Loading...
HomeMy WebLinkAboutGW1-2022-09512_Well Construction - GW1_20221017 WELL CONSTRUCTION RECORD(GW-1) For Internal Use Only: 1.Well Contractor Information: Hugo Rivas 14.WATER.ZONES' }> Well Contractor Name FROM TO I DESCRIPTION 1 3159 ft. ft. NC Well Contractor Certification Number 15.OUTER.CASING for multi-cased we OR LINER.if a livable Mcpherson Well Drilling r•RoM TO DIAMETER1 THICIINESS MATERIAL 0 ft. 157 s 2 sch40 pvc Company Name 16.INNER CASING OR TUBING(geothermal closed-loop) 2.Well Construction Permit#: FROM To I DIAMETER i I THICKNESS MATERIAL List all applicable well construction permits(i.e.UIC,County,State,Variance,etc.) ft. n iin. 3:Well Use(check well use): ft. fL 'in. Water Supply Well: 17.SCREEN FROM TO DIAMETER :SLOT SIZE THICKNESS MATERIAL ❑Agricultural ❑Municipal/Public it �fl . in. 157 1672 8 ' sch40 pvc []Geothermal(Heating/Cooling Supply) InResidential Water Supply(single) ft 157 im pindustrial/Commercial ❑Residential Water Supply(shared) 18.GROUT ❑hri ation ❑Welts>100,000 GPD FROM TO MATERIAL' EMPLACEMENT METHOD&AMOUNT Non-Water Supply Well: 0 ft. 3 ft. cement j: pour ❑Monitoring ❑Recovery 3 ft. 100 ft. bentonite tremmie Injection Well:' iG tt. I ❑Aquifer Recharge []Groundwater Remediation 19.SAND/GRAVEL PACK f applicable) ❑Aquifer Storage and Recovery ❑Salinity Barrier FROM To MATERIAL; EMPLACEMENTMETHOD ❑Aquifer Test ❑StorrawaterDrainage 100 ft. 167 ft- gravel#1 pour ; ❑Experimental Technology ❑Subsidence Control ft. fL ❑Geothermal(Closed Loop) []Tracer 20.DRILLING LOG attach additional sheets if necessary) ❑Geothermal(Heating/Cooling Return) ❑Other(explain under#21 Remarks) FROM TO DESCRIPTION color.badness,soil/rack type,grain Stu,etc.) 10/12/22 0 6- 10 ft. sand-clay 4.Date Well(s)Completed: Well 101# 10 ft 100 m clay 5a.Well Location: 100 m 110 fL sand ' Dinah Reaves Elkin 110 ` 130 Ht clay V - r Facility/Owner Name Facility lD#(if applicable) 130 ft- 145 tt. clay 1184 Jimmie Hester Rd Clarkton NC 28433 145 ` 167 fL sand OCT 17.2022 Physical Address,City,and Zip ft. ft. Columbus 21.REN ARKS County Parcel identification No.(PIN) 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field,one laUlong is sufficient) 22.Ce C lion: N `�' 10/12/2022 6.Is(are)the well(s): C1Permanent or ❑Temporary Signat&e of Certifleftell Contractor Date By signing this form,I hereby certify that the well(s)was(were)constructed in accordance with 7.Is this a repair to an existing well: ❑Yes or MNo I5A NCAC 02C.0100 or 15A NCAC 02C.0200 Well Construction Standards and that a copy If this is a repair•fill out known well construction information and explain the nature ofthe of this record has been provided to the well owner. repair under#21 remarks section or on the back of thisform. 1' 23.Site diagram or additional well details: 8.For Geoptohe/DPT or Closed-Loop Geothermal Wells having the same You may use the back of this page to!provide additional well construction info construction,only 1 GW 1 is needed. Indicate TOTAL NUMBER of wells (add'See Over'in Remarks Box).You may also attach additional pages if necessary. drilled: 24.SUBMITfAL INSTRUCTIONS 9.Total well depth below land surface: 167 (ft) For multiple wells list all depths l(dierent(example-3@200'and 2@1001 Submit this GW-1 within 30 days of well completion per the following: 1 ' 10.Static water level below top of casing:40 (ft) 24a. For All Wells: Original form to Division of Water Resources (DWR), If water level is above casing,use„+"If Processing Unit,1617 MSC,Raleigh,NC 27699-1617 6 24b.For Injection Wells:C DWR, Il.Borehole diameter:. .. (in.) Copy to Underground Injection Control(IUC) o Program,1636 MSC,Raleigh,NC 27699-1636 12.Well construction method: Rotary 24c.For Water Sup Iy and Open-Lo�p Geothermal Return Wells:Copy to the (i.e.auger,ratarA cable,direct push,etc.) county environmental health department of the county where installed FOR WATER SUPPLY WELLS ONLY: 24d.For Water Wells producineover 100,000 GPD:Copy to DWR,CCPCUA Permit Program,1611 MSC,Raleigb,NC 2 p 7699-1611 13a.Yield Writ)20 Method of test:~i r 1, 13b.Disinfection type:Granulated Amount: 1/8 lbs