Loading...
HomeMy WebLinkAboutSW8130501_COMPLIANCE_20140604STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 f 3 O S O I DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE 2 014 0 6 04 YYYYMMDD Pusey, Steven From: Fisher, Ryan <rfisher@withersravenel.com> Sent: Wednesday, June 04, 2014 3:48 PM To: Pusey, Steven Cc: Butch Lawter; Hammers, Karl; Gary Kilker (Gary.Kilker@stwcorp.com); Hank Butts (hank.butts@stwcorp.com); Jimmy Washburn Subject: RE: Inspections Burton Industrial Park Concrete Plant Permit #SW8 130501 Attachments: BMP Certification - signed_140604.pdf Steve, The BMPs (BMP 41 & #2) that we are certifying have been listed on the certification now. Thanks, Ryan Fisher, PE Withers & Ravenel 115 MacKenan Drive I Cary, NC 27511 Phone: 919.469.3340 1 Fax: 919.467.6008 Direct: 919.535.5175 rfisher@withersravenel.com From: Pusey, Steven [mailto:steven.pusey@ncdenr.gov] Sent: Wednesday, June 04, 2014 3:29 PM To: Fisher, Ryan Cc: Butch Lawter; Hammers, Karl; Gary Kilker (Gary.Kilker@stwcorp.com); Hank Butts (hank.butts@stwcorp.com); Jimmy Washburn Subject: RE: Inspections Burton Industrial Park Concrete Plant Permit #SW8 130501 One more thing. Can you reference that this engineer's certificate applies to both ponds 1 & 2? This can be done either on the certification itself or via email letter. Thanks, Steve From: Fisher, Ryan[mailto:rfisher(alwithersravenel.com] Sent: Wednesday, June 04, 2014 3:16 PM To: Pusey, Steven Cc: Butch Lawter; Hammers, Karl; Gary Kilker (Gary. Kilker0stwcorp.com); Hank Butts (hank.butts(iilstwcorp.com); Jimmy Washburn Subject: RE: Inspections Burton Industrial Park Concrete Plant Permit #SWB 130501 Steve, Attached is our engineer certification for this concrete plant. Let us know if you need anything else. Thank you, Ryan Fisher, PE Withers & Ravenel 115 MacKenan Drive I Cary, NC 27511 Phone:919.469.3340 1 Fax:919.467.6008 Direct: 919.535.5175 rfisher@withersravenel.com From: Butch Lawter [ma ilto:Butch @stwcorp.com] Sent: Wednesday, June 04, 2014 3:11 PM To: Fisher, Ryan Subject: Fwd: Inspections Burton Industrial Park Concrete Plant Permit #SW8 130501 Sent from my iPhone Begin forwarded message: From: "Pusey, Steven" <steven.puseV ncdenr.eov> Date: June 4, 2014 at 3:09:55 PM EDT To: Butch Lawter <ButchCo)stwcorp.com> Cc: "Hammers, Karl' <karl.hammers@ncdenr.gov>, Gary Kilker <Garv.Kilker@stwcorp.com>, Hank Butts <Hank.Butts@stwcorp.com>, lames Washburn <lames.Washburn@stwcorp.com> Subject: RE: Inspections Burton Industrial Park Concrete Plant Permit #SW8 130501 Mr. Lawter, Any luck getting the engineers certification on the ponds at this concrete plant? I conducted an inspection and all looks compliant from a maintenance perspective. Now, we just need the engineers certification and we can wrap this one up. Please advise ASAP. Thanks, Steve Pusey DEMLR From: Butch Lawter [mailto:Butch (obstwcorp.com] Sent: Monday, April 14, 2014 4:03 PM To: Pusey, Steven Cc: Hammers, Karl; Gary Kilker; Hank Butts; Pusey, Steven; James Washburn Subject: Re: Inspections Burton Industrial Park Concrete Plant Permit #SW8 130501 Jimmy Washburn, our environmental compliance manager, will be contacting you regarding the corrective measures and schedule. I will check on the engineers certification. Thanks Butch Lawter Sent from my iPhone On Apr 14, 2014, at 3:43 PM, "Pusey, Steven" <steven.pusey@ncdenr.gov> wrote: No, that's fine. Actually, I made a mistake on the report. I meant to comment that we need for you to submit a signed copy of the Engineer's certification for the BMPs, namely Pond 1 and 2. A blank copy of the Engineer's certification form was submitted with the permit. Please excuse my mistake, and let me know if you have any questions about this issue or anything else. Thanks, Steve Pusey DEMLR From: Butch Lawter [mailto:Butch(ci)stwcorp.coml Sent: Monday, April 14, 2014 2:17 PM To: Pusey, Steven; Hammers, Karl Cc: Gary Kilker; Hank Butts Subject: Inspections Burton Industrial Park Concrete Plant Permit #SW8 130501 The attached plat was recorded on May 20, 2013.. The plat shows the access easements to BMP#s 1 and 2. Steven, is there something additional that should have been recorded? We have our ready -mix concrete operations manager, area grading superintendent and environmental compliance manager on -site evaluating the repairs needed and the time frame to complete them. I will keep you both updated. R. S. (Butch) Lawler, Jr. Senior Engineer <image001.jpg> 919-218-2834 (m) (fax) Mailing Address P.O. Box 2408 Wilson, NC 27894-2408 252-291-5165(o) Street Address 3801 Black Creek Road Wilson, NC 27893 252-243-0901 The information in this email and in any attachments is confidential and may be privileged. If you are not the intended recipient, please destroy this message, delete any copies on your systems and notify the sender immediately. You should not retain, copy or use this email for any purpose, nor disclose all or any part of its content to any other person. " NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor June 5, 2014 Mr. Henry Butts, Jr., Vice President S.T. Wooten Corporation P.O. Box 2408 Wilson, NC 27893 Subject: Notice of Inspection —Compliant Burton Industrial Park— Concrete Plant for S.T. Wooten Corp. Permit No. SW8 130501 Onslow County Dear Mr. Butts: John E. Skvada, III Secretary On May 28, 2014, staff from the Wilmington Regional Office of the Division of Energy, Mineral and Land Resources (DEMLR) inspected the Burton Industrial Park Concrete Plant in Onslow County to determine the status of compliance with the State Stormwater Management Permit Number SW8 130501, last modified on November 1, 2013. DEMLR file review and site inspection revealed that the site is compliant with the terms and conditions of this permit. Please find a copy of the completed form entitled "Compliance Inspection Report" attached to this letter, which summarizes the findings of the recent inspection. Please be advised that you are required to comply with the terms, conditions and limitations of your Stormwater Management Permit under Title 15A North Carolina Administrative Code 2H .1003 and North Carolina General Statute 143-214.7, including operation and maintenance of your permitted stormwater system. Violations of your Stormwater Management Permit may be subject to the assessment of civil penalties of up to $25,000 per day per violation. If the project has changed its name, ownership, or mailing address, it is your responsibility to submit a completed and signed Name/Ownership Change form to DEMLR at least 30 calendar days prior to making the changes. Please include the name, mailing address and phone number of the person or entity that is now responsible for this permit on the Name/Ownership Change form. If you have any questions, please contact me at the Wilmington Regional Office, telephone number (910)-796-7215 or via email at steven.pusey@ncdenr.gov. Sincerely, Steve G. Posey Environmental Engineer Eric: Compliance Inspection Report GDS\sgp: G:\WQ\Shared\ Stormwater\ Permits & Projects\ 2013\ 130501 HD\ 2014 05 CEI—Compliant 130501 cc: James Washburn, Environmental Compliance Manager— S.T. Wooten Corp. Georgette Scott, Wilmington Regional Office Stormwater Supervisor WiRO Stormwater File Division of Energy, Mineral, and Land Resources Land Quality Section — Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 • (910) 796-72151 Fax: (910) 350-2004 Compliance Inspection Report Permit: SW8130501 Effective: 05/16/13 Expiration: 05/30/21 Owner: S T Wooten Corporation Project: Burton Industrial Park Concrete Plant for S T Wooten Corporation County: Onslow, Burton Park Blvd Region: Wilmington Jacksonville NC 28540 Contact Person: Henry D Butts Title: Vice President Phone: 252-291-5165 Directions to Project: From int. of Hwy 53 & Hwy 24, hed NW on Hwy 24 for approx. 3 miles to int. of Hines Farm Rd east onto Hines Farm Rd for 1/2 mile to Burton Park Blvd south on Burton Park 1000' to site entrance on east side of road. Type of Project: State Stormwater - HD - Detention Pond Drain Areas: 1 - (NEW RIVER) (03-05-02) (C;NSW) 2 - (NEW RIVER) (03-05-02) (C;NSW) On -Site Rep,resentative(s): Related Permits: Inspection Date: 05/2812014 Entry Time: 11:00 AM Primary Inspector: Steven G Pusey Secondary Inspector(s): Karl J Hammers Reason for Inspection: Follow-up Permit Inspection Type: State Stormwater Facility Status: ■ Compliant ❑ Not Compliant Question Areas: ■ State Stormwater (See attachment summary) Exit Time: 12:00 PM Phone: Phone: Inspection Type: Compliance Evaluation Page: 1 Permit: SW8130501 Owner - Project: S T Wooten Corporation Inspection Date: 05128/2014 Inspection Type: Compliance Evaluation Inspection Summary: This project meets the minimum requirements for compliance with the permit. File Review Is the permit active? Signed. copy of the Engineer's certification is in the file? Signed copy of the Operation & Maintenance Agreement is in the file? Copy of the recorded deed restrictions is in the file? Comment: Built Upon Area Is the site BUA constructed as per the permit and approval plans? Is the drainage area as per the permit and approved plans? Is the BUA (as permitted) graded such that the runoff drains to the system? Comment: SW Measures Are the SW measures constructed as per the approved plans? Are the inlets located per the approved plans? Are the outlet structures located per the approved plans? Reason for Visit: Follow-up Comment: Inlet configuration is slightly different than the plans due to not having swales along the sides of the lot. Instead, drainage appears to sheet flow towards a pipe inlet which leads to the forebay. It appears to be working fine, therefore no change is required at present. Operation and Maintenance Are the SW measures being maintained and operated as per the permit requirements? Yes No NA NE ■❑❑❑ ®❑n❑ ■❑❑❑ ❑❑N0 Yes No NA NE ■❑❑❑ ■❑❑❑ ■❑❑❑ Yes No NA NE ❑■❑❑ Yes No NA NE ■❑❑❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to DWQ ❑ ❑ ❑ ■ upon request? Comment: The erosion at the outlet of BMP#1 has been repaired and fixed with riprap. Other Permit Conditions Is the site compliant with other conditions of the permit? Comment: Broken concrete and washout debris has been removed from the drainage area of BMP#2 and the drum washout area has been located at the site according to the plans. Yes No NA NE ■❑00 Page: 2 SMARTER TODAY RECEIVED MAY 01; 2014 April 30, 2014 Mr. Steve G. Pusey North Carolina Division of Land Quality Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 Subject: Notice of Inspection -Non Compliant: Corrective Action Plan S. T. Wooten Corporation Burton Industrial Park Onslow County, North Carolina Permit No. SW8 130501 Dear Mr. Pusey, S. T. Wooten Corporation Following please find a response to your letter dated, April 8, 2014 concerning the inspection of our concrete site located at the Burton Industrial Park. 1. The Engineering Certification: a. Shots have been taken of the entire site with the exception of the pond. Due to elevated water levels shots could not be taken. Therefore, weather permitting; the remainder of the shots is scheduled to be taken on Tuesday, May 6, 2014. 1 trust certification will follow shortly after. 2. BMP 41: a. This area has been repaired by placing riprap and new grass seed will be established. This should eliminate the outlet from eroding downstream. b. Future action: this area will be monitored on a weekly basis and after a rain event to determine if this concern has been resolved before further action is taken. I have attached a photo of this area for your convenience. 3. BMP # 2: a. Discarding washout water in the area has stopped. This area has been cleaned and concrete removed. b. Action taken: The actions that caused this problem has been addressed and corrected. Continued, Burton Industrial Park It's important to mention that it is not S.T. Woolen's policy to wash out trucks. We use a product that stops the setting of concrete. The Delvo mixture remains in the truck and concrete is loaded on this mix. Therefore, it is not necessary to modify the permit to allow for a washout since this matter has been corrected. I have attached a photo of this area for your convenience. Should you have any questions or require further information, please feel free to call me at your convenience. Karnes Washburn Environmental Compliance Manager 12204 Cleveland Road, Garner, NC 27529 Cell: 252-290-5912; Office: 919-779-9752; fax: 919-779-3963 WC Pusey, Steven From: Pusey,Steven Sent: Monday, April 14, 2014 3:44 PM To: 'Butch Lawter; Hammers, Karl Cc: Gary Kilker; Hank Butts Subject: RE: Inspections Burton Industrial Park Concrete Plant Permit #SW8 130501 No, that's fine. Actually, I made a mistake on the report. I meant to comment that we need for you to submit a signed copy of the Engineer's certification for the BMPs, namely Pond 1 and 2. A blank copy of the Engineer's certification form was submitted with the permit. Please excuse my mistake, and let me know if you have any questions about this issue or anything else. Thanks, Steve Pusey DEMLR From: Butch Lawter [ma ilto:Butch (@stwcoro.coml Sent: Monday, April 14, 2014 2:17 PM To: Pusey, Steven; Hammers, Karl Cc; Gary Kilker; Hank Butts Subject: Inspections Burton Industrial Park Concrete Plant Permit #SW8130501 The attached plat was recorded on May 20, 2013.. The plat shows the access easements to BMP#s 1 and 2. Steven, is there something additional that should have been recorded? We have our ready -mix concrete operations manager, area grading superintendent and environmental compliance manager on -site evaluating the repairs needed and the time frame to complete them. I will keep you both updated. R. S. (Butch) Lawter, Jr Senior Engineer � S.T. Wooten Corporttion 919-218-2834 (m) Mailing Address P.O. Box 2408 Wilson, NC 27894-2408 252-291-5165 (o) Street Address 3801 Black Creek Road Wilson, NC 27893 252-243-0901 (fax) The information In this email and in any attachments is confidential and maybe privileged. If you are not the intended recipient, please destroy this message, delete any copies on your systems and notify the sender Immediately. You should not retain, copy muse this email for any purpose, nor disclose all or any part of its content to any other person. *ij! t,',u Aon pu;}1 nbgxrt;• :Ult�?Jn( OU-%e'E- G^.9111U AjN% LEif)SGL UBrgnq Siuq rUF t.V;,: }L9ai:i (t't rr?t-,j :" •.it5 AA, pum Urti. Luggi, 411g OnMV M? 0SUZ3oL' 41.d9 &k.;q!Ua 2f1hw!um4Gi:U$ nuq EUAIL'!uwwvZ9;' awbpwRG stv mu's y UG iIL;yyoug' i:U`IS'I:p, i'')ri(-. Y): m i.i.,'.timag- 10 1a +C!.1" C t {.1 �' "1;' :.vo t , . ou wA � T'-` 1 e t) 7 Pt1~;m2 Ly moor: bWCW l r V Et '' `' ? c- r � `-1 ��, E , 0� 1., N t. s . . 1.. r +1'v�;btt' 7 sEJ:, -i' Ee.n,u' fir. 4?ei'1•iii`;T_; ;Zkjebiir:'I_:ic i3it L'L' BC�I:>.�i,i<,.; t_`.Li +;:N_+.G`5 i? f5 U% :5E41.!! !•� ; : �+,",�::T ,i+,�C:??Lh NIlt1� Ig91;i! (ytt}j2 Gus.• yiourj 'iA vNq Tv' 5C) 'i )' 1) 'u: ! gnri,rr: c�E: iLl;t)t cro:,z GA1.5oll ;uq;lztu l� kJ tv (E, irlrEG �ttai:{ �GLLI!!S 2tb'!S J3Ueu C vf), r(!jj -L. FiUL14; F;Ili» .��� :t~f`UCC'{I i9ity'Gi,,; {JJ411L•l�' t(`.:I� g'salji ;glUliq`c!,' `ji)1.1{ iq :)'i 4,4 ;x-�,., tvxr n.. ..ax nye v nxrac ... �nr::'_�.i :an..»..:.rr..,. c,r . n w.»w.:vnrm•^r.un :. s.nraocy�c+n:..se.:vn�+o+>:av-..�rv-a.......u_, rs sa.r•+++ev. mr_n vvrta✓rcra,n i Ar - AL D coNPureo n caovoPMiE UNLESS - u! asrnxcEs sxQAn' E F ✓ J5 TArnE ARITE B1.1 oiHEvwlsE. ALL NICM Iu Hu nr BEEN Pueuc uxless N'S IPBRI, E. - NO 'xENNBs rvIS BEEx BEuxF. A ON Mrs FAR. AREA NO 11..."INBFIRT� R 1 .N 20 M n RCW WIMP 0.iFA NO .'.iiC WRlY IS S MIMN 3MA' M5 RROPENJ 5-0A-M R SUBJER i0 Nl O THE OA, OF R, . 1. RE-nn• OF O A' A PB:OP ro THE TALE or rNrs Pur. NO MIB i0KSL nt ALL ON x0 CEJKIETEs EM 0S L Ov DID BEFEAEVCcS: ANAP . 3P P 1. 1]] IMP B'Jp( N P. 1. M BOp( JJ TALE 50 CVHJE I.ViU; un! I.18LE mN.l LEP.tN NwJs rc,in r. sxr 1 wo Bna I raxo Le AT I IF IN 1.11 1. 11 AIR - Burtan Port I. an oppweG Rannoo Mnbpment. The minimum _I.� Weser/tRI raau'semenl w rewu4tl In. ngcL. t,/ Zexing 041,ict. Nae them, nxrveE amend the grfmater el the Pare. F. . NIM_ MG 1.B I4F6 ZONE v0-« IoiY E N .S x No. n n OF eurnm+elr PipL4tt M1CaL50 UMTx PM+ aLM. VMST 1. mall -- b • —err-= ;,x�r'�,: I lam,+ee �w 11...)en l.1 AA a off. v rAN.p,NAA.1. nARAL m+a mw+ww1 m ee 1n ue.��ewi.e, w..e,« — w� �nnw'nap- �.� fid�41, = ! E SEAL f...r. - n. ♦Y4 W yN.cYAliQ�`� .ia. c.nh..M _A RAF SCALE .eAIR _GRAPHIC A n1me:.a_ow IN ren I a foVrLa l(ell t'bode - .'I, ,0.00 K END K .O 'A' ro IF LINE TABLE BARTLETT _— — E NEOMND a SURVEYING. a N.w sner oN'x Ivl im a TBN ...c : aa .-a.4 0 2 1:HY'R �RWFLi: YxE 7 .m1 1WaN; Ll 1 1 LDBAMN EINP 19 1GVE M®11111111111141 eweea. tt..: Re na uhm eml ., a In B — -66A. -138 day Of In Regular Of Deed. SLIFIV 'FRi 3T. WOOTEN OCFFORATKri FINAL PLAT 6UATON 61XU57fML LOT4 \\s.�J\vur4\-EIGO\1/.M.WrCi$\TM1I\1Jn.\a. v\1Jiz.BO.e.a V.12au B_ll:z: W FOR —�vc4�iz-2 �a �� �y � � � w NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary April 8, 2014 Mr. Henry Butts, Jr., Vice President S.T. Wooten Corporation P.O. Box 2408 Wilson, NC 27893 Subject: Notice of Inspection - Non Compliant Burton Industrial Park - Concrete Plant for S.T. Wooten Corp. Permit No. SW8 130501 Onslow County Dear Mr. Butts: On April 2, 2014, staff from the Wilmington Regional Office of the Division of Energy, Mineral and Land Resources (DEMLR) inspected the Burton Industrial Park Concrete Plant in Onslow County to determine the status of compliance with the State Stormwater Management Permit Number SW8 130501, last modified on November 1, 2013. DEMLR file review and site inspection revealed that the site is not compliant with the terms and conditions of this permit. Please find a copy of the completed form entitled "Compliance Inspection Report" attached to this letter, which summarizes the findings of the recent inspection. As indicated in the attached inspection report, the following deficiencies must be resolved: / 1. A.copy�''ef-the-reeerded-deed-res#ictlons-must-be-submitted-tothis-office--within-thirty-(-30)-days-of— / S eg<; j r6eOr41�. �/.�Rot` R cop,, D{ -/'tc Srrj�..if �'n jln%arif ref' . 4r l�r+P�+ I�+Jr 2.11l ecorru'P''•• 2. BMP #1 has erosion downstream of the outlet structure. This area needs to be stabilized with additional 6h k'7N) riprap and/or groundcover. The discharge should sheet flow across the grass; not be channelized. A scour hole and/or a level spreader may be needed. 3. Concrete truck drum washout area was not located per the plans, causing the wash water to drain to BMP #1 and BMP #2 instead of draining solely to BMP #1 as designed and permitted. In order to correct this situation, the washout area should be moved to where it is located entirely within drainage area #1. Alternately, the permit may be modified so that the wash water can be sent to BMP #2 in addition to BMP #1. In this case, engineer certified calculations would be required to show that BMP #2 can handle the wash water volume. Please inform this Office in writing before May 8, 2014, of the specific actions that will be undertaken and the time frame that will be required to correct the deficiencies. Failure to provide the requested information, or to respond to this letter by the due date, may initiate enforcement action including the assessment of civil penalties of up to $25,000 per day. If a written plan of action is not submitted to this office by May 8, 2014 then DEMLR staff will re- inspect the site and issue a Notice of Violation if the listed deficiencies have not been addressed. If the project has changed its name, ownership, or mailing address, it is your responsibility to submit a completed and signed Name/Ownership Change form to DEMLR at least 30 calendar days prior to making the changes. Please include the name, mailing address and phone number of the person or entity that is now responsible for this permit on the Name/Ownership Change form. If you have any questions, please contact me at the Wilmington Regional Office, telephone number (910)-796- 7215 or via email at steven.pusey@ncdenr.gov. Sincerely, Steve G. Pusey Environmental Engineer (�JEnc: Compliance Inspection Report ,}PGDS\sgp: G:\WQ\Shared\Stormwater\Permits 8 Projects\2013\130501 HD\2014 04 CEI_deficient 130501 cc: Georgette Scott, Wilmington Regional Office Stormwater Supervisor WiRO Stormwater File Division of Energy, Mineral, and Land Resources Land Quality Section - Wilmington Regional Office 127 Cardinal Drive Extension, Wilminqton, North Carolina 28405 - (910) 796-7215 / Fax: (910) 350-2004 i Compliance Inspection Report Permit: SW8130501 Effective: 05/16/13 Expiration: 05/30/21 Owner: S T Wooten Corporation Project: Burton Industrial Park Concrete Plant for S T Wooten Corporation County: Onslow Burton Park Blvd Region: Wilmington Jacksonville NC 28540 Contact Person: Henry D Buffs Title: Vice President Phone: 252-291-5165 Directions to Project: From int. of Hwy 53 & Hwy 24, hed NW on Hwy 24 for approx. 3 miles to int. of Hines Farm Rd east onto Hines Farm Rd for 1/2 mile to Burton Park Blvd south on Burton Park 1000' to site entrance on east side of road. Type of Project: State Stormwater - HD - Detention Pond Drain Areas: 1 -(NEW RIVER) (03-05-02 ) ( C;NSW) 2 - (NEW RIVER) (03-05-02) (C;NSW) On -Site Representative(s): Related Permits: Inspection Date: 04102/2014 Entry Time: 01:30 PM Primary Inspector: Steven G Pusey Secondary Inspector(s): Karl J Hammers Reason for Inspection: Routine Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant ■ Not Compliant Question Areas: M State Stormwater (See attachment summary) Exit Time: 02:30 PM Phone: Phone: Inspection Type: Compliance Evaluation Page: 1 Permit: SW8130501 Owner - Project: S T Wooten Corporation Inspection Date: 04/02/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: The following actions are required to bring this project into compliance: 1. A copy of the recorded deed restrictions has not been submitted to this Office. Please submit within thirty (30) days of recording. 2. BMP #1 has erosion downstream of the outlet structure. This area needs to be stabilized with additional riprap and groundcover. A scour hole or level spreader may be necessary to stop the channelization of flow. 3. Concrete truck drum washout area was not located per the plans, causing the wash water to drain to BMP #1 and #2 instead of draining solely to BMP #1 as designed and permitted. In order to correct this problem, the washout area should be moved to where it is located entirely within drainage area #1. Alternately, the permit may be modified so that the wash water can be sent to BMP #2 as well as BMP #1. In this case, calculations would be required to show that BMP #2 can handle the wash water volume. Page:2 Permit: SW8130501 Owner • Project: S T Wooten Corporation Inspection Data: 04/02/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine File Review Yes No NA NE Is the permit active? Signed copy of the Engineer's certification is in the file? Signed copy of the Operation & Maintenance Agreement is in the file? Copy of the recorded deed restrictions is in the file? Comment: A eepy-ef-the-recorded-deed-restrictions-hes-not-been-subrnitted-to-this Built Upon Area Is the site BUA constructed as per the permit and approval plans? Is the drainage area as per the permit and approved plans? Is the BUA (as permitted) graded such that the runoff drains to the system? Comment: SW Measures Are the SW measures constructed as per the approved plans? Are the inlets located per the approved plans? Are the outlet structures located per the approved plans? Comment: The inlet configuration is different than the plans due to not having swales along the sides. Drainage appears to sheet flow towards a pipe inlet to the forebay. No change is required at present. ❑❑■❑ Yes No NA NE ■ 0 ❑ ❑ ■❑❑❑ ■ ❑ D ❑ Yes No NA NE ■❑O❑ ❑ ■ ❑ ❑ ■❑❑❑ Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? ❑ ■ D ❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to DWO ❑ ❑ D ■ upon request? Comment: BMP #1 has erosion downstream of the outlet structure. This area needs to be stabilized with additional riprap and groundcover. A scour hole or level spreader may be necessary to stop the channelization of flow. Other Permit Conditions Is the site compliant with other conditions of the permit? Yes No NA NE ❑ ■ ❑ ❑ Page:3 Permit: SW8130501 Owner - Project: S T Wooten Corporation Inspection Date: 04/02/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Comment: Concrete truck drum washout area was not located per the plans, causing the wash water to drain to BMP #1 and #2 instead of draining solely to BMP #1 as designed and permitted. In order to correct this problem, the washout area should be moved to where it is located entirely within drainage area #1. Alternately, the permit may be modified so that the wash water can be sent to BMP #2 as well as BMP #1. In this case, calculations would be required to show that BMP #2 can handle the wash water volume. Page:4 1 State Stormwater Inspection Report General nt Project Name: �Nr�q T��u� P 404t Permit No: SW8 130501 Expiration Date: Contact Person: CS lJoe% ID/qnf Phone Number: Inspection Type: ss"J Inspection Date: 2 Time In: Time Out: Current Weather: C I�Ar �p uF Recent Rain (Date)?3. � Rain- Ab.1 in r-Z,6 1 f-dwNS 4OR Location Facility Address / Location: 134 f �o wr� 9 J',fQ )ple on v / lie City: 'Tel ti u/ /7( zip: 2s5'f0 County: 0oIC4 Lat 31 ° 17 ` ZI "N Long: - 77 ° 7W & "W Permit Information Rule Subject to (circle one): 1988 Coastal Rule 1995 Coastal Rule 008 Coastal Rule-) Session Law 2006-246 Goose Creek High Quality Waters Outstanding Resource Waters Density (circle one): 6231 Low (LD) Stormwater Best Management Practices (BMPs) (insert number of each): 2Wet Ponds _Infiltration Basins _Infiltration Trenches LD Swales _Stormwater Wetlands _Dry Ponds Bioretention Permeable Pavement _Sand filters (circle one) Open Closed _Cistern Level Spreader/Filter Strip Other (specify): File Review Yes No N/A N/E 1. Is the permit active? 2. Si ned En ineer's Certification on file? 3. Signed Op eration and Maintenance agreement on file? Recorded Deed Restrictions on file? Site Visit- Ruilt Ilnnn Area /RIIAI . Vas _ Nn N/A N/F 5 UA is constructed and consistent with the permit requirements? BUA aspermitted) is graded such that the runoff drains to the system? (high density only) t' / 7 Draina a area is consistent with permit? i.e. no un ermitted drainage to the SW BMPs 8. raina a area is stabilized? to reduce risk of sedimentation to the SW BMPs Site Visit: Stormwater BMPs f\ ea Awl( Yes No N/A N/E 9. Stormwater BMPs are located per the approvedplans? 10. Stormwater BMPs have dimensions (e . length, width, area) matching the approvedplans? 11. Stormwater BMPs are constructed per the approvedplans? Site Visit: Operation and Maintenance Yes . No N/A N/E 12. Access points to the site are clear and well maintained? 13. Trash has been removed as needed? 14. Excessive landscape debris (grass clippings, leaves, etc) is controlled? 15. Stormwater BMPs being operated and maintained as per the permit requirements? 16. Inspection and Maintenance records are available for inspection? (high density only, 1995 — present only) Site Visit: Other Water Quality Issues 9 t %� 4lv6M e Yew No NIA N/E r 18. Is the site compliant with other water quality issues as noted durine the inspection? (`­e. State Stormwater Inspection Report, version 3.0_3-09 Page I of 2 State Stormwater Inspection Report Ins ection Pictures (some of the pictures taken during the site visit) Compliance Status ❑ Compliant VIZ Non -Compliant o? Letter Sent (circle one): Yes No Letter type: �,) NNOV NOVRE Other Date Sent: Reference Number: Inspector Name and Signature: Date: Slate Slortnwater Inspection Report, Version 3.0_3-09 Page 2 of 2 WET DETENTION O & M Inspection Checklist INLETS and FORESAY 1. Inlets are located per the approved plans: G tian� v+1 o,1,y�t ❑ 7 ❑ ❑ 2. Inlet device (swale or pipe) is free of damage, clogs or erosion: I'kr� f 44-w, 2 ❑ ❑ ❑ 3. Forebay berm is in place and without erosion: �K'�""� Ee . ❑ ❑ ❑ 4. Forebay is free of excessive sediment: EK ❑ ❑ ❑ SIDE SLOPES AND BANKS S. Vegetated slopes are 3:1 or less: Uv ❑ ❑ ❑ 6. Banks are stable and free of erosion or bare soil: ❑ ❑ ❑ 7. Slopes or berms are free of woody vegetation: 9 ❑ ❑ ❑ 8. Free of muskrats or beaver activity: 2 ❑ ❑ ❑ 9. Grass is being maintained and mowed (not scalped) as required: 9 ❑ ❑ ❑ PERIMETER AND MAIN BAY 10. Vegetated shelf is 6:1 or 10:1 as permitted and properly vegetated: ❑ ❑ ❑ 2 11. Algal growth covers less 50% of the area: ✓U ❑ ❑ ❑ 12. Cattails, phragmites or other invasive plants cover less than 50% of the basin surface: Ltd ❑ ❑ ❑ 13. Main treatment area is free from excess sediment accumulation: 2' ❑ ❑ ❑ 14. Swale or emergency outlet bypass is in the correct place and is in good condition: �ry � ❑ ❑ 15. Drawdown device is correctly sized free of damage or clogging: OR ❑ ❑ ❑l 16. Orifice size matches the approved plans El ❑ El_l_y/ 17. Outlet is free of erosion or other signs of damage: t3 A k-y5 ❑ ❑ ❑ 18. Trash rack is installed oC�rNc��w� o ❑ ❑ EV ❑ 19. Vegetated filter is in place (if applicable) ❑ ❑ [/ ❑ 20. Relative elevations match approved plans L' ❑ ❑ 21. Fountain pump (if permitted) is less than or equal to the maximum allowable size: El ElI� ,❑l ❑ V3.3_09