HomeMy WebLinkAboutBeaufort_Well Abandonment_ (4) WELL ABANDONMENT RECORD For Internal Use ONLY:
1.Well Contractor Information: WELL ABANDONMENT DETAILS
Justin Radford 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same
Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of
3270-A wells abandoned:
NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): 8.1 1 (gal.)
Geological Resources, Inc. FOR WATER SUPPLY WELLS ONLY:
Company Name 7e.Type of disinfectant used:
2.Well Construction Permit#: N/A
List all applicable well constriction permits(i.e.UIC,County,State, Variance,etc)rfknown
7d.Amount of disinfectant used:
3.Well use(check well use):
Water Supply Well: 7e.Sealing materials used(check all that apply):
❑Agricultural ❑Municipal/Public ❑ Neat Cement Grout X Bentonite Chips or Pellets
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay
❑Industrial/Commercial ❑Residential Water Supply(shared) N Concrete Grout ❑ Drill Cuttings
❑Irrigation ❑ Specialty Grout ❑ Gravel
Non-Water Supply Well: ❑ Bentonite Slurry ❑ Other(explain under 7g)
RMonitoring ❑Recovery
Injection Well: 7f.For each material selected above,provide amount of materials used:
❑Aquifer Recharge ❑Groundwater Remediation 60 Ibs of Bentonite
❑Aquifer Storage and Recovery ❑Salinity Barrier
❑Aquifer Test ❑StormwaterDrainage 5 Ibs Concrete
❑Experimental Technology ❑Subsidence Control
7g.Provide a brief description of the abandonment procedure:
❑Geothermal(Closed Loop) ❑Tracer o
Pour: ; �.
❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) s
4.Date well(s)abandoned. 09/26/2022
5a.Well location: 1OiO{" ' 'r Urai
�4JZr t�l is)�
Belhaven Bulk Plant n/a
Facility/Owner Name Facility ID#(if applicable) 8.Certification:
655 US Highway 264 By-pass, Belhaven, NC 09/27/2022
Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date
Beaufort 7606-53-2921 By signing this form, I hereby certify that the ivell(s) ivas (were) abandoned in
County Parcel Identification No.(PIN) accordance with 1 SA NCAC 02C.OI00 a•2C.0200 Well Construction Standards
56.Latitude and longitude in degrees/minutes/seconds or decimal degrees: and that a copy of this record has been provided to the well owner.
(ifwell field,one Iattlong is sufficient) 9.Site diagram or additional well details:
35.5509850 N 76.6290190 W You may use the back of this page to provide additional well site details or well
abandonment details. You may also attach additional pages if necessary.
CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS
Attach well consiniction record(s)ifavailable. Fornndtiple injection or non-watersupply wells
ONLY with the same construction/abandonntent,you can submit one forur.
�tll`It/ 10a. For All Wells: Submit this form within 30 days of completion of well
6a.Well ID#: 1 V I V V-1 3 abandonment to the following:
Division of Water Resources,Information Processing Unit,
6b.Total well depth• 54.25 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617
10b.For Infection Wells: In addition to sending the form to the address in 10a
iUnknown above, also submit one copy of this form within 30 days of completion of well
6c.Borehole diameter: (n.)
abandonment to the following:
6d.Water level below ground surface: 4.52 (ft.) Division of Water Resources,Underground Injection Control Program,
1636 Mail Service Center,Raleigh,NC 27699-1636
6e.Outer casing length(if known): n/a (ft.) 10c.For Water Supply&Iniection Wells: In addition to sending the form to the
address(es)above,also submit one copy of this form within 30 days of completion
of well abandonment to the county health department of the county where
6f.Inner casing/tubing length(if known): 50 (ft.) abandoned.
6g.Screen length(if known): 5 (ft.)
Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016