Loading...
HomeMy WebLinkAbout#651-final INSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: 651 Laboratory Name: Town of Ahoskie Inspection Type: Municipal Maintenance Inspector Name(s): Todd Crawford Inspection Date: August 18, 2010 Date Report Completed: August 23, 2010 Date Forwarded to Reviewer: August 23, 2010 Reviewed by: Jeff Adams Date Review Completed: August 23, 2010 Cover Letter to use: Insp. Initial X Insp. Reg. Insp. No Finding __ Insp. CP Unit Supervisor: Dana Satterwhite Date Received: August 23, 2010 Date Forwarded to Alberta: August 24, 2010 Date Mailed: August 24, 2010 _____________________________________________________________________ On-Site Inspection Report LABORATORY NAME: Town of Ahoskie ADDRESS: P. O. Box 767 Ahoskie, NC 27910 CERTIFICATE #: 651 DATE OF INSPECTION: August 18, 2010 TYPE OF INSPECTION: Municipal Maintenance AUDITOR(S): Todd Crawford LOCAL PERSON(S) CONTACTED: Amy Pierce I. INTRODUCTION: This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. II. GENERAL COMMENTS: The lab was generally clean and well organized. All equipment appeared well maintained. Finding C is a new requirement policy since the last inspection. III. FINDINGS, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS: Quality Control A. Finding: An inconsistency was noted between the Standard Operating Procedures (SOPs) and laboratory practices. The analyst stated that the Relative Percent Difference (RPD) acceptance criterion for duplicates was set at 25%. The SOPs for Fecal Coliform and Residual Chlorine listed the duplicate RPD criterion as 35%. The SOP for pH did not list duplicate acceptance criteria. Requirement: Each laboratory shall develop and maintain a document outlining the analytical quality control practices used for the parameters included in their certification. Supporting records shall be maintained as evidence that these practices are being effectively carried out. Ref: 15A NCAC 2H .0805 (a) (7). Comment: The Analytical Quality Control document had just been reviewed in February of 2010. Comment: The Analytical Quality Control document must include standard operating procedures. Since there are often changes in technology or options within a particular method that are not covered in published references, the laboratory SOP is the #651 Town of Ahoskie Page 2 prescriptive reference document that describes a laboratory’s analytical procedure in such detail that an experienced analyst unfamiliar with the method can obtain acceptable results and meet documentation requirements. This document is intended to be the reference for analysts performing the specified test procedure. Standard operating procedures must be developed which describe in detail how a method is performed in that particular laboratory and they must be reviewed periodically for accuracy. They must be revised any time a change in analytical procedure is made. Documentation B. Finding: The in-situ analysis times for pH and temperature of monitoring well samples are not being documented. Requirement: A record of date collected, time collected, sample collector, and use of proper preservatives must be maintained. Each sample must clearly indicate the State of North Carolina collection site on all record transcriptions. Ref: 15A NCAC 2H .0805 (a) (7) (M). Comment: Times for effluent samples were being documented. C. Finding: The laboratory needs to increase the documentation of purchased materials and reagents. Requirement: All chemicals, reagents, standards and consumables used by the laboratory must have the following information documented: Date received, Date Opened (in use), Vendor, Lot Number, and Expiration Date (where specified). A system (e.g., traceable identifiers) must be in place that links standard/reagent preparation information to analytical batches in which the solutions are used. Documentation of solution preparation must include the analyst’s initials, date of preparation, the volume or weight of standard(s) used, the solvent and final volume of the solution. This information as well as the vendor and/or manufacturer, lot number, and expiration date must be retained for primary standards, chemicals, reagents, and materials used for a period of five years. Consumable materials such as pH buffers, lots of pre-made standards and/or media, solids and bacteria filters, etc. are included in this requirement. Ref: North Carolina Wastewater/Groundwater Laboratory Certification Policy. Comment: Documentation of standards and reagents prepared in the lab is being maintained. The finding applies only to purchased reagents and consumable materials. IV. PAPER TRAIL INVESTIGATION: No paper trail performed. V. CONCLUSIONS: Correcting the above-cited findings will help this lab to produce quality data and meet certification requirements. The inspector would like to thank the staff for its assistance during the inspection and data review process. Please respond to all findings. Report prepared by: Todd Crawford Date: August 23, 2010 Report reviewed by: Jeff Adams Date: August 23, 2010