February 17, 2023
Amanda Berger, Environmental Compliance Director
Aqua North Carolina, Inc.
202 MacKenan Drive
Cary, NC 27511
Subject: Compliance Evaluation Inspection
The Preserve at Jordan Lake WWTP
Non -Discharge Permit No. WQ0018146
Chatham County
Dear Ms. Berger:
On January 18, 2023, Cassidy Kurtz from the Raleigh Regional Office conducted a compliance
evaluation inspection of the Reclaimed Water Generation and Dedicated Utilization System for
the Preserve at Jordan Lake WWTP. The purpose of this inspection was to ensure compliance
with the conditions and limitations specified in Non -discharge Permit No. WQ0018146. During
the inspection, the cooperation and assistance of Katie Dickens, Eric Riggins, and Jade Wicker
was greatly appreciated.
This compliance evaluation inspection consisted of the following:
Review of the permit,
Review of ORC logbooks, calibration documentation, non -discharge monitoring reports
(NDMRs), non -discharge application reports (NDARs), and
On -site inspection of the treatment components and spray fields.
The current permit was issued May 12, 2020 and expires September 30, 2026.
Components of the wastewater system appeared to be overall well -maintained and operational.
At the time of inspection, water in the upset and irrigation storage ponds was free of floating
solids and plenty of freeboard was available. The backup generator is run on a weekly basis
under load for about 15-30 minutes. Irrigation is typically conducted overnight to avoid contact
with golfers, and signage was posted at the clubhouse. During the inspection, the irrigation areas
for the front nine holes of the golf course were observed, and the sprinklers were activated at
each hole unoccupied by golfers. The observed irrigation areas appeared to have good spray
patterns and even coverage.
The records review portion of the inspection included review of NDMRs, NDARs, Operation
and Maintenance Plan and log, residuals log, calibration records, and educational materials. Lab
results were compared to submitted NDMRs for January and September 2022 (amended NDMRs
were submitted for September); no typographical errors were noted. NDARs were reviewed for
Wank CaalinaDepanotmtofEnvirompr'JQteliir< DtvisienofUtteefronten
Raleigl Regional Office : 3800 &wen Dsive 1 Raleigh, North (Valiaa27809
919 7914200
DocuSign Envelope ID: FFBC87E0-COCF-44BE-9B80-D29A4DD3C6DB
y...m....4 ar awl
the same months with no errors noted. The Operation and Maintenance Plan and log appear to be
thorough and includes pertinent information. Residuals are hauled every other month and were
hauled on the day of the inspection. The turbidimeter and flow meter were both last calibrated
November 15, 2022. The facility reported no bypasses, spills, sanitary sewer overflows, or public
complaints within the last 12 months.
The Reclaimed Water Generation and Dedicated Utilization System appears to be compliant with
permit requirements. If you have any questions about this inspection or this letter, please contact
Cassidy Kurtz at Cassid .Kurtz.{a.'ncdenr.i ov or (919) 791-4237.
Sincerely,
&uoocuntpns�la by:
t...,f,
82916EeAB32144F...
Vanessa E. Manuel
Assistant Regional Supervisor
Water Quality Regional Operations
Raleigh Regional Office
Attachments: EPA Water Compliance Inspection Report
CC: Laserfiche, Robert Krueger, Katie Dickens, Eric Riggins (email)
,,,Fru , North CYrolineDepi afRm+irom ik]Qmlity1 Division °M rResources
Ralei�RepoaaltJffiu I MOO 8streatDrive I Raleish.North Catalina 27d09
3
....„9
919 nil 4290
Compliance Inspection Report
Permit: W00018146
SOC:
County: Chatham
Region: Raleigh
Effective: 05/12/20
Effective:
Contact Person: Randy Simmons
Expiration: 09/30/26 Owner : Aqua North Carolina Inc
Expiration: Facility: The Preserve at Jordan Lake WWTP
800 Broad Leaf Ct
Title:
Chapel Hill NC 27517
Directions to Facility:
US 64 west, past Jordan Lake. Right on Big Woods Rd. Entrance is —2 miles on the left.
System Classifications: SI, WW2,
Primary ORC: Certification:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
WQ0018562 Aqua North Carolina Inc - The Preserve at Jordan Lake WWTP
Inspection Date: 01/18/2023
Primary Inspector: Cassidy Kurtz
Secondary Inspector(s):
Entry Time 11:30AM
Reason for Inspection: Routine
Permit Inspection Type: Reclaimed Water
Facility Status: • Compliant ❑ Not Compliant
Question Areas:
▪ Treatment Flow Measurement -Effluent
In Treatment Flow Measurement -Water
Use Records
▪ Treatment Filters
▪ Treatment Sludge Storage/Treatment
Treatment Disinfection
(See attachment summary)
•
•
Exit Time: 01 MPM
Phone: 336-992-9000
Phone:
Phone: 919-807-6388
Inspection Type: Compliance Evaluation
Treatment Flow Measurement -Influent
Treatment
▪ Record Keeping
▪ End Use -Irrigation
▪ Treatment Flow Measurement
II Miscellaneous Questions
In Treatment Barscreen
II Treatment Lagoons
11. Treatment Clarifiers
Standby Power
Page 1 of 6
Permit: WQ0018146 Owner - Facility: Aqua North Carolina Inc
Inspection Date: 01/18/2023 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Inspection Summary:
On January 18, 2023, Cassidy Kurtz from the Raleigh Regional Office conducted a compliance evaluation inspection of the
Reclaimed Water Generation and Dedicated Utilization System for the Preserve at Jordan Lake WWTP. The purpose of this
inspection was to ensure compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0018146.
During the inspection, the cooperation and assistance of Katie Dickens, Eric Riggins, and Jade Wicker was greatly
appreciated.
This compliance evaluation inspection consisted of the following:
- Review of the permit,
- Review of ORC logbooks, calibration documentation, non -discharge monitoring reports (NDMRs), non -discharge
application reports (NDARs), and
- On -site inspection of the treatment components and spray fields.
The current permit was issued May 12, 2020 and expires September 30, 2026.
Components of the wastewater system appeared to be overall well -maintained and operational. At the time of inspection,
water in the upset and irrigation storage ponds was free of floating solids and plenty of freeboard was available. The backup
generator is run on a weekly basis under load for about 15-30 minutes. Irrigation is typically conducted overnight to avoid
contact with golfers, and signage was posted at the clubhouse. During the inspection, the irrigation areas for the front nine
holes of the golf course were observed, and the sprinklers were activated at each hole unoccupied by golfers. The observed
irrigation areas appeared to have good spray patterns and even coverage.
The records review portion of the inspection included review of NDMRs, NDARs, Operation and Maintenance Plan and log,
residuals log, calibration records, and educational materials. Lab results were compared to submitted NDMRs for January
and September 2022 (amended NDMRs were submitted for September); no typographical errors were noted. NDARs were
reviewed for the same months with no errors noted. The Operation and Maintenance Plan and log appear to be thorough anc
includes pertinent information. Residuals are hauled every other month and were hauled on the day of the inspection. The
turbidimeter and flow meter were both last calibrated November 15, 2022. The facility reported no bypasses, spills, sanitary
sewer overflows, or public complaints within the last 12 months.
The Reclaimed Water Generation and Dedicated Utilization System appears to be compliant with permit requirements.
Page 2 of 6
Permit: W00018146 Owner - Facility:Aqua North Carolina Inc
Inspection Date: 01/18/2023 inspection Type :Compliance Evaluation
Reason for Visit: Routine
Type
Reuse (Quality)
Lagoon Spray, LR
Infiltration System
Single Family Spray, LR
Activated Sludge Spray, LR
Activated Sludge Drip, LR
Activated Sludge Spray, HR
Recycle/Reuse
Single Family Drip
Treatment
Are Treatment facilities consistent with those outlined in the current permit?
Do all treatment units appear to be operational? (if no, note below.)
Comment. No tablet chlorine used: liquid hvpochlorite used
Treatment Flow Measurement -Influent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment:
Treatment Flow Measurement -Water Use Records
Is water use metered?
Are the daily average values properly calculated?
Comment:
Treatment Flow Measurement -Effluent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment- Flow meter last calibrated 11/14/22
Standby Power
Is automatically activated standby power available?
Yes No NA NE
0
O
O
O
O
O
Yes No NA NE
❑ ■❑❑
• ❑ ❑ ❑
Yes No NA NE
❑❑■❑
120.10
❑ ❑•❑
❑ ❑■❑
DO MD
Yes No NA NE
❑ ❑•❑
❑ ❑•❑
Yes No NA NE
■ ❑❑❑
• ❑ ❑ ❑
■ ❑❑❑
• ❑❑❑
■ ❑❑❑
Yes No NA NE
■ ❑❑❑
Page 3 of 6
Permit: W00018146 Owner - Facility:Aqua North Carolina Inc
Inspection Date: 01/18/2023 Inspection Type :Comp ance Evaluation
Reason for Visit: Routine
Is generator tested weekly by interrupting primary power source?
Is generator operable?
Does generator have adequate fuel?
Comment: Generator run weekly under load
Treatment Barscreen
Is it free of excessive debris?
is disposal of screenings in compliance?
Are the bars spaced properly?
Is the unit in good condition?
Comment:
Treatment Clarifiers
Are the weirs level?
Are the weirs free of solids and algae?
Is the scum removal system operational?
Is the scum removal system accessible?
Is the sludge blanket at an acceptable level?
Is the effluent from the clarifier free of excessive solids?
Comment:
Treatment Filters
Is the filter media present?
Is the filter media the correct size and type?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids?
Is the mud well free of excessive solids and filter media?
Does backwashing frequency appear adequate?
Comment:
Treatment Sludge Storage/Treatment
Is the aeration operational?
Is the aeration pattern even?
If required, are Sanitary "Ts" present in tankage?
Comment:
Treatment Disinfection
Is the system working?
Do the fecal coliform results indicate proper disinfection?
■ ❑❑❑
❑ ❑❑■
❑ ❑❑■
Yes No NA NE
■ ❑❑❑
■ ❑❑❑
• ❑ ❑ ❑
■ ❑❑❑
Yes No NA NE
■ ❑❑❑
1.000
■ ❑❑❑
■ ❑❑❑
❑ ❑❑■
▪ ❑ ❑❑
Yes No NA NE
■ ❑❑❑
• ❑ ❑ ❑
❑ ❑❑■
❑ ❑❑■
• ❑ ❑ ❑
111000
❑ ❑❑■
Yes No NA NE
. ❑ ❑ ❑
• ❑❑❑
❑ ❑■❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Page 4 of 6
Permit: W00018146 Owner - Facility:Aqua North Carolina Inc
Inspection Date: 01/18/2023 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Is there adequate detention time (>=30 minutes)?
Is the system properly maintained?
If gas, does the cylinder storage appear safe?
Is the fan in the chlorine feed room and storage area operable?
Is the chlorinator accessible?
If tablets, are tablets present?
Are the tablets the proper size and type?
Is contact chamber free of sludge, solids, and growth?
If UV, are extra UV bulbs available?
If UV, is the UV intensity adequate?
# Is it a dual feed system?
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
If yes, then what is the EPA twelve digit ID Number? (1000- - )
If yes, then when was the RMP last updated?
Comment:
Record Keeping
Is a copy of current permit available?
Are monitoring reports present: NDMR?
NDAR?
Are flow rates less than of permitted flow?
Are flow rates Tess than of permitted flow?
Are application rates adhered to?
Is GW monitoring being conducted, if required (GW-59s submitted)?
Are all samples analyzed for all required parameters?
Are there any 2L GW quality violations?
Is GW-59A certification form completed for facility?
Is effluent sampled for same parameters as GW?
Do effluent concentrations exceed GW standards?
Are annual soil reports available?
# Are PAN records required?
# Did last soil report indicate a need for lime?
If so, has it been applied?
Are operational Togs present?
Are lab sheets available for review?
Do lab sheets support data reported on NDMR?
■ ❑D❑
■ ❑❑❑
❑ ❑ ■ ❑
O 0.0
• 000
❑ ❑ ■ ❑
O 0.0
• 000
• 000
O EM.
■ ❑❑❑
❑ D■❑
❑ ❑ ■ ❑
Yes No NA NE
• 000
■ ❑❑❑
■ DDD
■ ❑ DD
■ ❑ El
■ ❑ ❑ ❑
❑ ❑■D
O 000
❑ ❑■❑
❑ ❑■❑
❑ ❑■❑
❑ ❑■❑
❑ ❑■❑
❑ ❑■❑
D❑■❑
❑ ❑■❑
■ ❑❑❑
■ ❑❑❑
■ ❑❑❑
Page 5 of 6
Permit: WCt0018146 Owner - Facility: Aqua North Carolina Inc
Inspection Date: 01 /1812023 Inspection Type : Compliance Evaluation
Reason for Visit: Rout ne
Do lab sheets support data reported on GW-59s?
Are Operational and Maintenance records present?
Were Operational and Ma ntenance records complete?
Has permittee been free of public compla nts in last 12 months?
Is a copy of the SOC readily available?
No treatment units bypassed since last inspection?
Comment:
End Use -Irrigation
Are buffers adequate?
Is the cover crop type specified in permit?
Is the crop cover acceptable?
Is the site condition adequate?
Is the site free of runoff / ponding?
Is the acreage specified in the permit being utilized?
Is the application equipment present?
Is the application equipment operational?
Is the disposal field free of limiting slopes?
Is access restricted and/or signs posted during active site use?
Are any supply wells within the CB?
Are any supply wells within 250' of the CB?
How close is the closest water supply well?
Is municipal water available in the area?
# Info only: Does the permit call for monitoring wells?
Are GW monitoring wells located properly w/ respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
Are monitoring wells damaged?
Comment:
El II
■ ❑ ❑ ❑
■ ❑❑D
■ ❑❑❑
CI CI
■ ❑❑❑
Yes No NA NE
■ ❑ ❑ ❑
▪ El
CI ■❑❑❑
■ ❑❑❑
■ ❑❑❑
■ ❑❑❑
■ ❑❑❑
■ ❑❑❑
■ ❑❑❑
■ ❑❑❑
D❑■❑
❑ ❑ ■ ❑
❑ ❑ ■ ❑
❑ ❑■D
❑ ❑■❑
❑ ❑■❑
❑ ❑■❑
❑ ❑ ■❑
Page 6 of 6