) Lu Lu 3 V)Se ~ z Lu w W V CG d NOTES: 1. INSTALL SADDLE AND VALVE PRIOR TO DISINFECTING MAIN LINE. VALVE BOX & COLLAR/PAD GROUND SEE DTL 2.31 x ?X2 DUCTILE m 2" GATE VALVE TAPPING SADDLE J OPERATING NUT W/ 2 BALES, Q SMITH-BLAIR STYLE 313 p0U COMP MAIN L 2" TYPE LINE(?) 2" BRASS 'K' COPPER NIPPLE TYP. 2" WATER CONNECTION 24 W-2WTR CON DC GRAVITY SEWER GENERAL NOTES: 1. STANDARD GRAVITY SANITARY SEWER SHALL BE SDR-35 PVC WHERE APPROPRIATE. 2. DUCTILE IRON PIPE SHALL BE USED IF SANITARY SEWER DOES NOT MEET OR EXCEED THE FOLLOWING SEPARATION: A " MINIM V A. 36 M GROUND U G U D COVER E B. 24" VERTICAL FROM STORM SEWER PIPE (CROSSING OR PARALLEL) C. 18" VERTICAL UNDER OR 10' HORIZONTAL FROM WATER MAIN. D. 10' HORIZONTAL FROM STREAM, LAKE OR WATER IMPOUNDMENTS. COMPLY WITH 15A NCAC 02T.0305 (f). 3. CENTER ONE 20' SECTION OF PIPE AT ALL PIPE CROSSINGS. 4. WHEN CONNECTING DUCTILE IRON PIPE TO PVC PIPE, USE AN APPROPRIATE TRANSITION GASKETS TO PVC BELL END AND A SLEEVE WITH APPROPRIATE GASKETS AT THE PLAIN END. 5. WATERTIGHT AND SEALED FRAME AND COVERS ARE REQUIRED WHERE THE RIM ELEVATION IS LESS THAN 1 FOOT ABOVE THE 100 YEAR FLOOD ELEVATION OR AS INDICATED ON THE APPROVED PROFILE. U.S. FOUNDRY & MANUFACTURING CORPORATION MODEL #USF 668-KL-BWT. 6. WHERE ANTI -SEEP COLLARS ARE REQUIRED, THEY SHALL BE PLACED A MINIMUM OF 8 FT FROM MANHOLES. 7. FOR MANHOLES IN ROAD RIGHT-OF-WAY, SET FRAME AND COVER TO SHOULDER GRADE IN A COMPACTED CONDITION. 8. OUTSIDE ROAD RIGHT-OF-WAY PROVIDE A PERMANENT EASEMENT OF 30' FOR GRAVITY SEWER AND 25' FOR SEWER FORCEMAIN WITH AN ADDITIONAL 10' CONSTRUCTION EASEMENT. 9. SEWER SERVICE SCH 40 PVC PIPE AND FITTINGS SHALL HAVE FULLY PRIMED MEDIUM VISCOSITY GLUED JOINTS. 10. ALL SEWER CONNECTIONS THAT CROSS UNDER AN EXISTING ROAD SHALL BE BORED, 2' DIA. t., MIN. 12' DI I INTO TEE N 4' DIA. 8x8 TEE If REMOVEABLE 8" PLUG cn a18"L NIPPLE IN FLEXIBLE z SLEEVE _ o Z O W r7 m l C m 4" MIN. + 1 cnNc. �. +1 '" COLLAR. co = v '= 6" \L COMPACTED CRUSHED STONE MIN, GENERAL NOTES: 1. SEE STANDARD PRECAST SANITARY SEWER MANHOLE FOR ADDITIONAL MANHOLE DETAILS. 2. ALL PIPE AND FITTINGS SHALL BE DUCTILE IRON. PROVIDE MINIMUM OF 12 FT OF DUCTILE IRON PIPE UPSTREAM OF TEE. 3. CONCRETE ENCASEMENT FOR OUTSIDE DROP MANHOLES SHALL BE STANDARD SUBSURFACE SUPPORT CONCRETE AS SPECIFIED IN NOTES FOR TRENCH AND PIPING. OUTSIDE DROP PRECAST MANHOLE REF. NCDOT RSD 840.67 32 840-67oD LO o wg �I J n M UY J m D 0 z> o D v Ou U wo a > af Ld Z I— < C) U W N Z Z �O U W J F- U J m D 0- H z O U Ld a a Q' V? Ww F- W O uJ Z Q W IY Z 0W C.0 o� O 00 w w ' J Page 49 of 63 Q _ a- 0 V) w H J F- U J m D o_ z O U l,J > a a W J a_ 0 0ry 0 Q W m C) I__ f� C!1 �- a U OW Q' Q_ 5 9 8 I- III SERVICE =1 111= LINE MAIN X2/ 3 LINE 1\,- O 4 6 7 NOTE: INSTALL SADDLE AND STOP PRIOR TO DISINFECTING MAIN LINE. MATERIAL KEYNOTES O1 TAP: SMITH-BLAIR STYLE 313 1" CC THREADS O CORP. STOP: MUELLER H15005 �3 PIPE: 1" 200 PSI SDR-9 CTS PE (DFITTING: MUELLER H14230 O METER YOKE: MUELLER 1" B-2404R-2AN 10" HGT. WITH 300 PSI BALL ANGLE VALVE O FITTING: MUELLER H14222 O7 OUTLET PIPE: TYPE "K" COPPER PIPE O METER BOX: 13X24X15 PLASTIC BOX & LID EQUAL TO 'NDS' PRO 125BCDWB SET TO GRADE ON 6 BRICKS. O METER: MUELLER HERSEY 452B ME8 (MI.NET NODE AMR) IN GALS. 1 " WATER SERVICE DAVIE COUNTY STD 24 W-MTR1 DC 300 GRAVITY SEWER TESTING NOTES: 1. FOR THE GRAVITY PIPE, PERFORM STRAIGHTNESS, LEAKAGE AND DEFLECTION TEST ON THE SEWER PIPE IN ACCORDANCE WITH TO 'NCDEQ' REGULATIONS. A. LEAKAGE TEST: USE NO MORE THAN 4 PSI AIR PRESSURE. OBSERVE AND RECORD THE TIME FOR A 1 PSI DROP. THE TIME SHALL NOT EXCEED THE VALUE IN THE AIR LEAKAGE TABLE: MINIMUM TIME (MINUTES -SECONDS) ALLOWED FOR PRESSURE DROP FROM 3.5 TO 2.5 PSIG FOR VARIOUS PIPE LENGTHS AND DIAMETER. B. DEFLECTION TEST SHALL EASILY PASS A STANDARD MANDREL FOR THE INDICATED NOMINAL PIPE SIZE WITH ALLOWANCE FOR NO MORE THAN 4% DEFLECTION. C. TESTS MUST BE OBSERVED BY THE A UTILITY REPRESENTATIVE AND DOCUMENTED IN THE CONSTRUCTION RECORDS BY THE CONTRACTOR, 2. FOR THE MANHOLES, PERFORM VACUUM TEST ON SEWER MANHOLES IN ACCORDANCE WITH TO 'NCDEQ' REGULATIONS. A. TEMPORARILY PLUG ALL PIPES ENTERING THE MANHOLE AND PLACE THE TEST HEAD INSIDE THE RIM OF THE CAST IRON FRAME AND INFLATE. B. THE PRESSURE GAUGE SHALL BE LIQUID FILLED, HAVING A 3.5 INCH DIAMETER FACE WITH A READING FROM ZERO TO THIRTY INCHES OF MERCURY C. A VACUUM OF AT LEAST TEN INCHES OF MERCURY (10" Hg) SHALL BE DRAWN ON THE MANHOLE. D. SHUT THE VALVE OF THE VACUUM LINE TO THE MANHOLE OFF AND DISCONNECT THE VACUUM LINE FROM THE PUMP. E.THE MANHOLE SHALL BE CONSIDERED TO PASS THE VACUUM TEST IF THE VACUUM READING DOES NOT DROP MORE THAN 1" Hg (i.e. FROM 10" Hg TO 9" Hg) DURING THE MINIMUM TEST TIMES FROM THE TABLE BELOW. F. IF A MANHOLE FAILS THE VACUUM TEST, THE MANHOLE SURFACES SHALL BE PROPERLY REPAIRED. G. THIS PROCESS SHALL CONTINUE UNTIL A SATISFACTORY TEST IS OBTAINED. H.ALL TEMPORARY PLUGS SHALL BE REMOVED AFTER EACH TEST. I. TESTS MUST BE OBSERVED BY THE A UTILITY REPRESENTATIVE AND DOCUMENTED IN THE CONSTRUCTION RECORDS BY THE CONTRACTOR. MINMIMUM VACUUM TEST TIMES MH Depth MH DIAMETERS 1t b' 5' 1 W 15 or less 50" 1' 05.. 1 1' 20" 15.01 to 30 1' 30" 1' 45" 7 10" FORCEMAIN GENERAL NOTES: V) w I-- U J In D 0- z O U W a 0 W U ix W L0 x W I- Wo J rL �3 U J m D D_ r I- Zo O U.. C W o a� 0 U) W H O Z 0 Z_ H- lJ) W H W LLI 0 I-- a U 0 N w w Page 50 of 63 ¢ _ a- 0 1. STANDARD SEWER FORCEMAIN SHALL BE PVC C-900 OR FUSIBLE HDPE WHERE APPROVED. 2. DUCTILE IRON PIPE SHALL BE USED IF SANITARY SEWER DOES NOT MEET OR EXCEED THE FOLLOWING SEPARATION: A. 36" MINIMUM GROUND COVER B. 24" VERTICAL FROM STORM SEWER PIPE (CROSSING OR PARALLEL) C. 18" VERTICAL UNDER OR 10' HORIZONTAL FROM WATER MAIN. D. 10' HORIZONTAL FROM STREAM, LAKE OR WATER IMPOUNDMENTS. COMPLY WITH 15A NCAC 02T.0305 (f). 2. CENTER ONE 20' SECTION OF DUCTILE IRON PIPE AT ALL CROSSINGS. 3, FOR AIR VALVES IN ROAD RIGHT-OF-WAY, SET MANHOLE FRAME AND COVER TO SHOULDER GRADE WITH SURROUNDING SOIL OR STONE IN A COMPACTED CONDITION. 4. PRESSURE TEST THE SYSTEM AT 150 PSI OR GREATER. MAINTAIN FOR AT LEAST THREE HOURS. ADD SUFFICIENT WATER TO BRING BACK TO STARTING PRESSURE AFTER THREE HOURS. WATER ADDED SHALL NOT EXCEED THE GPH/1000 FT OF LINE TESTED PER THE FOLLOWING TABLE. PRESSURE TESTING MUST BE OBSERVED BY THE A UTILITY REPRESENTATIVE AND DOCUMENTED IN THE CONSTRUCTION RECORDS BY THE CONTRACTOR. Allowable Leakage Ga111000ft Water Added Pipe Dia. in. 20'L pipe gallhr Gals for 3 hrs Gals D & H in .0034 x DI(H) 4 0.33 0.99 6 0.5 1.50 D&H ft 5.875 x D(H) 8 0.67 2.01 12 1 3.00 1 V) w H J H Z) U J m a- I- z 0 U Ld a 0 Z QLd � LLI U Z rZ 0 W LL a W W z WLd 0 (A 2" RPZ NOTES: 1. BACKFLOW PREVENTER LOCATION REQUIRES PRIOR APPROVAL, MUST BE ON THE PROPERTY SIDE AND MUST NOT OBSTRUCT SIGHT DISTANCE. PROVIDE 36" CLEAR OUTSIDE OF ENCLOSURE ON ALL SIDES. 2. SLAB SHALL BE 3000 PSI CONCRETE, 51 "LONG x 25"WIDE x 4"THICK WITH 6x6-W1.4XW1.4 WWF OVER 3" COMPACTED CRUSHED STONE. 3. REDUCED PRESSURE BACKFLOW PREVENTER SHALL BE A 'WATTS' 2" 909M1-0T (OR EQUAL). SHUT-OFF VALVES SHALL BE FULL PORT, LINE SIZE AND 1 /4 TURN BRONZE UNION BALL VALVES. NO BY-PASS WILL BE ACCEPTED. 4. PIPE RISERS AND BENDS SHALL BE 'STICK' TYPE 'K' COPPER OR BRASS FOR A MINIMUM OF 5 FT EACH SIDE OF VALVES. 5. THE ABOVE GROUND ENCLOSURE SHALL BE 'HOT -BOX' #IF013039028 (OR EQUAL) FIBERGLASS, INSULATED TO R8, HAVE A FLIP -TOP ACCESS, LOCKABLE SS HASP & (2)TWO DRAIN PORTS AT GRADE. COLOR BEIGE. 6. PROVIDE GFI RECEPTACLE MOUNTED 21" MINIMUM ABOVE THE SLAB. 7. THE ENCLOSURE SHALL BE HEATED WITH A 90W, 120V, 18 FT LONG HEAT TRACE CABLE. SEE NOTE 5 FRAME AND COVER, SEE NOTE 4 MAX. 2-5" RISER RINGS OR 8" OF BRICK ONLY FOR TYPE 1 RING AND COVER 2' DIA.\\ ECCENTRIC TOP SHALL BE USED ro I 6" WIDE EXTERIOR WATERPROOFING V WRAP AT EACH JOINT STEPS SHALL BE 1/2"0 60 KSI DIA. STEEL ENCASED IN POLYPROPYLENE. SEE GENERAL NOTE 2. 4' V) w < ri BENCH SHALL BE BRICK & MORTAR � OR APPROVED PRECAST WITH 2"/FT. SLOPE TOWARD EDGE AND TOP OF EDGE AS HIGH AS TOP OF PIPE 3"RA EDGE o INVERT IS TOP OF PRECAST BASE MIN. 6" ' ' N I 12" MIN. EXTENDED BASE, SEE NOTE 7 D s------------ " COMPACTED CRUSHED STONE GENERAL NOTES: 1. MANHOLE COMPONENTS SHALL MEET LATEST REVISION OF ASTM C-478. 2. ASSEMBLE RISERS SO ALL STEPS WILL HAVE A 16" SPACING THE FULL HEIGHT OF MANHOLE. FIRST STEP SHALL BE MAXIMUM 22" ABOVE BENCH. MH STEPS AND COVER SHALL BE ALIGNED OVER OUTLET PIPE. 3. PROVIDE APPROVED GASKET AT ALL VERTICAL JOINTS, FILL ALL OUTSIDE AND INSIDE JOINTS AND LIFT HOLES WITH NON -SHRINK GROUT. 4. FRAME AND COVER SHALL BE U.S. FOUNDRY #669-KL AND HAVE "SANITARY SEWER" LABEL AND (2)1"0 VENT HOLES. USE #669-KL-BWTL WITHOUT HOLES FOR WATERTIGHT LIDS. PROVIDE ROPE MASTIC BETWEEN FRAME AND CONCRETE. IF FRAME IS NOT SURROUND BY CONSTRUCTION MATERIAL, PROVIDE (4) 3/8"x1.5" 304 SS LAG ANCHOR BOLTS THRU FRAME AND INTO CONCRETE WITH LEAD SHIELD ANCHORS. 5. WHERE MANHOLE TOP COULD BE SUBJECT TO VEHICULAR TRAFFIC, PROVIDE CONCRETE COLLAR WITH MINIMUM 6"D x12"W WITH TOP OF CONCRETE BEING 1.5" BELOW RIM. 6. GRADE TO DRAIN AWAY FROM MANHOLE RING AND COVER AS NEEDED. 7. TYPICAL MANHOLES ARE TO BE EXTENDED BASE UNLESS OTHERWISE APPROVED BY COUNTY ENGINEER OF RECORD. PRECAST SANITARY SEWER MANHOLE REF. NCDOT RSD S40.67 32 840-67WS+ FRAME AND COVER FLAT TOP IF NOTED PVC DI ON PROFILE 2 DIA. . 4' DIA. FM o V4x4 TEE v 4" CAP GROUT OPEN'G SS STRAP & PIPE ANC'S 2' AT 24" O.C. ° 90 BEND TO FOLLOW r SEWER FLOW ' V , . y L +s---------------T1 ogI NOTES: 1. SEE STANDARD PRECAST SANITARY SEWER MANHOLE FOR ADDITIONAL MANHOLE DETAILS. 2. PROVIDE DUCTILE IRON PIPE AND FLANGE FITTINGS INSIDE MANHOLE. FORCEMAIN OUTLET INSIDE DROP MANHOLE 52 8401d 4fm+ to w i= J D U =i m D 0- I- z D O U W a I� #4 BAR W/ OVERLAP 4000 PSI OnO CAST-IN-PLACE00 ,;•J��•- CLASS 'B' CONCRETE 1-18" SQ. PLAN AWAYE FROM VALVE COVER GROUND TN� CDC ' I W1 d J 2„ NOTE:-� M TL. METAL VALVE CLR VALVE BOX SHALL TYP' BOX BE STAR PIPE VB5625 OR EQAUL S L C T� O N GATE VALVE VALVE BUA PAD CAST -IN -PLACE IN PAVED AREA O 24 W-VALBX-PAD-DC Z IV SHEET: 1 OF 1 05/24/21 04 �_ _ 3 > Gse Zo O C W U > •; SHEET: 1 OF 1 05/20/2S o GSB 4.02 O m \ (A o� N o 0 V M � mo• I REVISED 10/08/20 w w V ] Page 51 of 63 ¢ _ a- u) VALVE BOX PAD & COLLAR 7 Woo ���k��l�l.[+ki..kil - f - gL PRECAST CONC. v - _, ; V.` d COLLAR GROUTGAP d PLAN 2' GROUT GROUND GAP I r77114" I-Ip -I M TL. NOTE: VALVE METAL VALVE BOX BOX SHALL BE STAR PIPE VB5625 OR EQAUUL GATE VALVE I SE� O N VALVE [0 LEAFR PRECAST IN UNPAVED AREA 24 W-VALBX- COLLAR- DC DAVIE COUNTY PUBLIC UTILITIES NOTES: 1. ALL DIMENSIONS ARE APPROXIMATE. 2. BACKFLOW PREVENTER LOCATION REQUIRES PRIOR APPROVAL, MUST BE WITHIN 10 FT OF METER ON THE PROPERTY SIDE AND MUST NOT OBSTRUCT SIGHT DISTANCE. PROVIDE 36" CLEAR OUTSIDE OF ENCLOSURE ON ALL SIDES. 3. SLAB SHALL BE 3000 PSI CONCRETE, 36"LONG x 22"WIDE x 4"THICK WITH 6x6-W1.4XW1.4 WWF OVER 3" COMPACTED CRUSHED STONE. 4. REDUCED PRESSURE BACKFLOW PREVENTER SHALL BE A 'WATTS' 1" 909-OT (OR EQUAL). SHUT-OFF VALVES SHALL BE FULL PORT, LINE SIZE AND 1/4 TURN BRONZE UNION BALL VALVES. 5. PIPE RISERS AND BENDS SHALL BE TYPE 'K' COPPER OR BRASS FOR A MINIMUM OF 5 FT EACH SIDE OF VALVES. 6. THE ENCLOSURE SHALL BE A 'HOT -BOX' OHF013027023 (OR EQUAL) FIBERGLASS AND HAVE A FLIP -TOP ACCESS, LOCKABLE SS HASP & (2)TWO DRAINPORTS. 7. REQUIRED ELECTRICAL RECEPTACLE INDICATED BY ❑E SHALL BE MOUNTED A MINIMUM OF 16" ABOVE THE SLAB. 8, THE ENCLOSURE SHALL BE HEATED WITH A 600, 120V, 12 FT LONG HEAT TRACE CABLE. 1" REDUCED PRESSURE BACKFLOW PREVENTER 12 W-BX-RPBFP H61 100 909-QT 1" REDUCED PRESSURE DAVIE COUNTY PUBLIC UTILITIES BACKFLOW PREVENTER doviecount+AC aov r3361753-fi090 2' � UNI-FLANGE EXTERIOR BLDG. WALL SLEEVE & CAULK ��� FINISH FLOOR FINISH GRADE � ff PROVIDE ASPHALT COATED STEEL z z SLEEVE THROUGH O FLOOR. CAULK AND `9 0 w WATERPROOF. I 0 3/4" ATR, NUTS & ROD COUPLING (2) 8" DUC ILE IRON PIPE I I 11111 (REF. TO NFPA 24) MJ90 WITH CONCRETE PROVIDE 12" THRUST BLOCK ASPHALT COATED (REF. TO NFPA 24) STEEL SLEEVE UNDER BUILDING FOOTING. 8�� FIRE LINE BUILDING ENTRY 32 W-FIRE BLDG ENTRY 800 SHEET: 1 OF 1 05/20/20 8" FIRE LINE BUILDING ENTRY w4. 1 0 GSB o J i'n 1- ::)� U _1 m 0_ zo OU W o > ao 0� W I­__J I O Z Q 0 :2 z Q_ Q 0 W 0 U W Q' 0 O V) z \0 \0 \0 o V O V O O O o 00 0� ao Page 54 of 63 a- a_ = (n w Page 58 of 63 d a_ w J = n Page fit of 63 DAVIE COUNTY PUBLIC UTILITIES MATERIAL KEYNQIE5 O COUPLING: IPT-COMP O PIPE: 2" TYPE 'K' COPPER O COUPLING: COMP-IPT ,,i 4 3 2 z (USE STICK PIPE ONLY FOR w o - STRAIGHT SECTIONS SHOWN) O4 COUPLING: COMP -COMP I, m SEE - to 2" RPZ NOTES j 3'-10" MIN, 2't 3'-10" MIN. 2'-6" 2' GROUND =' ��-----�•° °--�' GROUND GROUND I=III C I I=I m -III III- METER 1/2" EXP. JT. SERVICE w VALVE BOX 04 -I SIDE I=I 2 BRICK MAT'L TYP. SIDE a > COLLAR/PAD SEE DTL 2.31 -I ---- LI A - HGT. MAX. 1 0 �' L----; TYP. (DO TO O 3 2 BLDG. METER KEYNOTES NOTE: IPT-PVC (DSETTER: MUELLER 2" B2423-2N 12" HGT. WITH SET METER BOX TO GRADE ON 12 BRICKS. (TWO 300 PSI BALL ANGLE VALVE VALVE OUTLET AND BALL VALVE INLET, ANGLE CHECK BYPASS BRICKS HIGH UNDER CORNERS &LONG SIDES) A 2" BRICK PROJECTION MAXIMUM INTO THE METER SPACE. O METER BOX: 17x30x18 PLASTIC BOX & LID EQUAL TO 'NDS' PRO 126BCDWB OMETER: MUELLER FLANGED MVR160 WITH ME8 2 WATER METER & 2" RPZ (MLNET NODE AMR) IN GALS, 24 W-MTR2 +RPZ2 DC SHEET: 1 OF 2 07/14/21 2" WATER METER & 2" RPZ GSB DAVIE COUNTY PUBLIC UTILITIES 3.07 daviecountyNC.gov (336)753-6090 niiiil I III II� t 1t/'■1\�1_�s=V._■_�/t_'-�a' -._!1%1111I111,�' r1r �: rr ■ r Ilw �:,' ie Irk"ti Ali °�i ` 1II;i \11 NOTES: 1. BACKFLOW PREVENTER LOCATION REQUIRES PRIOR APPROVAL, MUST BE WITHIN 10 FT OF METER ON THE PROPERTY SIDE AND MUST NOT OBSTRUCT SIGHT DISTANCE. PROVIDE 36" CLEAR OUTSIDE OF ENCLOSURE ON ALL SIDES. 2. SLAB SHALL BE 3000 PSI CONCRETE, 4"THICK WITH 6x6-W4XW4 WWF OVER 3" COMPACTED CRUSHED STONE. 3. BACKFLOW PREVENTER SHALL BE A 'FEBCO' 8" 826YD WITH AWWA RESILIENT WEDGE GATE VALVES. 4. PIPE RISERS AND BENDS SHALL BE DUCTILE IRON FOR A MINIMUM OF 8 FT EACH SIDE OF GATE VALVES. ALL BELOW GROUND FITTINGS SHALL BE RESTRAINED MECHANICAL JOINTS. PLAN 4" CHECK VALVE INSULATED ABOVE 5. THE ENCLOSURE SHALL BE A ALUMINUM 'HOT -BOX' WITH BALL DRIP GROUND ENCLOSURE JUA045106062500 WITH FDC PENETRATION AND REMOVABLE PARTS JOINED ALONG THE LONGITUDINAL CENTERLINE, INSULATED TO R8, 2.83" 8'-4.35" 2.83'• HAVE AN ACCESS OPENING 'A.O.' ON BOTH SIDES N 8" FEBCO AS SHOWN AND DRAIN PORTS AT GRADE. NO 0 826YD LIFTING HANDLES ON THE REAR SECTION DUE TO PENETRATION. ENCLOSURE COLOR SHALL BE BEIGE PIPE"`j 6. NO BY-PASS OF BACKFLOW PREVENTER WILL BE STAND 'n ACCEPTED. BCL FP rn - j 7. PROVIDE "FIRE DEPARTMENT CONNECTION" SIGNAGE IN ACCORDANCE WITH STATE AND LOCAL PIPE STAND . REGULATIONS. (TYP. OF 3)- 8. TWO REQUIRED ELECTRICAL RECEPTACLE INDICATED F-A�EGROUND BY :] SHALL BE A GFl MOUNTED A MINIMUM OF 30" ABOVE THE SLAB. 1/2 EXP. 4" CONC. SLAB OVER (2) 3/4" n JT, MAT'L 3" STONE COMPACTED I uwi RODS AT 9. THE ENCLOSURE SHALL BE HEATED WITH TWO TYP. �- � ' EA. RISER I 1500W, 120V SINGLE PHASE HEATERS. 2" DIA. GALV. SCH 40 � STEEL BRACE BETWEEN METER CAPS WITH CONC. EA. END ' SERVICE SIDE 1° SIDE 8" FIRE LINE RPZ & CONC. THRUST FDC IN AN ENCLOSURE 8" DI BLOCK TO UNCUT DI EARTH TYP. SECTION 32 W-FIRE RPZ+FDC 800 SHEET: 1 of 1 05/20/20 8" FIRE LINE RPZ & FDC GSB DAVIE COUNTY PUBLIC UTILITIES 4. 0-9 IN AN ENCLOSURE doviecount+AC aov r3361753-fi090 (D Z Eu w Z (D z w to 0 N N C (N Z� ww 2 0W V � � OZ o ALu 0 0 0< oa 0 [N 01 PE SEAL: C `CARO .• 0 %. � o I SEAL 045345 .'•��G I N' � 0 C��% ., �� : % BUG �'� 02/21/2023 N 1 Q J Wtn J Ix O W � H �a � V = W W a�z p O"I a V = Z 0 V W =ZW W V) ::) 0 mn O Lu J O V = Lu i W a� a 00 W V) N Y �z Cie Cie 33 V V J J mm Cie ww CL 0 W W _N N W W Cie , 04C4 (,4 (V y 04 O 01\ W CC CV C') m�3 CV N J Vk 0 r o LL w 0 wmm Lu _ 00 ZZ0 3 w to t- Lu Z�w w�= � w O V � NOTES: 1. CLASS OR MEDIAN SIZE OF RIPRAP AND LENGTH, WIDTH AND DEPTH OF APRON TO BE DESIGNED BY THE ENGINEER. 2. REFER TO THE NCDEQ EROSION & SEDIMENT CONTROL PLANNING & DESIGN MANUAL FOR RIPRAP APRON DESIGN STANDARDS. 3. RIPRAP SHOULD EXTEND UP BOTH SIDES OF THE APRON AND AROUND THE END OF THE PIPE OR CULVERT AT THE DISCHARGE OUTLET AT A MAXIMUM SLOPE OF 2:1 AND A HEIGHT NOT LESS THAN TWO THIRDS THE PIPE DIAMETER OR CULVERT HEIGHT. 4. THERE SHALL BE NO OVERFLOW FROM THE END OF THE APRON TO THE SURFACE OF THE RECEIVING CHANNEL. THE AREA TO BE PAVED OR RIPRAPPED SHALL BE UNDERCUT SO THAT THE INVERT OF THE APRON SHALL BE AT THE SAME GRADE (FLUSH) WITH THE SURFACE OF THE RECEIVING CHANNEL. THE APRON SHALL HAVE A CUTOFF OR TOE WALL AT THE DOWNSTREAM END. 5. THE WIDTH OF THE END OF THE APRON SHALL BE EQUAL TO THE BOTTOM WIDTH OF THE RECEIVING CHANNEL. MAXIMUM TAPER TO RECEIVING CHANNEL 5:1 6. ALL SUBGRADE FOR STRUCTURE TO BE COMPACTED TO 95X OR GREATER. 7. THE PLACING OF FILL, EITHER LOOSE OR COMPACTED IN THE RECEIVING CHANNEL SHALL NOT BE ALLOWED. B. NO BENDS OR CURVES IN THE HORIZONTAL ALIGNMENT OF THE APRON WILL BE PERMITTED. 9. FILTER FABRIC SHALL BE INSTALLED ON COMPACTED SUBGRADE PRIOR TO PLACEMENT OF RIP RAP. 10. ANY DISTURBED AREA FROM END OF APRON TO RECIEVING CHANNEL MUST BE STABILIZED. USE USDA NOMOGRAPH FROM NC SEDIMENT AND EROSION CONTROL MANUAL FOR DESIGN DATA. d50 (see fig 8.06 akb "NC SEDIMENT AND EROSION CONTROL MANUAL" dmax = 1.5 x d50 T = 1.5 X dmax. T(min.)=10" GENERAL NOTES: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACING A 2-FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NC DOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUNDCOVER. NATURAL rM PLAN (IF NEEDED) ELEVATION 1 1MIN. T RIP RAP _ML T (THICKNESS)=10" MIN. NOTE: LAYER OF FILTER FABRIC MINIMUM H=2/3 PIPE DIAMETER SECTION B-B RIPRAP APRON AT PIPE OUTFALLS OTHER THAN AT SWI M NCDOT #5 WASHED NCDOT #5 WASHED HARDWARE CLOTH AND GRAVEL INLET PROTECTDON RE ENINGS) NOT TO SCALE S EXPANSION JOINTS 6° E� 4r 61, 41-611 \1 #4 BARS "V" 6" 6" STD. 840.03 FRAME, @ EQUAL SPACES 11/2 ,+-� 1 %2" GRATE & HOOD 311 Im _� R cn R M j¢ Q h-• 6'-0" � P LAN 0� J m ¢ LL CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES D] Q LL 7 rp Lu TOP cl) USE ON FLAT ELEV. EXPANSION JOINT 6' GRADES 2% AND UNDER \ 7 S _ I DEPRESSED GUTTER LINE EXPANSION JOINT 3 01 I m 1 3 Q PLAN OF TOP SLAB SECTION S-S �' ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE 6" E #8 "W" BARS #4 BAR EXPANSION JOINT 6.r+ 8 TOP BARS "V" cv USE ON GRADES OVER 2� ELEV. EQUAL SPACES - -1011 1 DEPRESSED GUTTER LINE " " L6- I EXPANSION JOINT 1 01 1 I MAX. #4 BARS U tl„ DOWEL ELEVATION SECTION R - R NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIN(BASED ON MIN. HEIGHT, H, WITH NO RISER) DIMENSIONS OF BOX AND PIPE COVER DIMENSION CU.YDS. CONC. IN BOX DEDUCTIONS ONE PIPE PIPE SPAN WIDTH WIDTH SPAN MIN. HEIGHT BARS-U NO. LENGTH BARS-V NO. LENGTH BARS-W NO. LENGTH TOTAL LBS. TOP SLAB BOTTOM SLAB TOT.CONC. ON MINIMUM HEIGHT H D A B C G H E F C.M. R.C. 12" 3'-0" 2'-2" 2'-9" 0.235 0.772 0.015 0.026 151, 3'-0" 2'-2" 31-01, 0.235 0.829 0.023 0.036 181, 3'-0" 2'-2" 31-31, 0.235 0.887 0.033 0.049 24" 3'-01f 2'-2 r 3'-9" 0.235 1 .001 0.059 0.085 30" 3'-0" 2'-2" T-4" 4'-31' V-2" 4'-0" 4 1'-51, 2 T-9" 3 3'-9" 39 0.123 0.321 1.433 0.092 0.127 36" 3'-0'' 2-2'` 3'-10" 4' 9 11_g'/ 4_0'' 4 1'111" 3 3' 9'1 3 3`-9" 43 0.161 0.$58 1.714 0.132 0.178 42" 3 -0 2'- 2' 4'- 5 5' 3" 1 -5 3'- 2' 4 1 -8' 2 2 -11 ' 3 21 11 32 0.112 0.318 1.738 0.180 0.243 48" 3'-0" 2'-2" 51-01, 5'-9" 2'-0" 3'-2" 4 2'-3" 3 2'-11° 3 2'-11" 35 0.145 0.352 2.052 0.235 10.317 54" 3'-0" 2'-2" 5'-7" 6'-3" 2'-7" 3'-2" 4 2'-10" 5 2'-11" 3 2'-11" 43r' NOTE: USE TYPE "E", "F" AND "G" GRATE UNLESS OTHERWISE NOTED. .. PLAN FRAME,GRATE, & HOOD ASS'Y SECTION - KK a to nrrir"E:SSION SECTION G-G 2'-31/4r, 1 N6,r 2rr SECTION H-H ALIGN FRAME WITH INSIDE EDGE OF WALL TO ALLOW FOR VERTICAL ADJUSTMENT o. WALL SECTION SECTION - BB r rnrun� r�n�� 3' R --d" 41 0.180 0.386 2.387 0.297 0.401 * RISER HAS .228 CUBIC YARDS OF CONCRETE PER FOOT HEIGHT a N� 21/8,r SECTION - LL T� T SECTION - PP =1 11/2rr 6" 2r-Or, 6" rr r 3 „��-T� 3/ r r } Q3/4 rr r `Y � 1 rr �6 2'-111/2„ R HOOD ELEVATION �1 1/2 u c 1 %2 to 8 rr r� H �G� o G l l 0 C9 `- 0-- --- T [V O_ 0 I� `N H v7� T H421r 41�2rr 1 r 75/8rr PLAN OF GRATING CAST IRON O Z LL C'3 U) H m 0- CL d' LO cc v 0 0 cr Q W F- W } N r- 0 O 0 V L1C HEET 2 OF 2 840.02 z O � H } H PL�II L 3r, P z�= , U r 1flf F-I O LLJ�I-I 0 = IT f]C WQzL= 21/8„ HU�00 I --I N N H _j SECTION - MMI CO LL o o O {{ j < z H d I-i LLI 0 r r T SECTION - NN 4�"-^ jI :zfl `N co 3rr _Y41 I _ 1 LL C) m _ cp Cm = _ rn 1 4 Y H C U Z Q a 0 � ?3/" O n O Q W za¢ SECTION - JJ } e' O Q W rr 55/8 W 1/2 rr S Q Q p 311 R 0 _T z0 r1 1/2 ?' 1/2 rr LL 4rJ/$rr SECTION - RR SHEET 1 OF 2 840.03 3r-6rr F � 1 E CD 1 �- N El - -i I F PLAN OF FRAME CAST IRON 1/8 rr 1/8 rr �8 rr 1/8 it 1++ If 1 r r 1 r r 31-33/4rr 2'-33/+r i/8 fr � to 1/8 1/8 !! rr U $ O 3/ rr 3/ rr I I 3/ of 3/ of It 31 2n 2'-2+' 21/8rr_ 21/8rr� 3'-13/4rr CV N 2r-13� N N 3'-6rr 2'-6rr SECTION E-E SECTION F-F z O cn Q Q H U LL J I--i z 00cj)= WQQLL= QUC=010-I u_ :c Z � 0 O cf) Q z H � H > CL H W 0 0 r V) d W 00 H 0 LL a H � T Q Z 0 <a� O CD o W � Qa� z O Q 0 ~Lu 0 } J Z = p H H Q H 0 C O W CA 0 = O LL SHEET 1 OF 1 840.16 S-01 6 E---j ' #4 BARS "V" I 6 @ EQUAL SPACES 3rp 1 /2 „ R U) R � U W cr Q J 0] Q LL Itw m � S PLAN OF TOP SLAB 6" E #8 "W" BARS 1, ll SPACES io #4 SECTION R-R 6ll IT-, 1,,211 cn t w p¢ m� m ¢ LL * w ih SECTION S-S #4 BAR N L6j DOWEL EXPANSION JOINTS 4'-6" 1 4'-6" STD. 840.03 FRAME, GRATE & HOOD F-� 6'- 0' PLAN CURB AND GUTTER WITH CATCH BASIN ON STEEP GRADES TOP USE ON FLAT ELEV. EXPANSION JOINT 6' GRADES 2% AND UNDER _ I DEPRESSED GUTTER LINE EXPANSION JOINT I 00 ELEVATION NORMAL CURB AND GUTTER ON LIGHT GRADES NORMAL GUTTER LINE EXPANSION JOINT 6r+ 811 TOP USE ON GRADES OVER 2� ELEV. -10 1 6E O ESSED GUTTER LINE EXPANSION JOINT 1, 0„ 1MI MAX. MI ELEVATION NORMAL CURB AND GUTTER ON STEEP GRADES MINIMUM DIMENSIONS AND QUANTITIES FOR CONCRETE CATCH BASIN(BASED ON MIN. HEIGHT, H, WITH NO RISER) DIMENSIONS OF BOX AND PIPE COVER DIMENSION CU.YDS. CONC. IN BOX DEDUCTIONS ONE PIPE PIPE SPAN IWIDTH WIDTH SPAN MIN. HEIGHT BARS-U NO. LENGTH BARS-V NO. LENGTH BARS-W NO. LENGTH TOTAL LBS. TOP SLAB BOTTOM SLAB TOT.CONC. E MINIMUM HEIGHT H D A B C G H E F C.M. R.C. 12" 3'-0" 2'-2" 2'-9" 0.235 0.772 0.015 0.026 151, 3'-0" 2'-2" 3`-0" 0.235 0.829 0.023 0.036 181, 3'-0" 2'-2" 3'-3" 0.235 0.887 0.033 0.049 24" 3'-0" 2'-2" 3'-9" 0.235 1.001 0.059 0.085 30" 3'-0" 2'-2" 3'-4" 4'-3" V -2" 4'-0" 4 V -5" 2 T- 9 3 3'-9" 39 0.123 0.321 1.433 0.092 0.127 36" 3'-0" 2'-2" 3'-10" 4'-9" 1'-8" 4'-0" 4 1'-11" 3 3'-9" 3 3'-9" 43 0.161 0.358 1.714 0.132 0.178 42" 3'-0" 2'-2" 4'-5" 5' 3" it-5" 3'-2" 4 1' 8" 2 2' 11" 3 2' 11" 32 0.112 0.318 1.738 0.180 0.243 48" 3'-0" 2'-2" 51-0" 51-91, 2'-0" 3'-2" 1 4 2`-3° 3 2'-11" 1 3 2`-11" 35 0.145 0.352 1 2.052 0.2 55 0.317 54" 3'-0" 2'-2" 5'-7" 6'-3" 2'-711 1 3'-2" 1 4 2'-10" 5 2'-11" 1 3 2'-11" 41 0.180 0.386 ^" WEEP HOLES J Y I PLAN WITH GRATE & FRAME REMOVED BRICK COPING(INCIDENTAL) TOP ELEVATION STD. 840.16 FRAME - I & GRATE I fi 1' p 6" s" vi z I I m SEE NOTE DOWEL(SEE NOTE) SECTION X-X 2.387 0.297 0.401 * RISER HAS .228 CUBIC YARDS OF CONCRETE PER FOOT HEIGHT GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB A5 SHOWN ON STD. NO. 840.00. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 78M STONE IN A POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. #4 BAR B 6" N x I DOWEL MAX. PIPE THIS SIDE - 18' SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONC. IN BOX DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH MIN. HEIGHT D A B H BOTTOM SLAB WALL PER FT. HT. TOT WINEAL coN E FOR xIGHT, iw, H HEH C.M. R.C. 12" 3'-0" 2'-0" 2'-0" 0.222 0.222 0.592 0.015 0.026 15" 2'-3" 0.648 0.023 0.036 18" 2'-6" 0.703 0.033 0.049 24 3'-0" 0.814 0.059 0.085 30" 3' O" 2'-0" 3' 6" 0.222 0.222 0.925 0.092 0.127 F iL MANHOLE E C L D ��.,4 D i / �?n•i`�� 1 a�Q 1 �' �I CL A -41 - 3 co _.D.54 C FOR MANHOLE COVER & FRAME # PLAN OPTIONALSPACED 6" C. TO C. BRICK MAY BE USED TO ADJUST FRAME & „ COVER TO SURFACE ELEVATION MAX. 1' p. cn - L •1 OUTLET PIPE a 6 , E OR F �2 fi A SECTION 61 C-C OR D-D SECTION X-X SECTION Y-Y GENERAL NOTES: CHAMFER ALL EXPOSED CORNERS 1". USE CLASS "B" CONCRETE THROUGHOUT. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS TO CONSTRUCT THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. PROVIDE ALL JUNCTION BOXES OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ELEVATION IS 12 FEET. #4 BAR DOWEL DIMENSIONS AND QUANTITIES FOR CONCRETE JUNCTION BOXES DIMENSIONS OF BOX AND PIPE REINFORCEMENT BARS "A" TOP SLAB DIMENSIONS CUBIC YARDS IN BOX TOTAL QUANTITIES BOX AND SLABS DEDUCTIONS FOR ONE PIPE CU.YDS. PIPE SPAN WIDTH HEIGHT D A B H NO. LENGTH E F TOP SLAB BOTTOM SLAB WALL/ FT. 4F HT. LBS. REINF CU. YDS. MIN. H C. S. R.C. 12" 2'-0" 2'-0" 2'-3" 12 2'-9" 3'-0" 3'-0" 0.167 0.167 0.185 22 0.750 0.015 0.024 15" 1 2'-3" 2'-3" 2'-6" 12 310" 3'-3" 3'-3" 0.196 1 0,196 0.204 24 0.902 0.023 1 0.036 18" 2'-6" 2'-6" 2'-9" 14 3'-3" 3'-6" 3'-6" 0.227 0.227 0.222 30 1.065 0.033 0.049 24" 3'-011 31-01` 3'-31, 16 3'-9" 41-0" 4'-0" 0.296 0.296 0.259 40 1.434 0.059 0.085 301, 3'-6" 3'-6" 3'-9" 18 4'-3" 4'-6" 4'-6" 0.375 0.375 0.296 51 1.860 0.092 0.127 36" 4'-0" 4'-0" 4'-3" 20 4'-9" 5'-0" 5'-01, 0.463 0.463 D.333 64 2.341 0.132 0.178 42" 4'-6" 4'-6" 4'-9" 22 5'-3" 5'-6" 5'-6" 0.560 0.560 0.370 77 2.878 0.180 0.243 48" 5'-4" 5'-4" 5'-3" 26 6'-3" 6'-4" 6'-4" 0.743 0.743 0.407 111 3.623 0.235 0.317 54" 5'-10" 5'-10" 51-91, 28 6'-7" 6'-101f 6'-10" 0.865 0.865 0.444 126 4.283 0.297 0.401 601, 61-6" 1 6'-6" 6'-3" 30 7'-3" 1 7'-6" 7'-6" 1.042 1.042 0.481 145 5.090 0.367 0.495 66" 7'-1" 7'-1" 6'-9" 32 V-10" 1 8'-1" 8'-1" 1.210 1.210 0.518 169 5.917 0.444 0.589 z O� < Q Q " O ( L J U La- 0 0 c _ WQzLL. = Q0C=0C I Z LLJ pOCOQ z ,jam CL d 0 r LLI O Z LL C'3 U) H m CL CL d' cc 0 cr Q W F W = N r- 0 0 O V OC HEET 2 OF 2 840.02 z O � H } H Q Q LL J I--i 0 0 cj) _ WQQLL. = QU=01O-I CO- :c Z � O c" Q z H H > d m r Q 0 O LL Lu CD J Z Z W 1--I © � O � Q Cr) Z W = w W ~ N r- o z O 0 Q ct HEET 1 OF 1 840.14 z O TUa Q Q � r, U LL, J � I--i z 00cj)= WQQLL- F- 0 0 CD O cf) Q z H � H > CL I --I r Q 0 0 x LL Q C'3 CO J O LiJ O z 1 H Q CL p m v J to ©zQ(� 0 Oy °C ~ 1.- 0 ~ 07 } W N gV 1--i r" Q O 0 (� ac JEET 1 OF 1 840.31 (D Z LL Lu Z (D Z LL to 0 N N CN� N r., Z� w w Z Ow (j o� < V � � QZ O J O D Lu OU 0 0, Z C4 Z 01 PE SEAL: ,��ssiFssss♦ �� �• .• O 7%10 • �. I SEAL 045345 • •'•:�G A I�••• c *114111911* 02/21/2023 N 1 Q J WZ tn 12 �mm o� _ 00 ima Le)U < = W W Z p O"i a V =Z0 V W = Z L>i,i W V) : 0 O J O Lu = LLI > QC W > a 0 C0 L W N Z 0 _N W N qq mF_3 CNI o LL O Lu Z Z Lu � L~u 2 3w V Z�w w�= � w 0 V �