Loading...
HomeMy WebLinkAboutGuilford_Well Abandonment_20221118 N WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Jacob L. Rhud III ° Y� 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of NC-4229-8 wells abandoned: i k r NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): 1 (gal.) EnviroCheck of Va, Inc FOR WATER SUPPLY WELLS ONLY: Company Name 7c.Type of disinfectant used: 2.Well Construction Permit#: u n k List all applicable well construction permits(1.e.UIC,County State,Variance,etc.)Ifknown . 7d.Amount of disinfectant used: 3.Well use(check well use): Water Supply Well: 7e.Seating materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑Neat Cement Grout N Bentonite Chips or Pellets ❑Geothermal(Reating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑Dry Clay ❑lndustrial/Commercial ❑Residential Water Supply(shared) ❑Concrete Grout ❑Drill Cuttings ❑Irti ation ❑ Specialty Grout ❑Gravel Non-Water Supply Well: ❑Bentonite Slurry ❑Other(explain under 7g) RMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑Groundwater Remediation 50 Ibs ❑Aquifer Storage and Recovery ❑Salinity Barrier []Aquifer Test ❑Stormwater Drainage ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) filled annulus with bentonite,hydrated, capped to match existing F �, F� 4.Date well 11/8/2022s)abandoned: t1 # 5a.Well location: 022 EM 99GRE Una Facility/Owner Name Facility lD#(if applicable) 8.Certification- r,4;'�/ 101 Spring Street, Greensboro, NC Physical Address,City,and Zip Si of Certified Well tractor or Well Owner Da Guilford By signing this form, I hereby certify that the well(s) was(were)abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C 0100 or 2C.0200 Well Construction Standards Sb.Latitude and longitude in degrees/minutes/seconds or decimal degrees: and that a copy of this record has been provided to the well owner. (if well field,one lat/long is sufficient) 9.Site diagram or additional well details: 36.073 N 79.79708 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. i CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction record(s)ifavailable.For multiple injection or non-water supply wells ONLY with the same constructionlabandonment,you can submit one form. 1t A`�t, 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#• 1 V 1 Y V—6 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 20 00 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Infection Wells: In addition to sending the form to the address in 10a 6e.Borehole diameter: 8.25 (in.) above,also submit one copy of this form within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface: 15 (ft.) Division of Water Resources,'Underground Injection Control Program, 1636 Mail Service Center,Raleigh,NC 276994636 6e.Outer casing length(if known): 20 00 10c.For Water Supply&Injection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6E Inner casing/tubing length(if known):20 (ft.) abandoned. 6g.Screen length(if known): u n k (ft) Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016 i