HomeMy WebLinkAboutSW1221001_Supplement-EZ Form_20221004WET POND
11
Drainage area number
1
2
Minimum required treatment volume cu ft
21939 cf
GENERAL MDC FROM 02H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
No
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
31
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
7
Are the inlets, outlets, and receiving stream protected from erosion (10-
year storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
9
What is the method for dewatering the SCM for maintenance?
Drawdown Orifice
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
N/A
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
151
Is there an O&M Plan that complies with General MDC (12)?
Yes
161
Does the SCM follow the device specific MDC?
Yes
17
Was the SCM desi ned by an NC licensedprofessional?
Yes
WET POND
MDC FROM 02H .1053
18
Sizing method used
SAIDA
19
Has a stage/storage table been provided in the calculations?
Yes
20
Elevation of the excavated main pool depth (bottom of sediment
removal) (fmsl)
2572.00
21
Elevation of the main pool bottom (top of sediment removal) (fmsl)
2572.50
22
Elevation of the bottom of the vegetated shelf (fmsl)
2576.50
231
Elevation of the permanent pool (fmsl)
2576.50
24
Elevation of the top of the vegetated shelf (fmsl)
2577.50
25
Elevation of the temporary pool fmsl
2577.90
26
Surface area of the main permanent pool (square feet)
10869
27
Volume of the main permanent pool (cubic feet)
36447 cf
28
Average depth of the main pool (feet)
3.35 ft
29
Avera e depth euation used
Equation 2
30
If using equation 3, main pool perimeter (feet)
311
If using equation 3, width of submerged veg. shelf (feet)
32
Volume of the forebay (cubic feet)
6447 cf
33
Is this 15-20 % of the volume in the main pool?
Yes
34
Clean -out depth for forebay (inches)
6 in
35
Design volume of SCM cu ft
36447 cf
36
Is the outlet an orifice or a weir?
Orifice
37
If orifice, orifice diameter inches
8 in
38
If weir, weir height (inches)
39
If weir, weir length (inches)
401
Drawdown time for the temporary pool (days)
3.6
41
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting?
Yes
42
Are berms or baffles provided to improve the flow path?
Yes
43
Depth of forebay at entrance (inches)
54 in
44
Depth of forebay at exit (inches)
42 in
45
Does waterflow out of the forebay in a non -erosive manner?
Yes
46
Width of the vegetated shelf (feet)
6 ft
471
SloiDe of ve etated shelf H:V
61
48
Does the orifice drawdown from below the top surface of the
ermanentpool?
Yes
49
Does the pond minimize impacts to the receiving channel from the 1-
r, 24-hrstorm?
Yes
50
Are fountains proposed? (If Y, please provide documentation that
MDC(9) is met.
No
51
Is a trash rack or other device provided to protect the outlet system?
Yes
52
Are the dam and embankment planted in non -clumping turf grass?
Yes
53
Species of turf that will be used on the dam and embankment
NCDEQ Mix 1M
54
Hasa plantinq plan been rovided for the v ietated shelf?
Yes
ADDITIONAL INFORMATION
55
Please use this space to provide any additional information about the
wet pond(s):
Wet Pond 1 10:46 AM 9/29/2022