HomeMy WebLinkAboutNCG551563_Inspection completed by contractor_20230209Name and Address of System Inspector: McFarland Septic 6801 Mount Hermon Church Road Durham, NC 27705 (919) 383-1015 Inspection Date: 2/9/2023 Service Call County System Classification & Type Durham Surface Drip Sub -Surface Drip ❑ Spray System ❑ Surface Discharge �1 Name and Address of Owner: David Gaster 209 Patterson Rd. Durham, NC 27704 Location of System: 209 Patterson Road Durham, NC 27704 S = Satisfactory, M = Marginal, X = Unsatisfactory, N = Not Evaluated, NA = Not Applicable SEPTIC TANK Odors? Tank risers accessible? Signs of infiltration? Tanks and access structurally sound? 5 Sanitary tee(s) in good condition? 5 Effluent filter cleaned? 5 Effluent filter in good condition? 5 5 5 5 Septic Tank Water Depth Septic Tank needs pumping? Water Meter Reading: Sludge Scum Level Level 6" 1" 38" Yes No NA x EFFLUENT DOSING STATION Tank riser height? Signs of infiltration? Required pumps present & operating properly? High water alarm operating properly? Floats, pipes, valves, disconnects in good condition? Control panel enclosure/components in good condition? Effluent appears clear and free of solids? Rain sensor working properly? Pump Readings: Pump Spin Filter Flush Zone 1 Zone 2 Zone 3 Zone 4 Elapsed Time: Elapsed Time: Elapsed Time: Elapsed Time: Elapsed Time: Elapsed Time: Elapsed Time: NA NA NA NA NA NA NA Events Events Events Events Events Events Events NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA Alarm Events: NA Secondary Count: NA Power Failure: NA Timer: On: NA Off: NA HEADWORKS Vortex filter in good condition? Vortex filter manually flushed? Valves in good condition? Valves manually flushed? Pressure Readings: Pre -filter: Post -filter: Drainfield: Any visible leaks? Air vent in good condition? #1 NA NA NA NA NA NA NA NA NA #2 NA #3 NA #4 NA Overall Condition? NA GROUND ABSORPTION FIELDS Odors? S Rainfall in last 3 days? Yes 171 No ❑ No evidence of effluent surfacing? NA Surface water being effectively diverted away? S Line cover & vegetation cover maintained properly? S Protected from traffic, destructive uses? S Distribution devices in good working condition? S Repair area properly reserved, maintained? S Drainfield pressure (at air vent): #1 NA #2 NA #3 NA #4 NA Flow Meter Reading: NA Pre -Treatment Station: Advantex Media in good condition? S Media container in good condition? S Ponding on surface of media? S Excessive scum build up on surface? S Equal spray patterns? S Any orifices clogged? S Piping network flushed? S Does media need cleaning? S Squirt Height: Observed: NA Adjusted: NA Processing Tank: Tank Risers accessible? S Signs of infiltration? S Tanks & access structurally sound? S Effluent appears clear and free of solids? S Required pumps present & operating properly? S High water alarm operating properly? S Floats, pipes, valves, disconnects in good condition? S Control Panel enclosure/components in good condition? S Telemetry working properly? S RSV in good condition & operating properly? S Pump Readings: Elapsed: 2492.4 Events: 16371 Alarm Events: 0 Timer Settings: On: 0.8 Off: 10.0 Sludge Scum Level: 5" Level: 0-1" UV Disinfection Station: Basin Riser accessible? S Signs of infiltration? S Electrical components in good condition? S Any leaks? S Unit in good condition? S Intensity level: S Does bulb need replacing? S Cleaned quartz sleeve? S Any Alarms? S UV .25 amps RECOMMENDATIONS TO OWNER: 1. The connector for the UV bulb was burnt up when I arrived and the alarm was sounding. 2. Replaced UV bulb during visit. 3. The recirculation pod is still due for pumping. 4. The water level in the septic tank was several inches below the outlet pipe indicating that the septic tank may be leaking. Recommend having a leak test done to evaluate whether the tank is in fact leaking. COMPLIANCE STATUS: COMPLIANT ❑ NON -COMPLIANT ❑ SIGNATURE OF "ORC"