Loading...
HomeMy WebLinkAboutSW5220102_Supplement-EZ Form_20220504SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name 2 Project Area (ac) 3 Coastal Wetland Area ac 4 Surface Water Area (ac) 5 Is this project Hi h or Low Density? 6 Does this project use an off -site SCM? NASH SOLAR ARRAY 318 0 7.6 No COMPLIANCE WITH 02H.1003(4) 7 Width of ve etated setbacks provided feet 50 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? N/A 10 Is streambank stabilization proposed on thisproject? No DE 1 u� Y 0 "12022 -LAIND QUALITY ffORMWATER PERM T I NNJ NUMBER 11 AND TYPE OF SCMs: Infiltration System 0 Bioretention Cell 0 Wet Pond 0 Stormwater Wetland 0 12 13 14 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting (RWH) 0 18 Green Roof 0 19 Level Spreader -Filter Strip (LS-FS) 0 20 Disconnected Impervious Surface (D>S) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 _ Bayfilter 0 26 Filterra 0 FORMS LOADED ESIGNER CERTIFICATION 27 Name and Title: _ GREGORY R. HOFFM_AN, P.E. 28 Organization: CIVIL DESIGN CONCEPTS, PA 29 Street address: 168 PATTON AV_E _ 30 City, State, Zip: ASHEVILLE, NC 28801 31 Phone numbers : 828 252-5388 32 Email: GHOFFMAN CDCGO.COM Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. \�ttllltlll///// o�oFss/�f �:` a o SEAL 0 035093 0 2 0 IWIt- Sign/re of Designer Date S-�-et DRAINAGE AREAS 1 Is this a high density project? No 2 If so, number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so, number of low density drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE 4 AREA INFORMATION Type of SCM Entire Site N/A LD 1 N/A 5 Total drainage area (sq ft 13852080 13852080 6 Onsite drainage area sq ft 13852080 13852080 7 Offsite drainage area sq ft) N/A : N/A 8 Total BUA in project (sq ft) 310858 sf 310858 sf 9 New BUA on subdivided lots (subject to permiin sq ft N/A N/A 10 New BUA not on subdivided lots (subject to permitting) sf 310858 sf 310858 sf 11 Offsite BUA s ft N/A ' N/A 12 Breakdown of new BUA not on subdivided lots: Parking (sq ft) N/A N/A - Sidewalk sq ft N/A N/A Roof sq ft N/A N/A Roadway s ft 238904 sf 238904 sf - Future sq ft N/A N/A - Other, please specify in the comment box below (sq ft) 71954 sf 71954 sf 13 New infiltrating permeable pavement on subdivided lots (sq ft) N/A N/A 14 New infiltrating permeable pavement not on subdivided lots (sq ft) N/A N/A 15 Existing BUA that will remain (not subject to permitting) (sq ft) N/A N/A 16 Existing BUA that is already permitted (sq ft) N/A N/A 17 Existing BUA that will be removed s ft 64538 sf 64538 sf 18 Percent BUA 2% 2% 19 Design storm (inches) 6.8 in 6.8 in 20 Design volume of SCM (cu 8) N/A N/A 21 Calculation method for deli n volume RATIONAL RATIONAL ADDITIONAL 'INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): Transformer Pads RLJA and Substation BI IA included in "Other" section. 1440 square feet for the 9 inverter pads and 70514 square feet for the substation pad. LOW DENSITY DESIGN 1 REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 021-1.1003 is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per .1 0032 c ? Yes ' 4 Side slopes of the vegetated conveyances H:V 3:1) 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 5.43 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (% ' N/A 8 Bottom width of curb outlet swales feet N/A = 9 Maximum side slope of curb outlet swale(s) (H:V) N/A 10 Minimum length of curb outlet Swale(s) feet N/A" 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? N/A 13 1 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 ADDITIONAL 15 Are variations to rule .1003 proposed? INFORMATION 1 Please use this space to provide any additional information about this low densityproject: No = Drainage Pervious Swale Area BUA area # ac) (ac) ac 1 2.43 0.00 2.43 C 0.60 Q Slope (cfs) N 9.93 5.60 V.11.. (fps) 9.50 V, .i Flow depth (fps) (ft) 5.43 ' 0.59 2 3 4 5 6 7 g 9 10 11 12 13 14 15 16 17 18 20 22 24 25 26 27 28 29 30