Loading...
HomeMy WebLinkAboutSWA000168_Plansheet C6.0 - Misc. Detail_20221103EASEMENT Rw I -I �R>:QuiR-loTAMMRSRU�­` I I I 1 I I 50'TAPER (REQUIRED FOR W- LESS THAN. 261. 30' MIN: _ ] ry 0-4i so 1�[aF7AVEi11° l6a ,-bF PAVEMENT NOTES Drainage easements may be rewired to accamadafe drainage beyond the -iighfwf--way: RECOMMENDED ROAD CONNECTION TO STATE MAINTAINED ROAD DETAIL R/W I I NOT TO SCALE rERRAnv MAx sLort SECTION AA LEVEL 2.1 ROWNG' '21 MOUNLAINOUS_s 1-10:1 RECOMMENDED CUL-DE-SAC DETAIL NOT TO SCALE 50' RIGHT OF WAY 10, SHOULDER PAVEMENT 0.02 10, PAVEMENT I 0.02 6' 6' SHOULDER DITCH I 0�_ I I ()�111111111111111 f— —� -n i 2'"7 fill- Ti--iTi- COMPACTED SUBGRADE - 98% STD MINIMUM PROCTOR OR AS RECOMMENDED PAVEMENT DESIGN BY THE GEOTECHNICAL ENGINEER. 2.5" S9.5 B SUBJECT TO STANDARDS OUTLINED 8" ABC ON PAGE 22-23 OF THE N.C. (TYPE B) SUBDIVISIONS ROADS MINIMUM CONSTRUCTION STANDARDS RESIDENTIAL COLLECTOR ROAD rt I (50' PUBLIC R/W - 20' EOP-EOP) 35' N.T.S. 6' 5' 4' JLDER I DITCH I DITCH 0.02 1 0.08 EASEMENT *NCDEQ REQUIRES ENGINEERING CALCULATIONS AND SOIL EVALUATION FOR PERMANENT SLOPE STABILIZATION FOR MAX SLOPE AT 2:1 3'• M MINIMUM 21 PAVEMENT DESIGN* SUBJECT TO STANDARDS OUTLINED 2.5" S9.5 B ON PAGE 22-23 OF THE N.C. 8" ABC SUBDIVISIONS ROADS MINIMUM *NCDEQ REQUIRES ENGINEERING CALCULATIONS (TYPE B) CONSTRUCTION STANDARDS AND SOIL EVALUATION FOR PERMANENT SLOPE STABILIZATION FOR MAX SLOPE AT 2:1 SYMMETRICAL CUL-DE-SAC (NO CURB AND GUTTER) TYPICAL SECTION N.T.S. RIGHT OF WAY EDGE OF TRAVEL LANE R W ROADWAY CENTERLINE EDGE OF TRAVEL LANE RIGHT OF WAY 9' MIN. J TO CBU 20' 25' 20' MIN. MIN. MIN. PAVED TURNOUT (PAVEMENT STRUCTURE O MATCH TRAVEL LANES) CONCRETE PAD FOR CBU (PER USPS) CBU (ACCESS FROM PAD) g g 7, TURNOUT 2' w w CBU O O 0 0 1-1 w w 02 02, CONCRETE PAD FOR CBU NOTE: SEE FIGURE 1 PAGE 39, "NCDOT SUBDIVISION ROADS MINIMUM CONSTRUCTION MAINTAIN RrW OFFSET STANDARDS JANUARY 2010" FOR LOCAL AND COLLECTOR ROAD DIMENSIONS. AROUND CBU TURNOUT CBU PLACEMENT FOR SHOULDER SECTION RESIDENTIAL SUBDIVISION STREET c TRASH CAN i NOT TO SCALE 4s: TER BOX UNIT SUBJECT TO USPS IIFICATIONS AND APPROVAL 3000 PSI CONCRETE PAD SPEED LIMIT SIGN. (TYP.) 10' SIDE YARD SETBACK I MAIL KIOSK 1"=20' 25' REAR YARD SETBACK BUILDING ENVELOPE 35' FRONT YARD SETBACK TYPICAL LOT SETBACK DETAIL 10' SIDE YARD SETBACK u") N 15' UTILITY — EASEMENT, (TYP.) (ONLY LOTS WITH SIDEWALK) 10x70 SIGHT DISTANCE TRIANGLE, (TYP.) G30'x40' SIGN RqN p EASEMENT (So, P� GR/FFO 'nVIq , BLIC RIGHT OF_ VA V Y - l o c I � M N R30' / / oa o / O CD M / rn R30' / 3 SM I I I /I / 30' STREETSCAPE BUFFER I / LANDSCAPE LEGEND 18 NPHi I I I / EVERGREEN HEDGE I I � I / I 0 O EVERGREEN SHRUB I / / 3 CF / / LARGE DECIDUOUS TREE 6AC 6AA / ENTRANCE 1"=30' LANDSCAPING PLANTING SCHEDULE: KEY QUANTITY BOTANICAL NAME COMMON NAME MINIMUM INSTALLED SIZE USE TREES SM 3 ACER SACCHARUM SUGAR MAPLE 6 FEET LARGE DECIDUOUS TREE LARGE SHRUBS (CONTINUOUS HEDGE) NPH 1 18 ILEX CORNUTA "NEEDLEPOINT" NEEDLE POINT HOLLY 24 INCHES EVERGREEN SHRUBS AA 6 RHODODENDRON CONLEE, MED LAV AZALEA ENCORE AUTUMN AMETHYST 24 INCHES EVERGREEN SHRUB AC 6 RHODODENDRON ROBLED, DWARF AZALEA ENCORE AUTUMN CHIFFON 24 INCHES EVERGREEN SHRUB CF 3 CRIMSON FIRE LOROPETALUM LOROPETALUM X "CRIMSON FIRE" 24 INCHES EVERGREEN SHRUB LANDSCAPE NOTES: 1. MINIMUM STANDARDS FOR LANDSCAPE INSTALLATION: A. LARGE MATURE TREES SHALL HAVE A MINIMUM CALIPER OF 2 INCHES MEASURED 6 INCHES ABOVE THE PROPER PLANT LEVEL, OR A MINIMUM HEIGHT OF 6 FEET AT TIME OF PLANTING. B. MEDIUM AND SMALL/ORNAMENTAL TREES SHALL HAVE A MINIMUM HEIGHT OF 6 FEET AT THE TIME OF PLANTING. IN LIEU OF LARGE TREE PLANTING REQUIREMENTS, MEDIUM AND SMALL TREES SHALL BE PLANTED AT A RATE OF 2 TREES FOR EVERY 1 LARGE TREE. C. SHRUBS SHALL BE A MINIMUM OF 2 FEET IN HEIGHT AT TIME OF PLANTING. 2. SHRUBS PLANTED FOR SCREENING PURPOSES SHALL FORM THE REQUIRED DENSITY WITHIN 2 YEARS FROM THE TIME OF PLANTING. 3. GROUND COVER SHALL INCLUDE EVERGREEN OR ORGANIC COVERING AND PROVIDE 100% COVERAGE WITHIN 1 YEAR OF PLANTING, EXCEPT FOR MULCH OR TURF WHICH SHALL PROVIDE 100% COVERAGE UPON INSTALLATION. 4. RETENTION OF EXISTING VEGETATION SHALL BE MAXIMIZED TO THE EXTENT PRACTICAL, WHERE EVER SUCH VEGETATION CONTRIBUTES TO REQUIRED BUFFERING AND SCREENING. 5. WHEN EXISTING VEGETATION MEETS THE REQUIREMENTS FOR PLANTINGS THE ADMINISTRATOR MAY WAIVE SOME OR ALL OF THE REQUIREMENTS. 6. ALL BUFFER TYPES SHALL INCLUDE A STAGGERED ROW OF LARGE MATURING TREES AND AT LEAST 5 LOW GROWING SHRUBS FOR EVERY REQUIRED LARGE MATURING TREE. 7. STREETSCAPE BUFFER SHALL BE PLANTED WITH A ROW OF EVERGREEN CONIFERS OR BROADLEAF EVERGREENS PLACED NOT MORE THAN 5 FEET APART TO CREATE A CONTINUOUS HEDGE OF AT LEAST 6 FEET IN HEIGHT WITHIN TWO YEARS OF PLANTING SUPPLEMENTED WITH LARGE TREES EVERY 30 FEET. 8. ALL SPECIFICATIONS FOR THE MEASUREMENT, QUALITY, AND INSTALLATION OF TREES AND SHRUBS SHALL BE IN ACCORDANCE WITH AMERICAN STANDARDS FOR NURSERY STOCK, FREE FROM DISEASE AND IN SOUND AND HEALTHY CONDITION. 3X ROOTBALL DIAMETER' _K. YKUIVt UK NHEALTHY VIDE STAKING IF SPECIFIED. IF STAKING IS VIDED, PROTECT TREE WITH BROAD STRAP OR (IBLE TUBING. ALLOW FLEXIBILITY IN STRAPS TO ELOP TRUNK TAPER. PROVIDE TURN BUCKLE AND ZNING FLAGS. REMOVE ALL STAKING AND ESSORIES WITHIN ONE YEAR FROM PLANTING. COT FLARE SHALL BE PLANTED AT GRADE, NO R TAHN 2" ABOVE GRADE, AND NEVER BELOW E. REMOVE EXCESS SOIL TO EXPOSE THE FLARE AT GRADE. TREE SHALL BE SET PLUMB :H DEPTH 3". 'MULCH 3" FROM ROOT FLARE AND OT CONTACT STEM. HIGH QUALITY SOIL MIX AS SPECIFIED WATER SAUCER SHALL BE NO MORE THAN 3" ABOVE GRADE. COMPLETELY REMOVE TOP HALF OF BURLAP, LACING AND WIRE BASKET AND DISCARD FROM HOLE. ROOT BALL SHALL BE PLACED DIRECTLY ON COMPACTED SUBGRADE. HANDLE TREE BY THE ROOT BALL ONLY. NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR ADEQUATE DRAINAGE OF ALL PLANTING PITS. (POSITIVE DRAINAGE AWAY FROM PIT) 2. ADHERE TO STANDARDS IN THE CITY TREE MANUAL. 3. STREET TREES MUST BE 3" CALIPER AT INSTALLATION WITH A 5' MINIMUM FIRST BRANCH HEIGHT. 4. PLANTING SEASON OCTOBER - APRIL. 5. A TREE IMPACT PERMIT IS REQUIRED. 6. ELECTRICAL OUTLETS AND OTHER UTILITIES ARE PROHIBITED IN THE PLANTING AREA IMMEDIATELY SURROUNDING THE TREE. 00 o Z U E ....41z J" _0 0 Da o o _00u j O N .) vo V U� V) J Q= C I� Z LU o 0 4 Lu N N E Z L cn cn cn E U a 4 4 m ccm ° 0- c ;_ E E E3: '> a 0 0 E c: U U U Ui O -2 U p T) T) T o Inw, > > > U Of U 2 Z 0 Z �coyo( � L W �Q�0- -0 -0 -0 -0 cu D D � D i 5 � � � � � � W Q 00 LO N I- t0 N It 0 N 0 0 0 0 M O O N M It DO O N N N N N N N N 0 0 0 0 0 0 0 0 N N N N N N N N z O W } Z \ O o U 0 NW m— z< J_ w 00= Q �Qz� W z = OO O cr— Nw w U) O Z =)w � U) O o O~ J 0-1 LL 0- 0- V DATE #: 10/14/2022 MUNICIPAL PROJ #: - CLDG PROJ #: 2021003 DRAWN BY: SBT CHECKED BY: SBT ISSUED FOR CONSTRUCTION CONSTRUCTION DRAWINGS WON 1"=40' TREE PLANTING DETAIL NOT TO SCALE ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH HARNETT COUNTY, NCDEQ AND NCDOT CLDG STANDARDS, SPECIFICATIONS, AND DETAILS. ,