NC0043532_Compliance Evaluation Inspection_20220902
ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Andy Lucas Stanly County 1000 N 1st Street, Suite 12 Albemarle, NC 28001 SUBJECT: Compliance Sampling Inspection West Stanly WWTP NPDES Permit NC0043532 Rowan County Mr. Lucas: NORTH CAROLINA Environmental Quality September 2, 2022 On August 23, 2022, Roberto Scheller of this Office conducted a compliance inspection at the subject facility. This inspection was conducted as a Compliance Sampling Inspection (CSI) to ensure compliance with permit requirements and conditions. At the time of inspection samples were collected for BOD, TSS, and NH3 as N and sent to the State Laboratory in Raleigh for analysis. Test results will be forwarded to you under separate cover. The subject facility appeared to be well operated and maintained; however, it was noted during inspection issues with the newly installed influent screening equipment. Screening device had a large amount of build-up on screen and the screen washing device did not appear to be operating properly. We wish to thank the operator for his assistance regarding this inspection. The enclosed report should be self-explanatory; however, should you have any questions, please contact myself or Roberto Scheller at (704) 235-2204 or roberto.scheller©ncdenr.gov. Sincerely, DocuSigned by: A4.41144, H Nut*. �F161FB69A2D84A3... Andrew Pitner, P.G., Assistant Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosure: Compliance Evaluation Inspection Report cc: Laserfiche E 0.arkl.duNrnn.Ylmrb\ North Carolina Department of Environmental Quality 1 Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 1 Mooresville. North Carolina 28115 704.663.1699 United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 IN Code I 2 L NPDES yr/mo/day Inspection Type Inspector Fac 3 I NC0043532 111 121 22/08/23 117 181 I 191 s I 2011 Type 21IIIIII IIIIIIIIIII IIIIIII I IIIIII IIIIIIIIIII P6 Inspection 671 Work Days Facility Self -Monitoring I 70 I3 Evaluation Rating I 711 B1 1 72 QA I N I 73 i I I I Reserved 74 71 I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES oermit Number) West Stanly WWTP 24939-B Barbees Grove Rd Oakboro NC 28129 Entry Time/Date 10:05AM 22/08/23 Permit Effective Date 18/12/01 Exit Time/Date 12:10PM 22/08/23 Permit Expiration Date 23/01/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Tommy Gibbons/ORC/910-605-1284/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Andy Lucas,1000 N 1st St Ste 12 Albemarle NC 28001/County Manager/704-986-3601/7049863711 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Compliance Schedules Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Roberto Scheller of Inspector(s) Agency/Office/Phone and Fax Numbers Date .-DocuSigned I�vby: � ` •, ��1'll� S.d, , ", ,,, DWR/MRO WQ/707-235-2204/9/1/2022 -91C2A007838943E... Signature of Mana Andrew Pitne @i�nayewer Agency/Office/Phone and Fax Numbers Date 414" H PAR/MRO WQ/704-663-1699 Ext.2180/ 9/2/2022 F161F969A2D84A3„ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 31 NPDES yr/mo/day N C0043532 111 121 22/08/23 117 Inspection Type 18i i (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The current permit became effective December 1, 2018 and expires on January 31, 2023. Permit is for the discharge of wastewater into the Rocky River (Outfall #002) and Long Creek (Outfall #001). Both discharge locations are classified as C waters in the Yadkin -Pee Dee River Basin. This facility expanded from 0.9 MGD to 1.2 MGD WWTP under Authorization to Construct #043532A01 and SOC S19-003. The subject inspection was conducted as a Compliance Sampling Inspection during which samples were split with WWTP operator for BOD, NH3 as N, and TSS. Analysis will be sent under seperate cover. It was noted during facility review that influent screen had a large amount of solids build-up on screen and appeared that wash cycle is not operating properly. Page# 2 Permit: NC0043532 Inspection Date: 08/23/2022 Owner - Facility: West Stanly WWTP Inspection Type: Compliance Sampling Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? • ❑ El El # Are there any special conditions for the permit? • ❑ ❑ ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: 2021-2022 Annual Report on Stanly County Utilities (SCU) website. Laboratory Are field parameters performed by certified personnel or laboratory? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE Page# 3 Permit: NC0043532 Inspection Date: 08/23/2022 Owner - Facility: West Stanly WWTP Inspection Type: Compliance Sampling Laboratory Yes No NA NE Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? II El El El • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ • ❑ Comment: Facility uses contract labs Environmental 1 (Cert.#10), Meritech (Cert.#27), and on site Field Certification (Cert.#56711. Bar Screens Yes No NA NE Type of bar screen a.Manual ❑ b.Mechanical • Are the bars adequately screening debris? ❑ • ❑ ❑ Is the screen free of excessive debris? ❑ • ❑ ❑ Is disposal of screening in compliance? • ❑ ❑ ❑ Is the unit in good condition? • ❑ ❑ ❑ Comment: Influent screen has large amount of build up on screen and appears that wash cycle is not operating properly. Grit Removal Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor? # Is disposal of grit in compliance? Comment: Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? Yes No NA NE • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE Page# 4 Permit: NC0043532 Inspection Date: 08/23/2022 Owner - Facility: West Stanly WWTP Inspection Type: Compliance Sampling Influent Sampling # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: At time of inspection influent sampler was recorded at 4 degrees C. Yes No NA NE • ❑ ❑ ❑ Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Surface Is the basin free of dead spots? • ❑ El ❑ Are surface aerators and mixers operational? • El El El Are the diffusers operational? ❑ El • ❑ Is the foam the proper color for the treatment process? ■ El El El Does the foam cover less than 25% of the basin's surface? • El ❑ ❑ Is the DO level acceptable? El El El • Is the DO level acceptable?(1.0 to 3.0 mg/I) ❑ El ❑ • Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? • El El El Are weirs level? • El El El Is the site free of weir blockage? • El El El Is the site free of evidence of short-circuiting? • ❑ ❑ ❑ Is scum removal adequate? • El El El Is the site free of excessive floating sludge? • El El El Is the drive unit operational? • El El El Is the return rate acceptable (low turbulence)? • ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? ■ El El El Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) El El El • Comment: Pumps-RAS-WAS Are pumps in place? • Yes No NA NE ❑ ❑ ❑ Page# 5 Permit: NC0043532 Inspection Date: 08/23/2022 Owner - Facility: West Stanly WWTP Inspection Type: Compliance Sampling Pumps-RAS-WAS Are pumps operational? Are there adequate spare parts and supplies on site? Comment: Disinfection -Gas Are cylinders secured adequately? Are cylinders protected from direct sunlight? Is there adequate reserve supply of disinfectant? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: Yes No NA NE • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ De -chlorination Yes No NA NE Type of system ? Gas Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ❑ • Is storage appropriate for cylinders? • ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? • ❑ ❑ ❑ Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? ❑ ❑ ■ ❑ Yes No NA NE Page# 6 Permit: NC0043532 Inspection Date: 08/23/2022 Owner - Facility: West Stanly WWTP Inspection Type: Compliance Sampling Effluent Sampling Yes No NA NE Is the tubing clean? •❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • El El El representative)? Comment: At time of inspection effluent sampler was recorded at 3.0 degrees C. Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? ■ ❑ ❑ ❑ Are all pumps present? • El El El Are all pumps operable? • El El El Are float controls operable? • ❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ ❑ ❑ • Is audible and visual alarm available and operational? El El El • Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Last calibration 11/16/2021. Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ ❑ ❑ ❑ Yes No NA NE ▪ El El El Page# 7 Permit: NC0043532 Inspection Date: 08/23/2022 Owner - Facility: West Stanly WWTP Inspection Type: Compliance Sampling Compliance Schedules Is there a compliance schedule for this facility? Is the facility compliant with the permit and conditions for the review period? Comment: Facility under SOC S19-003. Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Yes No NA NE ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ Page# 8