HomeMy WebLinkAbout#5021 - 05 - 2012 - FINALINSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #. 5021 Laboratory Name: Clearwater Services Inspection Type: Field Commercial Maintenance Inspector Name(s): Jason Smith Inspection Date: Deborah Bradley Date Report Completed: June 1, 2012 Date Forwarded to Reviewer: June 4, 2012 Reviewed by: Chet Whiting Date Review Completed: June 6 2012 Cover Letter to use: _ Insp. Initial _ Insp. Reg. _ Insp. No Finding _ Insp. CP X Corrected Unit Supervisor: Gary Francies Date Received: 6/6/2012 Date Forwarded to Linda: 6/7/2012 Date Mailed: 6/8/2012 Ic xkv-SY-TA lia NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Governor 5021 Ms. Deborah Bradley Clearwater Services 2225 E NC 108 Hwy Columbus, NC 28722 Charles Wakild, P. E. Director June 7, 2012 Dee Freeman Secretary SUBJECT: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Ms. Bradley: Enclosed is a report for the inspection performed on May 17, 2012 by Jason Smith. Since the finding(s) cited during the inspection were all corrected prior to the completion of the enclosed report, a response is not required. The staff is commended for taking the initiative in correcting the findings in such a timely manner. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by electronic main, or if you have questions or need additional information please contact me at 828-296-4677. Sincerely, c6zr�e Gary Francies Certification Unit Supervisor Laboratory Section Enclosure CC: Jason Smith Master File DENR DWO Laboratory Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center, Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Phone: 919-733-3908 \ FAX: 919-733-6241 Internet: www.dwglab.org One NofthCarolina Naturally An Equal Opportunity \ Affirmative Action Employer LABORATORY NAME: NPDES PERMIT #: ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: AUDITOR(S): LOCAL PERSON(S) CONTACTED: INTRODUCTION: On -Site Inspection Report Clearwater Services NCO033552 2225 E NC 108 Hwy Columbus, NC 28722 5021 May 17, 2012 Field Commercial Maintenance Jason Smith Deborah Bradley This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. The laboratory has all the equipment necessary to perform the analyses and records are well organized and easy to retrieve. The laboratory has been proactive in keeping up with updates and changes required by this program. III. FINDINGS, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS: Proficiency Testing Comment: The laboratory was not documenting Proficiency Testing (PT) samples in the same manner as environmental samples (i.e., on a benchsheet). The Quality Assurance Policies for Field Labs document states: The analysis of PT samples is designed to evaluate the entire process used to routinely report environmental analytical results. Therefore, PT samples must be analyzed and the process documented in the same manner as environmental samples. This requirement is a new policy that has been implemented by our program since the last inspection. Notification of acceptable corrective action (i.e., PT samples will be documented in the same manner as environmental samples) was received by email on June 1, 2012. No further response is necessary for this finding. Comment: The laboratory was not documenting the preparation of PT samples. The Proficiency Testing Requirements document, February 20, 2012, Revision 1.2. states: PT samples received as ampules must be diluted according to the PT provider's instructions. The preparation of PT samples must be documented in a traceable log or other traceable format. The diluted PT sample becomes a routine environmental sample and is added to a routine sample batch for analysis. This requirement is a new policy that has been implemented by our program since the last inspection. Notification of acceptable corrective action (i.e., PT sample preparation will be documented) was received by email on June 1, 2012. No further response is necessary for this finding. Page 2 #5021 Clearwater Services Total Residual Chlorine — Standard Methods, 19th Edition, 4500 Cl G Comment: The curve was not verified at a concentration below the facilities permit limit of 17 ,ug/L. The meter is used by this laboratory (at Polk Central Elementary) as well as the Tryon WWTP laboratory. Based upon a recommendation by the auditor during the Tryon WWTP inspection, the lowest standard concentration verified was 25,ug/L. When making this recommendation, the auditor was not aware of the lower permit limit at Polk Central Elementary. The Technical Assistance for Field Analysis of Total Residual Chlorine document states: The concentrations of the calibration standards must bracket the concentrations of the samples analyzed. One of the standards must have a concentration equal to or below the lower reporting concentration for Total Residual Chlorine. Demonstration of acceptable corrective action (i.e., an acceptable five point curve verification including a standard verification of 10 pg/L) was received by email on May 31, 2012. No further response is necessary for this finding. IV. PAPER TRAIL INVESTIGATION: The paper trail consisted of comparing field testing records and contract lab reports to Discharge Monitoring Reports (DMRs) submitted to the North Carolina Division of Water Quality. Data were reviewed for Polk Central Elementary (NPDES permit #NC0033552) for January, February, and March, 2102. No transcription errors were detected. The facility appears to be doing a good job of accurately transcribing data. V. CONCLUSIONS: All findings noted during the inspection were adequately addressed prior to the completion of this report. The inspector would like to thank the staff for its assistance during the inspection and data review process. No response is required. Report prepared by: Jason Smith Date: June 1, 2012 Report reviewed by: Chet Whiting Date: June 6, 2012