Loading...
HomeMy WebLinkAboutSW6221103_Stormwater Narrative_20221128DocuSign Envelope ID: 7D8BBAD3-49CA-494D-8540-BE287C7FDFB1 5245 Red Hill Church Rd FLEET TEM PLE Coats, NC 27521 ENGINEERING 910.658.2446 fleet@ftempleengineering.com PLLC Firm License P-2357 Iron Man Self Storage Anderson Creek Township, Harnett County 09.14.2022 PROJECT NARRATIVE Project & Site Description The purpose of this project is to develop a 8.2 acre commercial site (outdoor PV/boat storage). The property is existing undeveloped land and woodland. Existing topography drains to the north and east at slopes of approximately3% -10% to an un- named tributary S. Prong Anderson Creek. No wetlands will be disturbed on the Site. The Site is limited to maximum 24% impervious area upon build -out (Low Density Development). Adjacent Property The land uses in the surrounding areas are residential and agricultural. Soils The soils in this project consist of BnB (Blaney loamy sand, 2 to 8 percent slopes), GaB (Gilead loamy sand, 2 to 8% slopes), and Pa (Pains sandy loam). BnB is categorized as well drained, moderately slowly permeable, and is moderately suited to most urban and recreational uses. GaB is categorized as moderately well drained, moderately slowly permeable, and is moderately suited to most urban and recreational uses. Pa is categorized as poorly drained, moderately permeable, and is poorly suited to most urban and recreational uses. Planned Stormwater Management. Erosion and Sediment Control As shown on the Erosion Control Plan the project will be controlled and stabilized with diversion berms, silt fence, rock check dams, and temporary skimmer basins with baffles. Diversion berms will be constructed from topsoil graded from the site and will be backed with silt fence where needed. All measures will be constructed and maintained to NCDEQ & Harnett Countystandards and requirements. After erosion control measures are removed. Surface waters from the roadway areas will drain via grassed roadside ditches to owner maintained grassy swales which will convey the runoff from the property. Impervious areas on some portions of the lots will surface drain through the yard areas over the natural contours of the Site. Project impervious percentage is limited to 24%. Proposed impervious limits as follows: DocuSign Envelope ID: 7D8BBAD3-49CA-494D-8540-BE287C7FDFB1 IMPERVIOUS AREA CALCULATIONS: TOTAL PROPERTY AREA 3SS,380 SF IMPERVIOUS AREA ALLOWED: 24% MAX (LOW DENSITY) 3SS,380 SF X 0.24=85,291 SF MAXIMUM ALLOWABLE IMPERVIOUS IMPERVIOUS AREA BY DESIGN 10,780 SF ROAD (R/W) 35,232 SF (GRAVEL- LOT1) 36,921 SF (GRAVEL- LOT2) 82,933 SF TOTAL IMPERVIOUS BY DESIGN (23.3%) CA 44 �+ = 433 ��rr��iiiftis�►� 9/22/2022