Loading...
HomeMy WebLinkAboutNC0023191_Compliance Evaluation Inspection_20221005ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director David Millsaps Seven Cedars MHP P.O. Box 1143 Statesville, NC 28687 SUBJECT: Compliance Evaluation Inspection Seven Cedars MHP WWTP NPDES Permit No. NC0023191 Iredell County Dear Mr. Millsaps: NORTH CAROLINA Environmental Quality October 5, 2022 Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the subject facility on September 28, 2022, by Mr. Wes Bell of this Office. Please advise the facility's Operator -in -Responsible Charge (ORC) of our findings by forwarding the enclosed report. Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192 or at wes.bell@ncdenr.gov. Enclosure: Inspection Report Cc: NPDES Program Files - Laserfiche DILLORIN _E Sincerely, DocuSigned by: AwHP► F161FB69A2D84A3... Andrew H. Pitner, P.G. Assistant Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1610 East Center Avenue. Suite 301 1 Mooresville. North Carolina 28115 704.663.1699 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 21IIIIII L NPDES yr/mo/day Inspection 3 I NC0023191 111 121 22/09/28 117 Type 181 I IIIIIIIIIII Inspector Fac Type 19 I S I 201 1 IIIIIIIIIIIIIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67I2.0 I 70I4 I 71IN I 72 I N I 731 1 74 751 I I 1 I I I I I I 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Seven Cedars Mobile Home Park WWTP Village Dr Statesville NC 28677 Entry Time/Date 11:15AM 22/09/28 Permit Effective Date 20/05/01 Exit Time/Date 12:45PM 22/09/28 Permit Expiration Date 24/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Daniel Gatewood//704-848-4849 / David Lynn Millsaps//704-872-8552 /7048725515 Todd Franklin Robinson/ORC/704-881-4598/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted David Lynn Millsaps,PO Box 1143 Statesville NC 286870827//704-872-8552/7048725515 Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Wes Bell of Inspector(s) Agency/Office/Phone and Fax Numbers Date —Docusigned by: DWR/MRO WQ/704-663-1699 Ext.2192/ 10/5/2022 "-A61696D90CC3437... Signature of ManfrRRfei`A*6itiewer Andrew Pitney Agency/Office/Phone and Fax Numbers Date A. H 10/5/2022 R/MRO WQ/704-663-1699 Ext.2180/ F161FB69A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 NPDES yr/mo/day 31 NC0023191 111 121 22/09/28 I17 Inspection Type 18 [j 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# 2 Permit: NC0023191 Inspection Date: 09/28/2022 Owner - Facility: Seven Cedars Mobile Home Park WWTP Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new El El • ❑ application? Is the facility as described in the permit? • El El El # Are there any special conditions for the permit? El El • El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • El El El Comment: Overall, the wastewater treatment facility is adequately described in the permit; however, a chlorine contact tank with tablet chlorinator has not been installed. These treatment units should be removed during the next permit renewal process unless effluent fecal coliform monitoring/limits are imposed. The last compliance evaluation inspection at this facility was performed by DWR staff on 7/16/20. Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ • ❑ Page# 3 Permit: NC0023191 Inspection Date: 09/28/2022 Owner - Facility: Seven Cedars Mobile Home Park WWTP Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Comment: The records reviewed during the inspection were organized and well maintained. Discharge Monitoring Reports (eDMRs) were reviewed for the period August 2021 through July 2022. Daily maximum effluent TSS violations were reported in February and April 2022. The Division has previously addressed these limit violations through the issuances of NOV/civil penalty assessments. The ORC and staff must ensure that the time (military or standard) is properly labeled on the chain of custody forms. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Comment: On -site field analyses (pH and temperature) are performed under Envirolink's field laboratory certification #5212. Statesville Analytical has also been contracted to provide analytical support. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ El • El Is sample collected below all treatment units? El • El El Is proper volume collected? El El • El Is the tubing clean? ❑ ❑ • ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 El El • El degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • El El El representative)? Comment: The subject permit requires effluent grab samples. The ORC and staff must ensure to collect all future effluent samples following the gravel filtration tank (pipe inside down gradient manhole). Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The wastewater treatment facility appeared to be properly operated and well maintained. Process control measurement are being performed and documented. Page# 4 Permit: NC0023191 Inspection Date: 09/28/2022 Owner - Facility: Seven Cedars Mobile Home Park WWTP Inspection Type: Compliance Evaluation Bar Screens Yes No NA NE Type of bar screen a.Manual • b.Mechanical ❑ Are the bars adequately screening debris? • ❑ ❑ ❑ Is the screen free of excessive debris? • ❑ ❑ ❑ Is disposal of screening in compliance? • ❑ ❑ ❑ Is the unit in good condition? • ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? • ❑ ❑ ❑ Are surface aerators and mixers operational? El El • El Are the diffusers operational? • El El El Is the foam the proper color for the treatment process? • El El El Does the foam cover less than 25% of the basin's surface? • El El El Is the DO level acceptable? • El El El Is the DO level acceptable?(1.0 to 3.0 mg/I) • El El El Comment: Lime is added on an as -needed basis to maintain appropriate alkalinity/pH levels. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ II ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ Page# 5 Permit: NC0023191 Inspection Date: 09/28/2022 Owner - Facility: Seven Cedars Mobile Home Park WWTP Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Instantaneous flows are measured by the bucket and stopwatch method. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: The effluent appeared clear with no floatable solids or foam. Aerobic Digester Is the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Yes No NA NE ❑ ❑ • ❑ ❑ ❑ • ❑ Yes No NA NE ❑ ❑ ❑ • ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: The facility is equipped with multiple aerated sludge holding tanks. Lentz Septic Service has been contracted for the removal and disposal of sludge. Page# 6