HomeMy WebLinkAboutNCC223352_Site Plan or Location Map_20220927OWNER CONTACT
OWNER: SELF HELP
OWNER CONTACT• ASPEN ROMEM - PROTECT MANAGER
ADDRESS: 301 W MAN STREET, DURHAM NC 27701
PHONE. 919-313-8565
EMAIL: ASPEN.ROMEMOSELF-HELRORG
PROJECT TEAM
ARCHITECTURAL
UIWAHCHIIEU15
229 NORTH GREGSON STREET
DURHAM, NC 27701
CIVIL ENGINEERING AND
LANDSCAPE ARCHITECTURE
CLH DESIGN, PA
400 REGENCY FOREST DR., STE. 120
CARY, NC 27518
Project Data Sheet
Planning and Development Customer Service Center • One Exchange Plaza, Suite 400 1 Raleigh, NC 27601 1 919-996-2500
This form must be completed and appi led to the cover sheet of drawings submitted with a Non -Residential building
permit associated with a Site Permit Review, or permits for an apartment, office, and/or commercial uses.
GENERAL INFORMATION
Development Name: Beacon Point
Proposed Use: Commercial
Property Add ress(es): 1440 Rock quarry Road, Raleigh, NC 2-7610
Approved Site Plan or Subdivision case #: ASR-0023-2021
Wake County Property Identification Number(s) (PIN) for each parcel to which these guidelines will apply:
PIN #:1713310403
PIN #: 1713310493
PIN 9: 1713310493
PIN #: 1713319493
❑
Apartment
Bank
❑
Congregate care
❑
Hospital
Hotel/Motel
Industrial building
Muted residential
'
Non-residential condo
What is the
project type?
'1
Q
Office
School
❑
Religious institution
Shopping center
❑
Residential condo
Single-family
residential
❑
Retail
Telecommunication
tower
❑
❑
TownhouseOther
Civic use: Park communitycenter, museum or
government facility
❑
Scope of vlork: This project will consist of the new construction of a credit union and a multi -use building which includes a cafe,
multiple health clinics and office space. The necessary site improvements include, but are not limited to, building
construction, parking lot and drive additions, wall construction, mass grading, water and sewer utility extensions,
storm►nrater infrastructure installation, and landscaping.
FOR APARTMENTS, CONDOS, AND TOWNHOMES ONLY
1. Total number of townhouse lots: Number attached: Number detached:
2. Total number of apartment or condominium units:
3. Total number of Congregate Care or Life Care Dwelling
units:
4. Overall total number of dwelling units (from 1-3 above):
5. Number of bedroom units: 1BR: 2BR:
3BR: 4BR or more:
6. Overall unit(s) per acre densities per zoning district(s):
DEVELOPMENT TYPE AND SITE DATA TABLE lapplicalsle to all developments)
_ Zoning Information
Zoning district (s): CX-5-PLA.15 ac & IX-3-PL:0.44 ac
Building Information
Proposed use of buiIding(s):Corn mercial
If more than one district, provide acreage of each:
Proposed sq. ft. of building(s) gross:
42,471 SF (2 buildings)
Overlay district(s): SHOD-1
Existing sq. ft. of buildings) 9ross:0
Total site acreage: 4.59 Acres
Total sq. ft. gross (existing and proposed): 42,471 (2 bulldings)
Off street parking: Required: 123 Provided: 123
Proposed height of building(s):37'-1.5"
COA (Certificate of Appropriateness) case #:
FAR (floor area ratio) %:21.2%
130A (Board of Adjustment) case # A -
Building lot coverage %:11.3%
CUD (Conditional Use District) case # Z -
Inside City Limits? Yes Q
No
❑
PAGE 1 OF 2
CITY OF RALEICH
RICHT-QF-WAY
OBSTRUCTION NOTES:
1. STREET, LANE, AND SIDEWALK CLOSURES OR DETOURS. • PRIOR TO ANY WORK THAT IMPACTS THE
RIGHT-OF-WAY OR CLOSING OF ANY STREET, LANE, OR SIDEWALK, THE CONTRACTOR MUST APPLY FOR A
PERMIT WITH RIGHT-OF-WAY SERVICES DESIGNER HAS REVIEWED AND IS COMPLIANCE WITH THE
REQUIREMENTS SET FORTH IN THE SOLIDS WASTE DESIGN MANUAL.
2. A PERMIT REQUEST WITH A TRAFFIC CONTROL AND/OR PEDESTRIAN PLAN SHALL BE SUBMITTED TO
RIGH TOFWA YSERWCESCRALDGHNC. GOV AT WWW.RALDGHNC.GOV KEYWORD RIGHT-OF-WAY SERVICES
J. PRIOR TO THE START OF WORK, THE CLIENT SHALL SCHEDULE A PRE -CONSTRUCTION MEETING WITH THE
ENGINEERING INSPECTIONS COORDINATOR TO REVIEW THE SPECIFIC COMPONENTS OF THE APPROVED PLAN,
AND ENSURE ALL PERMITS ARE ISSUED.
4. THE CITY OF RALEIGH REQUIRES AN APPROVED RIGHT-OF-WAY OBSTRUCTION PERMIT FOR WORK ON ANY
PUBLIC STREET OR SIDEWALK AND NCDOT ROAD WITHIN RALEIGH'S JURISDICTION.
5. ALL TRAFFIC CONTROL SIGNAGE AND PRACTICES SHALL ADHERE TO THE MANUAL ON UNIFORM TRAFFIC
CONTROL, AND THE LATEST EDITION OF THE NCDOT 'STANDARD SPECIFICATION FOR ROADWAY
STRUCTURES, NCDOT 'ROADWAY STANDARD DRAWING MANUAL, AND THE NCDOT SUPPLEMENT TO THE
MUTCD.
6. ALL PUBLIC SIDEWALKS MUST BE ACCESSIBLE TO PEDESTRIANS NiO ARE VISUALLY IMPAIRED AND/OR
PEOPLE WITH MOBILITY CONCERNS. EXISTING AND ALTERNATIVE PEDESTRIAN ROUTES DURING CONSTRUCTION
SHALL BE REQUIRED TO BE COMPLIANT WITH THE PUBLIC RIGHTS OF WAY ACCESSIBILITY GUIDELINES
(PROWAG), THE ADA STANDARDS FOR ACCESSIBLE DESIGN AND THE MANUAL ON UNIFORM TRAFFIC
CONTROL DEVICES (MUTCD).
Z ALL PERMITS MUST BE AVAILABLE AND VISIBLE ON SITE DURING THE OPERATION.
REVISION 11A6.20
raleighnc.gov
VICINITY MAP: 1"=400'
40
PROJECT
SITE
x
�! - _
,r
y-mow a -
tin pn�ge Cz
4r� O
a_
BEACON POIt***4T
SITE P E R/�11T P**.... E'N/ I E N/%/
'1440 ROCK QUARRY ROAD
RALEIGHNC 276'10
STORMWATER INFORMATION
Existing impervious surface., 0 acres/square feet
Proposed impervious surface: 11-92 ACJ83,700SF acreslsquare feet
Neuse River buffer: Yes
No
I Wetlands: Yes No
Flood Hazard Area: Yes
©
No
If yes, Alluvial soils: Cn (Colfax sandy loam)
Flood Study: None
FEMA Map Panel #: 3720171300J
Total disturbed area: 3.38 ACA47.350 SF acreslsquare feet
REVISION 11.16_ZO
PAGE 2 OF 2 raleighnc.gov
PUBLIC IMPROVEMENT
QUANTITY TABLE
PHASE NUMBER(S)
PHASE 1
PHASE 2
PHASE 3
NUMBER OF LOT(S)
1
LOT NUMBER(S) BY PHASE
1
NUMBER OF UNITS
N/A
LIVABLE BUILDINGS
N/A
OPEN SPACE?
YES
NUMBER OF OPEN SPACE LOTS
N/A
PUBLIC WATER (LF)
O LF
PUBLIC SEWER (LF)
O LF
PUBLIC STREET (LF) - FULL
O LF
PUBLIC STREET (LF) - PARTIAL
O LF
PUBLIC SIDEWALK (LF)
86 LF
STREET SIGNS (LF)
O
WATER SERVICE STUBS
2
SEWER SERVICE STUBS
2
CITY OF RALEICH SOLID WASTE
SERVICES REQUIRED NOTES:
1. ALL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH CITY OF RALEIGH AND/OR NCDOT STANDARDS AND
SPECIFICATIONS.
2. DESIGNER HAS REVIEWED AND IS IN COMPLIANCE WITH THE REQUIREMENTS SET FORTH IN THE SOLID WASTE DESIGN
MANUAL.
3. THE PROPOSED DEVELOPMENT PLANS TO USE THE CITY OF RALEIGH SOLID WASTE SERVICES (SWS) TO HANDLE
THEIR TRASH NEEDS
4. DUMPSTERS (REFUSE AND RECYCLE) ARE PROPOSED AT THE SOUTH END OF THE SITE
ATTENTION CONTRACTORS
The Contruction Contractor responsible for the extension of water,
sewer, and/or reuse, as approved in these plans, is responsible for
contacting the Public Works Department at (919) 996-2409,
and the Public Utilities Department at (919) 996-4540 at least twelity
four hours prior to beginning any of their construction.
Failure to notify both City Dpartments in advance of beginning
construction, will result in the issuance of monetary fines, and require
reinstallation of any water or sewer facilities not inspected as a result
of this notification failure.
Failure to call for Inspection, Install a Downstream Plug, have
Permitted Plans on the Jobsite, or any other Violation of City of
Raleigh Standards will result in a Fine and Possible Exclusion
from future work in the City of Raleigh.
AS R-0023-202-1; S PR-0253-202'1
TRIP GENERATION SUMMARY
r rip Geiser a[ivn Summxn
Daily-
Weekday AM
Weekday PM
Land Use
Intensify
Traffic
Peak Hour Trips
eak Hour Trips
(ITE Code)
(1R4)
ft h
Nph)
Enter
Exit
Enter
Exit
Coffee/Donut Shop without Drive-
Through Window**•*
1 700 sq'
755
52
49
Is
18
(936)
MedicaVDental office Building*
18.2DO sq.
633
39
12
18
45
(720)
$.
Office*
17.5DO sq.
195
32
4
15
70
(710)
ft.
Bank
4.000 sq.
- �*
47
43
54
5_2
(911]
ft.
Total Trips
1,584
170
108
105
185
Infernal Capture
(AAL 22% entering. 34% exiting
-190***
-317
-37
-18
-I9
PM 17% entering, 10% exitinpJ
Total New Trips
1,394
133
71
87
166
"Any indoor conin:on area was split between these land uses.
"Daily traffic volumes ara not provided for this land use code under IT'E methodology.
***PM rates for internal capture were applied.
""Based on ITE Trip Generation, 1011' Edition. iethodology, the results for this laud use are in people
trips, as opposed to vehicular trips. For the purposes of this trip generation, 1.7 people were assumed per
vehicular trip based on theFederai Highway Administration (THWA. 2018),
SITE DATA TABLE
PROJECT BEACON POINT
OWNER:
SELF HELP
OWNER CONTACT
ASPEN ROMEYN - PROJECT MANAGER
301 W MAIN STREET, DURHAM NC 27701
919-313-8565
A SPEN. ROMEYNOSEL F- HEL P. ORG
DESIGNER.
CLH DESIGN, PA
DESIGNER CONTACT.•
STEVE MILLER, CIVIL ENGINEER
400 REGENCY FOREST DR., SUITE 120
CARY, NC 27518
PHONE. 919-319-6716
FAX. 919-319- 7516
PROJECT ADDRESS.
1440 ROCK QUARRY ROAD, RALEIGH, NC 27610
PLANNING JURISDICTION:
RALEIGH
PIN.
1713319493
ZONING:
CX-5-PL/IX-3-PL
ZONING OVERLAY
SHOD-1 - SPECIAL HIGHWAY OVERLAY DISTRICT 1
SITE ACREAGE:
4.59 ACRES
OUTDOOR AMENITY:
lox
REQUIRED.
.459 ACRES (19,994 SF)
PROVIDED:
.47 ACRES (20,344 SF)
EXISTING USE.
VACANT/WOODED
PROPOSED USE:
MULTI -TENANT OFFICE/CAFE/HEALTH CLINIC/ART GALLERY
SINGLE TENANT BANK
AREA OF DISTURBANCE:
3.38 ACRES
IMPERVIOUS AREA:
1.92 ACRES
MAX BUILDING HEIGHT ALLOWED:
PL FRONTAGE - 90 , IX - 3 STORIES, CX - 5 STORIES
BUILDING GFA:
SINGLE TENANT. 3,997 SF
MULTI -TENANT.• 39,849 SF
SOLID WASTE MANAGEMENT
CITY DUMPSTER PICKUP (1 GARBAGE BIN, 1 RECYCLE BIN)
PRIMARY STREET.
ROCK QUARRY ROAD
SIDE STREET.•
PROMISE BEACON CIRCLE
BUILDING SETBACKS.
PARKING SETBACKS.
GENERAL BUILDING (BANK):
GENERAL BUILDING (BANK
PRIMARY STREET.
3' (IX) PRIMARY STREET.•
10' (IX)
SIDE STREET.-
3' (IX) SIDE STREET
10' (IX)
REAR.
0' OR 6' (IX) REAR.
0' OR 3' (IX)
SIDE. •
0' OR 6' (IX) SIDE.
0' OR 3' (IX)
MIXED USE BUILDING:
MIXED USE BUILDING:
PRIMARY STREET.
5' (CX) PRIMARY STREET.•
10' (CX)
SIDE STREET.•
5' (CX) SIDE STREET
10' (CX)
REAR.
0' OR 6' (CX) REAR.
0' OR 3' (CX)
SIDE. •
0' OR 6' (CX) SIDE.
0' OR 3' (CX)
BUILD TO (5-100 FT):
PROMISE BEACON CIRCLE (SIDE STREET)
REQUIRED BUILD TO AREA: 25X
PROPERTY ROW FRONTAGE. 732 FT
MINUS DUKE ENERGY EASEMENT 50 FT
MINUS COR UTILITY EASEMENT 40FT
ADJUSTED TOTAL ROW FRONTAGE = 642 FT
MULTI -USE BUILDING FACADE ROW FRONTAGE. 196 FT
BANK BUILDING FACADE ROW FRONTAGE. 179 FT
TOTAL BUILDING FACADE = 375 FT
PROPOSED BUILD TO AREA = 58X (3751642)
ROCK QUARRY ROAD (PRIMARY STREET)
REQUIRED BUILD TO AREA: 50X
PROPERTY ROW FRONTAGE. 436 FT
MINUS DUKE ENERGY EASEMENT 50 FT
MINUS COR UTILITY EASEMENT 40FT
MINUS COR TCA 265 FT
ADJUSTED TOTAL ROW FRONTAGE = 81 FT
BANK BUILDING FACADE ROW FRONTAGE. 43 FT
PROPOSED BUILD TO AREA = 53X (43181)
GROUND FLOOR ELEVATION COMPLIANCE CHART.•
BUILDING
FFE AVG BOC GRADE
SINGLE TENANT BUILDING (BANK)
227.9 224.5
MULTI TENANT BUILDING (MULTI -USE) 228.7 224.5
SITE PERMITTING APPROVAL
Water and Sewer Permits Of aonllcable
INDEX OF DRAWINGS
CIVIL
ARCHITECTURAL
C000
COVER SHEET
TI DATA SHEET
coo
ADMINISTRADVEAPPROVALACTION
2-STORY BUILDING:
C100
OVERALL PLAN
AI FIRST FLOOR PLAN
C101
STAKING PLAN
A2 2ND FLOOR PLAN
C102
UDO COMPLIANCE PLAN
A3 ELEVATIONS
C200
OVERALL EXISTING CONDITIONS & DEMO PLAN
A4 ELEVATIONS & TRANSPARENCY
C201
EXISTING CONDITIONS & DEMO PLAN
CREDIT UNION:
C300
OVERALL GRADING PLAN
AI FLOOR PLAN
C301
GRADING PLAN
A2 ELEVATIONS
C302
DRAINAGEAREAS - PRE -DEVELOPMENT
A3 ELEVATIONS & TRANSPARENCY
C303
DRAINAGEAREAS - POST -DEVELOPMENT
C400
OVERALL EROSION CONTROL PLAN
SITE LIGHTING
C401
EROSION CONTROL PLAN - INITIAL INSTALL
SITE LIGHTING PLAN - CLEAN
C402
EROSION CONTROL PLAN - FINAL INSTALL
SITE LIGHTING PLAN - (FOOT CANDLES)
C403
NPDES STABILIZATION PL4N
C500
OVERALL SITE UTILITY PLAN
RETAINING WALL
C501
SITE UTILITY PLAN
COVER SHEET
C600
OVERALL LANDSCAPE PLAN
0.0 GENERAL NOTES
C601
LANDSCAPE PLAN
1.0 PLAN
C701-C706
SITE FROSION/LANDSCAPE DET14ILS
2.0 ELEVATIONS
C801-C803
SITE UTILITY/STORM DETAILS
3.0 SECTIONS
C901-C903
SITE DETAILS
4.0 DETAILS
The City of Raleigh consents to the connection and extension of the City's Public Sewer System as shown on this plan. The
material and Construction methods used for th is project s h al I La nform to the standards and specifications of the C ity's Pu blic
Utilities Handbook. City ofFaleighPublic UtilitiesDepartmentPermit #
The City of Raleigh wnsentsto the connection and extension of the City's Public Wafer System as shown on this plan. The
material and Construction methods used forthis projectshall conform tothe standards and specifications otthe Cty's Public
EJtilities Handbook, Gityof Raleigh Public Utillttes Department Permtt#
The City of Raleigh consents to the connection to its public sewar system and extension of the private sewer collection
system as shown on this plan. The material and constructions methods used for this project shall conform to the standards
and specifications of the CitV's Public Utilities Handbook.
City of Raleigh Public Utilities Department Permit IY
WATERSHED: NEUSE, WALNUT CREEK
STREAM BUFFER: NONE
PARKING DATA:
SINGLE TENANT BUILDING
SIZE SF
PARKING STANDARD
PARKING REQUIRED
OFFICE - BANK
2,495 SF
1 PER 400 SF
6.23
MULTI -TENANT BUILDING
SIZE SF
PARKING STANDARD
PARKING REQUIRED
CAFE (1ST & 2ND FLOORS)
1, 741 SF
1 PER 150 SF
11.61
HEALTH CLINIC (1ST FLOOR)
8,018 SF
1 PER 300 SF
26.73
THERAPY CLINIC (1ST FLOOR)
3,976 SF
1 PER 300 SF
13.25
ART NON -PROFITS (1ST FLOOR)
OFFICES
801 SF
1 PER 400 SF
2.00
DANCE STUDIO
1, 759 SF
1 PER 300 SF
5.98
ART GALLERY
1, 795 SF
1 PER 300 SF
5.86
OFFICE (2ND FLOOR)
9,008 SF
1 PER 400 SF
22.52
OFFICE (2ND FLOOR)
1,617 SF
1 PER 400 SF
4.04
OFFICE (2ND FLOOR)
Z 180 SF
1 PER 400 SF
5.45
OFFICE (2ND FLOOR)
1,429 SF
1 PER 400 SF
3.57
ART NONPROFIT OFFICES(2ND)
760 SF
1 PER 300 SF
2.53
COMMON AREA
3, 774 SF
1 PER 350 SF
10.78
TOTAL PARKING REQUIRED,
120.59(121 SPACES
TOTAL PARKING PROVIDED:
122 SPACES
TOTAL HANDICAP REQUIRED: 5 SPACES
TOTAL HANDICAP PROVIDED: 7 SPACES
BIKE PARKING SHORT TERM. -
SINGLE TENANT BUILDING
SIZE SF
SPACES STANDARD
SPACES REQUIRED
OFFICE - BANK
Z495 SF
1 PER 10000 SF (4 MIN)
4 (MIN)
MULTI -TENANT BUILDING
SIZE SF
SPACES STANDARD
SPACES REQUIRED
CAFE
1,741 SF
1 PER 25,000 SF
.069
HEALTH CLINIC
8,018 SF
1 PER 10,000 SF
.801
THERAPY CLINIC
3,976 SF
1 PER 10,000 SF
.397
ART NON -PROFITS
DANCE STUDIO
1, 759 SF
1 PER 10,000 SF
.176
ART GALLERY
1,795 SF
1 PER 10,000 SF
.179
OFFICE
15,795 SF
1 PER 10,000 SF
1.58
COMMON AREA:
3,774 SF
N/A
N/A
TOTAL BIKE SHORT TERM PARKING
REQ:
8 SPACES (4 RACKS)
TOTAL BIKE SHORT TERM PARKING PROV.•
10 SPACES (5 RACKS)
BIKE PARKING LONG TERM:
SINGLE TENANT BUILDING
SIZE SF
SPACES STANDARD
SPACES REQUIRED
OFFICE - BANK
2,495 SF
1 PER 5000 SF (4 MIN)
4 (MIN)
MULTI -TENANT BUILDING
SIZE SF
SPACES STANDARD
SPACES REQUIRED
CAFE
1,741 SF
1 PER 25,000 SF
.069
HEALTH CLINIC
8,018 SF
1 PER 10,000 SF
.801
THERAPY CLINIC
3,976 SF
1 PER 10,000 SF
.397
ART NON -PROFITS
DANCE STUDIO
1,759 SF
1 PER 10,000 SF
.176
ART GALLERY
1,795 SF
1 PER 10,000 SF
.179
OFFICE
15,795 SF
1 PER 5,000 SF
1.58
COMMON AREA:
3,774 SF
N/A
N/A
TOTAL BIKE LONG TERM PARKING REQ.
8 SPACES (5 RACKS)
TOTAL BIKE LONG TERM PARKING PROV.•
9 SPACES (5 RACKS)
TREE CONSERVATION: REQUIREMENTS SATISFIED WITH THE SOUTHEAST YMCA MIXED -USE
INFRASTRUCTURE SUBDIVISION PLANS (S-21-17). BM 2017, PG 2463
PERMITTING JURISDICTIONS
ZONING: RALEIGH
WATER/SEWER: RALEIGH
EROSION CONTROL: NCDEQ
BLOCK PERIMETER AND CROSS ACCESS REQUIREMENTS EXEMPTIONS.
1. COMPLIANCE WITH THE BLOCK PERIMETER STANDARDS SHALL NOT BE REQUIRED DUE TO THE FOLLOWING
CONDITION. THE PROJECT SITE IS BELOW THE MINIMUM APPLICABLE SITE AREA ESTABLISHED IN THE TABLE
FOUND IN SEC.8.3.2.A.2.b.
2. THE CREATION OF CROSS ACCESS VEHICULAR DRIVES BETWEEN ABUTTING PROPERTIES ON THREE SIDES OF
THE PROJECT PROPERTY ARE OBSTRUCTED BY EITHER A CONTROLLED ACCESS HIGHWAY, WATER
COURSE & PREVIOUSLY ESTABLISHED TREE CONSERVATION AREA PER SEC.8.3.2.A.1.b
CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION
Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and
authorization for construction is not to be considered to represent total compliance with all legal requirements far
development and construction. The property owner, design consultants, and contractors are each responsible for
compliance with all applicable City, State and Feceral laws. This specific authorization below is not a permit, nor shall it be
construed to permit any violation of City, State or federal Law. All Construction must be in accordance with all Local, State,
and Federal Rules and Regulations.
Electronic Approval: This approval is being issued electronically. This approval is valid only upon the signature of a City of
Raleigh Review Officer below, The City will retain a copy of the approved plans. Any work authorized by this approval must
proceed in accordance with the plans kepton file with the City. This electronic approval may not be ed ited once issued. Any
modificationtothisappDiggaUyssdgned t0ihty-at-Raleigh
Reason: I am approving this document.
Contact Info: Isaac Roldan
Date: 2022.08.31 09:44:40-04'00'
City of Raleigh Development Approval
City of Raleigh Review Officer
These drawings are instruments of
service and as such remain the
property of the architect. No copies
or reproductions of these drawings
are permitted without the consent of
the architect Upon completion of the
work all the drawings (except the
contract copies) are to be returned
to the architect.
Copyright© 2022
�'�frfrnntf
SELF-HELP
BEACON
POINT
RALEIGH, NC
PROJECT NUMBER:
20015
COVER
CLH DESIGN, P.A.
Regency Park
400 Regency Forest Drive
Suite 120
Cary, North Carolina 27518
Phone: 919 319-6716
Fax.. 919 319-7518
LA: C-106, PE: C-1595
SITE PERMIT REVIEW SET
Revisions
Drawn YA, DC, SH
Checked BH, SM
Date AUGUST 08, 2022
Sheet
Of C000
RENDERING
-----I Pp emi Trb-c
. � R�gi�trati�n
TRU 19
oulheast RaIdgh YMCA
o�
Beacon
�P
1 44(
Rafe
LOCATION MAP
0
Q
0
D
Wake C-gunty
Transportation
-11
DESIGN TEAM
ARCHITECTURAL
MECHANICAL
PLUMBING
ELECTRICAL
FIRE PROTECTION
STRUCTURAL
CIVIL/ LANDSCAPING
SELF - HELP
N T
RALEIGH, NORTH CAROLINA
ISSUED FOR PERMIT
AUGUST 24, 2022
DTW ARCHITECTS & PLANNERS, LTD.
EDMONDSON ENGINEERS, P.A.
EDMONDSON ENGINEERS, P.A.
EDMONDSON ENGINEERS, P.A.
EDMONDSON ENGINEERS, P.A.
RO S S LINDEN ENGINEERS PC
CLH DESIGN, P.A.
DRAWING INDEX
TO
COVER SHEET/ DRAWING INDEX
Al
FIRST FLOOR PLAN
FP1.0
T1
DATA SHEET
A2
SECOND FLOOR PLAN
T2
EGRESS PLAN - FIRST FLOOR
A3
FIRST FLOOR REFLECTED CEILING PLAN
P1.0
T3
EGRESS PLAN - SECOND FLOOR
A4
SECOND FLOOR REFLECTED CEILING PLAN
P1.1
T4
ACCESSIBILITY SHEET
A5
ROOF PLAN & ROOF DETAILS
P1.2
P1.3
A6
ELEVATIONS
P2.1
C000
SITE COVER SHEET
A7
BUILDING SECTIONS
C001
ADMINISTRATIVE APPROVAL ACTION
A8
BUILDING SECTIONS
P3.1
C100
OVERALL SITE PLAN
A9
WALL SECTIONS
P3.2
C101
SITE STAKING PLAN
A10
WALL SECTIONS
P3.3
C102
UDO COMPLIANCE PLAN
P4.1
All
WALL SECTION DETAILS
P4.2
C200
OVERALL EXISTING CONDITIONS & DEMO PLAN
Al2
DETAILS
C201
EXISTING CONDITIONS & DEMO PLAN
A13
ENLARGED PLANS
P4.3
C300
OVERALL GRADING PLAN
A14
ENLARGED PLANS
C301
SITE GRADING PLAN
A15
PLAN DETAILS
MO.1
C302
DRAINAGE AREAS PRE -DEVELOPMENT
A16
PLAN DETAILS & INTERIOR ELEVATIONS
MO.2
C303
DRAINAGE AREAS POST -DEVELOPMENT
M1.1
C400
OVERALL EROSION CONTROL PLAN
A17
FINISH & DOOR SCHEDULE/ DOOR & FRAME TYPES/
M1'2
M1.3
C401
EROSION CONTROL PLAN- INITIAL INSTALL
FRAME DETAILS
C402
EROSION CONTROL PLAN- FINAL INSTALL
A18
ALUMINUM WINDOW TYPES
M2.1
C403
NPDES STABILIZATION PLAN
C500
OVERALL SITE UTILITY PLAN
M2.2
M2.3
C501
SITE UTILITY PLAN
S1.1
SLAB & FOUNDATION PLAN
M3.1
S1.2
SECOND FLOOR FRAMING PLAN
C600
OVERALL LANDSCAPE PLAN
S1.3
ROOF FRAMING PLAN
C601
LANDSCAPE PLAN
S2.1
STRUCTURAL NOTES & DETAILS
E1.0
C01
SITE EROSION DETAILS
E1.1
C702
SITE EROSION DETAILS
S2.2
SECTIONS &DETAILS
E1.2
C703
SITE EROSION DETAILS
S2.3
SECTIONS &DETAILS
E1.3
C704
C705
SCM DETAILS
LANDSCAPE DETAILS
S2.4
SECTIONS & DETAILS
E1.4
C706
LANDSCAPE DETAILS
S2.5
SECTIONS & DETAILS
E1.5
E1.6
C801
SITE UTILITY/ STORM DETAILS
E1.7
C802
SITE UTILITY/ STORM DETAILS
E2.0
C803
SITE UTILITY/ STORM DETAILS
E2.1
C901
SITE DETAILS
E3.0
C902
SITE DETAILS
C903
SITE DETAILS
ES1.1
FA1.1
FA1.2
FIRE PROTECTION PLANS & NOTES
PLUMBING NOTES, SCHEDULES & LEGENDS
PLUMBING PLAN - FIRST FLOOR
PLUMBING PLAN - SECOND FLOOR
PLUMBING ROOF PLAN
PLUMBING PLAN - SECOND FLOOR ENLARGED PLANS
PLUMBING ROOF DRAIN RISERS
PLUMBING WATER RISER DIAGRAM
PLUMBING WASTE & VENT RISER DIAGRAM
PLUMBING DETAILS
PLUMBING DETAILS
PLUMBING DETAILS
HVAC LEGENDS & NOTES
HVAC SCHEDULES
MECHANICAL FLOOR PLAN - FIRST FLOOR
MECHANICAL FLOOR PLAN - SECOND FLOOR
MECHANICAL ROOF PLAN
HVAC DETAILS
HVAC DETAILS
HVAC SEQUENCE OF OPERATIONS & DETAILS
PENETRATION DETAILS
ELECTRICAL SYMBOLS, RISERS, ABBREVIATIONS & NOTES
POWER PLAN - FIRST FLOOR
LIGHTING PLAN - FIRST FLOOR
POWER PLAN - SECOND FLOOR
LIGHTING PLAN - SECOND FLOOR
ENLARGED POWER PLANS
ENLARGED LIGHTING PLANS
POWER PLAN - ROOF
ELECTRICAL DETAILS
ELECTRICAL & FIRE PENETRATION DETAILS
ELECTRICAL PANEL SCHEDULES
ELECTRICAL SITE PLAN
FIRE ALARM PLAN - FIRST FLOOR
FIRE ALARM PLAN - SECOND FLOOR
REVIEWERS APPROVAL STAMP:.
PROJECT DESCRIPTION
THIS PROJECT IS A 2-STORY BUILDING, SHELL AND PUBLIC AREAS
ONLY. TENANT SPACES WILL BE UPFITTED UNDER SEPARATE PERMITS.
THE BUILDING EXTERIOR WILL FEATURE A COMBINATION OF BRICK,
METAL WALL PANELS AND STOREFRONT ALUMINUM WINDOWS.
THE INTERIOR WORK WILL INCLUDE FIRST & SECOND FLOOR LOBBIES
WITH RESTROOMS, ELEVATOR, AND CENTRAL STAIRS. THERE ARE ALSO
STAIRWELLS ON EACH END OF THE BUILDING. IN ADDITION, THERE IS
A 2-STORY CAFE SPACE WITH AN OPEN STAIRWAY AND AN
ADDITIONAL EMERGENCY STAIR EGRESS.
These drawings are instruments of
service and as such remain the
property of the architect. No copies
or reproductions of these drawings
are permitted without the consent of
the architect. Upon completion of the
work all the drawings (except the
contract copies) are to be returned
to the architect.
Copyright(C) 2022
SELF-HELP
BEACON
POINT
2-STORY BLDG
SHELL & CORE
RALEIGH, NC
PROJECT NUMBER:
20015