Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW4220901_Stormwater Narrative_20220921
STORMWATER NARRATIVE AND DESIGN CALCULATIONS For: Davidson Charter Academy Davidson County, North Carolina ADI Project No. 22-017 'ESS% �.�pF oy;ti :a r=- 0 Zp2ti FNG I Developer: DCA Lexington Properties 500 Biesecker Road Lexington, NC 27295 Prepared bv: Allied Design, Inc. 4720 Kester Mill Road Winston-Salem, NC 27103 (336) 765-2377 scausey@.allied-engsurv.com STORMWATER NARRATIVE DAVIDSON CHARTER ACADEMY TABLE OF CONTENTS A. Introduction B. Methodology C. Site Design and Assessment D. Conclusion Appendix A. NOAA Rainfall Data (Hydraflow Rainfall Report) B. Curve Number Summary C. Wet Pond Calculations D. 1-Year/24 Hour Frequency Design Storm Hydrographs E. 100-Year Frequency Design Storm Hydrographs F. Pond Report G. Outlet Stabilization Calculations H. Ditch Calculations I. USDA Soils Report J. National Wetlands Inventory Wetlands Delineation K. ECS Geotechnical Engineering Report Allied Design Inc. Project No.: 22-017 Page 1 STORMWATER NARRATIVE DAVIDSON CHARTER ACADEMY A. Introduction The Davidson Charter Academy consists of a 30-acre parcel of property located along Biesecker Road in Lexington, North Carolina. Phase 2 takes place on the western portion of the site and proposes a new building addition, parking lots, paved roads, and a soccer field. In accordance with the requirements of NCDEQ Post Construction Stormwater program, the project will require a stormwater management permit. However, the proposed permit will cover the entirety of the Davidson Charter Academy project, including Phase 1, Phase 2, and up to an acre of future impervious area. Stormwater management permit approval will require design and construction of permanent water quality measure to manage the runoff from all new impervious coverage. The stormwater management plan for Davidson Charter Academy utilizes a wet detention basin as the primary Stormwater Control Measures (SCM) to meet NCDEQ's post construction stormwater management requirements. The wet detention basin will be designed to treat the first 1-inch of runoff for quality treatment. B. Methodology Reference for preparation of the stormwater management plan is made to the North Carolina Division of Environmental Quality's "New Stormwater Design Manual" (MDC's). City/County topographical maps, site surveys, and the proposed site development plans were utilized to delineate the post -development runoff patterns. The USDA Soils Survey was referenced and used to determine the Runoff Curve Numbers (CN's). The storm events modeled in this design are based on the SCS 24 Hour Storm Distribution for the 1-year storm and the 6 Hour Storm Distribution for 100-year design storm. The Intensity -Duration Frequency Curves were established using the FHA Method. Precipitation frequency estimates were obtained from NOAA. Allied Design Inc. Project No.: 22-017 Page 2 STORMWATER NARRATIVE DAVIDSON CHARTER ACADEMY Inflow hydrographs were derived from the SCS Unit Hydrograph Method and routed through the proposed wet detention basin. The Storage Indication Method is used to determine and verify design of the primary outlet structure. "Hydraflow Hydrographs", 2004 edition software was used to perform the routing calculations. The wet detention basin design is based on capture of the first 1-inch of runoff. The required surface area and volume is calculated based on the SA/DA method. Design of forebays is included and are sized to provide 15-20% of the volume of the wet detention basin. The wet detention basin will utilize a precast concrete outlet structure to control the post -developed runoff rates from the 1-year, 24-Hour storm event to a runoff rate that minimizes hydrologic impacts to the receiving stream. The outlet structure is modeled to assume 50% blockage of the overflow weir. The proposed detention is designed to ensure the maximum storage elevation during the 100-year storm remains at least 1 foot below the top of dam elevation. C. Conclusion This Stormwater Narrative concludes that the project is being developed in accordance with the Wet Pond provisions of the MDC. As indicated by the stormwater management plans and calculations included in this report, stormwater quality and is being provided on -site in accordance with NCDEQ's stormwater management requirements. 1. Stormwater Quality Management The drainage area routed to the wet detention basin includes 26.16 acres with approximately 7.46 acres being impervious. It should be noted that approximately 0.037 acres of the site are offsite and will be managed by the SCM. The wet detention basin captures the first 1-inch of runoff from the post -developed drainage areas and treats the flow in accordance with the requirements of the Allied Design Inc. Project No.: 22-017 Page 3 STORMWATER NARRATIVE DAVIDSON CHARTER ACADEMY NCDEQ's Stormwater Design Manual. The routing hydrographs included in this report also verify that the post -developed runoff for the 1-yr 24-hr water quality event to a runoff rate that minimizes hydrologic impacts to the receiving stream. A summary of the water quality management is provided as follows: Summary of Water Quality Management Management Aspects Pond 1 Required Provided Water Quality Volume (cf) 27,824 29,385 Water Quality Elevation (ft) 757.7 757.8 Water Quality Surface Area (sf) 9,230 13,883 Allied Design Inc. Project No.: 22-017 Page 4 STORMWATER NARRATIVE DAVIDSON CHARTER ACADEMY Appendix Allied Design Inc. Project No.: 22-017 Page 5 A. Hydraflow Rainfall Report Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2021 Return Period Intensity -Duration -Frequency Equation Coefficients (FHA) (Yrs) B D E (N/A) 1 62.9479 13.1000 0.9022 -------- 2 72.0400 13.2000 0.8883 -------- 3 0.0000 0.0000 0.0000 -------- 5 0.0000 0.0000 0.0000 -------- 10 69.9702 12.5000 0.8066 -------- 25 58.6655 11.0000 0.7384 -------- 50 0.0000 0.0000 0.0000 -------- 100 46.2960 9.0000 0.6519 -------- File name: dca intensity.IDF Intensity = B / (Tc + D)^E Thursday, 08 / 11 / 2022 Return Period Intensity Values (in/hr) (Yrs) 5 min 10 15 20 25 30 35 40 45 50 55 60 1 4.62 3.70 3.10 2.68 2.36 2.11 1.91 1.75 1.61 1.50 1.40 1.31 2 5.47 4.41 3.71 3.21 2.83 2.54 2.30 2.11 1.95 1.81 1.69 1.59 3 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10 6.95 5.68 4.83 4.22 3.76 3.40 3.11 2.87 2.66 2.49 2.34 2.21 25 7.57 6.20 5.29 4.65 4.16 3.78 3.47 3.22 3.00 2.82 2.66 2.52 50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 100 8.29 6.79 5.83 5.16 4.65 4.25 3.93 3.66 3.44 3.24 3.08 2.93 Tc = time in minutes. Values may exceed 60. name: W:\PROJECTS\22-017 Davidson Charter Academv\DESIGN\Stormwater\Hvdraflow Files\dca DreciD deDth.DCD Storm Rainfall Precipitation Table (in) Distribution 1-yr 2-yr 3-yr 5-yr 10-yr 25-yr 50-yr 100-yr SCS 24-hour 2.80 3.38 0.00 0.00 4.87 5.74 0.00 7.14 SCS 6-Hr 1.97 2.37 0.00 0.00 3.38 3.95 0.00 4.82 Huff -1st 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Huff-2nd 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Huff-3rd 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Huff-4th 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Huff-Indy 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Custom 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CURVE NUMBER CALCULATIONS POST DEVELOPMENT POI 1 TYPE OF AREA SOIL GROUP CN CN SF POI TOTAL AREA SF %POI %CN WEIGHTED CN ONSITE OPEN SPACE (FAIR) B 68 606,273 1,139,349.00 53.21% 36.2 77 OFFSITE OPEN SPACE (FAIR) B 69 208,378 18.29% 12.6 ONSITE GRAVEL A 79 1,190 0.10% 0.1 ONSITE GRAVEL B 85 10,811 0.95% 0.8 OFFSITE GRAVEL B 85 1,617 0.14% 0.1 ONSITE IMPERVIOUS A,B,C 98 1267,5201 23.48%1 23.0 FUTURE IMPERVIOUS A,B,C 98 43,560 3.82% 1 3.7 IMPERVIOUS AREA 28% ACRES 1 26.16 C. Wet Pond Design Calculation Sheet SA/DA Method DAVIDSON CHARTER ACADEMY POND 1 August 12, 2022 Determine 1 inch Water Quality Volume (WQV) Impervious area (IA) = 28% Runoff Coefficient (Rv)= 0.302 Design Storm Depth (RD) = 1 in Drainage Area (A) = 26.16 ac Design Volume (Dv) = 28,678 cf Determine Required Main Pool Surface Area Percent Impervious Cover = 28% Permanent Pool Average Depth = 5 ft SA/DA = 0.81 Drainage Area = 26.16 ac Required Surface Area = 0.21 ac Required Surface Area = 9,230 sf Confirm Pond Volume Provided (Main Pool Only) Main Pool Elev. = 756.00 Vegetated Shelf Lower Elev. = 756.25 Vegetated Shelf Upper Elev. = 755.75 ELEV. CONTOUR AREA INCREMENTAL VOLUME ACCUMULATED VOLUME (ft) (sq ft) (cf) (cf) 756.00 13,883 0 0 756.25 15,342 3,653 3,653 757.00 16,473 11,931 15,584 758.00 18,029 17,251 32,835 759.00 19,643 18,836 51,671 760.00 21,314 20,479 72,149 761.00 1 25,375 j 23,345 95,494 762.00 1 27,441 1 26,408 121,902 Determine WQV Elevation Required ELEVATION ACCUMULATED VOLUME (ft) (sq ft) 757.00 15,584 WQV ELEV 28,678 758.00 32,835 MIN. WQV ELEV. 757.76 Provided WQV Elevation 757.8 Provided WQV Volume (cf) 29,385 D. Hydrograph Report Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2021 Thursday, 08 / 11 / 2022 Hyd. No. 4 post dev Hydrograph type = SCS Runoff Peak discharge = 38.45 cfs Storm frequency = 1 yrs Time to peak = 12.00 hrs Time interval = 2 min Hyd. volume = 88,773 cuft Drainage area = 26.160 ac Curve number = 77 Basin Slope = 0.0 % Hydraulic length = 0 ft Tc method = User Time of conc. (Tc) = 8.00 min Total precip. = 2.80 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (Cfs) 40.00 30.00 20.00 10.00 0.00 ' ' 1 0 2 4 — Hyd No. 4 post dev Hyd. No. 4 -- 1 Year 6 8 10 12 14 16 18 20 22 24 Q (Cfs) 40.00 30.00 20.00 10.00 '- 0.00 26 Time (hrs) Hydrograph Report Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2021 Thursday, 08 / 11 / 2022 Hyd. No. 6 pond 1 Hydrograph type = Reservoir Peak discharge = 9.466 cfs Storm frequency = 1 yrs Time to peak = 12.17 hrs Time interval = 2 min Hyd. volume = 88,371 cuft Inflow hyd. No. = 4 - post dev Max. Elevation = 758.06 ft Reservoir name = pond 1 Max. Storage = 33,929 cuft Storage Indication method used Q (cfs) 40.00 30.00 20.00 10.00 0.00 1 ' — 0 4 — Hyd No. 6 pond 1 Hyd. No. 6 -- 1 Year 8 12 16 20 Hyd No. 4 24 28 32 36 40 44 Total storage used = 33,929 cuft Q (cfs) 40.00 30.00 20.00 10.00 —' 0.00 48 Time (hrs) E. Hydrograph Report Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2021 Thursday, 08 / 11 / 2022 Hyd. No. 3 post dev Hydrograph type = SCS Runoff Peak discharge = 56.81 cfs Storm frequency = 100 yrs Time to peak = 2.43 hrs Time interval = 2 min Hyd. volume = 234,848 cuft Drainage area = 26.160 ac Curve number = 77 Basin Slope = 0.0 % Hydraulic length = 0 ft Tc method = User Time of conc. (Tc) = 8.00 min Total precip. = 4.82 in Distribution = SCS 6-Hr Storm duration = 6.00 hrs Shape factor = 484 Q (Cfs) 60.00 50.00 40.00 30.00 20.00 10.00 0.00 0.0 1.0 — Hyd No. 3 post dev Hyd. No. 3 -- 100 Year 2.0 3.0 4.0 5.0 6.0 Q (Cfs) 60.00 50.00 40.00 30.00 20.00 10.00 1 0.00 7.0 Time (hrs) Hydrograph Report Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2021 Friday, 08 / 12 / 2022 Hyd. No. 5 pond 1 Hydrograph type = Reservoir Peak discharge = 32.34 cfs Storm frequency = 100 yrs Time to peak = 2.63 hrs Time interval - 2 min Hyd. volume = 234,551 cuft Inflow hyd. No. - 3 - post dev Max. Elevation = 759.41 ft Reservoir name = pond 1 Max. Storage = 59,971 cuft Storage Indication method used. Q (cfs) 60.00 50.00 40.00 30.00 20.00 10.00 am NEW111XV pond 1 Hyd. No. 5 -- 100 Year 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 Hyd No. 5 — Hyd No. 3 Total storage used = 59,971 cuft Q (cfs) 60.00 50.00 40.00 30.00 20.00 10.00 --' 0.00 18.0 Time (hrs) F. Pond Report 4 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2021 Tuesday, 08 / 23 / 2022 Pond No. 1 - pond 1 Pond Data Contours -User-defined contour areas. Conic method used for volume calculation. Begining Elevation = 756.00 ft Stage / Storage Table Stage (ft) Elevation (ft) Contour area (sgft) Incr. Storage (cult) Total storage (cult) 0.00 756.00 13,883 0 0 0.25 756.25 15,342 3,651 3,651 1.00 757.00 16,473 11,927 15,578 2.00 758.00 18,029 17,243 32,822 3.00 759.00 19,643 18,828 51,650 4.00 760.00 21,314 20,471 72,121 6.00 762.00 27,441 48,621 120,742 Culvert / Orifice Structures Weir Structures [A] [B] [C] [PrfRsr] [A] [B] [C] [D] Rise (in) = 24.00 4.00 0.00 0.00 Crest Len (ft) = 20.00 Inactive 0.00 0.00 Span (in) = 24.00 4.00 0.00 0.00 Crest El. (ft) = 757.80 0.00 0.00 0.00 No. Barrels = 1 1 0 0 Weir Coeff. = 3.33 3.33 3.33 3.33 Invert El. (ft) = 753.80 756.00 0.00 0.00 Weir Type = 1 Broad --- --- Length (ft) = 64.00 0.50 0.00 0.00 Multi -Stage = Yes No No No Slope (%) = 1.25 0.01 0.00 n/a N-Value = .013 .013 .013 n/a Orifice Coeff. = 0.60 0.60 0.60 0.60 Exfil.(in/hr) = 0.000 (by Wet area) Multi -Stage = n/a Yes No No TW Elev. (ft) = 0.00 Stage (ft) 6.00 6'x11IH 4.00 3.00 PAIIH m Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s) 4.00 8.00 12.00 Total Q Stage / Discharge Elev (ft) 762.00 760.00 759.00 757.00 ' ' ' ' ' ' ' ' 756.00 16.00 20.00 24.00 28.00 32.00 36.00 40.00 44.00 Discharge (cfs) G. Allied Design, Inc. CIVIL ENGINEERING ❖ LAND SURVEYING 4720 Kester Mill Road Winston-Salem, North Carolina 27103 Ph. 336.765.2377 •a Fax 336.760.8886 Outlet Stabilization In .__TT PROJECT NAME Davidson Charter School Outlet Stabilization PROJECT NO. 22-017 BY WAB CHECKED BY SMC SHEET OF DATE 3-May-22 REV 3-May-22 Z s b lu 2u bu 100 200 500 1000 Discharge (0/sec) Curves may not be extrapolated. Figure 8.06a Design of outlet protection protection from a round pipe flowing full, minimum tailwater condition (Tw < 0.5 diameter). Outlet Pipe Diameter Discharge d50 La W dmax apron thickness NCDOT riprap (in) (cfs) (ft) (ft) (ft) (ft) (ft) Class 100 15 2.68 0.20 8.0 9.3 0.3 0.5 A 200 1 15 8.64 0.35 10.0 11.3 1 0.5 0.8 B 300 36 20.89 0.60 20.0 23.0 0.9 1.4 B 400 24 15.76 0.40 13.0 15.0 0.6 0.9 B 500 15 3.77 0.20 8.0 9.3 0.3 0.5 A 600 24 1 9.47 1 0.50 1 10.0 1 12.0 0.8 1 1.1 1 B TAKEN FROM THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL H. DITCH SCHEDULE (25 YEAR STORM DESIGN) DAVIDSON CHARTER SCHOOL DAVIDSON COUNTY, NORTH CAROLINA August 12, 2022 z U =~ 0 w Q w < 0 (AC) w O z Z w _U- w J w w O ?U Z O Q O w w O U (IN/HR) W z z - w CD 0-1 = U o (CFS) a O j U ~ 0 (FT/FT) = 0 O O 0o (FT) w a � W w W ("X" : 1) O i w Oa w 0 (FT) U O W > (FPS) J g w Q O ZU Z J Z � w Q aW -1z a W 1 0.60 0.50 5 7.60 2.28 9.00% 0 3 0.40 4.79 S75 D 2 0.60 0.50 5 7.60 2.28 4.50% 3 3 0.23 2.63 S75 D 3 0.38 0.50 5 7.60 1.44 6.00% 3 3 0.39 3.22 S75 D 4 0.50 0.50 5 7.60 1.90 1.25% 0 3 0.67 1.41 S75 D 5 0.23 0.50 5 7.60 0.87 1.25% 0 3 0.52 1.08 S75 D 6 2.07 0.50 5 7.60 7.87 3.70% 10 3 0.26 2.80 S75 D 7 13.18 0.50 5 7.60 50.08 5.00% 15 3 0.40 5.88 S75 D 8 9.11 0.50 5 7.60 34.62 3.00% 10 3 0.58 5.05 S75 D 9 2.38 0.50 5 7.60 9.04 6.25% 6 3 0.28 4.65 S75 D 10 2.31 0.50 5 7.60 8.78 11.40% 5 3 0.23 6.68 RIP RAP D 11 13.16 0.50 5 7.60 50.01 3.00% 5 3 0.76 9.05 RIP RAP D NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #1 Name Ditch #1 Discharge 2.28 Channel Slope 0.09 Channel Bottom Width 0 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 > Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 2.28 cfs 4.79 ft/s 0.4 ft 0.031 4 Ibs/ft2 2.23 Ibs/ft2 1.79 STABLE Vegetation Underlying Straight 2.28 cfs 4.79 ft/s 0.4 ft 0.031 1.46 Ibs/ft2 1.06 Ibs/ft2 1.38 STABLE Substrate NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #2 Name Ditch #2 Discharge 2.28 Channel Slope 0.045 Channel Bottom Width 3 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 > Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Jnreinforced Straight 2.28 cfs 2.63 ft/s 0.23 ft 0.04 4 Ibs/ft2 0.66 Ibs/ft2 6.1 STABLE Vegetation Underlying Straight 2.28 cfs 2.63 ft/s 0.23 ft 0.04 2.5 Ibs/ft2 0.54 Ibs/ft2 4.61 STABLE Substrate NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #3 Name Ditch #3 Discharge 1.44 Channel Slope 0.06 Channel Bottom Width 0 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 > Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight Vegetation Underlying Straight Substrate 1.44 cfs 3.22 ft/s 0.39 ft 0.036 1.44 cfs 3.22 ft/s 0.39 ft 0.036 4lbs/ft2 1.44lbs/ft2 2.77 STABLE 2.07lbs/ft2 0.69lbs/ft2 3.03 STABLE NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #4 Name Ditch #4 Discharge 1.9 Channel Slope 0.0125 Channel Bottom Width 0 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 > Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Jnreinforced Straight 1.9 cfs 1.41 ft/s 0.67 ft 0.055 4 Ibs/ft2 0.52 Ibs/ft2 7.66 STABLE Vegetation Underlying Straight 1.9 cfs 1.41 ft/s 0.67 ft 0.055 4 Ibs/ft2 0.25 Ibs/ft2 16.15 STABLE Substrate NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #5 Name Ditch #5 Discharge 0.87 Channel Slope 0.0125 Channel Bottom Width 0 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 > Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Jnreinforced Straight 0.87 cfs 1.08 ft/s 0.52 ft 0.061 4 Ibs/ft2 0.4 Ibs/ft2 9.89 STABLE Vegetation Underlying Straight 0.87 cfs 1.08 ft/s 0.52 ft 0.061 4 Ibs/ft2 0.19 Ibs/ft2 20.85 STABLE Substrate NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #6 Name Ditch #6 Discharge 7.87 Channel Slope 0.037 Channel Bottom Width 10 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 > Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 7.87 cfs 2.8 ft/s 0.26 ft 0.04 4 Ibs/ft2 0.6 Ibs/ft2 6.65 STABLE Vegetation Underlying Straight 7.87 cfs 2.8 ft/s 0.26 ft 0.04 2.45 Ibs/ft2 0.56 Ibs/ft2 4.39 STABLE Substrate NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #7 Name Ditch #7 Discharge 50.08 Channel Slope 0.05 Channel Bottom Width 20 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 > Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight 50.08 cfs 5.88 ft/s 0.4 ft 0.029 4 Ibs/ft2 1.24 Ibs/ft2 3.22 STABLE Vegetation Underlying Straight 50.08 cfs 5.88 ft/s 0.4 ft 0.029 1.35 Ibs/ft2 1.17 Ibs/ft2 1.15 STABLE Substrate NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #8 Name Ditch #8 Discharge 34.61 Channel Slope 0.03 Channel Bottom Width 10 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 > Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight Vegetation Underlying Straight Substrate 34.61 cfs 5.05 ft/s 0.58 ft 0.032 34.61 cfs 5.05 ft/s 0.58 ft 0.032 4lbs/ft2 1.09lbs/ft2 3.67 STABLE 1.61lbs/ft2 0.94lbs/ft2 1.72 STABLE NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #9 Name Ditch #9 Discharge 9.04 Channel Slope 0.0625 Channel Bottom Width 6 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Unreinforced Vegetation North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 > Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Mannings N Remarks Depth Shear Stress Shear Stress Factor Pattern Unreinforced Straight Vegetation Underlying Straight Substrate 9.04 cfs 4.65 ft/s 0.28 ft 0.032 9.04 cfs 4.65 ft/s 0.28 ft 0.032 4lbs/ft2 1.11lbs/ft2 3.62 STABLE 1.57lbs/ft2 0.97lbs/ft2 1.61 STABLE NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #10 Name Ditch #10 Discharge 8.78 Channel Slope 0.114 Channel Bottom Width 5 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Rock Riprap North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Phase Reach Discharge Velocity Normal Mannings N Permissible Calculated Safety Remarks Staple Depth Shear Stress Shear Stress Factor Patters Rock Riprap Straight 8.78 cfs 6.68 ft/s 0.23 ft 0.026 2 Ibs/ft2 1.45 Ibs/ft2 1.38 STABLE -- Unvegetated NORTH AMERICAN GREEN CHANNEL ANALYSIS > > > Ditch #11 Name Ditch #11 Discharge 50.01 Channel Slope 0.054 Channel Bottom Width 5 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class D 2-6 in Vegetation Type Mix (Sod and Bunch) Vegetation Density Fair 50-64% Soil Type Clay Loam (CL) Rock Riprap North American Green 5401 St. Wendel -Cynthiana Rd. Poseyville, Indiana 47633 Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 Phase Reach Discharge Velocity Normal Mannings N Permissible Calculated Safety Remarks Staple Depth Shear Stress Shear Stress Factor Patters Rock Riprap Straight 50.01 cfs 9.05 ft/s 0.76 ft 0.026 2 Ibs/ft2 1.9 Ibs/ft2 1.05 STABLE -- Unvegetated IN kc . » . -� < 7. « • `� � : � 2 \_\� , _ � 4� ^� • '� © �- .x �Pfc Hydrologic Soil Group —Davidson County, North Carolina MAP LEGEND Area of Interest (AOI) 0 Area of Interest (AOI) Soils Soil Rating Polygons 0 A 0 A/D 0 B 0 B/D C 0 C/D 0 D 0 Not rated or not available Soil Rating Lines r 0 A r 0 A/D B B/D N 0 C r 0 C/D r 0 D r 0 Not rated or not available Soil Rating Points 0 A 0 A/D 0 B 0 B/D ❑ C 0 C/D 0 D ❑ Not rated or not available Water Features Streams and Canals Transportation — Rails 0 Interstate Highways US Routes Major Roads Local Roads Background D6 Aerial Photography MAP INFORMATION The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Davidson County, North Carolina Survey Area Data: Version 23, Jan 21, 2022 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Oct 17, 2020—Nov 3, 2020 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. usoA Natural Resources Web Soil Survey 7/25/2022 Conservation Service National Cooperative Soil Survey Page 2 of 4 Hydrologic Soil Group —Davidson County, North Carolina Hydrologic Soil Group Map unit symbol Map unit name Rating Acres in AOI Percent of AOI CcB Cecil sandy loam, 2 to 8 percent slopes B 40.9 58.0% CcD Cecil sandy loam, 8 to 15 percent slopes A 2.7 3.9% CeD2 Cecil clay loam, 8 to 15 percent slopes, moderately eroded B 25.0 35.5% PnE Poindexter-Wynott complex, 15 to 25 percent slopes C 1.0 1.4% W Water 0.8 1.2% Totals for Area of Interest 70.5 100.0% USDA Natural Resources Web Soil Survey 7/25/2022 Conservation Service National Cooperative Soil Survey Page 3 of 4 Hydrologic Soil Group —Davidson County, North Carolina Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long -duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink -swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff.- None Specified Tie -break Rule: Higher USDA Natural Resources Web Soil Survey 7/25/2022 Conservation Service National Cooperative Soil Survey Page 4 of 4 J. U.S. Fish and Wildlife Service National Wetlands Inventor August 31, 2022 Wetlands U Estuarine and Marine Deepwater . Estuarine and Marine Wetland ❑ Wetlands Delineation for Davidson Charter This map is for general reference only. The US Fish and Wildlife Service is not responsible for the accuracy or currentness of the base data shown on this map. All wetlands related data should Freshwater Emergent Wetland Lake be used in accordance with the layer metadata found on the Wetlands Mapper web site. Freshwater Forested/Shrub Wetland ❑ Other Freshwater Pond ❑ Riverine National Wetlands Inventory (NW) This page was produced by the NW mapper K.