HomeMy WebLinkAboutGW1-2022-09417_Well Construction - GW1_20221007 WELL CONSTRUCTION RECORD For Internal Use ONLY: This form can be used for single or multiple wells 1.Well Contractor Information: Billy J. Payne Jr. FROM TO DESCRIPTION Well Contractor Name 12 f' 19 ft non-potable water 4532-B ft. ft. NC Well Contractor Certification Number FROM TO DIAMETER THICKNESS MATERIAL Excel Civil & Environmental Associates, PLLC ft. ft in. Company Name WI#0300474 SIP#70003023 FROM TO DIAMETER THICKNESS MATERIAL 2.Well Construction Permit#: 0 fL 9 ft. 2 in. 0.154" Sch 40 PVC List all applicable well permits(i.e.County,State, variance,Injection,etc) ft. CL in. 3.Well Use(check well use): Water Supply Well: ;Of, TO DIAMETER SLOT SIZE THICKNESS MATERIAL ❑Agricultural ❑Municipal/Public 9 ft' 2 1n. 0.10 0.154" Sch 40 PV❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ft. in. ❑IndustriaUComme al €irQRdM` ntial Water Supply(shared) TO MATERIAL EMPLACEMENT METHOD&AMOUNT ❑hri a[ion ��,��-. �,T°nw� �„ -� fL Non-Water Supply Well: ^ 4 Cement Tremie pipe flow w/vibration ❑Monitoring OCT 0 j 20Z?Recovery 4 ft. 6 rt. Sand/Cement Consolidation/Hydration Injection Well: Una 6 ft. 19 ft. #2 Sand ConsolidationNibration ❑Aquifer Rechargtl triO�r,. ^= 1` ^` Groundwater Remediation FROM TO MATERIAL EMPLACEMENT METHOD ❑Aquifer Storage and Recovery ❑Salinity Barrier 6 ft. 19 ft. #2 Silica Sand Consolidation/Vibration ❑Aquifer Test ❑Stormwater Drainage ft. ft. ❑Experimental Technology ❑Subsidence Control ❑Geothermal(Closed Loop) ❑Tracer FROM TO DESCRIPTION color,hardness soil/mck type,grain size,etc. ❑Geothermal(Heating/Cooling Return) ❑Other(explain under#21 Remarks) 0 ft' 1 ft Concrete/Gravel 4.Date Well(s)Completed: Well ID# 9-28-22 IW-4 1 ft. 4 ft. Dk. Red Brn Silty Clay(Moist) 4 ft• 8 ft. Red Brn.Silty Clay(Moist) 5a.Well Location: 8 ft• 12 ft. Org. Red Brn.Silty Clay(Moist) Sam's Mart No. 25 00-0-0000013875 12 ft• 16 ft Org. Red Brn.Silty Clay(Very Moist) Facility/Owner Name Facility ID#(if applicable) 16 ft- 19 ft. Dk. Red Brn Silty Clay(Wet) 6201 N. Tryon Street, Charlotte, 28212 19 ft. 19 ft. Termination Physical Address,City,and Zip Mecklenburg County 08923217 Injection well for GW rmediation utilizing Klozur(See detail notes) County Parcel Identification No.(PIN) 5b.Latitude and Longitude in degrees/minutes/seconds or decimal degrees: 22•Cer• cation: (if well field,one lat/long is sufficient) 35.271363 N -80. 767989 W 9/30/2022 gnature of Ce I Well Cimlracl.rl Date 6.Is(are)the well(s): ©Permanent or ❑Temporary By signing this form,I hereby certify that the well(s)was(were)constructed in accordance with 15A NCAC 02C.0100 or 15A NCAC 02C.0200 Well Construction Standards and that a 7.Is this a repair to an existing well: ❑Yes or 0No copy of this record has been provided to the well owner. Ifthis is a repair,fill out known well construction information and explain the nature of the repair under#21 remarks section or on the back of this form. 23.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well 8.Number of wells constructed: 1 construction details. You may also attach additional pages if necessary. For multiple injection or non-water supply wells ONLY with the same construction,you can submit one form. SUBMITTAL INSTUCTIONS 9.Total well depth below land surface: 19 (ft.) 24a. For All Wells: Submit this form within 30 days of completion of well For multiple wells list all depths if dierent(example-3@200'and 2@I001 construction to the following: 10.Static water level below top of casing: 12 (ft.) Division of Water Resources,Information Processing Unit, Ifwater level is above casing,use"+" 1617 Mail Service Center,Raleigh,NC 27699-1617 11.Borehole diameter: 4.25 0/2"I (i°) 24b.For Infection Wells ONLY: In addition to sending the form to the address in 4.25" auger-method 24a above, also submit a copy of this form within 30 days of completion of well 12.Well construction method: construction to the following: (i.e.auger,rotary,cable,direct push,etc.) Division of Water Resources,Underground Injection Control Program, FOR WATER SUPPLY WELLS ONLY: 1636 Mail Service Center,Raleigh,NC 27699-1636 13a.Yield(gpm) Method of test: 24c.For Water Supply&Injection Wells: Also submit one copy of this form within 30 days of completion of 13b.Disinfection type: Amount: well construction to the county health department of the county where constructed. Form GW-1 North Carolina Department of Environment and Natural Resources-Division of Water Resources Revised August 2013 PROJECT: SM25 6201 N TRYON ST., MODIFIED 8"-0 X 12"-D STEEL WELL ID. NO. CHARLOTTE, N.C. MANHOLE W/ MIN 18" X 18" WELL SIP # 70003023 CONCRETE PAD INJECTION WELL WELL CONST. # W10300474 (PAD WILL BE SLOPED TO MATCH NCWC # 4532—B EXISTING GRADE SLOPE) GRADE - 0' : . •; ,. LAYER #I-6" CONCRETE 0.5 • • ,: .r, • ° LAYER #2-6" CONCRETE . 0.5 q ° , -2" PVC CASING x� �•� WELL SEAL NEAT CEMENT y` 4'-6' BGL / CONCRETE - - - - - - - - SAND PACK 6' — 19' BGL BENTONITE HOLE PLUG 2" PVC SCREEN ` 9' — 19' BGL UNDISTURBED EARTH TOXIC SAFETY INFORMATION Product Name: Klosur®SP Product CAS-No: 7775-27-1 #2 SILICA SAND Synonyms: 20-28 SLOT Sodium Persulfate; Sodium Peroxydisulfate; Disodium Peroxydisulfate; Peroxydisulfuric acid, GRAVEL PACK disodlium salt; (IF APPLICABLE) Peroxydisulfuric acid, SOIL LITHOLOGY SOdIUm Salt. Alternate Commercial TOTAL DEPTH Name:Klosur®Persulfate o.s' CONCRETE 19' BGL Manufacturer/Supplier: LAYER #1 — — — — — - PeroxyChem LLC —CONCRETE 2005 Market St Suite 3200 LAYER #2 Piilaelphia, PA 19103 TYPE II PERMANENT +1 (267)-422-2400 0.5' GRAVEL INJECTION WELL sdsinfo@peroxychem.com Emergency No. for leak IB' CONSTRUCTION or fire, spill or accident call: SILTY CLAY BRN. (TAN) 1 (800)-424-9300 SIL DETAIL Medical: 1 (303) 389-1409 BRN . (TYPICAL - N.T.S.) 33' SILTY CLAY WEATHERED ROCK IT MAY BE NECESSARY TO MODIFY SOME/ALL OF THE MANHOLES BY TRIMMING THE METAL ENVLOSURE. WE PROPOSE TO ALTER THE EMCO WHEATOW A0721 MONITOR WELL MANHOLE BY CUTTING THE HEIGHT OF THE MANHOLE DOWN TO APPROXIMATELY 6—INCHES TO CONFORM TO • THE EXISTING LAYER OF CONCRETE BECAUSE THERE IS 2—LAYERS OF 6—INCH THICK CONCRETE 35' LT. BRN ONSITE WHERE THE PROPOSED INJECTION WELLS ARE TO BE INSTALLED. IT WILL BE VERY WEATHERED ROCK DIFFICULT FOR US TO CUT INTO THE SECOND LAYER OF CONCRETE SO WE PROPOSE TO ALTER THE MANHOLE HEIGHT TO ACCOMMODATE THE THICKNESS OF THE EXISTING CONCRETE THICKNESS. F:NC/PROJECTS/WELL INSTALL/SM25-CONSTDTL_9/6/22