HomeMy WebLinkAboutSWA000178_Plansheet - Other_2022121784 z SITE 0 PROPOSED 0 2" THREADED -TAP -- � WEDDINGTON _� - - - WITH 2" GATE VALVE ° as VICINITY MAP RD - - - - - _ - _ _ 00.071 (NOT TO SCALE) - N65 3715" p A a Sam I o W T W W a a ° a PROPOSED 2" PRO 0 6" GATE VALVE ° ° PROPOSED 6" BLOWOFF ASSEMBLY - _ 6" CAP RESTRAINED JOINT _ o _ _AND ---------RP�SEE BEL OW)__ INSET (WATER MAIN TERMINATION) SCALE: 1" = 20' GENERAL NOTES: 1. THIS PLAN IS NOT A CERTIFIED SURVEY. BOUNDARY AND TOPOGRAPHIC INFORMATION WAS OBTAINED FROM A SURVEY PERFORMED BY "CAROLINA SURVEYORS", DATED OCTOBER 20, 2020. 2. ALL EXISTING UTILITY LOCATIONS ARE APPROXIMATE AND SHOULD BE FIELD -VERIFIED PRIOR TO CONSTRUCTION. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN. CONFLICTS BETWEEN EXISTING UTILITIES AND PROPOSED EXCAVATION SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 3. THE CONTRACTOR SHALL PROVIDE A MINIMUM OF 48 HOURS NOTICE TO OWNER OR REPRESENTATIVE PRIOR TO INTERRUPTION OF ANY EXISTING UTILITY. 4. THE CONTRACTOR IS RESPONSIBLE FOR REPAIR AND/OR REPLACEMENT OF ANY UTILITIES DAMAGED DURING CONSTRUCTION. 5. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL NECESSARY PERMITS AND APPROVALS HAVE BEEN OBTAINED PRIOR TO CONSTRUCTION. THESE PERMITS AND APPROVALS MAY INCLUDE BUT ARE NOT LIMITED TO GRADING, DEMOLITION, ZONING, BUILDING, DRIVEWAY, DETENTION, SUBDIVISION, SPECIAL USE, SEWER AND WATER. 6. CONTACT THE APPROPRIATE UTILITY COMPANY TO RELOCATE ANY EXISTING UTILITY POLES. 7. TREES WITHIN THE ROAD RIGHT-OF-WAY ARE PROTECTED BY LAW. A PERMIT IS REQUIRED PRIOR TO THE REMOVAL OF ANY RIGHT-OF-WAY TREES. 8. ALL TREES OVER 8" IN DIAMETER WITHIN THE PROPERTY SETBACK(S) ARE PROTECTED. 9. BEFORE YOU DIG, STOP. CALL THE NORTH CAROLINA ONE -CALL CENTER AT 8-1-1. 10. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. NOW OR FORMERL Y L ONG DENNIS P 1 PID 09`3450`3 7 1 - - ZONED. RA -20 EXISTING UTILITY _/ 11 POLE 01 =1 u0 EXISTING OVERHEAD ELECTRIC (TYP.) EXISTING LEPHONE LINE (TYP.) 0 o_ 0 / / (STING UTILITY POLE (TYP.) (PRIVATE) MATERIAL SUMMARY: 4" PVC SANITARY SEWER LATERAL T.B.D. 4" DIAMETER PVC CLEANOUT T.B.D. WATER SERVICE LINE 910 L.F. IRRIGATION LINE T.B.D. - - - - - - - - - - 1 LOT 14 48,746 Q. FT. I UTILITY CONSTI UC ION PHASE 3 (LOTS yh 2 14)II ---------- - - - - -- I I I i 1 LOT 11 � I �---------------.-- ' ii I li--------------- it I -- - - - - - - - - - - - - - - -- II EI, 26,562 Q. FT. II-- - - - - - - - - - - - - - -- y I------------------�I EXISTING .GUY it I 1� LOT #13 �1 I i LOT #12 ,WIRE (TYP.) - 'li i li 49,115 SQ. FT. II I 134,413 SQ. FT. • ' II I 1i 11 ' I I i II II I � li - ' II ---=---=---- I II ,----------- - - ---- I 1 , 11 II-- - - - - - - - - - - - - - ' -'I '----------- - - - - - - II II 1 11 , II II II PROPOSED 1 I I I II ¢ II RESIDENCE I I I'-- - - = - - - - ' --------' II I-1 1 PROPOSED PROPOSED I I RESIDENCE 1 I PROPOSED 1 II 14 1 ' I RESIDENCE i RESIDENCE 1 ' I PROPOSED RESIDENCE PROPOSED I 1 PROPOSED 3/4" DUAL 1 i lk .. II 1 RESIDENCE - - - - - - I WATER PROPOSED 295' 0 6" ER METER (TYP.) JI • �° II I I I I �• . I I- - - _ - - (- ) 1 WATER MAIN EXTENSION -J ..�°P PROPOSED �170' OF 6" i - - - - - - - a • I1- - 1 I I. - la RAINED�JOINT PIPE I EXISTING METER _ .. % % % % % % % - - - - - - - - - - - - - -I TO BE ABANDONED 1 I% a i ......... .....,. r. U.C.P.W. UTILITY NOTES: 1. REFER TO UNION COUNTY SPECIFICATIONS, UNION COUNTY WATER & SEWER EXTENSION POLICY AND UNION COUNTY WATER & SEWER EXTENSION ORDINANCE 2. ALL WATER AND SEWER TAPS, MATERIALS AND INSTALLATION TO BE BY THE DEVELOPER. 3. ENGINEER TO CERTIFY THAT DESIGN HAS BEEN VERIFIED BY GROUND SURVEY 4. A UNION COUNTY PUBLIC WORKS' UTILITY RIGHT-OF-WAY SHALL EXIST ON ALL SANITARY SEWER LATERALS, WATER METERS, AND FIRE HYDRANTS. THE UTILITY RIGHT -OF WAY IS LOCATED 5 FEET ALL SIDES FROM THE CLEANOUT, WATER METER, OR FIRE HYDRANT TO THE PUBLIC OR PRIVATE ROAD RIGHT-OF-WAY. 5. THE PROPERTY OWNER SHALL NOT CONSTRUCT OR PERMIT CONSTRUCTION OR PLACEMENT OF ANY TYPE STRUCTURE, PLANT TREES, OR MAKE USE OF THE EASEMENT AREA IN ANY MANNER THAT WILL RESULT IN INTERFERENCE, INTERRUPTION, OR IMPEDIMENT OF UNION COUNTY PUBLIC WORKS EASEMENT AND INGRESS/EGRESS. 6. ONLY UCPW PERSONNEL WILL OPERATE THE ACTIVE VALVES WHICH INCLUDED THE TAPPING VALVE. 7. FIRE HYDRANT PLACEMENT (FIRE HYDRANTS SHALL BE PLACED A MINIMUM DISTANCE OF 6 FEET BACK OF CURB AND GUTTER SECTIONS AND BACK OF DITCH IN ROADWAY SECTIONS) & HAVE A CLEAR SPACE OF 5 FEET FROM ANY PERMANENT STRUCTURES. 8. METERS WILL NOT BE SET IF WATER METER BOXES, SEWER CLEAN -OUTS, VALVE BOXES OR THEIR APPURTENANCES ARE DAMAGED OR IMPROPERLY POSITIONED. 9. ALL 2" GATE VALVES SHALL BE COMPLIANT WITH AWWA C515 10. ALL 3" OR LARGER GATE VALVES SHALL BE COMPLIANT WITH AWWA C500 AND C509 11. ALL AIR RELEASE VALVES SHALL BE COMPLIANT WITH AWWA C512 12. VERIFICATION HAS BEEN MADE BY JONES CIVIL DESIGN THAT EACH LOT IS CAPABLE OF HAVING GRAVITY SEWER SERVICE TO THE CENTER OF THE LOT AT THE FRONT SETBACK 13. THE CONTRACTOR SHALL AT ALL TIMES PROVIDE AND MAINTAIN AMPLE MEANS AND EQUIPMENT WITH WHICH TO REMOVE AND PROPERLY DISPOSE OF ANY AND ALL WATER ENTERING THE EXCAVATION OR OTHER PARTS OF THE WORK AND KEEP ALL EXCAVATIONS DRY UNTIL SUCH TIME AS PIPE LAYING AND GRADING IS COMPLETED AND STRUCTURES TO BE BUILT THEREIN ARE COMPLETED. 14. NO WATER SHALL BE ALLOWED TO RISE AROUND THE PIPE IN UN-BACKFILLED TRENCHES NOR SHALL IT BE ALLOWED TO RISE OVER MASONRY UNTIL THE CONCRETE OR MORTAR HAS SET (MINIMUM 24 HOURS). ALL WATER PUMPED OR DRAINED FROM THE WORK SHALL BE DISPOSED OF IN SUCH A MANNER AS TO PREVENT SILTATION AND EROSION TO ADJACENT PROPERTY OR OTHER CONSTRUCTION. 15. IF WELL AND/OR SEPTIC SYSTEMS ARE ENCOUNTERED, THEN CONTACT DAVID FINLEY (704.283.3879) WITH ENVIRONMENTAL HEALTH FOR THEIR SEQUENCE OF EVENTS AND OTHER PERTINENT INFORMATION. U.C.P.W. SUPPLEMENTAL NOTES: 1. PROPOSED WATER SERVICE CONNECTION SHALL BE MADE TO THE EXISTING 6" WATERMAIN ON THE SOUTH SIDE OF WATKINS RD. 2. LOTS SHALL BE SERVICED WITH SEPTIC SYSTEMS. SEPTIC SYSTEMS SHALL DESIGNED BY OTHERS. DESIGN AND CONSTRUCTION OF SEPTIC SYSTEMS SHALL BE REVIEWED, APPROVED AND INSPECTED BY UNION COUNTY. 3. DUAL METERS ARE REQUIRED FOR DOMESTIC FLOW AND IRRIGATION. 4. IRRIGATION WILL NOT BE PROVIDED FOR THE COMMON OPEN SPACE AREAS. 5. CONSTRUCTION IS ANTICIPATED TO BEGIN DECEMBER 5, 2022. VERIFICATION NOTE: THIS DESIGN HAS BEEN FIELD VERIFIED BY A GROUND SURVEY CONDUCTED BY CAROLINA SURVEYORS, DATED: OCTOBER 20, 2020. NCDOT UTILITY NOTE: ALL FIXED OBJECTS THAT ARE NOT CONSIDERED BREAKAWAY MUST BE REMOVED FROM THE CLEAR RECOVERY ZONE (15' FROM THE EDGE OF PAVEMENT). CALL \o� BEFORE YOU DIG, KNOW WHAT'S BELOW IT'S THE LAW DEVELOPMENT DATA: DEVELOPER/OWNER: JR HOMES OF NC 8000 CORPORATE CENTER DRIVE, SUITE 100 CHARLOTTE, NC 28226 CONTACT: JIMMY RAY (704)-877-1 178 EMAIL: JimmyRay330Gmail.com ENGINEER OF RECORD: JONES CIVIL DESIGN, P.C. C. MATTHEW JONES, P.E. (704) 412-8523 EMAIL: Matt®JonesCivilDesign.com PROPOSED WATER USE: RESIDENTIAL, SINGLE-FAMILY AVERAGE DAILY (DOMESTIC) FLOW: 400 GPD (PER RESIDENCE) X 14 RESIDENCES = 5,600 GPD FIRE FLOW: ISO NFF (FOR RESIDENCES MORE THAN 30' APART) = 500 GPD AVERAGE DAILY (IRRIGATION) FLOW: 200 GPO (PER RESIDENCE) X 14 RESIDENCES = 2,800 GPD METERS SERVING THIS DEVELOPMENT: 14 PROPOSED DUAL METERS (3/4" DOMESTIC & IRRIGATION) 1 EXISTING METER (3/4" DOMESTIC) [TO BE ABANDONED U.C.W. STANDARDS] LEGEND SANITARY SEWER LINE - SS FORCE MAIN - FM WATER LINE W GAS LINE G CONDUIT (EMPTY PVC) C UGE UNDERGROUND ELECTRIC OHP OVERHEAD POWER FO/C FIBEROPTIC LINE TELECOM LINE T METAL FENCE WOODEN FENCE ° ° ° ° GUARDRAIL - SWALE / DITCH - - - - - - - STORM DRAIN PIPE (TOTAL) 13p, WATER OF s„ MgIN RESTRAINED JOINT 05 & BENRY PIPE ELBAS NECESSA STORM DRAIN 1 MIN. PIp 20 ON THE SS L T' „pF R J M DRAINN�ROSp„ SINg WATER MAIN & STORM DRAIN CROSSING (ISOMETRIC VIEW) 1 i I I I I I I I I I I I I l i I I i I I i I LOT #8 I LOT #7 1 LOT #6 LOT 5 52,687 SQ. FT. I 1 52,909 SQ. FT. 1 I I 53,077 SQ. FT. I I # I I I i I 48,910 SQ. FT. 1----------------I I------------------1 1 1-----------------I 1------------- I UTL,ITY CONSTRUCTION PHASE I 1' t (LOTS 5- 11 h � , I I M II h - I 11'-------------- II -------------- 1 M- --------- - - - - -- I I 1'=------------ --I -- --1 i 11_ _� I 1 I I 1 1 I 1 I I 1 I I PROPOSED I 1 PROPOSED I I I PROPOSED 1 PROPOSED RESIDENCE RESIDENCE i 1 I RESIDENCE 1 RESIDENCE I I 1 1 •1: I I I I 1• ;� •I• 8. W p 1------------- I I' I ------ -I I-------------� .------- Id PER U.C.W. STANDARDS I % % % % % % I. % % • • % % % % % % v i ; , PROPOSED %4 DUAL r 1 W ' 0 1 WATER METER (TYP.) I: 1 -- -- ------�--- - ...,.. ............ l • EXISTIING - -- - _ - - - .... %'% .... I TELEPHONE --PfI ---1- 1------_ - �° a --- EDE�TAL -- II• - i - - {I -o --_ d W. PROPOSED 6" GAT W T� C,4 1 W - '_ -6--CAP -Wff+l- 2�#READE2 O 1 x TAP 2" GATE VALVE AND-PR(iP6�ED 3/ - - - - - a W W " r , 2BLOW-OFF ASSEMBLY INV.=636.9 --- (SEE INSET, THIS SHEET) / o MAIN TAP (TYP.) / 1 DREAM PROPERTIES, LLC PID 09,3450,32L ZONED: RA -20 / / / / / / / / / / / / 1� RCMP, EXISTING MAILBOX ' INV.=637.6 EXISTING PROPOSED CONNECTION TO GRAVEL DRIVE EXISTING 6" VALVE (AFTER REMOVING EXISTING BLOWOFF) PROPOSED WATER MAIN DEFLECTION -UNDER THE STORM DRAIN PIPE/CULVERT (SEE ISOMETRIC VIEW, THIS SHEET) WATER MAIN - 15" RC PROPOSED -DUAL --MET SHALL BE AT LEAST 5' FROM EXISTING REES � EXISTING WATER SERVICE (TYP.) EXISTING GRAVEL / EXISTING WATER DRIVE METER (TYP.) / EXISTING MAILBOX INV.-641.8 BRYAN AND MELISSA MOORE / PID Dgn BONNIE F MARTIN ZONED., RA -20 PID 09.3450.32E ' ZONED: RA -20 / / / INV.=642.1 EXISTING MAILBOX 1 1 I 1 1 I 1 1 I 1 1 I 1 1 I 1 1 I 1 z WATKINS RD_ _ _ -�(S.R. 1163) PROPOSE _ D ` EXISTING MAIN TAP (TYP.) ° TELEPHONE 1 PEDESTAL 1 EXISTING EXISTING 1 A GRAVEL GRAVEL 1 a`\ DRIVE DRIVE 1 \ EXISTING 1 BOX 1 WATKINS D DA VID - PID 09,345032B BR)'AN AND MELISSA MOORS �� ZONED: RA-20 _- PID 09.345029C - ZONED: RA -20 ' " \0Z!. C� 0 40' SCALE: 1 " = 40' "IVIL EXINEERIM I LAND SOLUTIONS "FROM CONCEPTION TO COMPLETION" Z 'O n O N Ln 04 a0 N I N � U � Z W �O w Q w 0 Z U gc cn U Z > of U O cn _ c: H 0 rn? O 3 3 3 "VETERAN - OWNE1)" Engineer@JonesCivilDesign.com FIn�"I� GN ._, •F y. EA 3493 I ; c') Mq T T HO.�`'� FOR CON&PRIMON `o�,�N CgROC, °°°°°°° a JONES CIVIL a = g DESIGN, P.C. g z go C-3859 o g= � '° o 000 ° ° 1Q00 V) z w Z O O U Lj V Y 0 ul p J n Z Z 3: w w w O D U d J U F- O O W 2 Z p p Z ~ cj U U Z Z U Q of of w o w w w w a U U U U U Lj N N N N N Q N O N Ib p N N N 00 ^^ d NN C N N M O U m � o, ^ 4: N N N r O o I NLd m N m ij Q ij.i Z z w J � � o SHEET C2.1