Loading...
HomeMy WebLinkAbout#5554 - 9 - 2011 - FINALINSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: Laboratory Name: Inspection Type: Inspector Name(s): Inspection Date: Date Report Completed: Date Forwarded to Reviewer: Reviewed by: 5554 JR's Wastewater Service Field Commercial Initial Chet Whiting, September 9, 2011 September 30, 2011 September 30, 2011 Jeff Adams Date Review Completed: September 30, 2011 Cover Letter to use: X Insp. Initial _ Insp. Reg. _ Insp. No Finding _ Insp. CP _ Corrected Unit Supervisor: Date Received: Date Forwarded to Linda: Date Mailed: Gary Francies 10/5/2011 10/10/2011 Goveris - 5554 Mr. John Ritchie JR's Wastewater Service 1250 Leonard Rd Salisbury, NC 28146 FFWA AJ4 NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Coleen H. Sullins Director October 10, 2011 SUBJECT: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Initial Inspection Dear Mr. Ritchie: Enclosed is a report for the inspection performed on September 9, 2011 by Chet Whiting. Where finding(s) are cited in this report, a response is required. Within thirty days of receipt, please supply this office with a written item for item description of how these finding(s) were corrected. If the finding(s) cited in the enclosed report are not corrected, enforcement actions may be recommended. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email, or if you have questions or need additional information please contact me at 828-296-4677. Sincerely, Gary Francies Unit Supervisor Laboratory Section CC: Chet Whiting Gary Francies Master File DENR DWQ Laboratory Section NC Wastewater/Groundwater Laboratory Certification Branch �TQne 1623 Mail Service Center, Raleigh, North Carolina 27699-1623 1� orth oh s. Location: 4405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Phone: 919-733-3908 \ FAX: 919-733-6241 Naturally Internet: www.dwglab.org An Equal Opportunity \ Affirmative Action Employer Customer Service: 1-877-623-6748 www.ncwaterquality.org LABORATORY NAME: 9 CERTIFICATE #: AUDITOR(S): LOCAL PERSON(S) CONTACTED: INTRODUCTION: On -Site Inspection Report JR's Wastewater Service 1250 Leonard Rd Salisbury, NC 28146 5554 September 9, 2011 Field Commercial Initial Chet Whiting John Ritchie This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. II. GENERAL COMMENTS: Equipment, reagents and supporting documentation were bought to the Mooresville Regional Office for Inspection. Equipment was neatly and securely packed and was easy to access for inspection. Supporting documentation was neat and well ordered and easy to review. Bench sheets were good and contained some elements of traceability. A. Finding: Proficiency testing (PT) samples are not documented in the same manner as environmental samples. Requirement: The analysis of PT samples is designed to evaluate the entire process used to routinely report environmental analytical results. Therefore, PT samples must be analyzed and the process documented in the same manner as environmental samples. Ref: Quality Assurance Policies for Field Laboratories. Comment: PT data is currently recorded on the document submitted to the vendor, but is not being recorded on the benchsheet along with other samples. B. Finding: Data that does not meet all quality control requirements is not qualified on the Discharge Monitoring Report (DMR). Requirement: When quality control (QC) failures occur, the laboratory must attempt to determine the source of the problem and must apply corrective action. Part of the corrective action is notification to the end user. If data qualifiers are used to qualify samples not meeting QC requirements, the data may not be useable for the intended purposes. It is the responsibility of the laboratory to provide the client or end -user of the data with sufficient information to IA Page 2 #5554 JR's Wastewater Service determine the usability of the qualified data. Where applicable, a notation must be made on the Discharge Monitoring Report (DMR) form, in the comment section or on a separate sheet attached to the DMR form, when any required sample quality control does not meet specified criteria and another sample cannot be obtained. Ref: Quality Assurance Policies for Field Laboratories. C. Finding: The laboratory needs to increase the documentation of purchased materials and reagents, as well as, documentation of standards and reagents prepared in the laboratory. Requirement: All chemicals, reagents, standards and consumables used by the laboratory must have the following information documented: Date Received, Date Opened (in use), Vendor, Lot Number, and Expiration Date. A system (e.g., traceable identifiers) must be in place that links standard/reagent preparation information to analytical batches in which the solutions are used. Documentation of solution preparation must include the analyst's initials, date of preparation, the volume or weight of standard(s) used, the solvent and final volume of the solution. This information as well as the vendor and/or manufacturer, lot number, and expiration date must be retained for chemicals, reagents, standards and consumables used for a period of five years. Consumable materials such as pH buffers and lots of pre -made standards are included in this requirement. Ref: Quality Assurance Policies for Field Laboratories. Dissolved Oxygen — Standard Methods, 18 Ih Edition, 4500 0 G D. Finding: The temperature sensing device on the, Dissolved Oxygen meter had been calibrated against an NIST certified or traceable thermometer annually (every 12 months) however the correction was not posted. Requirement: Document the serial number and manufacturer of the NIST thermometer that was used in the comparison. Document any correction that applies (even if zero)) on both the meter and on a separate sheet to be filed. Ref: Technical Assistance for Field Analysis of Dissolved Oxygen The paper trail consisted of comparing field testing records and contract lab reports to Discharge Monitoring Reports (DMRs) submitted to the North Carolina Division of Water Quality. Data for NPDES# NC0041718 was reviewed for May, June and July, 2011. No transcription errors were detected. The facility appears to be doing a good job of accurately transcribing data. Correcting the above -cited findings will help this la requirements. The inspector would like to thank the data review process. Please respond to all findings. Report prepared by: Chet Whiting Report reviewed by: Jeff Adams b to produce quality data and meet certification staff for its assistance during the inspection and Date: September 30, 2011 Date: September 30, 2011