Loading...
HomeMy WebLinkAbout#5022_03_2015_FINALINSPECTION REPORT ROUTING SHEET To be attached to all inspection reports in-house only. Laboratory Cert. #: Laboratory Name: Inspection Type: Inspector Name(s): Inspection Date: Date Report Completed: Date Forwarded to Reviewer: Reviewed by: Date Review Completed: Cover Letter to use: Unit Supervisor/Chemist III: Date Received: Date Forwarded to Linda: Date Mailed: 5022 Town of Columbus WWTP Field Maintenance Jason Smith March 17, 2015 April 10, 2015 April 10, 2015 Nick Jones April 13, 2015 ❑ Insp. Initial ❑ Insp. No Finding ❑ Corrected ® Insp. Reg. ❑ Insp. CP ❑ Insp. Reg. Delay Gary Francies 4/13/2015 4/16/2015 4/16/15 Ic LABORATORY NAME: NPDES PERMIT #: ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: AUDITOR(S): On -Site Inspection Report Town of Columbus WWTP NCO021369 P.O. Box 146 Columbus, NC 28722 5022 March 17, 2015 Field Maintenance Jason Smith LOCAL PERSON(S) CONTACTED: Jason Phillips and Michael Fife INTRODUCTION: This laboratory was inspected by a representative of the North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) program to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. GENERAL COMMENTS: The facility has all the equipment necessary to perform the analyses. Proficiency Testing (PT) samples for the 2015 proficiency testing calendar year have not yet been analyzed. The laboratory is reminded that these results must be submitted to this office directly from the vendor by September 30, 2015. Contracted analyses are performed by Environmental Testing Solutions, Inc. (Certification #600). Current quality assurance policies for Field Laboratories and approved procedures for the analysis of the facility's currently certified parameters were provided at the time of the inspection. The previous Operator in Responsible Charge (ORC) left the facility in mid -February without training Mr. Phillips, the current ORC. Mr. Phillips requested an inspection to receive technical assistance and ensure compliance with certification rules. FINDINGS, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS: Documentation Comment: The laboratory was not reporting all data analyzed on the Discharge Monitoring Report (DMR). The North Carolina Administrative Code, 15A NCAC 2B .0506 (b) (3) (J) states: The results of all tests on the characteristics of the effluent, including but not limited to NPDES permit monitoring requirements, shall be reported on the monthly report forms. During the inspection and prior to the Paper Trail Investigation, Janet Cantwell with the Division of Water Resources called to notify the laboratory of permit monitoring frequency violations. Temperature, pH, Dissolved Oxygen (DO), and Total Residual Chlorine (TRC) were analyzed twice each week, but only one value for each parameter was reported each week. This occurred from June, 2014 through January, 2015. Laboratory personnel Page 2 #5022 Town of Columbus WWTP indicated to Ms. Cantwell and me that they will submit amended DMRs to address the unreported data. Although the February, 2015 DMR had not been submitted, all data was recorded on it as required prior to the inspection. No further response is necessary for this finding. A. Finding: The laboratory needs to increase the documentation of purchased materials and reagents. Requirement: All chemicals, reagents, standards and consumables used by the laboratory must have the following information documented: Date Received, Date Opened (in use), Vendor, Lot Number, and Expiration Date. Consumable materials such as pH buffers and lots of pre -made standards are included in this requirement. Ref: Quality Assurance Policies for Field Laboratories. Comment: An example traceability log was emailed to the facility on April 10, 2015. Implementation of this log will fulfill this requirement. B. Finding: Error corrections are not performed properly. Requirement: All documentation errors must be corrected by drawing a single line through the error so that the original entry remains legible. Entries shall not be obliterated by erasures or markings. Wite-Out®, correction tape or similar products designed to obliterate documentation are not to be used. Write the correction adjacent to the error. The correction must be initialed by the responsible individual and the date of change documented. All data and log entries must be written in indelible ink. Pencil entries are not acceptable. Ref: Quality Assurance Policies for Field Laboratories. Comment: Some error corrections were made by overwriting of the original data. Error corrections were not dated and initialed. Total Residual Chlorine — Standard Methods, 4500 CI G-2000 Dissolved Oxygen — Standard methods, 4500 O G-2001 PH — Standard Methods, 4500 H+ B-2000 PH — SW-846 9040 C PH — SW-846 9045 D Temperature — Standard methods, 2550 B-2000 C. Finding: The laboratory benchsheet was lacking pertinent data: Instrument identification. Requirement: The following must be documented in indelible ink whenever sample analysis is performed: Instrument Identification. Ref: NC WW/GW LC Approved Procedure for the Analysis of Total Residual Chlorine, NC WW/GW LC Approved Procedure for the Analysis of Dissolved Oxygen, NC WW/GW LC Approved Procedure for the Analysis of pH, NC WW/GW LC Approved Procedure for the Analysis of Temperature. D. Finding: The sample collector and analyst were not clearly identified. Requirement: Data pertinent to each analysis must be maintained for five years. Certified Data must consist of date collected, time collected, samples site, sample collector, and sample analysis time. The field benchsheets must provide a space for the signature of the analyst, and proper units of measure for all analyses. Ref: 15A NCAC 2H .0805 (g) (1). Page 3 #5022 Town of Columbus WWTP Comment: The initials for both operators on site were documented. This does not clearly show who collected and analyzed the samples. Comment: Initials are sufficient to fulfill the requirement of a signature. E. Finding: Sample collection and analysis times are not clearly documented. Requirement: Data pertinent to each analysis must be maintained for five years. Certified Data must consist of date collected, time collected, samples site, sample collector, and sample analysis time. The field benchsheets must provide a space for the signature of the analyst, and proper units of measure for all analyses. Ref: 15A NCAC 2H .0805 (g) (1). Comment: Only analysis time is currently documented. Temperature, pH, and Dissolved Oxygen (DO) are analyzed immediately. For these parameters, the benchsheet can be labeled It time" or a comment can be added to the benchsheet to indicate that samples are analyzed in situ. Total Residual Chlorine is collected and transported to the laboratory for analysis. In that case, collection and analysis times must be documented in order to demonstrate that the fifteen minute holding time is being met. pH — Standard Methods, 4500 H+ B-2000 F. Finding: Values were reported that exceed the method specified accuracy of 0.1 units. Requirement: By careful use of a laboratory pH meter with good electrodes, a precision of ±0.02 unit and an accuracy of ±0.05 unit can be achieved. However, ± 0.1 pH unit represents the limit of accuracy under normal conditions, especially for measurement of water and poorly buffered solutions. For this reason, report PH values to the nearest 0.1 pH unit. Ref: Standard Methods, 4500 H+ B-2000, (6). Recommendation: Although this is not required for sludge analyses (SW-846 9040 C and 9045 D), it is recommended that these results be rounded to the nearest 0.1 unit as well for consistency. PH — SW-846 9040 C PH — SW-846 9045 D G. Finding: Collection and analysis times were not documented for sludge analyses. Requirement: Data pertinent to each analysis must be maintained for five years. Certified Data must consist of date collected, time collected, samples site, sample collector, and sample analysis time. The field benchsheets must provide a space for the signature of the analyst, and proper units of measure for all analyses. Ref: 15A NCAC 2H .0805 (g) (1). H. Finding: Sludge sample measurements are not bracketed with calibration and check standard buffers. Requirement: Each instrument/electrode system must be calibrated at a minimum of two points that bracket the expected pH of the samples and are approximately three pH units or more apart. Ref: EPA SW-846 Test Methods for Evaluating Solid Waste, Physical/Chemical Methods; 3 Edition, Method 9040 C. Rev. 3. November 2004. Section 7.1.2. EPA SW-846 Test Methods for Evaluating Solid Waste, Physical/Chemical Methods; 3`d Edition, Method 9045 D. Rev. 4. November 2004. Section 7.1.2. Page 4 #5022 Town of Columbus VWVfP Comment: In order to meet this requirement for sludge samples, a standard at or above 12.45 Standard Units (SU) must be checked. IV. PAPER TRAIL INVESTIGATION: The paper trail consisted of comparing field testing records and contract lab reports to Discharge Monitoring Reports (DMRs) submitted to the North Carolina Division of Water Resources. Data were reviewed for the Town of Columbus WWTP (NPDES permit #NC0021369) for October, November, December, 2014, and February, 2015. No transcription errors were detected. The facility appears to be doing a good job of accurately transcribing data. V. CONCLUSIONS: Correcting the above -cited findings will help this lab to produce quality data and meet certification requirements. The inspector would like to thank the staff for its assistance during the inspection and data review process. Please respond to all findings and include an implementation date for each corrective action. Report prepared by: Jason Smith Date: April 10, 2015 Report reviewed by: Nick Jones Date: April 13, 2015 ' • fir% /':, NCDENF North Carolina Department of Environment and Natural Resources Pat McCrory Governor April 16, 2015 5022 Mr. Jason Phillips Town of Columbus WWTP P.O. Box 146 Columbus, NC 28722 Donald R. van der Vaart Secretary Subject: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Mr. Phillips: Enclosed is a report for the inspection performed on March 17, 2015 by Jason Smith. Where finding(s) are cited in this report, a response is required. Within thirty days of receipt, please supply this office with a written item for item description of how these finding(s) were corrected. 'If the finding(s) cited in the enclosed report are not corrected, enforcement actions may be recommended. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email or if you have questions or need additional information, please contact us at (828) 296-4677. Attachment cc: Master file Jason Smith Sincerely, Gary Francies, Technical Assistance/Compliance Specialist Division of Water Resources Water Sciences Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center; Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road, Raleigh, North Carolina 27607 Phone: 919-733-3908tFAX: 919-733-6241 Internet: wvvw.dwgiab.orq An Equal Opportunity\ Affirmative Action Employer