Loading...
HomeMy WebLinkAboutNCC230039_Site Plan or Location Map_20230106ZONE: R2o-MH Om - - m Q mZ ZONE: R2o-MH 18" FES INV: 52.0 W/5'Xlo'X12" ED ----OUTLET STRUCTURE (SEE DETAIL) / o-� YY / // CI#5 / M: 55.65 / o INV: 5L95/ / CI#6 / / RHGC INVESTMENTS INC. y M: 55.65 PARCEL #: o9-1182 c INV: 51.8 / z / DB 1590, PG 925 0 ZONE: HB 56.7 DUMPSTER PAD & ENCLOSURE (SEE DETAIL) 0 / y � 2 / C) O'REILLY C \ /// 2 AUTOMOTIVE PRIVATE PUMP STATION / STORES, INC. (PERMITTING BY OTHERS) PARCEL #: 09-1478 DB 1703, PG 646 5642 S NC HWY 41 ZONE: HB 0000 \ // 1C-1 No cot Aye z vzVIX 7 i / / / / / / / / / I WOOD, FRANCES B. & HUS WOOD, ROBERT A. DB 196o, PG 863 x ZONE: R2o-MH 0 N I w SDMH#2 56 NI RIM: 55.5 i "RIGHT TURN ONLY" SIGNS WATER TAP WITH METER & TOWN OF WALLACE APPROVED BACKFLOW PREVENTOR (BY OTHERS) ZONE: R2o-MH OVERALL PROJECT SITE DATA PIN #: ZONING: PROJECT ADDRESS CURRENT OWNERS: O IIAP N ROAD- TOTAL ACREAGE IN PROJECT BOUNDARY 2" WATER SERVICE (36" MIN. BURY) PROPOSED STORMWATER FACILITY TOB: 56.o NP: 52.4 FP: 53.9 BTM: \ i 18" FES INV: 51.3 W/5'Xlo'X12" ED / SDMH#1 \/ / RIM: 56.o INV: 51.4 v oCx / 0s CROWN COURT, LLC PARCEL #: 09-779 DB 16ti_q. PG 420 / / TO -E \ _ \ 1\DUMP STATION \ \ \ ACKAGE) \ \ \ PROPOSED ON -SITE IMPERVIOUS AREAS: CAR WASH SITE FUTURE OIL CHANGE SITE TOTAL: d_ 1 A T T A T A C1 T T C1 TT1T! T\ A 1T1 A_ 33o604829441 HB 110 MURRAY LN WALLACE, NC 28466 DAVID, G. PHILLIP 1516 DAWSON ST WILMINGTON NC 28401 ±86,383 S.F. (1.98 AC.) 39,000 S.F. 11,000 S.F. 50,000 S.F. (57.9%) MIN. LOT SIZE: lo,000 S.F. PROPOSED LOT SIZE: ±61,114 S.F. MIN. LOT WIDTH: 75' PROPOSED LOT WIDTH: 168.o8' PROPOSED USE: CAR WASH BUILDING SIZE: 3,515 S.F. (ROOF) BUILDING HEIGHT: t16'/1 STORY (40' MAX PER ZONING) BUILDING SETBACKS: FRONT: REQUIRED= 40' (20' to parking) PROPOSED= 6o' SIDE: REQUIRED= 15' PROPOSED= 48'L/85'R REAR: REQUIRED= 3o' To Res. PROPOSED= 191' PROPOSED ON -SITE IMPERVIOUS AREAS: BUILDING 3,515 S.F. CONCRETE PARKING AREA 26,500 S.F.*Includes entire shared easement drive* CONCRETE SIDEWALK, C. & G. 8,810 S.F. FUTURE 175 S.F. TOTAL: 39,000 S.F. (63.8%) PARKING REQUIRED: (1 space per 375 square feet of gross floor area.) MIN (3,515 GFA): 9 SPACES (1 H.C.) PARKING PROVIDED= /lTT "Ww A T !1T CITr T A T A _ 25 SPACES (2 H.C.) MIN. LOT SIZE: lo,000 S.F. PROPOSED LOT SIZE: ±25,269 S.F. MIN. LOT WIDTH: 75' PROPOSED LOT WIDTH: 186.56' PROPOSED ON -SITE IMPERVIOUS AREAS: FUTURE DEVELOPMENT 11,000 S.F. (43.5%) \ \ DEVELOPMENT NOTES: \ \ \ \ 1. ALL DEVELOPMENT SHALL BE IN ACCORDANCE WITH TOWN OF WALLACE ZONING ORDINANCE. \ \ \ \ 2. PROJECT SHALL COMPLY WITH ALL FEDERAL, STATE & TOWN OF WALLACE REGULATIONS. \ / FIRE & SAFETY NOTES: 1. PROPOSED BUILDING WILL NOT BE SPRINKLED 10' X 70' NCDOT \ \ / / 2. PARKING AND LANDSCAPING CANNOT BLOCK FIRE HYDRANTS. \SIGHT TRIANGLE \ / 3• ALL WEATHER ACCESS ROAD MUST BE MAINTAINED AROUND CONSTRUCTION SITE AT ALL TIMES. / / / / / UTILITY NOTES: PIT \ // 1 EXISTING WATER AND SANITARY SEWER SERVICES ARE CURRENTLY AVAILABLE TO THE SITE FROM TOWN OF 2" G.V. \\ �� - / WALLACE PUBLIC MAINS. / 2. ALL PROPOSED UTILITY SERVICES, SUCH AS ELECTRIC POWER, CATV, GAS & TELEPHONE SHALL BE INSTALLED ��ALL UNDERGROUND. c EA / 3. ALL WATER & SEWER UTILITIES TO BE INSTALLED PER TOWN OF WALLACE TECHNICAL SPECIFICATIONS & � // ' STANDARDS. 4. THE CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF EXISTING UTILITIES DURING 0v �� / CONSTRUCTION. CALL NC811 AT 811 OR 1-800-632-4949• CONTRACTOR IS RESPONSIBLE FOR THE REPAIR AND / Avv REPLACEMENT OF ANY UTILITIES, CURB &GUTTER, PAVEMENT, ETC. THAT MAY BE BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OR WORKMANSHIP FOUND IN THE ORIGINAL ITEM. 5. SOLID WASTE DISPOSAL BY PRIVATE DUMPSTER SERVICE. / GENERAL TRAFFIC NOTES: 15" PPES # 1 / 1. ALL TRAFFIC CONTROL SIGNS AND PAVEMENT MARKINGS OFF THE R/W TO BE MAINTAINED BY THE PROPERTY \INV: 53 65 / i OWNER IN ACCORDANCE WITH MUTCD STANDARDS. / y IN V' 53.65 ED 2. ALL PAVEMENT MARKINGS IN PUBLIC RIGHTS -OF -WAY AND FOR DRIVEWAYS ARE TO BE THERMOPLASTIC AND MEET NCDOT STANDARDS. \ NCDOT SDMH#1 3. ALL SIGNS AND PAVEMENT MARKINGS OFF RIGHT OF WAY ARE TO MEET/BE MAINTAINED TO MUTCD (MANUAL / gp� / 11,E ON UNIFORM TRAFFIC CONTROL DEVICES) STANDARDS. RIM' 56'5 / O 7. ALL PROPOSED VEGETATION WITHIN SIGHT TRIANGLES SHALL NOT INTERFERE WITH CLEAR VISUAL SIGHT p INV' 53.8 I1 ��g4 LINES FROM 30" TO lo'. / 44 y�g NCDOT STRIPING LEGEND 4 \\ TA= THERMOPLASTIC (4"WHITE go MIL) EDGELINE \ TD= THERMOPLASTIC (4" WHITE 120 MIL) MINI SKIP 3'-9' SPACING NCDOT NOTES: 1. CONTRACTOR SHALL COMPLY WITH NCDOT STANDARD SPECIFICATIONS FOR PAVEMENT MARKINGS. STD \1o' X lo' RECEIVING PIT 1205.05 'ER & SAW -CUT AND RESTORE \ 2. CONTRACTOR SHALL CONTACT TRAFFIC SERVICES (910-341-2000) FOR STRIPING LAYOUT. ED ASPHALT TO EX. CONDITIONS. \ \ 3• CONTRACTOR SHALL COMPLY WITH USDOT PART VI STANDARDS AND GUIDES FOR TRAFFIC CONTROLS FOR \ \ TIE TO EX. SSFM HIGHWAY MAINTENANCE. \ \ W/ 2" T.S.&V. \ MILL 1' IN FROM EXISTING TRAVEL LANE (SEE PLAN VIEW 5.5" B25.DC NOTE: 1. PAVEMENT MARKINGS SHALL BE DONE BY CONTRACTOR TO NCDOT STANDARDS ±37' 2' PAVED SHOULDER U GRASSED 11III=III= -III-III O NCDOT PAVEMENT WIDENING SECTION R/W LEGEND PROPERTYLINE - - ADJOINERS RIGHT OF WAY - - - - - - - - - EX. EDGE OF PAVEMENT - - - - - - - - - BUILDING SETBACKS EXISTING DITCH W EXISTING WATER MAIN FM EXISTING SANITARY SEWER FORCE MAIN W WATER LINE SS SANITARY SEWER LINE FM SANITARY SEWER FORCE MAIN EXISTING FIRE HYDRANT RUNOFF DIRECTION 50.35 SPOT ELEVATION ENERGY DISSIPATOR CURB INLET ■ DROPINLET STORM DRAIN MANHOLE PROPOSED PAVEMENT WIDENING PROPOSED MILL & OVERLAY 30' 15 o' 30' 6o' Scale: 1"=30' VICINITY MAP (NOT TO SCALE): � SUMMER RIDGE DR x SITE z �c al a ovv�cgv� o w h w O U bA 50, V1 �D O d a ct ct kn Q U °° ct o v z W OJI a b U u .ct CLIENT INFORMATION: Rinse & Roll, LLC 943 Baldwin Park Dr. Wilmington, NC 28411 DRAWN: JAE SHEET SIZE: 24 X 36 CHECKED: CDC DATE: 11/16/2022 APPROVED: CDC SCALE: 1" = 30' PROJECT NUMBER: 2022-014 DRAWING NUMBER: C-1 2 OF 6 NTS