Loading...
HomeMy WebLinkAboutNC0041246_Wasteload Allocation_19950328NPDES WASTE LOAD ALLOCATION PERMIT NO.: NC0041246 PERMIIvIEE NAME: Lincoln County Schools FACILITY NAME: West Lincoln High School Facility Status: Existing Permit Status: Renewal Major Pipe No.: 001 Minor Design Capacity: 0.010 MGD Domestic (% of Flow): 100 % Industrial (% of Flow): Comments: RECEIVING STREAM: an unnamed tributary to Indian Creek, Class: C Sub -Basin: 03-08-35 Reference USGS Quad: F13NW (please attach) County: Lincoln Regional Office: Mooresville Regional Office Previous Exp. Date: 7/31/95 Treatment Plant Class: 1 Classification changes within three miles: Requested by: Prepared by: Reviewed oy: Charles Alvarez .44 I3 Date: 2/17/95 Modeler Date Rec. # �M,✓ 27,7/ 82--(90 Drainage Area (min ) 0, // Avg. Streamflow (cfs): 6•/3T 7Q 10 (cfs) 0 Winter 7Q10 (cfs) 0 Toxicity Limits: IWC % Instream Monitoring: 2n Parameters ) , % Upstream 30Q2 (cfs) o Acute/Chronic LocationY _$ /t om o- •�Q Downstream Y Location 3 00 Effluent Characteristics Summer Winter BOD5 (mg/1) 3 0 NH3-N (mg/1) yxwirT4✓ D.O. (mg/I) (� TSS (mg/1) 3 0 F. Col. (/100 ml) Zo 0 pH (SU) C,-q liffit'*-1C`6"- LI, Ag-)tof4wt cf-t. .-..t --/—f-oitt. Previous WLAs had the receiving stream Indian Creek, not a UT. This UT has been evaluated as a zero flow stream and Division zero flow procedure must be applied. 'The facility discharges into a stream with 7Q10/30Q24) cfs. Removal of discharge is recommended if a more environmentally sound alternative is available at an economically reasonable cost. An engineering report evaluating alternatives to discharge is due 180 days prior to permit expiration along with the permit renewal_ . application. As part of the report, the cost of constructing a treatment plant at the discharge point II) meet limits of 5 mg/1 BOD5, 1 mg/1 NH3, 6 mg/1 DO, and 17 14/1 chlorine should also be include& if there are no feasible alternatives to a surface discharge. Upon review of the results of the engineering report, the Division retains the right to reopen and modify this NPDES permit to require removal of the discharge or to revise the permit limitations within a specified time schedule." Comments:. rat.+ r1Q,uxt,P redid( FACT SHEET FOR WASTELOAD ALLOCATION Facility Name: NPDES No.: Type of Waste: Facility Status: Permit Status: Receiving Stream: Stream Classification: C Subbasin: County: Regional Office: Requestor: Date of Request: Topo Quad: West Lincoln High School NC0041246 Domestic - 100% Existing Renewal UT Indian Creek 030835 Lincoln MRO ()� Alvarez 2/17/95 F13NW Request # 8260 N.C. DEPT. OF ENVIRONMENT, HEALTH, & NATURAL RESOURCES MAR 20 1995 DIVISION OF ENJIROF!MENTAL MANAGEMENT MOORESVILLE REGIONAL OFFICE Stream Characteristic: USGS # Date: Drainage Area (mi2): Summer 7Q10 (cfs): Winter 7Q10 (cfs): Average Flow (cfs): 30Q2 (cfs): IWC (%): 0.11 0.0 0.0 0.15 0.0 Wasteload Allocation Summary (approach taken, correspondence with region, EPA, etc.) Previous WLAs had the receiving stream Indian Creek, not a UT. This UT has been evaluated as a zero flow stream and Division zero flow procedure must be applied. "The facility discharges into a stream with 7Q10/30Q2cfs. Removal of discharge is recommended if a more environmentally sound alternative is available at an economically reasonable cost. An engineering report evaluating alternatives to discharge is due 180 days prior to permit expiration along with the permit renewal application. As part of the report, the cost of constructing a treatment plant at the discharge point to meet limits of 5 mg/1 BOD5, 1 mg/1 NH3, 6 mg/1 DO, and 17 µg/1 chlorine should also be included) if there are no feasible alternatives to a surface discharge. Upon review of the results of the engineering report, the Division retains the right to reopen and modify this NPDES permit to require removal of the discharge or to revise the permit limitations within a specified time schedule." R_ecOntntirid Nil) ih aryi ritg dby;hgy jL.L )j,� nt tt/) Special Schedule Requirements and additional comments fromoReviewers: Recommended by,. Wt Reviewed by Instream Assessment:4/.1-1-1/L- Regional Supervisor;_2G�� Permits & Engineering: Date:3/13/95 Date: Date:/Zy��! Date: 3 RETURN TO TECHNICAL SUPPORT BY: ''y h 1 3 i"5 6 2 existing Limits: Wasteflow (MGD): BOD5 (mg/I): NH3N (mg/1): DO (mg/1): TSS (mg/1): Fecal Col. (/100 ml): pH (SU): Residual Chlorine (µg/1): Temperature (C): Recommended Limits: Wasteflow (MGD): BOD5 (mg/1): NH3N (mg/1): DO (mg/1): TSS (mg/1): Fecal Col. (/100 ml): pH (SU): Residual Chlorine (µg/1): Temperature (C): PARAMETERS Monthly Average Summer Winter WQ or EL 0.010 30 monitor nr 30 200 6-9 monitor monitor Monthly Average Summer Winter 0.010 30 monitor 30 200 6-9 monitor monitor Toxicity Test (P/F): r' plcr f2�•;�"�br,). qinlaketea ihs Due o: 1 ) Affected Change in 7Q10 data New regulations/standards New procedures New facility information Change in stream classification Other At next permit renewal, NH3 Choice Option Monthly Average WQ or EL Summer Winter WQ or EL 0.010 0.010 EL 30 30 2 4 AT Arin m" lc EL 30 30 200 200 6-9 6-9 monitor monitor monitor monitor or Cerio Qrtrly u � . fire_ @ 90% .cy4 fie_ Parameter(s) are water quality limited For some parameters, the available load capacity of the immediate receiving water will be consumed. This may affect future water quality based effluent limitations for additional dischargers within this portion of the watershed. OR X No parameters are water quality limited, but this discharge may affect future allocations. 3 INSTREAM MONITORING REQUIREMENTS Upstream Location: nih4t.b#2,4 Ovliccit Downstream Location:/✓ , baiDw Parameters: A p,) Temp. , C r, i, L'4ry1600f114 Special instream monitoring locations or momtoring frequen es: MISCELLANEOUS INFORMATION & SPECIAL CONDITIONS Adequacy of Existing Treatment Has the facility demonstrated the ability to meet the proposed new limits with existing treatment facilities? Yes No If no, which parameters cannot be met? Would a "phasing in" of the new limits be appropriate? Yes No If yes, please provide a schedule (and basis for that schedule) with the regional office recommendations: If no, why not? Special Instructions or Conditions Wasteload sent to EPA? (Major) (Y or N) (If yes, then attach schematic, toxics spreadsheet, copy of model, or, if not modeled, then old assumptions that were made, and description of how it fits into basinwide plan) Additional Information attached? (Y or N) If yes, explain with attachments. WEST LINCOLN HIGH SCHOOL UT INDIAN CREEK C 030835 Facility requesting renewal of existing limits.. Two discrepancies have come up since reviewing the wasteload allocation: 1) The permit effluent page shows a fecal coliform limit, however a limit was not recommended at the last wasteload allocation in 1988. Facility was streamlined in July 1993. A fecal coliform limit was added to the permit between 1988 and 1993. I would assume that it was added during the streamlining process in '93. The compliance monitoring system does not reflect the addition of the fecal limit. Fecal monitoring is taking place but a limit is not specified on the system. A review of the dilution ratio, 271:1, does show that a fecal coliform limit is needed. Will determine whether the facility will have to have a grace period to meet the fecal limit. 2) The receiving stream has been reported as Indian Creek but the staff report by G>T> Chen has it a UT Indian Creek. At the last wasteload review in 1988, per telecoih with Allen Hardy, he reported that the school's conveyance channel was on their property, with no other inflow of water, to Indian Creek. Therefore, the discharge was considered directly into Indian Creek. Upon this renewal however, GT says that it is a tributary to Indian Creek not considered to be a direct discharge. Said that it would uot take a lot to pipe the effluent to Indian Creek, only about 1000 ft to Creek. Told him we would have to look at the facility as probably a zero stream discharger and alternative analysis may need to be requested. Said the he was going to inspect the site soon and would get back to me. In 1988, Tech Support recommended the discontinuation of instream mgnitoring because of secondary limits w/ no DO limit and no reported problems instream. ` - H.-- di/ r- , e7-271di CW - /7g( - ALIT ; of/t-- /e""d AM3 Fadlity: NPDES#: Receiving Stream: Comment(s): Low Flow Record Station Number. Hydrologic Area Number: Drainage Area Low Flow Record Station: Qave Low Flow Record Station: s7Q10 Low Flow Record Station: w7010 Low Flow Record Station: 30Q2 Low Flow Record Station: Drainage Area New Site: MAR New Site: Qave per Report Equation: s7Q10 per Report Equation: w7Q10 per Report Equation: 3002 per Report Equation: Drainage Area Ratio: [new DA/Daatgage ] Weighted Ratio: Over -ride inappropriate Site (y ): West Lincoln High school UT Indian Creek e number not available must be < 400 sq. miles 0.11 sq. miles 1.4 cfs/miles squared 0 cfs 0.02 cfs 0.04 cfs 0.05 cfs Unuseable Drainage Area #DIV/OI #DIV/OI #DIV/0! Drainage Area New Site: MAR New Site: Weighted Qave per Report Equation: Weighted s7Q10 per Report Equation: Weighted w7Q10 per Report Equation: Weighted 3002 per Report Equation: 0.11 miles squared 1.4 cfs/miles squared #DIV/01 no input from above no input from above no Input from above Facility: West Lincoln High School NPDES#: nc0041246 Receiving Stream: Indian Creek Comment(s): Low Flow Record Station Number: Hydrologic Area Number: Drainage Area Low Flow Record Station: Qave Low Flow Record Station: s7010 Low Row Record Station: w7Q10 Low Flow Record Station: 3002 Low Flow Record Station: Drainage Area New Site: MAR New Site: Qave per Report Equation: s7010 per Report Equation: w7010 per Report Equation: 3002 per Report Equation: Drainage Area Ratio: [ new DA / Da at gage j Weighted Ratio: Over -ride Inappropriate Site (y ): gage number not available 02.1434.4000 HA10 27.00 miles squared 35.10 cfs 6.00 cfe 11.00 cfs 13.00 cfs must be < 400 sq. miles 19.00 sq. miles 1.4 cfs/miles squared 26cfs 4.11 cfs 6.26 cfs 8.82 cfs Continue 0.70 :1 Continue 0.60:1 Drainage Area New Site: MAR New Site: Weighted Qave per Report Equation: Weighted s7Q10 per Report Equation: Weighted w7Q10 per Report Equation: Weighted 3002 per Report Equation: 19.00 miles squared 1.4 cfs/miles squared 26 cfs 4.18 cfs 7.15 cfs 9.02 cfs WEST UNCOLN HS Residual Chlorine 7Q10 (CFS) DESIGN FLOW (MGD) DESIGN FLOW (CFS) STREAM STD (UG/L) UPS BACKGROUND LEVEL (UG/L) IWC (%) Allowable Concentration (ug/I) Fecal Limit Ratio of 271.0 :1 4.2 0.01 0.0155 17.0 0 0.37 4623.45 Ammonia as NH3 (summer) 7Q10 (CFS) DESIGN FLOW (MGD) DESIGN FLOW (CFS) STREAM STD (MG/L) UPS BACKGROUND LEVEL (MG/L) IWC (%) Allowable Concentration (mg/I) Ammonia as NH3 (winter) 7010 (CFS) 200/1oom1 DESIGN FLOW (MGD) DESIGN FLOW (CFS) STREAM STD (MG/L) UPS BACKGROUND LEVEL (MG/L) IWC (%) Allowable Concentration (mg/I) 4.2 0.01 0.0155 1.0 0.22 0.37 212.35 7.2 0.01 0.0155 1.8 0.22 0.21 735.74 NC0041246 1 2/1 3/9 4 domiLut) 7 SOC PRIORITY PROJECT: Yes No X If Yes, SOC No. To: Permits and Engineering Unit Water Quality Section Attention: Charles Alvarez Date: December 20, 1994 NPDES STAFF REPORT AND RECOMMENDATION County: Lincoln Permit No. NC0041246 PART I - GENERAL INFORMATION 1. Facility and Address: West Lincoln High School Lincoln County Schools Post Office Box 400 Lincolnton, NC 28092 `PT C 2 7 1994 2. Date of Investigation: 12-20-94 3. Report Prepared By: G. T. Chen 4. Persons Contacted and Telephone Number: Mr. Thomas C. Seagle, III, Lincoln County Schools Maintenance Director, 704-732-2261 5. Directions to Site: From the junction of Highway 27 and Shoal Road (SR 1002) approximately 7.40 miles west of the City Limits of Lincolnton, Lincoln County, travel south on SR 1002 approximately 0.1 mile. The school is located on the right (west) side of the road. 6. Discharge Point(s). List for all discharge points: Latitude: 35° 29' 10" Longitude: 81° 23' 42" Attach a U.S.G.S. map extract and indicate treatment facility site and discharge point on map. USGS Quad No.: F 13 NW USGS Name: Cherryville, NC 7. Site size and expansion are consistent with application? Yes X No If No, explain: 8. Topography (relationship to flood plain included): The topography of the wastewater treatment facility site is relatively flat, except the area behind the sand filter whereAA slopes off sharply. The site is not in a flood plain. 9. Location of nearest dwelling: None within 1,000 feet. 10. Receiving stream or affected surface waters: Unnamed tributary to Indian Creek a. b. c. Classification: C River Basin and Subbasin No.: Catawba and 03-08-35 Describe receiving stream features and pertinent downstream uses: The receiving stream is a narrow wet weather drainage ditch which is tributary to Indian Creek. The ditch had a small flow at the time of the inspection. Downstream users are unknown. PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater to be permitted: 0.0100 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the wastewater treatment facility? 0.0100 MGD c. Actual treatment capacity of the current facility (current design capacity)? 0.0100 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years: None. e. Please provide a description of existing or substantially constructed wastewater treatment facilities: The existing facility consists of a septic tank with dosing compartment (single bell), flow diversion box, a surface sand filter with three (3) PVC distribution lines, and tablet chlorination. f. Please provide a description of treatment facilities: N/A. g• h. Possible toxic impacts to surface than chlorine. Pretreatment Program (POTWs only): N/A. in development: approved: should be required: not needed: 2. Residuals handling and utilization/disposal scheme: proposed wastewater NPDES Permit Staff Report Version 10/92 Page 2 waters: None other a. If residuals are being land applied, please specify DEM Permit No.: Residuals Contractor: Telephone No.: b. Residuals stabilization: PSRP: ! RFRP: Other: c. Landfill: d. Other disposal/utilization scheme (specify): Sludge is removed and transported by Chaney Septic Tank Services to the City of Lincolnton's wastewater treatment plant for final disposal. 3. Treatment plant classification (attach completed rating sheet): Class I, see attached rating sheet. 4. SIC Code(s): 8211 Wastewater Code(s) of actual wastewater, not particular facilities, i.e., non -contact cooling water discharge from a metal plating company would be 14, not 56. Primary: 03 Secondary: Main Treatment Unit Code: 44007 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only)? N/A. 2. Special monitoring or limitations (including toxicity) requests: N/A. 3. Important SOC, JOC or Compliance Schedule dates: (please indicate) N/A. Date Submission of Plans and Specifications Begin Construction Complete Construction 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non -discharge options available. Please provide NPDES Permit Staff Report Version 10/92 Page 3 regional perspective for each option evaluated. Spray Irrigation: Insufficient land area available for a spray irrigation system. Connection to Regional Sewer System: No area -wide systems available in proximity to the school. Subsurface: Insufficient land area available for a subsurface disposal system. Other Disposal Options: The existing discharge location is approximately 1,500 feet east of Indian Creek. The Lincoln County Schools may explore the possibilities of extending the existing outfall to Indian Creek which has a positive 7Q10 flow. 5. Air Quality and/or Groundwater concerns or hazardous materials utilized at this facility that may impact water quality, air quality or groundwater? The existing facility discharges treated domestic wasteflow only. No hazardous materials are used at the facility. No air quality and/or groundwater concerns. 6. Other Special Items: N/A. PART IV - EVALUATION AND RECOMMENDATIONS Lincoln County Schools requests its NPDES Discharge Permit (No. NC0041246) for West Lincoln High School be renewed. An on - site investigation performed by staff of the Mooresville Regional Office revealed that the existing discharge is to an unnamed tributary to Indian Creek. The tributary did not appear to have sufficient natural flow. Therefore, a new wasteload allocation should be developed. In the interim, Lincoln County Schools may need to submit alternative analyses to the Division of Environmental management for review and determination if the existing discharge should be eliminated via extension of the outfall or construction of a non -discharge wastewater treatment plant. It is recommended that the subject Permit be renewed in consideration of the concerns noted above. NPDES Permit Staff Report Version 10/92 Page 4 Signaelrof Report Preparer Water Quality Reg Date z //frfr NPDES Permit Staff Report Version 10/92 Page 5 100% DOMESTIC FACILITIES - REC'D 6/93 RENEWING WITHOUT MODIFICATION 13Y MODELER Permit # Facility Stream FINAL LIST Sub -basin County Request Region VYLA7 MOD ENG Comments JMN 07/30/93 34673 TRI-COMMUNITY ELEM SCHOOL 34690 CHASE HIGH SCHOOL 58335 MESSIAH MTNS LUTHERAN CHURCH 25381 LAKE LURE WWTP, TOWN OF 75680 ROSEWOOD MHP 29297 FRED T. FOARD HIGH SCHOOL 74535 STEVE HALE/MARINA & RESTAURANT 74900 MSWS 41246 WEST LINCOLN SENIOR HIGH SCH 24279 CONOVER-SOUTHEAST WWTP #002 63797 WHISPERING PINES REST HOME 58084 GOUGH ECON, INC. SECOND BROAD RIVER GOODES CREEK LITTLE CRABTREE CREEK BROAD RIVER LINE CREEK POTTS CREEK CATAWBA RIVER MCCRARY CREEK INDIAN CREEK MCLIN CREEK SUGAR BRANCH UT PAW CREEK KEYS TO COMMENTS: Oa. No policy given. Alternatives analysis should be required. 0b. Facility must meet 5 & 1 (by date given in parenthesis). 0c. Alternatives analysis requested. Od. Alternatives analysis submitted. 0e. Facility will connect to POTW. 1. Phased permit. 2. Documented instream water quality problems. 3. Facility is requesting modification. 4. WLA should be done per basinwide permitting schedule. 030802 030802 040306 030801 040302 030835 030832 030832 030835 030832 030804 030834 RUTHERFORD RUTHERFORD YANCEY RUTHERFORD BUNCOMBE CATAWBA . IREDELL IREDELL LINCOLN CATAWBA CLEVELAND MECKLENBURG ARO ARO ARO ARO ARO MRO MRO MRO MRO MRO MRO MRO JMN MW JMN MW JMN MW JMN SG JMN SR JMN CA X JMN CA Assign BPJ limits X JMN CA Assign BPJ Limits JMN CA JMN DB JMN SG JMN SR Oa NOTE: IF 'X' UNDER "Request WLA?" COLUMN, THE ENGINEER SHOULD REQUEST A WASTELOAD ALLOCATION. ALSO, FOR A '0a' COMMENT, GIVE CURRENT ZERO -FLOW POLICY. FOR A 'Ob' COMMENT, GIVE 5 & 1 LIMITS BY DATE IN PARENTHESIS.