Loading...
HomeMy WebLinkAboutNCC223911_Site Plan or Location Map_20221128RM-1 RM-1 co iI u LEGEND • EIP (AS DESCRIBED) POWER POLE O SIP (#5 REBAR W/CAP) UTILITY POLE NIPS (NO POINT SET) WM WATER METER FIRE HYDRANT C GUY WIRE e WATER VALVE TEMPORARY BENCHMARK ST STORM MANHOLE 675.7 SPOT ELEVATION CATCH BASIN DROP INLET SS SANITARY SEWAGE • TREE (AS DESCRIBED) BOUNDARY LINE (AS SURVEYED) 1011 570.75 INV — INV I Oo I I JGOpco^p,\�^ , , � co °O� O 0 40 80 FEET a ° I q�` Q"rP4<'�' I c 1 QQ xx�-P°°^ h1 40 °o o Q h h Q' Q- c� <v o � Q o � Q O I Q �P 0h O QP Q I I <v�0 Q Q v � Q Q' ° O ��h0ANI C� 0ti Q- o Q 0 h Q Q. � R M 1 Q- o� �Qvv R M -1 ��?�� I �—max` ��P�o/ �J �O°`� I RM 1 ,h Oh ^ QP P �j• , SEWER EEASEMENT XISTING ATOABE I I I (3 ;hi�h ^ Q Q QO R M -1 R M -1 O h �tK Q QP RE -PLATTED TO 30' I I a Q� Qj• � ��' (EXISTING 20') ❑ 0 00 �Qj� 00' �'. 25' REAR x SETBACK I(TYP) 10' SIDE MEN IN MOTION HOME SETBACK (TYP.) RENOVATIONS, LLC PIN: 5 6 31- 40 - 7132 �'p T t o.2AYTA�REs o.3fTA�RE,S DB:14764 PAGE: 92 r O rA kEs� , �0.2VA 0.A ARES r Moos SQ. Fr 14836 SO. Fr. 15' TYPE B BUFFE:7 ZONED: R M -1 13432 SQ. FT. I 11690 SQ. Ff. I I 11403 SQ FT. I I I / EXISTING JURISDICTIONAL I ' I BUILDING TYPF�Nc , STREAM PER TYPE 4 T 7 ' 30' ACCESS EASEMENT (TYP.) - 0.4 ACRES . ENVIRONMENTAL I I � s ASSESSMENT I i i I j - 177M SO. Fr. I l BUILDING TYPE 4 / I BUILDING / B 1 I 30:00' v I TYPE G TYPE I 1 2 I I I �.•' �� 10' VEGETATED SETBACK \ / j I25' 77 FRONT 30' UNDISTURBED STREAM BUFFER \ BUILDING �• .•' ��O 4 �� SETBACK 5' PUBLIC UTILITY EASEMENT'.: ' • m r. 4 5' PUBLIC UTILITY EASEMENT °a I / SAND FILTER +. ci Off, / G _._ _ __ 5' SIDEWALK (TYP.) p. T .. ENE COURT 50' PUBLIC ROW (LOCAL STREET) • __.__ _ __ . I Q Q� • o. � J 5 8' PLANTINGSTRIP I u� oo 0�00 0 m II 11 4. Y • + : gppl';li, �lli';,III11',II''I" _ ; Q Q / e 8' LEVEL 1 STREET YARD m / 25' FRONT O o0, �� l BUILDING'e..~ ° / SETBACK (TYP.)All L a i \ 1 50' PUBLIC ROW 'o S ��O I RIGHT-OF-WAY LINE - - - - EASEMENT LINE - - - - - - - - - - - - - - - - - GRAVEL TYPICAL LOT DETAIL PAVEMENT TIE LINE - 680' - — — - MAJOR CONTOUR LINE - - - - - - - - - - - - - - - - - MINOR CONTOUR LINE ----sc---- w---- w---- SD- STORM SEWER PIPE P P P P OVERHEAD POWER LINE SANITARY SEWER LINE ---G----G----G----G BURIED GAS LINE ----w----w----w----w— BURIED WATER LINE -x—x—x—x—x—x—x—x—x—x- FENCE LINE DITCH / DRAIN LINE TREE LINE �SD--SD----SD END OF LINE NOT LOCATED 25' REAR SETBACK Y Y U Q � m m I U) N w o �W o I N 0 10 25' FRONT SETBACK TRANSITION I FROM 60' ROW TO 50' ROW BUILDING TYPE 5 I I . J 0.234 TACRES 10208 SO. FT. 0.2 Wr •- 12012 SQ. Fr BUILDING I '+ `• ' TYPE 2 BUILDING T ` Lp g / 0.274 AC / Ty5 E SQ ...... . . ..... /_7 OAFTAMS —0 231 TACRES 10095 SQ. Fr l 10050 SQ. Fr II 0.315 AIRES �� 1 13711 SQ. Fr. I Oo lb O O) I I �• hh^� RM-1�����° O� �� h ^0 QOO I I I I I I g0' R/W KEENAN OR. 25' REAR BUILDING SETBACK (TYP.) R M - 1 I �° O I I I R M -1 I �Q°�����° of Q� '��°o o�°Q a • II I I I � I I ' I I EXISTING ZONING: RM-1 PROPOSED ZONING: RM-2 SITE DATA TABLE LOT SIZES: LOT NUMBER ACREAGE 1 0.315 2 0.276 3 0.234 4 0.231 5 0.232 6 0.274 7 0.408 8 0.340 9 0.252 10 0.262 11 0.268 12 0.308 ANTICIPATED FINAL PLATTING 10.01.2022 PARCEL NUMBER 5631-40-7132 EXISTING ZONING RM-2 - RESIDENTIAL MEDIUM DENSITY TOTAL PROJECT AREA 7.582 ACRES EXISTING IMPERVIOUS 0 ACRES PROPOSED IMPERVIOUS (RESIDENTIAL) 105,328 SF / 2.418 ACRES EXISTING LOTS 1 PROPOSED LOTS: 12 MAXIMUM RESIDENTIAL DENSITY 4 LOTS / ACRE * 7.582 ACRES = 30 LOTS PROPOSED RESIDENTIAL DENSITY 12 LOTS /7.528 ACRES = 1.6 LOTS/ACRE RESIDENTIAL LOT SIZE MINIMUM 10,000 SF, MINIMUM DIMENSIONS 75' WIDE BY 100' LONG RESIDENTIAL LOT SETBACKS FRONT SETBACK 25' (2 FRONT SETBACKS FOR CORNER LOTS, NON-DRIVEWWAY SETBACK MAY BE REDUCED TO 20'), 10' SIDE SETBACK, 25' REAR SETBACK TOTAL RESIDENTIAL OPEN SPACE 0.758 REQUIRED/ 3.263 ACRES PROVIDED TOTAL STREET RIGHT OF WAY AREA 0.805 ACRES fL W w U C 0 c I oZ<Z>N N V o u z U `.-�'� cMc o<a C7 W� o=Zoo _ v6 m o owo�Q U 12=oo �000> > 3 Z Z> 0>1 J c J =L�� Wt 0 v ¢ V 0 H 0 ILL. c •o ' L w U >:.v U _c»: r Lzr .......... W a 0 o 0� ON V J o N 04 N Y O \ / (3 boo - N Z O LLI CD Y 0 Z Q H Z elf m ¢ Z O m J p O Z F- Z w W wOw W Q0 0 CL Q a. } N J0 Z m o D w O F- COJ Z r7 W 0 U a m O N W Im N z Z Y W m Lv CD W 90 Ld G_ Z Y 3 c) LLI 0 o U ''� = CIVIL GEOTECHNICAL SURVEYING PO BOX 268 CONCORD, NC 28026-0268 P. 704.786.5404 F. 704.786.7454 www.cesicgs.com NCBELS CORP. NO. C-0263 ENGINEERS SEAL PRELIMINARY PLAN DO NOT USE FOR CONSTRUCTION C200 ROAD FRONTAGE co'