HomeMy WebLinkAbout#5582_07_2012_FINALINSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #. Laboratory Name: Inspection Type: Inspector Name(s): Inspection Date: Date Report Completed: Date Forwarded to Reviewer: Reviewed Uy: Date Review Completed: 5582 Belhaven Water Treatment Facility Field Initial Nick Jones and Gary Francies July 11, 2012 August 1, 2012 August 1, 2012 T odd Crawford August 3, 2012 Cover Letter to use: X Insp. Initial _ Insp. Reg. _ Insp. No Finding _ Insp. CP _ Corrected Unit Supervisor: Gary Francies Date Received: 8/16/2012 Date Forwarded to Linda: 9/5/2012 Date Mailed: i ENRD North Carolina a Department Environment and Natural Resources Beverly Eaves Perdue Governor 5582 Mr. Sonny Grant Belhaven Water Treatment Facility P.O. Box 220 Belhaven, NC 27810 Division of Water Quality Charles Wakild, P. E. Director September 5, 2012 Dee Freeman Secretary Subject: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Mr. Grant: Enclosed is a report for the inspection performed on July 11, 2012 by Nick Jones and myself. I apologize for the delay in getting this report to you. Where finding(s) are cited in this report, a response is required. Within thirty days of receipt, please supply this office with a written item for item description of how these finding(s) were corrected. If the finding(s) cited in the enclosed report are not corrected, enforcement actions may be recommended. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email or if you have questions or need additional information, please contact us at 828-296-4677. Sincerely, Gary Francies Certification Unit Supervisor Laboratory Section Enclosure cc: Nick Jones Master File DENR DWO Laboratory Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center, Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Phone: 919-733-3908 \ FAX: 919-733-6241 Internet: www.dwglab.org One North.Carolina Naturally An Equal Opportunity \ Affirmative Action Employer LABORATORY NAME: NPDES PERMIT #: ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: AUDITOR(S): LOCAL PERSON(S) CONTACTED: 1. INTRODUCTION: •' •- • -•• Belhaven Water Treatment Facility NC0086584 P.O. Box 220 Belhaven, NC 27810 5582 July 11, 2012 Field Initial Nick Jones and Gary Francies Sonny Grant This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. 11. GENERAL COMMENTS: The laboratory was clean and well organized. The facility has all the equipment necessary to perform the analyses. Benchsheets are well designed, easy to follow and concise. Records are well organized and easy to retrieve. Proficiency Testing (PT) samples have been analyzed for the 2012 proficiency testing calendar year and graded results were 100% acceptable. Contract analyses are performed by Environment 1, Inc. (Cent # 10). III. FINDINGS REQUIREMENTS COMMENTS AND RECOMMENDATIONS: Documentation A. Finding: The laboratory needs to increase the documentation of purchased materials and reagents. Requirement: All chemicals, reagents, standards and consumables used by the laboratory must have the following information documented: Date Received, Date Opened (in use), Vendor, Lot Number, and Expiration Date. A system (e.g., traceable identifiers) must be in place that links standard/reagent preparation information to analytical batches in which the solutions are used. Documentation of solution preparation must include the analyst's initials, date of preparation, the volume or weight of standard(s) used, the solvent and final volume of the solution. This information as well as the vendor and/or manufacturer, lot number, Page 3 #5582 Belhaven WTP and expiration date must be retained for chemicals, reagents, standards and consumables used for a period of five years. Consumable materials such as pH buffers and lots of pre -made standards are included in this requirement. Ref: Quality Assurance Policies for Field Laboratories. B. Finding: The laboratory is not documenting Proficiency Testing (PT) sample analyses in the same manner as environmental samples. Requirement: All PT sample analyses must be recorded in the daily analysis records as for any environmental sample. This serves as the permanent laboratory record. Ref: Proficiency Testing Requirements, February 20, 2012, Revision 1.2. Comment: The analysis of PT samples is designed to evaluate the entire process used to routinely report environmental analytical results; therefore, PT samples must be analyzed and the process documented in the same manner as environmental samples. PH — Standard Methods, 2u'h Edition, 4500-H+ B Comment: Values were reported that exceed the method specified accuracy (0.1 units) for this analysis. Standard Methods, 4500 H+ B-2000, (6) states in part: However, ± 0.1 pH unit represents the limit of accuracy under normal conditions, especially for measurement of water and poorly buffered solutions. For this reason, report pH values to the nearest 0.1 pH unit. Acceptable corrective action [i.e., the analyst updated the digital (Excel spreadsheet) Discharge Monitoring Report (DMR) so that pH results would be reported to 0.1 units]. was demonstrated during the inspection. No further response is necessary for this finding. C. Finding: The laboratory is not documenting the result of the post calibration buffer check. Requirement: The following must be documented whenever sample analysis is performed. 6. Value obtained for check buffer: Ref: Approved Procedure for Field Analysis of pH IV. PAPER TRAIL INVESTIGATION: The paper trail consisted of comparing field testing records and contract lab reports to DMRs submitted to the North Carolina Division of Water Quality. Data were reviewed for January, February, March and April, 2012. The following error was noted: Date Parameter Location Value on Benchsheet Value on DMR 4/24/12 Dissolved Oxygen Effluent 6.83 mg/L 4.83 mg/L In order to avoid questions of legality, it is recommended that you contact the appropriate Regional Office for guidance as to whether an amended Discharge Page 4 #5582 Belhaven WTP Monitoring Report will be required. A copy of this report will be made available to the Regional Office. It appears the facility is doing a good job of accurately transcribing data. V. CONCLUSIONS: Correcting the above -cited findings will help this lab to produce quality data and meet certification requirements. The inspector would like to thank the staff for its assistance during the inspection and data review process. Please respond to all findings. Report prepared by: Nick Jones Date: August 1, 2012 Report reviewed by: Todd Crawford Date: August 3, 2012