HomeMy WebLinkAbout#5442_07_2014_FINALINSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: Laboratory Name: Inspection Type: Inspector Name(s): Inspection Date: Date Report Completed: Date Forwarded to Reviewer: Reviewed by: Date Review Completed: Cover Letter to use: Unit Supervisor/Chemist III: Date Received: Date Forwarded to Linda: Date Mailed: 5442 Blowing Rock WWTP Field Maintenance Jason Smith July 8, 2014 August 7, 2014 August 8, 2014 Tonja Springer August 8, 2014 ❑ Insp. Initial ❑ Insp. Reg. ❑ Insp. No Finding ❑ Insp. CP E Corrected Gary Francies 8/8/2014 8/15/2014 NCDENR # I� #• # #1 i I" ! # r Pat McCrory Governor August 18, 2014 5442 Mr. Mark Griffin Blowing Rock WWTP P.O. Box 2225 Blowing Rock, NC 28605 John E, Skvarla, III Secretary Subject: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Mr. Griffin: Enclosed is a report for the inspection performed on July 7, 2014 by Jason Smith. No findings are cited in this report, a response is not required. We appreciate the fine job you and your staff are doing. As a certification requirement, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If wish to obtain an electronic copy of this report by email or if you have questions or need additional information, please contact us at (828) 296-4677. Attachment cc: Master File Jason Smith Sincerely, Gary Francies, Technical Assistance/Compliance Specialist Division of Water Resources Water Sciences Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Pail Service Center, Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road, Raleigh, North Carolina 27607 Phone, 919-733-3908 t FAX: 919-733-6241 Internet: www.dwg€ab.org An Equal Opportunity ! Affirmative Action Employer LABORATORY NAME: NPDES PERMIT #: ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: AUDITOR(S): LOCAL PERSON(S) CONTACTED: I. INTRODUCTION: On -Site Inspection Report Blowing Rock WWTP NCO027286 P.O. Box 2225 Blowing Rock, NC 28605 5442 July 7, 2014 Field Maintenance Jason Smith Mark Griffin and Marshall Townsend This laboratory was inspected by a representative of the North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) program to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. IL GENERAL COMMENTS: The laboratory was clean and well organized. The facility has all the equipment necessary to perform the analyses. Proficiency Testing (PT) samples for the 2014 proficiency testing calendar year have not yet been analyzed. The laboratory is reminded that these results must be submitted to this office directly from the vendor by September 30, 2014. Current quality assurance policies for Field Laboratories and approved procedures for the analysis of the facility's currently certified parameters were provided at the time of the inspection. Contracted analyses are performed by Water Tech Labs, Inc. (Certification #50). III. FINDINGS REQUIREMENTS COMMENTS AND RECOMMENDATIONS: Documentation Comment: Some instances of using correction fluid for errors were noted. The Quality Assurance Policies for Field Laboratories document states: All documentation errors must be corrected by drawing a single line through the error so that the original entry remains legible. Entries shall not be obliterated by erasures or markings. Wite-Out®, correction tape or similar products designed to obliterate documentation are not to be used. Write the correction adjacent to the error. The correction must be initialed by the responsible individual and the date of change documented. All data and log entries must be written in indelible ink. Pencil entries are not acceptable. Notification of acceptable corrective action (i.e., a statement that correction fluid will no longer be used and that error corrections will now be performed with a single line, initialed, and dated) was received by email on July 10, 2014. No further response is necessary for this finding. Page 2 #5442 Blowing Rock WWT P Comment: The laboratory needed to increase the documentation of purchased materials and reagents. The Quality Assurance Policies for Field Laboratories document states: All chemicals, reagents, standards and consumables used by the laboratory must have the following information documented: Date Received, Date Opened (in use), Vendor, Lot Number, and Expiration Date. Consumable materials such as pH buffers and lots of pre -made standards are included in this requirement. This requirement is a new policy that has been implemented by our program since the last inspection. Notification of acceptable corrective action (i.e., the example traceability log provided by the auditor has been put into use) was received by email on July 10, 2014. No further response is necessary for this finding. Comment: Instrument identification was not documented on the benchsheets. The NC WW/GW LC Approved Procedure for the Analysis of Total Residual Chlorine, NC WW/GW LC Approved Procedure for the Analysis of Temperature, NC WW/GW LC Approved Procedure for the Analysis of Dissolved Oxygen, and NC WW/GW LC Approved Procedure for the Analysis of pH documents state: The following must be documented in indelible ink whenever sample analysis is performed: Instrument identification. This requirement is a new policy that has been implemented by our program since the last inspection. Notification of acceptable corrective action (i.e., instrument identification has been added to all benchsheets) was received by email on July 10, 2014. No further response is necessary for this finding. Total Residual Chlorine — Standard Methods, 4500 CI G-2000 Comment: Values were reported below the established reporting limit of 20 pg/L. The NC WW/GW LC Approved Procedure for the Analysis of Total Residual Chlorine document states: The concentrations of the calibration standards must bracket the concentrations of the samples analyzed. One of the standards must have a concentration equal to or below the lower reporting concentration for Total Residual Chlorine. The lower reporting limit must be less than or equal to the permit limit. Notification of acceptable corrective action (i.e., values below 20 pg/L will now be reported as <20 pg/L) was received by email on July 10, 2014. No further response is necessary for this finding. IV. PAPER TRAIL INVESTIGATION: The paper trail consisted of comparing field testing records and contract lab reports to Discharge Monitoring Reports (DMRs) submitted to the North Carolina Division of Water Resources. Data were reviewed for the Blowing Rock WWTP (NPDES permit #NC0027286) for March, April and June, 2014. No transcription errors were detected. The facility appears to be doing a good job of accurately transcribing data. V. CONCLUSIONS: All findings noted during the inspection were adequately addressed prior to the completion of this report. The inspector would like to thank the staff for its assistance during the inspection and data review process. No response is required. Report prepared by: Jason Smith Date: August 7, 2014 Report reviewed by: Tonja Springer Date: August 8, 2014