Loading...
HomeMy WebLinkAboutNCC223607_Site Plan or Location Map_20221020(VZUlb CAJJ, NIAUN & RCrvrvCUY, INU. tAYF(tJJLY HtAtHVtJ I It) t UIVIIVIUN LAW k UYYNIla F1I ANU U I ntH I-HUI'rN I Y MUM It) IN IF1tJt I-LANJ. I F1tJt I-LANJ AN= NU I Ill br- Nr_I-NUUUk r_U, UrIANutU UN k UI-ItU IN ANY rUNIVI UN IVIANNtH Wr1A I JUtVtH, NUN AHt IntY Ill tit AJJIIarvCU Ill ANY I r1INU I -AN I Y VVI I rlUU I rIHJ I Ub IAININLN I nt tllY FltJJtU VVFII I I tN F'tHIVI I JJIUN ANU k UNJtN I Ur CAJJ, NIAUN & RCrvrvCUY, INU. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT CITY OF CHARLOTTE STANDARDS AND SPECIFICATIONS SYMBOLS AND ABBREVIATIONS ABC AGGREGATE BASE COURSE ALUM ALUMINUM AST2 ALUMINIZED STEEL - TYPE 2 B-B BACK TO BACK BOA BLOW -OFF ASSEMBLY C&G CURB AND GUTTER CFS CUBIC FEET PER SECOND CI CURB INLET CL CENTER LINE CMP CORRUGATED METAL PIPE CO CLEAN OUT COM COMMUNICATION CONIC CONCRETE DCV DOUBLE CHECK VALVE DDCV DOUBLE DETECTOR CHECK VALVE DI DROP INLET DIP DUCTILE IRON PIPE EASE EASEMENT ELEC ELECTRIC EX EXISTING FES FLARED END SECTION FH FIRE HYDRANT FM FORCE MAIN FT FEET FT/SEC FEET PER SEC GALV GALVANIZED GV GATE VALVE HDPE HIGH DENSITY POLYETHYLENE L LENGTH LF LINEAR FEET MH MANHOLE PAVE PAVEMENT PE FINISHED PAD ELEVATION PP POWER POLE PVC POLYVINYL CHLORIDE R RADIUS R/W RIGHT-OF-WAY RED REDUCER RCP REINFORCED CONCRETE PIPE RPZ REDUCED PRESSURE ZONE SS SANITARY SEWER STA STATION TDD TEMPORARY DIVERSION DITCH TELE TELEPHONE TSB TEMPORARY SEDIMENT BASIN UG UNDERGROUND WCR WHEELCHAIR RAMP W/L WATER LINE WM WATER METER YI ON MUST YARD INLET I TY p� p �(IL �o ¢Z ym 7 y BEFORE YOU DIG! CONTACT ONE -CALL CENTER 1-800-632-4949 CONSTRUCTION NOTES M EXISTING CURB INLET ❑ EXISTING GRATE INLET/YARD INLET o EXISTING FLARED END SECTION EXISTING FIRE HYDRANT oa-o EXISTING BLOW -OFF ASSEMBLY oa EXISTING GATE VALVE EXISTING REDUCER ❑ EXISTING WATER METER O EXISTING SAN SEWER MANHOLE o EXISTING CLEAN OUT r0i EXISTING POWER POLE ❑ EXISTING TELEPHONE PEDESTAL EXISTING AREA LIGHT EXISTING SIGN u NEW CURB INLET NEW GRATE INLET/YARD INLET no NEW FLARED END SECTION NEW FIRE HYDRANT ►�� NEW BLOW -OFF ASSEMBLY ►� NEW GATE VALVE ► NEW REDUCER o NEW WATER METER I -I NEW TEE In NEW PLUG • NEW MANHOLE • NEW CLEAN OUT _W_ NEW SIGN a IRON PIPE BENCHMARK TEMP SILT FENCE SHEET INDEX COUNTRYWOODS COVER C3.1 EROSION CONTROL PLAN (STAGE 1) -ENLARGED C4.1 SIGHT DISTANCE PLAN & PROFILE MOBILE HOME PARK PHASE 1 C5.1 DETAILS C5.2 DETAILS 5201 VICTORIA AVENUE C5.3 NCG01 DETAILS 1PF 1PF TEMP TREE PROTECTION FENCE IN TEMP COMBINATION SILT/TREE PROTECTION FENCE TPF TEMP DIVERSION DITCH • DISTURBED LIMITS - • STREAM • ••• - - c - - - c EXISTING GAS LINE - - COM - - - COM EXISTING COMMUNICATIONS LINE - - r - - - r EXISTING UNDERGROUND TELEPHONE - - E - - - E EXISTING UNDERGROUND ELECTRIC - - OHE - - - OHE EXISTING OVERHEAD ELECTRIC - - W - - - W EXISTING WATER LINE - _FM - - - FM EXISTING SANITARY SEWER FORCE MAIN - - ss - - - ss EXISTING SANITARY SEWER --------------- EXISTING STORM DRAINAGE NEW STORM DRAINAGE NEW WATER LINE NEW SANITARY SEWER NEW SANITARY SEWER FORCE MAIN FM FM NEW GAS MAIN G G • • • • • • • • • • • • • • • HANDICAPPED ACCESSIBLE ROUTE NOTE: ALL CONSTRUCTION ACTIVITY MUST BE IN ACCORDANCE WITH THE ACCEPTED POLICIES OF THE CITY OF CHARLOTTE AND NCDOT NOTE: SITE CANNOT BE SUBDIVIDED FOR INDIVIDUAL LOTS 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH APPLICABLE MUNICIPALITY STANDARDS, SPECIFICATIONS, AND DETAILS. WORK IN THIS PROJECT SHALL ALSO CONFORM TO THESE PLANS, THE LATEST EDITIONS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT) ROAD AND BRIDGE SPECIFICATIONS, THE ROAD AND BRIDGE STANDARDS, THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK, THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL REGULATIONS, THE FINAL GEOTECHNICAL REPORT, AND GENERAL DESIGN STANDARDS. IN THE EVENT OF CONFLICT BETWEEN ANY OF THESE STANDARDS, SPECIFICATIONS, OR PLANS, THE MOST STRINGENT SHALL GOVERN. 2. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR TRENCH SAFETY DURING ALL PHASES OF CONSTRUCTION. 3. THE LOCATION AND SIZE OF EXISTING UTILITIES AS SHOWN IS APPROXIMATE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR HORIZONTALLY AND VERTICALLY LOCATING AND PROTECTING ALL PUBLIC OR PRIVATE UTILITIES WHICH LIE IN OR ADJACENT TO THE CONSTRUCTION SITE. AT LEAST 48 HOURS PRIOR TO ANY DEMOLITION, GRADING, OR CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL NOTIFY THE NORTH CAROLINA ONE -CALL UTILITIES LOCATION SERVICE (ULOCO) AT 1-800-632-4949 FOR PROPER IDENTIFICATION OF EXISTING UTILITIES WITHIN THE SITE. 4. THE CONTRACTOR SHALL SALVAGE AND PROTECT ALL EXISTING POWER POLES, SIGNS, MANHOLES, TELEPHONE RISERS, WATER VALVES, ETC. DURING ALL CONSTRUCTION PHASES. THE CONTRACTOR SHALL REPAIR, AT HIS OWN EXPENSE, ANY EXISTING UTILITIES DAMAGED DURING CONSTRUCTION. 5. TRAFFIC CONTROL ON PUBLIC STREETS SHALL BE IN CONFORMANCE WITH THE TRAFFIC CONTROL PLAN, THE "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES," AND AS FURTHER DIRECTED BY CITY AND STATE INSPECTORS. 6. ANY DISCREPANCIES FOUND BETWEEN THE DRAWINGS AND SPECIFICATIONS AND SITE CONDITIONS OR ANY INCONSISTENCIES OR AMBIGUITIES IN DRAWINGS OR SPECIFICATIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER, IN WRITING, WHO SHALL PROMPTLY ADDRESS SUCH INCONSISTENCIES OR AMBIGUITIES. WORK DONE BY THE CONTRACTOR AFTER HIS DISCOVERY OF SUCH DISCREPANCIES, INCONSISTENCIES, OR AMBIGUITIES SHALL BE DONE AT THE CONTRACTOR'S RISK. 7. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR SHALL ARRANGE THE MEETING WITH THE CITY ENGINEERING DIVISION. 8. ALL AREAS SHALL BE GRADED FOR POSITIVE DRAINAGE, AND AS SHOWN ON THESE PLANS. THE CONTRACTOR SHALL MAINTAIN ADEQUATE SITE DRAINAGE DURING ALL PHASES OF CONSTRUCTION. THE CONTRACTOR SHALL USE SILT FENCES (OR OTHER METHODS APPROVED BY THE ENGINEER AND APPLICABLE MUNICIPALITY) AS REQUIRED TO PREVENT SILT AND CONSTRUCTION DEBRIS FROM FLOWING ONTO ADJACENT PROPERTIES. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE, OR LOCAL EROSION, CONSERVATION, AND SILTATION ORDINANCES. CONTRACTOR SHALL REMOVE ALL TEMPORARY EROSION CONTROL DEVICES UPON COMPLETION OF PERMANENT DRAINAGE FACILITIES AND THE ESTABLISHMENT OF A STAND OF GRASS OR OTHER GROWTH TO PREVENT EROSION. CITY OF CHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINA PROGRESS DRAWINGS APPROVALS PENDING CITY OF CHARLOTTE PROJECT NO. TBD 9. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEER'S SPECIFICATIONS. THE FILL MATERIAL TO BE USED SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 10. MATERIALS USED TO CONSTRUCT EMBANKMENTS FOR ANY PURPOSE, BACKFILL AROUND DRAINAGE STRUCTURES, OR IN UTILITY TRENCHES FOR ANY OTHER DEPRESSION REQUIRING FILL OR BACKFILL SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST AS SET OUT IN ASTM STANDARD D698. STONE BACKFILL SHALL BE COMPACTED TO 95% MAXIMUM DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST AS SET OUT IN ASTM STANDARD D1557. THE CONTRACTOR SHALL, PRIOR TO ANY OPERATIONS INVOLVING FILLING OR BACKFILLING, SUBMIT THE RESULTS OF THE PROCTOR TEST TOGETHER WITH A CERTIFICATION THAT THE SOIL TESTED IS REPRESENTATIVE OF THE MATERIALS TO BE USED ON THE PROJECT. TESTS SHALL BE CONDUCTED BY A CERTIFIED MATERIALS TESTING LABORATORY AND THE CERTIFICATIONS MADE BY A LICENSED PROFESSIONAL ENGINEER REPRESENTING THE LABORATORY. 11. PROPOSED CONTOURS AND GUTTER GRADIENTS ARE APPROXIMATE. PROPOSED SPOT ELEVATIONS AND ROADWAY PROFILES/SUPERELEVATIONS ARE TO BE USED IN CASE OF DISCREPANCY. 12. THE CONTRACTOR SHALL REVIEW, VERIFY AND COORDINATE ALL DIMENSIONS SHOWN ON PLANS, INCLUDING THE HORIZONTAL AND VERTICAL LOCATION OF CURB INLETS AND GRATE INLETS AND ALL UTILITIES CROSSING THE STORM SEWER PRIOR TO STARTING PROJECT. 13. OWNER SHALL PROVIDE FENCING AND OTHER SAFETY MEASURES NECESSARY IN AND AROUND ANY PROPOSED STORMWATER MANAGEMENT MEASURES (PONDS, WETLANDS, ETC.) OBTAINING PROPER PERMITS SHALL BE THE RESPONSIBILITY OF THE OWNER. 14. RETAINING WALLS EXCEEDING 30 INCHES IN HEIGHT SHALL INCLUDE FALL PROTECTION IN THE FORM OF A HANDRAIL OR FENCING ON THE HIGH SIDE OF THE RETAINING WALL. 15. PROPER COMPACTION OF ALL FILL SOILS PLACED ON SITE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. COMPACTION SHALL BE ADEQUATE TO SUPPORT THE PROPOSED USE OF AREAS IN WHICH FILL SOILS ARE PLACED. THE CONTRACTOR SHALL HIRE A GEOTECHNICAL ENGINEER TO TEST AND VERIFY THAT COMPACTION IS ADEQUATE FOR THE PROPOSED USE OF IN THE AREA OF FILL PLACEMENT. 16. ALL ASPECTS OF THIS PROJECT SHALL BE IN FULL COMPLIANCE WITH CURRENT ADA STANDARDS. IF THE CONTRACTOR NOTES ANY ASPECTS OF THE PROJECT WHICH ARE NOT IN COMPLIANCE, THE ENGINEER SHALL BE NOTIFIED PRIOR TO ANY FURTHER WORK BEING PERFORMED. ANY WORK PERFORMED AFTER THE CONTRACTOR NOTES SUCH A NON COMPLIANCE IS SUBJECT TO REMOVAL AND REPAIR AT THE CONTRACTOR'S EXPENSE. 17. THE CONTRACTOR OR OWNER SHALL EMPLOY A GEOTECHNICAL ENGINEER TO TEST ALL EMBANKMENTS AND FILL PLACEMENT FOR PROPER COMPACTION. PROPER COMPACTION SHALL BE PER THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS OR THESE PLANS, WHICHEVER IS MORE STRINGENT. EMBANKMENTS FOR PONDS SHALL BE PLACED IN 6 INCH LOOSE LAYERS AND SHALL BE COMPACTED I / SITE VICINITY MAP N.T.S. W I! V__ TO A DENSITY OF NO LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE CONTENT OF + OR - TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D698. THE CONTRACTOR SHALL TAKE PHOTOGRAPHS OF THE OUTLET STRUCTURE AT ALL AT ALL PHASES OF INSTALLATION AND SHALL RETAIN WITH GEOTECHNICAL TESTING DATA. THE CONTRACTOR SHALL ALSO RETAIN ALL SHIPPING RECORDS AND SPECIFICATIONS FOR THE OUTLET STRUCTURE MATERIALS AND STRUCTURES. ALL OF THE ABOVE DATA MAY BE REQUIRED AS PART OF THE MUNICIPALITY AS -BUILT PROCESS AND SHALL BE MADE AVAILABLE TO THE ENGINEER UPON REQUEST. THE CONTRACTOR AND OWNER SHALL HAVE DOCUMENTATION OF THESE TESTS AVAILABLE UPON REQUEST. 18. RETAINING WALLS SHOWN HEREIN SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER WITH EXPERIENCE DESIGNING RETAINING WALLS. AT LEAST 14 DAYS PRIOR TO BEGINNING CONSTRUCTION OF RETAINING WALLS THE CONTRACTOR SHALL CONTACT THE OWNER'S GEOTECHNICAL ENGINEER TO SCHEDULE AND COORDINATE ALL APPROPRIATE INSPECTIONS, TESTING, AND VERIFICATION NECESSARY DURING RETAINING WALL CONSTRUCTION. THE GEOTECHNICAL ENGINEER SHALL PROVIDE CONTINUOUS INSPECTION, TESTING AND VERIFICATION FOR THE DURATION OF RETAINING WALL CONSTRUCTION. PROPER SCHEDULING, EXECUTION, AND RECORD KEEPING FOR ALL REQUIRED INSPECTIONS, TESTING, AND VERIFICATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. SUCH RECORDS SHALL BE RETAINED AND SHALL BE PROVIDED TO THE OWNER AND BASS, NIXON & KENNEDY, INC. ALL MONITORING, TESTING, AND VERIFICATION SHALL CONFORM TO THE MOST RECENT VERSION OF THE NC BUILDING CODE CHAPTER 18, SECTION 1806 OR THE WALL DESIGN ENGINEER'S SPECIFICATIONS, WHICHEVER IS MORE STRINGENT. wwT N� ARR/S 1140. ENGINEER: I m 0[N BASS, NIXON & KENNEDY, INC. CONSULTING ENGINEERS 6310 CHAPEL HILL ROAD, SUITE 250 RALEIGH, NORTH CAROLINA 27607 TELEPHONE: (919) 851-4422 FAX: (919) 851-8968 CERTIFICATION NUMBERS: NCBELS (C-0110) NCBOLA (C-0267) CONTACT: MARTY D. BIZZEL, PE CPESC EMAIL: Marty.Bizzel@BNKinc.com PCSO SUMMARY Original Parcel ID Number(s): 3724101 Development Type: Commercial Subject to PCSO? Y/N Y If NO, why? -- Click for Dropdown -- Watershed: Western Catawba Disturbed Area (ac): 11.05 Site Area (ac): 27.59 DA# 1 DA#2 Total on -site Drainage Area (ac): 27.59 Existing Built -upon -area (SF): 51,401 Existing BUA to be removed (SF): 0 Existing BUA to remain (SF): 51,401 Proposed New BUA (SF): 169,448 Proposed % BUA: 14.1 Density (High / Low) High Total Post -Project BUA for site: 220,849 Development or Redevelopment? Redevelopment Natural Area Required (ac): 6.9 Natural Area provided, total (ac): 13.36 Undisturbed Treed Natural Area Preserved (ac): 13.36 Total stream buffer protected on -site (ac): 6.74 Transit Station Area? Y/N N Distressed Business District? Y/N N Mitigation Type (if applicable) 85% TSS Natural Area mitigation? Y/N N Buffer Mitigation? Y/N N Total Phosphorous Mitigation? Y/N N OWNER/DEVELOPER: ,,�pnnpq�... O pF E / 03 0 .l; D. B� L Vd 09/09/22 KDM DEVELOPMENT CORPORATION 1080 PITTFORD VICTOR RD. P I TTS FO R D, NC 14535 CONTACT: KENYON BURNHAM PHONE: 585-465-0099 EMAIL: KBURNHA@U.ROCHESTER. EDU 0 z U w 0 a W F_ H 0 MJ 1.� Q 2 U LL 0 U 0 LU z z LU Ca O >G z N m J H H m cc z J LU cc IL a LU O 2 LU J_ m 2 O O cc H z M U r RT O r N 6 0