HomeMy WebLinkAboutNCG100110_2022 DMR_20220801CERTIFIED MAIL, RETURN RECEIPT REQUESTED
Winston-Salem Regional Office
Attn: Central Files
450 West Hanes Mill Road, Suite 300,
Winston-Salem, NC 27105
RE: LKQ Greensboro
Greensboro, NC
Permit # NCG100110
2022 Second Quarter Discharge Monitoring Report
Dear Sir/Madam:
Please find attached the 2022 Second Quarter Stormwater Discharge Monitoring
Report (DMR) for the LKQ Greensboro facility located in Greensboro, North Carolina. This
submittal covers the reporting period April 1s' through June 301h, 2022. Approval for use of
the NC eDMR system has been applied for but has not been granted at this point. Please call
me at (912) 313-2720 or Mr. Brandon Walsh at 615-477-9833 if you have any comments,
questions, or concerns about the information presented in this submittal.
Sincerely,
�Z �Z4�0
Waldemar Sanchez
Plant Manager
Attachment
NCDEQ Division of Energy, Mineral and land Resources
5tormwater Discharge Monitoring Report (DMR) Form for NCG100000
Used Motor Vehicles
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate D_E_MLR Regional Office.
Certificate of Coverage No. NCG10 0252
Person Collecting Samples: Waldemar Sanchez
Facility Name: LKQ Greensboro
Laboratory Name: Eurofins TestAmedca, Savannah
Facility County: Guilford
Laboratory Cert. No.: 490
Discharge during this period:
Yes
No (if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑� Yes No
If so, which Tier (1,11, or Ill)?
A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR Yes 0 No
Date Uploaded:
Analytical Monitoring Requirementsfor Outfalls with Industrial Activities— Benchmarks in (Red)
Parameter
Parameter
Outfall 001
outfall
Outfall
Outfall
Outfall
Code
N/A
Receiving Stream Class
B
N/A
Date Sample Collected MM/DD/YYYy
6/16/22
46529
24-Hour Rainfall in inches
1,7.3
C0530
TSS in mg/L (100 or 50*)
320
PH in standard units (6.0-9.0 FW,
00400
--
6.88.55W)
6.90
Chemical Oxygen Demand in mg/L
00340
(120)
100
Lead, total recoverable (as Pb) in
01051
mg/ L (0.07S FW, 0.22 SW)
0.089
Ethylene Glycol in mg/ L (any amount
77023
detected Tier One; 8,000 mg/L Tier
Two and Three)
13
00552
Non -Polar Oil & Grease in mg/L (15)
27.1
Estimated New Motor/Hydraulic Oil
NCOIL
Usage in al/month
5 -10
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of'
FW (Freshwater) SW (Saltwater)
Notes (optional):
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly respansible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false inform . n, iri �udingpossibility of fines and imprisonment for knowing violations."
14 Z4JT/ZOZ Z
Signature of Permittee or Del ividual Date
w xS.lwi.a r- A? /- j: ZO y- A/fz_569f
Email Address Phone Number