Pre-Construction Notification PCl� Form
A. A licant Information
1. Processing
1 a. Type(s) of approval sought from the
Corps: � Section 404 Permit ❑ Section 10 Permit
1b. Specify Nationwide Permit (NWP) number: 14 or General Permit (GP) number:
1 c. Has the NWP or GP number been verified by the Corps? ❑ Yes � No
1 d. Type(s) of approval sought from the DWQ (check all that apply):
� 401 Water Quality Certification — Regular ❑ Non-404 Jurisdictional General Permit
❑ 401 Water Quality Certification — Express ❑ Riparian Buffer Authorization
1 e. Is this notification solely for the record For the record only for DWQ 401 For the record only for Corps Permit:
because written approval is not required? Certification:
No. ❑ Yes � No ❑ Yes � No
1f. Is payment into a mitigation bank or in-lieu fee program proposed for mitigation � Yes ❑ No
of impacts? If so, attach the acceptance letter from mitigation bank or in-lieu
fee program.
1g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1h ❑ Yes � No
below.
1 h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? ❑ Yes � No
2. Project Information
2a. Name of project: 17BP.8.R.60 Bridge 440 Over Prong Creek Along SR 2261 Old Liberty Road
2b. County: Randolph
2c. Nearest municipality / town: Grays Chapel
2d. Subdivision name: NA
2e. NCDOT only, T.I.P. or state 17BP.8.R.6
project no:
3. Owner Information
3a. Name(s) on Recorded Deed: North Carolina Department of Transportation
3b. Deed Book and Page No.
3c. Responsible Party (for LLC if Robert W Stone II, PE
applicable):
902 Sandhills Blvd.
3d. Street address: p0 Box 1067
3e. City, state, zip: Aberdeen, NC 28315
3f. Telephone no.: 910-944-2344
3g. Fax no.: 910-944-5623
3h. Email address: robstone@ncdot.gov
Page 1 of 10
PCN Form — Version 1.3 December 10, 2008 Version
4. Applicant Information (if different from owner)
4a. Applicant is: � Agent ❑ Other, specify:
4b. Name: Art C. King
4c. Business name NCDOT Highway Division 8
(if applicable):
4d. Street address: 902 North Sandhills Bivd.
4e. City, state, zip: Aberdeen, NC 28315
4f. Telephone no.: 910-944-2344
4g. Fax no.: 910-944-5623
4h. Email address: acking@ncdot.gov
5. Agent/Consultant Information (if applicable)
5a. Name:
5b. Business name
(if applicable):
5c. Street address:
5d. City, state, zip:
5e. Telephone no.:
5f. Fax no.:
5g. Email address:
Page 2 of 10
PCN Form — Version 1.3 December 10. 2008 Version
B. Project Information and Prior Project History
1. Property Identification
1a. Property identification no. (tax PIN or parcel ID): NA
1b. Site coordinates (in decimal degrees): Latitude: 35.832412° Longitude: -79.683239°
(DD.DDDDDD) (-DD.DDDDDD)
1c. Property size: NA
2. Surtace Waters
2a. Name of nearest body of water (stream, river, etc.) to prong Creek 17-16-(1)
proposed project:
2b. Water Quality Classification of nearest receiving water: WS-III
2c. River basin: Cape Fear
3. Project Description
3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this
application:
The site consists of a structurally deficient bridge along a two lane section of state road. Land use in the vicinity of the
project is primarily residential and agricultural.
3b. List the total estimated acreage of all existing wetlands on the property:
No wetlands on site.
3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property:
Prong Creek bisects the project alignment.
3d. Explain the purpose of the proposed project:
The purpose of the project is to replace Bridge 440 which is considered structurally deficient with a box culvert.
3e. Describe the overall project in detail, including the type of equipment to be used:
The existing bridge will be replaced with (3) 10' X 8' RCBC's along the same alignment. Traffic will be detoured off-site
during construction. Standard road building equipment such as trucks, dozers, and cranes will be used.
4. Jurisdictional Determinations
4a. Have jurisdictional wetland or stream determinations by the
Corps or State been requested or obtained for this property /
project (including all prior phases) in the past? ❑ Yes � No ❑ Unknown
Comments: Field visit by NCDOT and USACE determined
that no wetlands are present on-site.
4b. If the Corps made the jurisdictional determination, what type
of determination was made? ❑ Preliminary 0 Final
4c. If yes, who delineated the jurisdictional areas? Agency/Consultant Company:
Name (if known): Other:
4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation.
5. Project History
5a. Have permits or certifications been requested or obtained for � Yes � No ❑ Unknown
this project (including all prior phases) in the past?
5b. If yes, explain in detail according to "help f le" instructions.
6. Future Project Plans
6a. Is this a phased project? ❑ Yes � No
6b. If yes, explain.
Page 3 of 10
PCN Form — Version 1.3 December 10, 2008 Version
C. Proposed Impacts Inventory
1. Impacts Summary
1a. Which sections were completed below for your project (check all that apply):
❑ Wetlands � Streams - tributaries ❑ Buffers
❑ Open Waters ❑ Pond Construction
2. Wetland Impacts
If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted.
2a. 2b. 2c. 2d. 2e. 2f.
Wetland impact Type ofjurisdiction
number — Type of impact Type of wetland Forested (Corps - 404, 10 Area of impact
Permanent (P) or (if known) DWQ — non-404, other) (acres)
Tem ora T
W1 ❑ P❑ T ❑ Yes ❑ Corps
❑ No ❑ DWQ
WZ � P � T ❑ Yes ❑ Corps
❑ No ❑ DWQ
W3 ❑ P❑ T ❑ Yes ❑ Corps
❑ No ❑ DWQ
W4 ❑ P � T ❑ Yes ❑ Corps
❑ No ❑ DWQ
WS ❑ P❑ T ❑ Yes ❑ Corps
❑ No ❑ DWQ
W6 ❑ P❑ T ❑ Yes ❑ Corps
❑ No ❑ DWQ
2g. Total wetland impacts
2h. Comments:
3. Stream Impacts
If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this
question for all stream sites impacted.
3a. 3b. 3c. 3d. 3e. 3f. 3g.
Stream impact Type of impact Stream name Perennial Type ofjurisdiction Average Impact
number - (PER) or (Corps - 404, 10 stream length
Permanent (P) or intermittent DWQ — non-404, W�dth (linear
Temporary (� (IN"�? other) (feet) feet)
51 � P❑ T `Reinforced Box prong Creek � PER � Corps 6$ 98
Culvert ❑ INT ❑ DWQ
S2 � P❑ T Bank Stabilization Prong Creek � PER � Corps 6-8 69
❑ INT ❑ DWQ
S3 ❑ P� T Dewatering (dikes prong Creek � PER ❑ Corps 6-8 167
and pump around) ❑ INT � DWQ
S4 ❑ P❑ T ❑ PER ❑ Corps
❑ INT ❑ DWQ
S5 ❑ P❑ T ❑ PER ❑ Corps
❑ INT ❑ DWQ
S6 ❑ P❑ T ❑ PER ❑ Corps
❑ INT ❑ DWQ
3h. Total stream and tributary impacts "167(P)
167(T)
3i. Comments: *Culvert Size: (3) @ 10' X S' w/ top edge bevel and wingwalis; 1 barrel w/1' sill; 2 barrels w/2' sills.
'* NCDOT proposes mitigation for the permanent 98' RCBC impact only.
Page 4 of 10
PCN Form — Version 1.3 December 10, 2008 Version
4. Open Water Impacts
If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of
the U.S. then individually list all open water impacts below.
4a. 4b. 4c. 4d. 4e.
Open water Name of waterbody
impact number (if applicable) Type of impact Waterbody type Area of impact (acres)
— Permanent
(P) or
Tem ora T
01 ❑P❑T
02 ❑P❑T
03 ❑P❑T
04 ❑P❑T
4f. Total open water impacts
4g. Comments:
5. Pond or Lake Construction
If ond or lake construction ro osed, then com lete the chart below.
5a. 5b. 5c. Sd. 5e.
Wetland Impacts (acres) Stream Impacts (feet) Upland
Pond ID Proposed use or purpose of (acres)
number pond
Flooded Filled Excavated Flooded Filled Excavated Flooded
P1
P2
Sf. Total
Sg. Comments:
5h. Is a dam high hazard permit required?
❑ Yes ❑ No If yes, permit ID no:
5i. Expected pond surtace area (acres):
5j. Size of pond watershed (acres):
5k. Method of construction:
Page 5 of 10
PCN Form — Version 1.3 December 10, 2008 Version
6. Buffer Impacts (for DWQ)
If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts
below. If an im acts re uire miti ation, then ou MUST fill out Section D of this form.
6a.
❑ Neuse ❑ Tar-Pamlico ❑ Other:
Project is in which protected basin? ❑ Catawba ❑ Randleman
6b. 6c. 6d. 6e. 6f. 6g.
Buffer impact
number— Reason for Buffer Zone 1 impact Zone 2 impact
Permanent (P) impact Stream name mitigation (square feet) (square feet)
or Temporary required?
T
B1 � P❑ T Bridge ❑ Yes
Replacement ❑ No
B2 ❑P❑T ❑Yes
❑ No
B3 ❑P❑T ❑Yes
❑ No
6h. Total buffer impacts
6i. Comments:
D. Impact Justification and Mitigation
1. Avoidance and Minimization
1 a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project.
The same crossing location will be used. High and low flow barrels to provide aquatic passage.
1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. An
off-site detour will be utilized to serve local traffic. Impacts to the stream will be minimized by dewatering the construction area
following the removal of the existing bridge. Dewatering will be accomplished through the installation of impervious dikes
upstream and downstream of the proposed structure. Flooding from storms will be pumped out through silt bags and
discharged into the nearest sediment basin. Silt fencing will limit sediment intrusion.
2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State
2a. Does the project require Compensatory Mitigation for � Yes ❑ No
impacts to Waters of the U.S. or Waters of the State?
2b. If yes, mitigation is required by (check all that apply): ❑ DWQ � Corps
❑ Mitigation bank
2c. If yes, which mitigation option will be used for this project? � Payment to in-lieu fee program
❑ Permittee Responsible Mitigation
3. Complete if Using a Mitigation Bank
3a. Name of Mitigation Bank: NA
3b. Credits Purchased (attach receipt and letter) Type Quantity
Page 6 of 10
PCN Form — Version 1.3 December 10, 2008 Version
3c. Comments:
4. Complete if Making a Payment to In-lieu Fee Program
4a. Approval letter from in-lieu fee program is attached. � Yes
4b. Stream mitigation requested: 981inearfeet
4c. If using stream mitigation, stream temperature: � warm ❑ cool ❑cold
4d. Buffer mitigation requested (DWQ only): square feet
4e. Riparian wetland mitigation requested: acres
4f. Non-riparian wetland mitigation requested: acres
4g. Coastal (tidal) wetland mitigation requested: acres
4h. Comments:
5. Complete if Using a Permittee Responsible Mitigation Plan
5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan.
6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ
6a. Will the project result in an impact within a protected riparian buffer that requires ❑ Yes � No
buffer mitigation?
6b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the
amount of mitigation required.
6c. 6d. 6e.
Zone Reason for impact Total impact Multiplier Required mitigation
(square feet) (square feet)
Zone 1 3(2 for Catawba)
Zone 2 1.5
6f. Total buffer mitigation required:
6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank,
permittee responsible riparian buffer restoration, payment into an approved in-lieu fee fund).
6h. Comments:
Page 7 of 10
PCN Form — Version 1.3 December 10, 2008 Version
E. Stormwater Management and Diffuse Flow Plan (required by DWQ)
1. Diffuse Flow Plan
1 a. Does the project include or is it adjacent to protected riparian buffers identified � Yes � No
within one of the NC Riparian Buffer Protection Rules?
1 b. If yes, then is a diffuse flow plan included? If no, explain why.
Comments: ❑ Yes ❑ No
2. Stormwater Mana ement Plan
2a. What is the overall percent imperviousness of this project? NA
2b. Does this project require a Stormwater Management Plan? � Yes ❑ No
2c. If this project DOES NOT require a Stormwater Management Plan, explain why:
2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan:
The project will be completed in accordance with the NCDOT BMP manual to the maximum extent practicable.
Construction stormwater management will comply with NCS 000250.
❑ Certified Local Government
2e. Who will be responsible for the review of the Stormwater Management Plan? � DWQ Stormwater Program
❑ DWQ 401 Unit
3. Certified Local Government Stormwater Review
3a. In which local governmenYs jurisdiction is this project?
❑ Phase II
3b. Which of the following locally-implemented stormwater management programs � NSW
apply (check all that apply): ❑ USMP
❑ Water Supply Watershed
❑ Other:
3c. Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ❑ No
attached?
4. DWQ Stormwater Pro ram Review
❑ Coastal counties
❑ HQW
4a. Which of the following state-implemented stormwater management programs apply � ORW
(check all that apply):
❑ Session Law 2006-246
❑ Other: NPDES
4b. Has the approved Stormwater Management Plan with proof of approval been
attached? � Yes ❑ No
5. DWQ 401 Unit Stormwater Review
5a. Does the Stormwater Management Plan meet the appropriate requirements? ❑ Yes ❑ No
Sb. Have all of the 401 Unit submittal requirements been met? ❑ Yes ❑ No
Page 8 of 10
PCN Form — Version 1.3 December 10, 2008 Version
F. Supplementary Information
1. Environmental Documentation (DWQ Requirement)
1 a. Does the project involve an expenditure of public (federal/state/local) funds or the � Yes ❑ No
use of public (federal/state) land?
1 b. If you answered "yes" to the above, does the project require preparation of an
environmental document pursuant to the requirements of the National or State ❑ Yes � No
(North Carolina) Environmental Policy Act (NEPA/SEPA)?
1 c. If you answered "yes" to the above, has the document review been finalized by the
State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval
letter.)
❑ Yes ❑ No
Comments: A Minimum Criteria Rule Compliance/MC Checklist was prepared by
the NCDOT.
2. Violations (DWQ Requirement)
2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated
Wetland Rules (15A NCAC 2H .1300), DWQ Surtace Water or Wetland Standards, ❑ Yes � No
or Riparian Buffer Rules (15A NCAC 26 .0200)?
2b. Is this an after-the-fact permit application? ❑ Yes � No
2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s):
3. Cumulative Impacts (DWQ Requirement)
3a. Will this project (based on past and reasonably anticipated future impacts) result in � Yes � No
additional development, which could impact nearby downstream water quality?
3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the
most recent DWQ policy. If you answered "no," provide a short narrative description.
Due to the minimal transportation impact resulting from this bridge replacement, this project will neither influence nearby
land uses nor stimulate growth. Therefore, a detailed indirect of cumulative effects study will not be necessary.
4. Sewage Disposal (DWQ Requirement)
4a. Clearly detail the ultimate treatment methods and disposition (non-discharge or discharge) of wastewater generated from
the proposed project, or available capacity of the subject facility.
NA
Page 9 of 10
PCN Form — Version 1.3 December 10, 2008 Version
5. Endangered Species and Designated Critical Habitat (Corps Requirement)
Sa. Will this project occur in or near an area with federally protected species or
habitat? ❑ Yes � No
5b. Have you checked with the USFWS concerning Endangered Species Act � Yes
impacts? � No
� Raleigh
5c. If yes, indicate the USFWS Field Office you have contacted.
❑ Asheville
5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical
Habitat?
A review of GIS NC Natural Heritage Program (NHP) elemental occurrence data obtained from NC One Map, updated
January 2014, was conducted. It was found that there are no NHP elemental occurrences of Federally Endangered
Species within 2 miles of Bridge 440.
6. Essential Fish Habitat (Corps Requirement)
6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes � No
6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat?
NOAA Essential Fish Habitat Mapper v3.0
7. Historic or Prehistoric Cultural Resources (Corps Requirement)
7a. Will this project occur in or near an area that the state, federal or tribal
governments have designated as having historic or cultural preservation � Yes � No
status (e.g., National Historic Trust designation or properties significant in
North Carolina history and archaeology)?
7b. What data sources did you use to determine whether your site would impact historic or archeological resources?
An Archaeology - No Survey Required Form was completed by NCDOT Cultural Resources Specialist.
A Historic- No Sunrey Required Form was completed by NCDOT Cultural Resources Specialist.
8. Plood Zone Designation (Corps Requirement)
8a. Will this project occur in a FEMA-designated 100-year floodplain? � Yes ❑ No
8b. If yes, explain how project meets FEMA requirements: NCDOT Hydraulics coordination with FEMA.
Sc. What source(s) did you use to make the floodplain determination? FEMA Maps
/T..'� ( � � /!?� / V�� `% . ��__ /�` j ` ��
/_
Applicant/ genYs . rinted Name � " ° Date
ApplicanUAgenYs Signature�
(AgenYs signature is valid only if an authorization letter from the applicant
is rovidedJ
Page 10 of 10
PCN Form — Version 1.3 December 10, 2008 Version
P507
Lineberry Lake
C
r
e
e
k
Benny Lineberry
Rd
.
R
o
ut
h
R
d
.
Oakley Rd.
J
e
s
s
H
ackett
Rd.
Old
Lib
e
rty
Rd.
O
ld
Liberty
Rd.
Lineberry
Rd.
Tree
R
d.
Bruce
Pugh
M
a
m
i
e
M
a
y
Rd
.
Rd.Kings
Way
Rd.
Williams
R
o
u
t
h
C
ro
o
k
e
d
C
r
e
e
k
R
d
.
Grays Chapel
School Rd.
2138
2445
2261
2446
2448
2514
2447
2449
2140
2132
2448
2261
2140
2198
2261
2261
2445
2381
Lineberry
Chapel
Grays
22
22
Creek
Prong
Branch
Sandy
Creek
See Sheet 1-A For Index of Sheets
1
7
B
P
.
8
.
R
.
6
0
&
1
7
B
P
.
8
.
R
.
6
1
OFF-SITE DETOUR ROUTE
VICINITY MAP
See Sheet 1-C For Survey Control Sheet
See Sheet 1-B For Conventional symbols
N
C
G
RI
D
N
A
D
8
3
N
A
2
0
11
LENGTH OF ROADWAY PROJECT 17BP.8.R.60 = 0.040 MI
LENGTH OF STRUCTURE PROJECT 17BP.8.R.60 = 0.006 MI
TOTAL LENGTH OF PROJECT 17BP.8.R.60 = 0.046 MI
RANDOLPH COUNTY
BRIDGE NO. 440 (17BP.8.R.60) ON SR 2261 (OLD LIBERTY RD.)
OVER PRONG CREEK
GRADING, PAVING, DRAINAGE & STRUCTURE
DHV
D
T
V
=
=
=
=
=
=
%
%
MPH
ADT
ADT
% *
DUAL
* TTST =
FUNC CLASS =
TIER
0
0
0
PROFILE (HORIZONTAL)
PROJECT LENGTH
RIGHT OF WAY DATE:
LETTING DATE:
STATE STATE PROJECT REFERENCE NO.
STATE PROJ. NO.F. A. PROJ. NO.DESCRIPTION
NO.
TOTAL
SHEETS
N.C.
SHEET
1
DESIGN DATA
Prepared in the Office of:
SIGNATURE:
SIGNATURE:
P.E.
P.E.
2012 STANDARD SPECIFICATIONS
PROJECT ENGINEER
PROJECT DESIGN ENGINEER
GRAPHIC SCALES
PLANS
PROFILE (VERTICAL)
HYDRAULICS ENGINEER
ENGINEER
ROADWAY DESIGN
LOCATION:
TYPE OF WORK:
0
9
/
0
8
/
9
9
17BP.8.R.60DIVISION OF HIGHWAYS
STATE OF NORTH CAROLINA
0
00
See Sheet 1-A For Index of Sheets
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
C
O
N
T
R
A
C
T
:
T
I
P
P
R
O
J
E
C
T
:
1
7
B
P
.
8
.
R
.
6
0
A
R
T
MEN
N
A
S
O
H
D
E
P
T
O
F TRA S PORT
T
I
O
N
T
A TEOFN RT
C AR
O
LI
N
A
TIM WELCH, PESEPT. 23, 2014
MARCH, 2014
NCDOT CONTACT
AGNIESZKA NAU, PE
TIM WELCH, PE
5
TO NC HWY 22 TO US H
WY 421
17BP.8.R.60 (BR 440)
-L2- STA. 11+35.00
BEGIN PROJECT
-L2-
OLD LIBERTY ROAD
SR 2261
17BP.8.R.60 (BR 440)
-L2- STA. 13+80.00
END PROJECT
P
R
ON
G C
R
E
E
K
PROJECT
17BP.8.R.60 PE
17BP.8.R.60 R/W & UTIL
STREAM IMPACTS
PERM, STREAM
IMPACTS
DENOTES TEMPORARY
IMPACTS IN SURFACE WATER
DENOTES BANK
STABILIZATION
PROJECT REFERENCE NO. SHEET NO.
178P.8R.6O 2
R/N SHEET NO.
PERM. STREAM
IMPACTS
DENOTES BANK
STABILIZATION
DENOTES TEMPORARY
IMPACTS IN SURFACE WATER
l7BP.BRb0
3
v
PERM. STREAM
IMPACTS
DENOTES TEMPORARY
IMPACTS IN SURFACE WAT
DENOTES BANK
STABILIZATION
SPECIAL
STILLIN
BASIN
DENOTES TEMPORARY
IMPACTS IN SURFACE WATER
IR
IMPERVIOU
DIKE
IMPERVIOU
DIKE
L
879
17BP.8.R.60
57
SzEpU e! 919-789 99775
ENeINEENINe& Fea,919-19-91
CONSTRUCTION l,een.e1C-21959]
m
T
5
/
1
4
/
9
9 SHEET NO.PROJECT REFERENCE NO.
HYDRAULICSROADWAY DESIGN
ENGINEER ENGINEER
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
10 11 12 13 14 15
600
604
608
612
616
620
624
628
632
PI = 12+53.70
VC = 75’
EL = 624.82’
K = 121
DS = 55 MPH
(+)0.5972%(-)0.0218%6
2
4
.11
6
2
4
.7
9
E
L
E
V
=
6
2
2
.0
0
P
I
=
11+
2
5
L
T
(
-
)
5.
40
0
0%
(-
)6.
3
6
0
0%
(-
)4
.3
3
3
3%
E
L
E
V
=
6
19
.0
0
P
I
=
11+
7
5
L
T
(+)1.6286%
E
L
E
V
=
6
17
.0
7
P
I
=
13
+
0
0
L
T
(+)2.4200%(+)10.0000%
E
L
E
V
=
6
18
.2
8
P
I
=
13
+
5
0
L
T
E
L
E
V
=
6
2
0
.7
8
P
I
=
13
+
7
5
L
T
(+)5.7200%
E
L
E
V
=
6
2
3
.5
9
P
I
=
11+
0
0
L
T
B
E
G
I
N
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
6
17
.0
5
P
I
=
12
+
2
0
L
T
E
N
D
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
6
16
.5
0
P
I
=
12
+
6
5
L
T
B
E
G
I
N
D
I
T
C
H
G
R
A
D
E E
L
E
V
=
6
2
5
.0
7
P
I
=
14
+
5
0
L
T
E
N
D
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
6
2
3
.5
9
P
I
=
11+
0
0
L
T
E
L
E
V
=
6
2
2
.0
0
P
I
=
11+
2
5
L
T
E
L
E
V
=
6
19
.0
0
P
I
=
11+
7
5
L
T
E
L
E
V
=
6
17
.0
5
P
I
=
12
+
2
0
L
T
E
L
E
V
=
6
16
.5
0
P
I
=
12
+
6
5
L
T
E
L
E
V
=
6
17
.0
7
P
I
=
13
+
0
0
L
T
E
L
E
V
=
6
18
.2
8
P
I
=
13
+
5
0
L
T
E
L
E
V
=
6
2
0
.7
8
P
I
=
13
+
7
5
L
T
E
L
E
V
=
6
2
5
.0
7
P
I
=
14
+
5
0
L
T
(+)5.7200%
(+)10.0000%
(+)2.4200%
(+)1.6286%
(
-
)
5.
4
0
0
0%
(-
)6.
3
6
0
0%
(-
)4
.3
3
3
3%
DESIGN DISCHARGE
DESIGN FREQUENCY
BASE DISCHARGE
CFS
YRS
YRS
BASE FREQUENCY
OVERTOPPING ELEVATION
OVERTOPPING FREQUENCY
OVERTOPPING DISCHARGE CFS
CFS
YRS
FT
FT
FT
DESIGN HW ELEVATION
BASE HW ELEVATION
CULVERT HYDRAULIC DATA
= 500
= 25
= 618.0
= 800
= 100
= 618.84
= 2,350
= 500+
= 624.4 OFF 59.47’ RT
Sta. 11+38.45
-L2-
OF 15" POPLAR
RR SPIKE IN BASE
ELEV. 617.64’
OFF 43’ RT
Sta. -BL- 6+51.00
BM 1
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
NOTE: SEE SHEETS S-1 THRU S-X FOR STRUCTURE PLANS
NOTE: SEE PLAN SHEET 5 FOR PLAN
-L2- STA. 11+35.00
BEGIN GRADE
-L2- STA. 13+80.00
END GRADE
-L2- (BR 440)
17BP.8.R.60 4
Ha
n
d
Ex
i
s
t
i
n
g
E
x
i
s
t
i
n
g
Pe
r
m
a
n
e
n
t
T
e
m
p
.
E
x
c
a
v
a
t
i
o
n
M
e
c
h
a
n
i
z
e
d
C
l
e
a
r
i
n
g
P
e
r
m
a
n
e
n
t
T
e
m
p
.
C
h
a
n
n
e
l
C
h
a
n
n
e
l
N
a
t
u
r
a
l
Si
t
e
S
t
a
t
i
o
n
S
t
r
u
c
t
u
r
e
F
i
l
l
I
n
F
i
l
l
I
n
i
n
C
l
e
a
r
i
n
g
i
n
S
W
S
W
I
m
p
a
c
t
s
I
m
p
a
c
t
s
S
t
r
e
a
m
No
.
(
F
r
o
m
/
T
o
)
S
i
z
e
/
T
y
p
e
W
e
t
l
a
n
d
s
W
e
t
l
a
n
d
s
W
e
t
l
a
n
d
s
i
n
W
e
t
l
a
n
d
s
W
e
t
l
a
n
d
s
i
m
p
a
c
t
s
i
m
p
a
c
t
s
P
e
r
m
a
n
e
n
t
T
e
m
p
.
D
e
s
i
g
n
(a
c
)
(
a
c
)
(
a
c
)
(
a
c
)
(
a
c
)
(
a
c
)
(
a
c
)
(
f
t
)
(
f
t
)
(
f
t
)
1
1
1
+
9
8
T
O
1
2
+
5
1
-
L
-
3
@
1
0
'
x
8
'
<0
.
1
9
8
.
2
RC
B
C
2
1
2
+
0
7
T
O
1
2
+
6
0
-
L
-
B
a
n
k
s
t
a
b
i
l
i
z
a
t
i
o
n
<
0
.
1
6
9
.
2
3
1
2
+
0
7
T
O
1
2
+
6
0
-
L
-
D
r
y
w
o
r
k
a
r
e
a
&
<0
.
1
1
6
7
.
4
Pu
m
p
a
r
o
u
n
d
TO
T
A
L
S
:
0
.
0
0
.
0
0
.
0
0
.
0
0
.
0
<
0
.
1
<
0
.
1
1
6
7
.
4
1
6
7
.
4
0
.
0
AT
N
R
e
v
i
s
e
d
3
/
3
1
/
0
5
SH
E
E
T
6
/
3
0
/
2
0
1
4
W
E
T
L
A
N
D
P
E
R
M
I
T
I
M
P
A
C
T
S
U
M
M
A
R
Y
SU
R
F
A
C
E
W
A
T
E
R
I
M
P
A
C
T
S
WE
T
L
A
N
D
I
M
P
A
C
T
S
RA
N
D
O
L
P
H
C
O
U
N
T
Y
BR
G
.
4
4
0
O
V
E
R
P
R
O
N
G
C
R
E
E
K
NC
D
E
P
A
R
T
M
E
N
T
O
F
T
R
A
N
S
P
O
R
T
A
T
I
O
N
DI
V
I
S
I
O
N
O
F
H
I
G
H
W
A
Y
S
AL
O
N
G
S
R
2
2
6
1
O
L
D
L
I
B
E
R
T
Y
R
O
A
D
)
P507
Lineberry Lake
C
r
e
e
k
Benny Lineberry
Rd
.
R
o
ut
h
R
d
.
Oakley Rd.
J
e
s
s
H
ackett
Rd.
Old
Lib
e
rty
Rd.
O
ld
Liberty
Rd.
Lineberry
Rd.
Tree
R
d.
Bruce
Pugh
M
a
m
i
e
M
a
y
Rd
.
Rd.Kings
Way
Rd.
Williams
R
o
u
t
h
C
r
o
o
k
e
d
Cr
e
e
k
R
d
.
Grays Chapel
School Rd.
2138
2445
2261
2446
2448
2514
2447
2449
2140
2132
2448
2261
2140
2198
2261
2261
2445
2381
Lineberry
Chapel
Grays
22
22
Creek
Prong
Branch
Sandy
Creek
TO NC HWY 22 TO US H
WY 421
N
C
G
RI
D
N
A
D
8
3
N
A
2
0
11
RANDOLPH COUNTY
PROJECT LENGTH
RIGHT OF WAY DATE:
LETTING DATE:
STATE STATE PROJECT REFERENCE NO.
STATE PROJ. NO.F. A. PROJ. NO.DESCRIPTION
NO.
TOTAL
SHEETS
N.C.
SHEET
1
DESIGN DATA
SIGNATURE:
SIGNATURE:
P.E.
P.E.
2012 STANDARD SPECIFICATIONS
GRAPHIC SCALES
HYDRAULICS ENGINEER
ENGINEER
ROADWAY DESIGN
LOCATION:
TYPE OF WORK:
0
9
/
0
8
/
9
9
DIVISION OF HIGHWAYS
STATE OF NORTH CAROLINASee Sheet 1-A For Index of Sheets
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
C
O
N
T
R
A
C
T
:
A
R
T
MEN
N
A
S
O
H
D
E
P
T
O
F TRA S PORT
T
I
O
N
T
A TEOFN RT
C AR
O
LI
N
A
4 5
P
R
ON
G C
R
E
E
K
-L2-
OLD LIBERTY ROAD
SR 2261
GRADING, DRAINAGE, PAVING, & STRUCTURE
1
7
B
P
.
8
.
R
.
6
0
&
1
7
B
P
.
8
.
R
.
6
1
P
R
O
J
E
C
T
:
17BP.8.R.61
17BP.8.R.60 &
0
0
0
PROFILE (HORIZONTAL)
PLANS
PROFILE (VERTICAL)
0
00
502550
2010510
20 401020
100
T
V
=
=MPH
% *
2013
SUB-REGIONAL TIER
7
* TTST =3%DUAL 4%
55
PROJECT ENGINEER
PROJECT DESIGN ENGINEER
AGNIESZKA NAU, PE
NCDOT CONTACT
TIM WELCH, PE
OFF-SITE DETOUR ROUTE
VICINITY MAP
See Sheet 1-C For Survey Control Sheet
See Sheet 1-B For Conventional symbols
LENGTH OF ROADWAY PROJECT 17BP.8.R.60 = 0.040 MI
LENGTH OF STRUCTURE PROJECT 17BP.8.R.60 = 0.006 MI
TOTAL LENGTH OF PROJECT 17BP.8.R.60 = 0.046 MI
LENGTH OF ROADWAY PROJECT 17BP.8.R.61 = 0.069 MI
LENGTH OF STRUCTURE PROJECT 17BP.8.R.61 = 0.004 MI
TOTAL LENGTH OF PROJECT 17BP.8.R.61 = 0.073 MI
N
C
G
RI
D
N
A
D
8
3
N
A
2
0
11
TO US HWY 421T
O
N
C
H
WY 22
C
R
E
E
K
B
R
ANC
H
S
AN
D
Y
OLD LIBERTY ROAD
SR 2261
-L1-
LOCATION
PROJECT
Prepared in the Office of:
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
FOR THE NORTH CAROLINA DEPT. OF TRANSPORATION=822-L1- ADT
COLLECTOR
FUNC CLASS = MAJOR
2013 =-L2- ADT 1,530
BRIDGE NO. 439 (17BP.8.R.61) ON SR 2261 (OLD LIBERTY RD.)
OVER BRANCH SANDY CREEK & BRIDGE NO. 440 (17BP.8.R.60) ON
SR 2261 (OLD LIBERTY RD.) OVER PRONG CREEK
17BP.8.R.60 PE
17BP.8.R.61 PE
MARCH, 2014
SEPT. 23, 2014
17BP.8.R.60 (BR 440)
-L2- STA. 11+35.00
BEGIN PROJECT
17BP.8.R.60 (BR 440)
-L2- STA. 13+80.00
END PROJECT
17BP.8.R.61 (BR 439)
-L1- STA. 10+80.00
BEGIN PROJECT
17BP.8.R.61 (BR 439)
-L1- STA. 14+65.00
END PROJECT
17BP.8.R.60
17BP.8.R.61
R/W & UTIL.
R/W & UTIL.
STEVE SCOTT, PE
17BP.8.R.60 CONST.
17BP.8.R.61 CONST.
SHEET NO.PROJECT REFERENCE NO.
1-A
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
1
7
/
9
9
17BP.8.R.61
17BP.8.R.60 &
INDEX OF SHEETS
SHEET NUMBER SHEET
1 TITLE SHEET
1-A INDEX OF SHEETS, GENERAL NOTES, AND LIST OF
STANDARD DRAWINGS
1-B CONVENTIONAL SYMBOLS
2 PAVEMENT SCHEDULE, TYPICAL SECTIONS, AND
WEDGING DETAILS
5 PLAN SHEET FOR -L2- (440)
6 PROFILE SHEET FOR -L1- (439)
7 PROFILE SHEET FOR -L2- (440)
4 PLAN SHEET FOR -L1- (439)
1-C SURVEY CONTROL SHEET (439)
1-D SURVEY CONTROL SHEET (440)
3B GAURDRAIL SUMMARY & EARTHWORK
X-1 CROSS SECTION INDEX
ALL RIGHT-OF-WAY MARKERS ON THIS PROJECT SHALL BE PLACED BY CONTRACT.
RIGHT-OF-WAY MARKERS:
ANY RELOCATION OF EXISTING UTILITIES WILL BE ACCOMPLISHED BY OTHERS.
UTILITIES:
MAKE HIS OWN INVESTIGATION AS TO THE SUBSURFACE CONDITIONS.
NO SUBSURFACE PLANS ARE AVAILABLE ON THIS PROJECT. THE CONTRACTOR SHOULD
SUBSURFACE PLANS:
WITH THE ENGINEER PRIOR TO ORDERING GUARDRAIL MATERIAL.
CONSTRUCTION AS DIRECTED BY THE ENGINEER. THE CONTRACTOR SHOULD CONSULT
THE GUARDRAIL LOCATIONS SHOWN ON THE PLANS MAY BE ADJUSTED DURING
GUARDRAIL:
SUPERELEVATED CURVES SHALL BE IN ACCORDANCE WITH STD. NO. 560.01.
ASPHALT, EARTH, AND CONCRETE SHOULDER CONSTRUCTION ON THE HIGH SIDE OF
SHOULDER CONSTRUCTION:
SECTIONS.
SUPERELEVATION IS TO BE REVOLVED ABOUT THE GRADE POINTS SHOWN ON THE TYPICAL
NO. 225.04 USING THE RATE OF SUPERELEVATION AND RUNOFF SHOWN ON THE PLANS.
ALL CURVES ON THIS PROJECT SHALL BE SUPERELEVATED IN ACCORDANCE WITH STD.
SUPERELEVATION:
ENGINEER IN ORDER TO SECURE A PROPER TIE-IN.
ADJUSTED AT THEIR BEGINNING AND ENDING AND AT STRUCTURES AS DIRECTED BY THE
SURFACING AT GRADE POINTS SHOWN ON THE TYPICAL SECTIONS. GRADE LINES MAY BE
THE GRADE LINES SHOWN DENOTE THE FINISHED ELEVATION OF THE PROPOSED
GRADING AND SURFACING:
GRADE LINE:
REVISED: 11-01-11
EFFECTIVE: 01-17-12
GENERAL NOTES: 2012 SPECIFICATIONS
876.04 Drainage Ditches with Class ’B’ Rip Rap
876.02 Guide for Rip Rap at Pipe Outlets
862.02 Guardrail Installation
862.01 Guardrail Placement
DIVISION 8 - INCIDENTALS
Curve - Method I
560.01 Method of Shoulder Construction - High Side of Superelevated
DIVISION 5 - SUBGRADE, BASES AND SHOULDERS
310.10 Driveway Pipe Construction
DIVISION 3 - PIPE CULVERTS
225.04 Method of Obtaining Superelevation - Two Lane Pavement
225.02 Guide for Grading Subgrade - Secondary and Local
200.03 Method of Clearing - Method III
DIVISION 2 - EARTHWORK
STD.NO. TITLE
a part of these plans:
July 18, 2006 are applicable to this project and by reference hereby are considered
Design Branch - N. C. Department of Transportation - Raleigh, N. C., Dated
The following Roadway Standards as appear in "Roadway Standard Drawings" Highway
2012 ROADWAY ENGLISH STANDARD DRAWINGS
REV. 11-01-11
EFF. 01-17-12
UO-1 THRU UO-3 UTILITIES PLANS
SN-1 STRUCTURE STANDARD NOTES
TMP-1 THRU TMP-4 TRAFFIC CONTROL FOR -L1- (439)
TMP-1 THRU TMP-4 TRAFFIC CONTROL FOR -L2- (440)
EC-1 THRU EC-5 TRAFFIC CONTROL FOR -L1- (439)
EC-1 THRU EC-5 TRAFFIC CONTROL FOR -L2- (440)
X-2 THRU X-8 CROSS-SECTIONS FOR -L1- (439)
X-9 THRU X-13 CROSS-SECTIONS FOR -L2- (440)
C-1 THRU C-12 STRUCTURE PLANS FOR -L1- 439 AND -L2- 440
3A DRAINAGE SUMMARY
Existing Edge of Pavement
Existing Curb
Proposed Slope Stakes Cut
Proposed Slope Stakes Fill
Existing Metal Guardrail
Existing Cable Guiderail
Proposed Guardrail
Equality Symbol
Pavement Removal
Baseline Control Point
RIGHT OF WAY:
Existing Right of Way Marker
Existing Right of Way Line
h
Existing Control of Access
Proposed Control of Access
Proposed Right of Way Line
C
F
Existing Easement Line
Proposed Temporary Construction Easement
Proposed Temporary Drainage Easement
Proposed Permanent Drainage Easement
Proposed Permanent Utility Easement
HYDROLOGY:
Stream or Body of Water
Hydro, Pool or Reservoir
Flow Arrow
Disappearing Stream
Spring
;
z
v
W
K
Proposed Lateral, Tail, Head Ditch
False Sump
Proposed Cable Guiderail
MAJOR:
Bridge, Tunnel or Box Culvert
Bridge Wing Wall, Head Wall and End Wall
MINOR:
Head and End Wall
Pipe Culvert
Footbridge
Paved Ditch Gutter
UTILITIES:
ROADS AND RELATED FEATURES:
Existing Power Pole
Proposed Power Pole
P
U/G Power Cable Hand Hole
Power Manhole
Power Line Tower
Power Transformer
Existing Joint Use Pole
Proposed Joint Use Pole
Existing Telephone Pole
Proposed Telephone Pole
Telephone Manhole
Telephone Booth
Telephone Pedestal
U/G Telephone Cable Hand Hole
R
}
T
p
Q
l
e
]
/
b
H-Frame Pole O O
POWER:
TELEPHONE:
Telephone Cell Tower
Recorded U/G Power Line
Recorded U/G Telephone Cable
Designated U/G Telephone Cable (S.U.E.*)
Recorded U/G Telephone Conduit
Designated U/G Telephone Conduit (S.U.E.*)
Recorded U/G Fiber Optics Cable
WATER:
Water Manhole
Water Meter
Water Valve
Water Hydrant
Recorded U/G Water Line
4
I
H
a
TV:
TV Satellite Dish
TV Pedestal
TV Tower
U/G TV Cable Hand Hole
Recorded U/G TV Cable
Recorded U/G Fiber Optic Cable
Designated U/G Fiber Optic Cable (S.U.E.*)
r
|
I
]
GAS:
Gas Valve
Gas Meter
Recorded U/G Gas Line
n
c
SANITARY SEWER:
Sanitary Sewer Manhole
Sanitary Sewer Cleanout
U/G Sanitary Sewer Line
Recorded SS Forced Main Line
Designated SS Forced Main Line (S.U.E.*)
d
o
A/G Water
Above Ground Gas Line
A/G Gas
Above Ground Water Line
Above Ground Sanitary Sewer A/G Sanitary Sewer
MISCELLANEOUS:
Utility Pole O
F
S
3
Utility Pole with Base
Utility Located Object
Utility Traffic Signal Box
Utility Unknown U/G Line
?
CONC
CONC WW
v
v
Drainage Box: Catch Basin, DI or JB
Storm Sewer
Storm Sewer Manhole m
U/G Tank; Water, Gas, Oil
A/G Tank; Water, Gas, Oil
BOUNDARIES AND PROPERTY:
State Line
County Line
Township Line
City Line
Reservation Line
Property Line
Existing Iron Pin
Property Corner
Property Monument
Existing Fence Line
Proposed Woven Wire Fence
Proposed Chain Link Fence
Proposed Barbed Wire Fence
g
F
123
Existing Wetland Boundary
Proposed Wetland Boundary
Existing Endangered Animal Boundary
Existing Endangered Plant Boundary
BUILDINGS AND OTHER CULTURE:
Area Outline
Gas Pump Vent or U/G Tank Cap
Church
School
Dam
Sign
Small Mine
Well
V
M
WW
S
x
Foundation
S
Building
y
y
VEGETATION:
Single Tree X
Y
Vineyard
Single Shrub
Hedge
Woods Line
Orchard
Vineyard
RAILROADS:
Standard Gauge
RR Signal Milepost
Switch
RR Abandoned
RR Dismantled
S
FLOW
Designated U/G Power Line (S.U.E.*)
Designated U/G Fiber Optics Cable (S.U.E.*)
Designated U/G Water Line (S.U.E.*)
Designated U/G TV Cable (S.U.E.*)
Designated U/G Gas Line (S.U.E.*)
U/G Test Hole (S.U.E.*)
*S.U.E. = Subsurface Utility Engineering
WLB
EIP B
ECM
CONC HW
CB
CSX TRANSPORTATION
MILEPOST 35
SWITCH
Cemetery
EXISTING STRUCTURES:
Parcel / Sequence Number
E
AATUR
End of Information E.O.I.
Note: Not to Scale
SHEET NO.PROJECT REFERENCE NO.
Abandoned According to Utility Records
WLB
EAB
EPB
R
W
R
W
R
W
C
A
E
TDE
PDE
PUE
S
P
P
T
T
TC
TC
T FO
T FO
W
W
TV
TV
TV FO
TV FO
G
G
SS
FSS
FSS
?UTL
Jurisdictional Stream JS
1
2
/
0
5
/
1
1
Buffer Zone 1
Buffer Zone 2
BZ 1
BZ 2
Wetland
Proposed Permanent Easement with
Iron Pin and Cap Marker
Proposed Temporary Utility Easement TUE
Iron Pin and Cap Marker
Proposed Right of Way Line with
DUEProposed Permanent Drainage / Utility Easement
AUEProposed Aerial Utility Easement
CRProposed Curb Ramp
STATE OF NORTH CAROLINA
DIVISION OF HIGHWAYS
CONVENTIONAL PLAN SHEET SYMBOLS
Underground Storage Tank, Approx. Loc.
Geoenvironmental Boring
UST
Known Soil Contamination: Area or Site
Potential Soil Contamination: Area or Site
Concrete or Granite R/W Marker
Proposed Right of Way Line with
C
A Concrete C/A Marker
Proposed Control of Access Line with
1-B
17BP.8.R.61
17BP.8.R.60 &
N
C
G
RI
D
N
A
D
8
3
N
A
2
0
1
1
-BL- 101
-BL- 103
-BL- 102 RR-SPIKE IN BASE OF 24IN POPLAR TREE
BL STATION 9+01.00 63’ RIGHT
N 756372 E 1797094
BM1 ELEVATION = 603.38’
P507
Lineberry Lake
C
r
e
e
k
Benny Lineberry
Rd
.
R
o
ut
h
R
d
.
Oakley Rd.
J
e
s
s
H
ackett
Rd.
Old
Lib
e
rty
Rd.
O
ld
Liberty
Rd.
Lineberry
Rd.
Tree
R
d.
Bruce
Pugh
M
a
m
i
e
M
a
y
Rd.
Rd.Kings
Way
Rd.
Williams
R
o
u
t
h
Cr
o
o
k
e
d
C
re
e
k
R
d
.
Grays Chapel
School Rd.
2138
2445
2261
2446
2448
2514
2447
2449
2140
2132
2448
2261
2140
2198
2261
2261
2445
2381
Lineberry
Chapel
Grays
22
22
Creek
Prong
Branch
Sandy
Creek
See Sheet 1-A For Index of Sheets
1
7
B
P
.
8
.
R
.
6
0
&
1
7
B
P
.
8
.
R
.
6
1
OFF-SITE DETOUR ROUTE
VICINITY MAP
See Sheet 1-C For Survey Control Sheet
See Sheet 1-B For Conventional symbols
LOCATION
PROJECT
NOTE: DRAWING NOT TO SCALE
NOTES:
INDICATES GEODETIC CONTROL MONUMENTS USED OR SET FOR HORIZONTAL PROJECT CONTROL
BY THE NCDOT LOCATION AND SURVEYS UNIT.
SITE CALIBRATION INFORMATION HAS NOT BEEN PROVIDED FOR THIS PROJECT. IF FURTHER
INFORMATION IS NEEDED, PLEASE CONTACT THE LOCATION AND SURVEYS UNIT.
1. THE CONTROL DATA FOR THIS PROJECT WAS PROVIDED BY NCDOT.
CONTROL POINTS PROVIDED ARE AS FOLLOWS:
INDICATES CONTROL MONUMENTS USED OR SET FOR HORIZONTAL PROJECT CONTROL
BY NCDOT.
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
LOCALIZED PROJECT COORDINATES
E = 1,796,807.66’N = 756,067.92’
LOCALIZED PROJECT COORDINATES
N = 756,502.81’E = 1,797,040.49’
R
E
V
IS
I
O
N
S
R/W SHEET NO.
SHEET NO.PROJECT REFERENCE NO.
1-C17BP.8.R.61
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
1
7
/
9
9
OLD LIBERTY RD
SR 2261
-L1- STA. 10+00.00 BEGIN STATE PROJECT 17BP.8.R.61
-L1- STA. 15+30.08 END STATE PROJECT 17BP.8.R.61
CREEK
BRANCH SANDY
DATUM DESCRIPTION
THE LOCALIZED COORDINATE SYSTEM DEVELOPED FOR THIS PROJECT
IS BASED ON THE STATE PLANE COORDINATES ESTABLISHED BY
NCDOT FOR MONUMENT "750439-1"
WITH NAD 83/NA 2011 STATE PLANE GRID COORDINATES OF
NORTHING: 757145.042(ft) EASTING: 1797000.387(ft)
ELEVATION: 618.126(ft)
THE AVERAGE COMBINED GRID FACTOR USED ON THIS PROJECT
(GROUND TO GRID) IS: 0.9998983792
THE N.C. LAMBERT GRID BEARING AND
LOCALIZED HORIZONTAL GROUND DISTANCE FROM
ALL LINEAR DIMENSIONS ARE LOCALIZED HORIZONTAL DISTANCES
VERTICAL DATUM USED IS NAVD 88
S1008’39.70"W
"750439-1" TO -L1- STATION 10+00.00 IS 1094.2310’
750439-1 N=757,145.042 E=1,797,000.387 ELEV=618.126’
BL
------------ ---------------- ---------------- ---------------- ---------------- ---------------- ----------------
POINT DESC. NORTH EAST ELEVATION -L1- STATION OFFSET
101 BL-101 756055.1580 1796810.8560 604.58 OUTSIDE PROJECT LIMITS
102 BL-102 756297.1820 1797034.5760 596.32 13+26.13 13.13 RT
SURVEY CONTROL SHEET 17BP.8.R.61
103 BL-103 756583.6320 1797018.3260 606.53 OUTSIDE PROJECT LIMITS
-L1-
N
C
G
RI
D
N
A
D
8
3
N
A
2
0
11
-BL- 101
-BL- 103
-BL- 102
RR-SPIKE IN BASE OF 15IN POPLAR TREE
BL STATION 6+51.00 43’ RIGHT
N 758480 E 1797512
BM1 ELEVATION = 617.64’
P507
Lineberry Lake
C
r
e
e
k
Benny Lineberry
Rd
.
R
o
ut
h
R
d
.
Oakley Rd.
J
e
s
s
H
ackett
Rd.
Old
Lib
e
rty
Rd.
O
ld
Liberty
Rd.
Lineberry
Rd.
Tree
R
d.
Bruce
Pugh
M
a
m
i
e
M
a
y
Rd
.
Rd.Kings
Way
Rd.
Williams
R
o
u
t
h
C
r
o
o
k
e
d
C
re
e
k
R
d
.
Grays Chapel
School Rd.
2138
2445
2261
2446
2448
2514
2447
2449
2140
2132
2448
2261
2140
2198
2261
2261
2445
2381
Lineberry
Chapel
Grays
22
22
Creek
Prong
Branch
Sandy
Creek
See Sheet 1-A For Index of Sheets
1
7
B
P
.
8
.
R
.
6
0
&
1
7
B
P
.
8
.
R
.
6
1
OFF-SITE DETOUR ROUTE
VICINITY MAP
See Sheet 1-C For Survey Control Sheet
See Sheet 1-B For Conventional symbols
LOCATION
PROJECT
NOTE: DRAWING NOT TO SCALE
NOTES:
INDICATES GEODETIC CONTROL MONUMENTS USED OR SET FOR HORIZONTAL PROJECT CONTROL
BY THE NCDOT LOCATION AND SURVEYS UNIT.
SITE CALIBRATION INFORMATION HAS NOT BEEN PROVIDED FOR THIS PROJECT. IF FURTHER
INFORMATION IS NEEDED, PLEASE CONTACT THE LOCATION AND SURVEYS UNIT.
1. THE CONTROL DATA FOR THIS PROJECT WAS PROVIDED BY NCDOT.
CONTROL POINTS PROVIDED ARE AS FOLLOWS:
INDICATES CONTROL MONUMENTS USED OR SET FOR HORIZONTAL PROJECT CONTROL
BY NCDOT.
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
LOCALIZED PROJECT COORDINATES
E = 1,797,457.97’N = 758,350.23’
LOCALIZED PROJECT COORDINATES
N = 758,761.29’E = 1,797,670.11’
R
E
V
IS
I
O
N
S
R/W SHEET NO.
SHEET NO.PROJECT REFERENCE NO.
1-D17BP.8.R.60
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
1
7
/
9
9
PRONG CREEK
OLD LIBERTY RD
SR 2261
-L2- STA. 10+00.00 BEGIN STATE PROJECT 17BP.8.R.60
-L2- STA. 15+04.07 END STATE PROJECT 17BP.8.R.60
SURVEY CONTROL SHEET 17BP.8.R.60
DATUM DESCRIPTION
THE LOCALIZED COORDINATE SYSTEM DEVELOPED FOR THIS PROJECT
IS BASED ON THE STATE PLANE COORDINATES ESTABLISHED BY
NCDOT FOR MONUMENT "750439-1"
WITH NAD 83/NA 2011 STATE PLANE GRID COORDINATES OF
NORTHING: 757145.0420(ft) EASTING: 1797000.3870(ft)
ELEVATION: 618.126(ft)
THE AVERAGE COMBINED GRID FACTOR USED ON THIS PROJECT
(GROUND TO GRID) IS: 0.9998983792
THE N.C. LAMBERT GRID BEARING AND
LOCALIZED HORIZONTAL GROUND DISTANCE FROM
ALL LINEAR DIMENSIONS ARE LOCALIZED HORIZONTAL DISTANCES
VERTICAL DATUM USED IS NAVD 88
N2047’26.11"E
"750439-1" TO -L2- STATION 10+00.00 IS 1289.1354’
750439-1 N=757,145.0420 E=1,797,000.3870 ELEV=618.126’
BL
------------ ---------------- ---------------- ---------------- ---------------- ---------------- ----------------
POINT DESC. NORTH EAST ELEVATION -L2- STATION OFFSET
101 BL-101 758327.4790 1797475.6080 625.21 OUTSIDE PROJECT LIMITS
103 BL-103 758792.2450 1797706.0580 629.07 OUTSIDE PROJECT LIMITS
102 BL-102 758574.0150 1797464.5570 624.13 12+23.56 10.06’ LT
-L2-
2
INCOMPLETE PLANS
DO NOT USE FOR R/W ACQUISITION
DO NOT USE FOR CONSTRUCTION
PRELIMINARY PLANS
TYPICAL SECTION NO. 1
VA
R.
2:
1
M
A
X
CL
8%VAR. 2:1 TO 6:1
TYPICAL SECTION NO. 2
EXIST. GROUND
EXIST. GROUND
T
VAR
. TO
4
:1
NORMAL
VAR. 2:1 MAX
8%
VA
R.
2:
1
TO
6:
1
EXIST. GROUND
EXIST. GROUND
T
VAR. TO 4:1 NORMAL
VARIES VARIES
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
ROADWAY
R/W SHEET NO.5
/
1
4
/
9
9 SHEET NO.PROJECT REFERENCE NO.
PAVEMENT SCHEDULE
NOTE: PAVEMENT EDGE SLOPES ARE 1:1 UNLESS SHOWN OTHERWISE
C1
E1
T EARTH MATERIAL.
D1 TYPE I19.0B, AT AN AVERAGE RATE OF 342 LBS. PER SQ. YD.
PROP. APPROX. 3" ASPHALT CONCRETE INTERMEDIATE COURSE,
OF TWO LAYERS.
SF9.5A, AT AN AVERAGE RATE OF 110 LBS. PER SQ. YD. IN EACH
PROP. APPROX. 2" ASPHALT CONCRETE SURFACE COURSE, TYPE
B25.0B, AT AN AVERAGE RATE OF 627 LBS. PER SQ. YD.
PROP. APPROX. 5.5" ASPHALT CONCRETE BASE COURSE, TYPE
C2
BE PLACED IN LAYERS NOT TO EXCEED 1" IN DEPTH.
AT AN AVERAGE RATE OF 110 LBS. PER SQ. YD. PER 1" DEPTH. TO
PROP. VAR. DEPTH ASPHALT CONCRETE SURFACE COURSE, TYPE SF9.5A,
D2
THAN 4" IN DEPTH.
DEPTH, TO BE PLACED IN LAYERS NOT LESS THAN 2" OR GREATER
TYPE I19.0B, AT AN AVERAGE RATE OF 114 LBS. PER SQ. YD. PER 1"
PROP. VAR. DEPTH ASPHALT CONCRETE INTERMEDIATE COURSE,
U
W
EXISTING PAVEMENT.
WEDGING (SEE DETAIL)
Detail Showing Method of Wedging
U "
4
12
MIN.
"
4
12
MIN.
C1 C1
CL
D2
C2
D2
C2
D1E1
C2
E1D1 U
W
ENGINEER
V
A
R.
2:
1
M
A
X
CL
8%VAR. 2:1 TO 6:1
EXIST. GROUND
EXIST. GROUND
T
VAR
. TO
4
:1
NORMAL
VAR. 2:1 MAX
8%
VA
R.
2:
1
TO
6:
1
EXIST. GROUND
T
VAR. TO 4:1 NORMAL
VARIES VARIES
D1E1
C1
-L1- / -L2-
-L1- / -L2-
17BP.8.R.61/17BP.8.R.60
AS DIRECTED BY ENGINEER
MILL 25’ TO 50’
V
1.25"
C1
U
MILLING DETAIL
-L2- 13+80.00
V 1.25" MILLING.
-L2-
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
PAVE SHOULDER TO FACE OF GUARDRAIL
ADD 3’ TO SHOULDERS FOR GUARDRAIL*
*PAVE SHOULDER TO FACE OF GUARDRAIL
ADD 3’ TO SHOULDERS FOR GUARDRAIL
-L2- STA. 12+75.00 TO -L2- STA. 13+80.00
-L1- STA. 11+75.00 TO -L1- STA. 12+75.00
-L1- STA. 12+75.00 TO -L1- STA. 14+65.00
-L1- STA. 10+80.00 TO -L1- STA. 11+75.00
-L2- STA. 12+25.00 TO -L2- STA. 12+75.00
MIN.
8’ -0"11’11’
GRADE
POINT
GRADE TO THIS LINE
MIN.
8’ -0"
GRADE TO THIS LINE
10 1/2"
MIN.
8’ -0"
GRADE
POINT
11’11’
MIN.
8’ -0"
EXIST. GROUND
10 1/2"
4’4’**
4’*4’*
-L2- STA. 11+35.00 TO -L2- STA. 12+25.00
CO
M
P
U
T
E
D
B
Y
:
A
M
H
DA
T
E
:
SHEET NO.
CH
E
C
K
E
D
B
Y
:
DA
T
E
:
3-A
ZL0005CAR1US
SF-750439 & SF-750440
5/
2
9
/
2
0
1
4
LI
S
T
O
F
P
I
P
E
S
,
E
N
D
W
A
L
L
S
,
E
T
C
.
(
F
O
R
P
I
P
E
S
4
8
I
N
C
H
E
S
&
U
N
D
E
R
)
R
.
C
.
P
I
P
E
C
L
A
S
S
I
V
PROJECT NO.
***" RC PIPE CULVERTS, CONTRACTOR DESIGN
G.D.I. FRAME WITH GRATE STD. 840.20
FR
A
M
E
,
GR
A
T
E
S
,
AN
D
H
O
O
D
ST
A
N
D
A
R
D
84
0
.
0
3
CONCRETE TRANSITIONAL SECTION G.D.I. TYPE "A" STD. 840.17 OR 840.26 G.D.I. TYPE "B" STD. 840.18 OR 840.27 G.D.I. TYPE "D" STD. 840.19 OR 840.28
** " R.C. PIPE (CLASS V)
G.D.I. FRAME WITH TWO GRATES STD. 840.22
C.B. STD. 840.01 OR STD. 840.02
EN
D
W
A
L
L
S
D.I. STD. 840.14 OR STD. 840.15 D.I. FRAME AND GRATE STD. 840.16
R
.
C
.
P
I
P
E
C
L
A
S
S
I
I
I
C
.
S
.
P
I
P
E
***" RC PIPE CULVERTS, CONTRACTOR DESIGN
15" SIDE DRAIN PIPE
18" SIDE DRAIN PIPE
SLOPE CRITICAL
ST
A
T
I
O
N
STRUCTURE NO.
D
R
A
I
N
A
G
E
P
I
P
E
(R
C
P
,
C
S
P
,
C
A
A
P
,
H
D
P
E
,
o
r
P
V
C
)
LOCATION (LT, RT, OR CL)'
DRAINAGE PIPE ELBOWS NO. & SIZE CONC. COLLARS CL. "B" C.Y. STD. 840.72 PIPE REMOVAL LIN. FT.CONC. & BRICK PIPE PLUG, C.Y. STD. 840.71 J.B. STD. 840.31 OR 840.32
NO
R
T
H
C
A
R
O
L
I
N
A
D
E
P
A
R
T
M
E
N
T
O
F
T
R
A
N
S
P
O
R
T
A
T
I
O
N
DI
V
I
S
I
O
N
O
F
H
I
G
H
W
A
Y
S
TOP ELEVATION
INVERT ELEVATION
INVERT ELEVATION
QUANTITIES
FOR DRAINAGE
STRUCTURES
*TOTAL L.F. FOR PAY
QUANTITY SHALL BE COL.
'A' + (1.3 X COL.'B')
G.D.I. (N.S.) FRAME WITH GRATE STD. 840.24 G.D.I. (N.S.) FRAME WITH TWO GRATES STD. 840.24ABBREVIATIONS
SI
Z
E
TH
I
C
K
N
E
S
S
OR
G
A
U
G
E
%
E
F
G
13
+
5
6
-
L
1
-
R
T
4
0
1
o
u
t
5
9
5
.
3
2
5
9
2
.
7
0
6
.
5
5
4
0
11
+
1
3
-
L
2
-
L
T
5
0
1
o
u
t
6
2
3
.
5
9
6
2
2
.
0
0
5
.
6
8
2
8
20
14
+
2
2
-
L
2
-
L
T
5
0
2
o
u
t
6
2
4
.
5
3
6
2
2
.
4
0
5
.
3
2
4
0
21
SH
E
E
T
T
O
T
A
L
S
10
8
41
12
'
'
1
5
'
'
24
'
'
3
0
'
'
18
'
'
2
4
'
'
15
'
'
1
8
'
'
12
'
'
30
'
'
R
.
C
.
P
I
P
E
C
L
A
S
S
I
V
42
'
'
***" RC PIPE CULVERTS, CONTRACTOR DESIGN
LI
N
.
FT
.
PER EACH (0' THRU 5.0')
G.D.I. FRAME WITH GRATE STD. 840.20
.064
.064
.079
.109
FR
A
M
E
,
GR
A
T
E
S
,
AN
D
H
O
O
D
ST
A
N
D
A
R
D
84
0
.
0
3
CONCRETE TRANSITIONAL SECTION DROP INLET CATCH BASIN G.D.I. TYPE "A" STD. 840.17 OR 840.26 G.D.I. TYPE "B" STD. 840.18 OR 840.27 G.D.I. TYPE "D" STD. 840.19 OR 840.28
** " R.C. PIPE (CLASS V)
42
'
'
4
8
'
'
G.D.I. FRAME WITH TWO GRATES STD. 840.22
C.B. STD. 840.01 OR STD. 840.02
TY
P
E
O
F
GR
A
T
E
EN
D
W
A
L
L
S
D.I. STD. 840.14 OR STD. 840.15 D.I. FRAME AND GRATE STD. 840.16
R
.
C
.
P
I
P
E
C
L
A
S
S
I
I
I
48
'
'
C
.
S
.
P
I
P
E
.064
36
'
'
***" RC PIPE CULVERTS, CONTRACTOR DESIGN
15" SIDE DRAIN PIPE
10.0' AND ABOVE
ST
D
.
8
3
8
.
0
1
83
8
.
1
1
O
R
ST
D
.
8
3
8
.
8
0
(U
N
L
E
S
S
NO
T
E
D
OT
H
E
R
W
I
S
E
)
B
CU
.
Y
A
R
D
S
18" SIDE DRAIN PIPE
DO NOT USE HDPE
36
'
'
.109
SLOPE CRITICAL
30
'
'
3
6
'
'
18
'
'
ST
A
T
I
O
N
STRUCTURE NO.
D
R
A
I
N
A
G
E
P
I
P
E
(R
C
P
,
C
S
P
,
C
A
A
P
,
H
D
P
E
,
o
r
P
V
C
)
DO NOT USE RCP
DO NOT USE CSP
DO NOT USE CAAP
FROM
TO
LOCATION (LT, RT, OR CL)'
5.0' THRU 10.0'
.064
.079
Remove Existing 15" RCP Remove Existing 15" RCP DRAINAGE PIPE ELBOWS NO. & SIZE REMARKSCONC. COLLARS CL. "B" C.Y. STD. 840.72 PIPE REMOVAL LIN. FT.CONC. & BRICK PIPE PLUG, C.Y. STD. 840.71 Drive PipeC.B.N.D.I.D.I.G.D.I.G.D.I.(N.S.)J.B.M.H.T.B.D.I.T.B.J.B.CATCH BASIN NARROW DROP INLET DROP INLET GRATED DROP INLET (NARROW SLOT)JUNCTION BOX MANHOLE TRAFFIC BEARING DROP INLET TRAFFIC BEARING JUNCTION BOX J.B. STD. 840.31 OR 840.32
12
'
'
2
4
'
'
15
'
'
4
2
'
'
4
8
'
'
TOP ELEVATION
INVERT ELEVATION
INVERT ELEVATION
A
QUANTITIES
FOR DRAINAGE
STRUCTURES
*TOTAL L.F. FOR PAY
QUANTITY SHALL BE COL.
'A' + (1.3 X COL.'B')
G.D.I. (N.S.) FRAME WITH GRATE STD. 840.24 G.D.I. (N.S.) FRAME WITH TWO GRATES STD. 840.24ABBREVIATIONS
18
'
'
15
'
'
12
'
'
4
8
'
'
42
'
'
36
'
'
30
'
'
24
'
'
No
t
e
:
I
n
v
e
r
t
E
l
e
v
a
t
i
o
n
s
i
n
d
i
c
a
t
e
d
a
r
e
f
o
r
B
i
d
P
u
r
p
os
e
s
o
n
l
y
a
n
d
s
h
a
l
l
n
o
t
b
e
u
s
e
d
f
o
r
p
r
o
j
e
c
t
c
o
n
s
t
r
u
ct
i
o
n
s
t
a
k
e
o
u
t
.
Se
e
"
S
t
a
n
d
a
r
d
S
p
e
c
i
f
i
c
a
t
i
o
n
s
F
o
r
R
o
a
d
s
a
n
d
S
t
r
u
c
t
u
r
es
,
S
e
c
t
i
o
n
3
0
0
-
5
"
.
GUARDRAIL SUMMARY
LINE
SURVEY
STATION
END LOCATION
STRAIGHT
CURVED
SHOP
FACED
DOUBLE
END
APPROACH
END
TRAILING
E.O.L.
FROM
DIST.
"N"
WIDTH
SHOULDER
TOTAL
END
APPROACH
END
TRAILING
END
APPROACH
END
TRAILING
FLARE LENGTH WWARRENT POINTLENGTH ANCHORS
AT-1
REMARKS
STATION
BEGINNING
TYPE III
DIVISION OF HIGHWAYS
STATE OF NORTH CAROLINA
TOTAL
LESS ANCHOR DEDUCTIONS
SAY
ADDITIONAL GUARDRAIL POSTS - 5 EA
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
R/W SHEET NO.
5
/
1
4
/
9
9 SHEET NO.PROJECT REFERENCE NO.
RT
2
2
2
TOTAL
LESS ANCHOR DEDUCTIONS
SAY
ADDITIONAL GUARDRAIL POSTS - 5 EA
SUBTOTAL
"N" = DISTANCE FROM EDGE OF LANE TO FACE OF GUARDRAIL.
TOTAL SHOULDER WIDTH = DISTANCE FROM EDGE OF TRAVEL LANE TO SHOULDER BREAK POINT.
FLARE LENGTH = DISTANCE FROM LAST SECTION OF PARALLEL GUARDRAIL TO END OF GUARDRAIL.
W = TOTAL WIDTH OF FLARE FROM BEGINNING OF TAPER TO END OF GUARDRAIL.
G = GATING IMPACT ATTENUATOR TYPE 350
NG = NON-GATING IMPACT ATTENUATOR TYPE 350
3-B
LT
13+45.0011+70.00
13+84.512+22.00
11+76.00 13+38.50
13+38.50 11+76.00
8
400.00’
0.00’
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
3’-0"
3’-0"
4’-0"
4’-0"
6’-0"
6’-0"
7’-0"
7’-0"
-L1-
-L1-
-L2-
-L2-
LT
RT
2
100.00’
100.00’
100.00’
GRAU-350 8 @ 50’ =
GRAU-350
17BP.8.R.61
17BP.8.R.60 &
100.00’75.00’
62.50’
62.50’
62.50’
262.50’
-400.00’
262.50’
262.50’
11+70.00 13+45.00
12+22.00 13+84.5
11+76.00 13+38.50
11+76.0013+38.50
SUMMARY OF EARTHWORK
IN CUBIC YARDS
NOTE:
SAY
LOSS DUE TO CLEAR & GRUB.
UNDERCUTLOCATION WASTEBORROWEMBT+%EXCAVATION
UNCLASSIFIED
WASTE IN LEU OF BORROW
paid for at the contract lump sum price for "Grading."
Clearing and Grubbing, and Removal of Existing Pavement will be
Approximate quantities only. Unclassified Excavation, Fine Grading,
SUBTOTAL
PROJECT TOTAL
TOTAL
EST. 5% TO REPLACE TOP SOIL ON BORROW PIT
GRAND TOTAL
34
342
342
443
443
443
450
-L1- STA. 10+80.00 TO 14+65.00 558
558
-L2- STA. 11+35.00 TO 13+80.00 101 570
570101SUBTOTAL
469
469
216
216
1,128 685
6851,128
1,128 719
D
T
1
5
8
D
T
1
5
9
D
T
1
6
1
D
T
1
6
4
D
T
1
6
8
D
T
1
6
9
D
T
1
7
1
WOODS
EXI
STI
N
G
R/
W
6
0
.0
0
’
EXI
STI
N
G
R/
W
D
T
3
3
7
WOODS
FIELD
PASTURE
GRASS
GRASS
DB 2096 PG 455
GARRISON COLTRANE
CRYSTAL N.
DB 1196 PG 1833
L.K. ROUTH JR.
DB 1844 PG 777
ANTHONY NEIL GARRISON
DB 1083 PG 797
ROGER DERYL GARRISON
PB 89 PG 25
DB 1866 PG 3003
ROGER DERYL GARRISON
PB 126 PG 89
DB 2200 PG 696
VIVIAN PARRIS WHITE
DB 2163 PG 883
CHRISTINE PARRIS
20’ PAVED ROADWAY
SR 2261 OLD LIBERTY RD.
T
O
N
C
H
WY 22
TO US HWY 421GRASS
EIR
EIR
EIR
EIP
EIP
PAVED
DRIVE
SOIL & GRAVEL
T
T
T
EOI
EOI
PI Sta 12+73.72
D
L = 411.99’
T = 226.37’
R = 400.00’
10
15
D
PI Sta 14+94.75
L = 70.74’
T = 35.41’
R = 620.00’
PI Sta 10+23.70
D
L = 47.35’
T = 23.70’
R = 385.00’
-L1-
PT Sta. 15+30.08
PCC Sta. 14+59.34
PC Sta. 10+00.00
PCC Sta. 10+47.35
0
3
0
8
0
8
0
0
E
XIS
T.
0
4
0
5
0
6
0
8
0
8
0
7 0
6 0
5
0
3 0
2
0
1
E
XI
S
T.
D.S.= 30mph D.S.= 30mph D.S.= 35mph
0
7 0
8
0
8
0
4
15"0401
2:
1
D Flatter4:1 or
d
( Not to Scale)
SPECIAL CUT DITCH
FROM STA. 14+50 TO STA. 15+25 -L1- RT
FROM STA. 11+50 TO STA. 12+00 -L1- LT
FROM STA. 10+25 TO STA. 11+00 -L1- LT
Slope
Ditch
Front
Ground
Natural
DETAIL A-1
Type of Liner= PSRM Max d=1.5 Ft.
Min. D=1.0 Ft.
FROM STA. 14+00 TO STA. 14+50 -L1- RT
FROM STA. 11+00 TO STA. 11+50 -L1- LT
DETAIL B-1
Max. d=1.5 Ft.
Min. D=1.0 Ft.
Type of Liner= PSRM
Ground
Natural Slope
Ditch
Front
2:
1
D Flatter4:1 or
d
( Not to Scale)
CUT DITCH
2:
1
D Flatter2:1 or
d
( Not to Scale)
SPECIAL CUT DITCH
FROM STA. 12+95 TO STA. 14+00 -L1- RT
FROM STA. 13+45 TO STA. 14+65 -L1- LT
FROM STA. 12+00 TO STA. 12+95 -L1- LT
DETAIL C-1
Max. d=1.5 Ft.
Min. D=1.0 Ft.
Type of Liner= CL I Rip-Rap
Slope
Ditch
Front
Ground
Natural
Geotextile
SEE DETAIL A-1
LINE W/ PSRM
SPECIAL CUT ’V’ DITCH
SEE DETAIL B-1
LINE W/ PSRM
CUT ’V’ DITCH
SEE DETAIL A-1
LINE W/ PSRM
SPECIAL CUT ’V’ DITCH
SEE DETAIL C-1
LINE W/ CLASS I
SPECIAL CUT ’V’ DITCH
SEE DETAIL C-1
LINE W/ CLASS I
SPECIAL CUT ’V’ DITCH
SEE DETAIL A-1
LINE W/ PSRM
SPECIAL CUT ’V’ DITCH
SEE DETAIL B-1
LINE W/ PSRM
CUT DITCH
SEE DETAIL C-1
LINE W/ CLASS I
SPECIAL CUT ’V’ DITCH
1
2
3
4
5
6
7
30.05’
41.54’
42.35’
30.03’
42.09’
39.15’
29.70’
37.08’
35.59’
+50.92
+00.82
+91.37
+07.48
+48.60
+61.39
+99.69
40.00’
30.00’
45.00’
45.00’
31.98’
+85.24
+59.34
40.00’
29.31’
40.00’
27.60’
45.00’
30.69’
31.44’
+50.00
+10.00
+80.00
+50.00
+46.41
51.29’
+62.05
41.32’
+15.93
60.00’
+36.84
31.61’
+63.99
29.95’
+22.80
40.90’
+35.55
63.84’
+49.30
76.57’+73.64
71.13’
+50.00
60.00’
35.00’
R
E
V
IS
I
O
N
S
HYDRAULICSROADWAY DESIGN
ENGINEER ENGINEER
R/W SHEET NO.
SHEET NO.PROJECT REFERENCE NO.
417BP.8.R.61
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
1
7
/
9
9
N
C
G
RI
D
N
A
D
8
3
N
A
2
0
1
1
11’
11’
1
1’
1
1’
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
NOTE: SEE PLAN SHEET 6 FOR PROFILE
LINE (TYP)
SLOPE STAKE
CREEK
BRANCH SANDY
-L1- STA. 10+80.00
BEGIN PROJECT 17BP.8.R.61
-L1- STA. 14+65.00
END PROJECT 17BP.8.R.61
+
0
0
(
TYP)
2
0’
GRAU 350
GR
AU
3
5
0
GRAU 350
GRAU 350
+
8
0
(TYP)
20’
2
2
’
BRIDGE 439
2 @ 10’ X 10’ RCBC
-L1- STA. 12+97
NOTE: SEE SHEETS C-1 THRU C-12 FOR STRUCTURE PLANS
4’ PS
4
’ P
S 10:1
10:1
10:
1
10
:1
F
F
F
F
C
C
C
C
C
C
C
C
C
WOODS
EXI
S
TI
NG
R/
W
6
0
.0
0
’
EXI
S
TI
NG
R/
W
WOODS
WOODS
WOODS
S
O
I
L
&
G
R
A
V
E
L
SO IL & G R A V EL
GRASS
PASTURE
PASTURE
WOODS &
TO NC HWY 22
S
R
2261
OL
D
LI
B
E
R
T
Y
R
D.
2
0’
P
AVE
D
R
OAD
W
AY
T
O
US
H
WY 421
AXLE
N
8
8
3
3’
1
9
"
W
2
0
3.
9
6’
N
5
0
4
5
’3
7
" W
14
1.0
3
’
N
3121’37" W
375.89’
S
5
4
0
8’
2
6"
W
4
1
3.
8
3’
N
8
8
0
6’
5
6
"
W
8
0.
0
4’
N
8
7
4
5’
4
7
"
W
1
6
5.
2
6
’
N
8
8
0
8’
2
9
"
W
1
3
1.
2
3’
N
8
9
0
9’
4
4
"
W
2
4
3.
8
1’
N 0732’23" E
235.18’
EIP
EIR
STONE
EIR
BILLY RAY SHEFFIELD
DB 1158 PG 313
PB 20 PG 25
DB 1808 PG 2953
GEORGE W. SHELAR
DB 1073 PG 817
CATHERINE R. WARD
BICKETT A. &
PASTURE
WOODS &
JAYNE R. BLEVINS
DB 99E PG 64
WOODS
T
T
REMOVE15"
REM
O
VE
EST. 50 TONS
CLASS ’II’ RIP RAP
EST. 24 C.Y.
EXCAVATION
BENCH
FLOODPLAIN
BENCH
FLOODPLAIN
0501
0502
15"
EST. 10 TONS
CLASS ’II’ RIP RAP
EST. 15 SY
COIR FIBER MATTING
EST. 10 TONS
CLASS ’II’ RIP RAP
EST. 10 SY
COIR FIBER MATTING
EST. 45 TONS
CLASS ’II’ RIP RAP
EST. 26 C.Y.
EXCAVATION
EST. 10 TONS
CLASS ’II’ RIP RAP
d
2:
1
B
D
( Not to Scale)
SPECIAL CUT BASE DITCH
Flatter2:1 or
FROM STA. 11+00 TO STA. 12+20 -L2- LT
DETAIL A-2
B=2.0 Ft.
Max. d=1.5 Ft.
Min. D=1.0 Ft.
Type of Liner= PSRM
Ground
Natural
Slope
Ditch
Front
d
2:
1
B
D
( Not to Scale)
SPECIAL CUT BASE DITCH
Flatter2:1 or
FROM STA. 12+65 TO STA. 13+75 -L2- LT
DETAIL B-2
B=2.0 Ft.
Max. d=1.5 Ft.
Min. D=1.0 Ft.
Type of Liner= CL I Rip-Rap
Ground
Natural
Ditch
Slope
Front
Geotextile
d
2:
1
B
D
( Not to Scale)
SPECIAL CUT BASE DITCH
Flatter2:1 or
FROM STA. 13+75 TO STA. 14+50 -L2- LT
DETAIL C-2
B=2.0 Ft.
Max. d=1.5 Ft.
Min. D=1.0 Ft.
Type of Liner= PSRM
Ground
Natural
Slope
Ditch
Front
SEE DETAIL A-2
LINE W/ PSRM
SPECIAL CUT BASE DITCH
SEE DETAIL B-2
LINE W/ CLASS I
SPECIAL CUT BASE DITCH
SEE DETAIL C-2
LINE W/ PSRM
SPECIAL CUT BASE DITCH
EST. 126 C.Y.
EXCAVATION
EST 20 SY
COIR FIBER MATTING
EST. 45 TONS
CLASS ’II’ RIP RAP
EST 30 SY
COIR FIBER MATTING
EST. 66 TONS
CLASS ’II’ RIP RAP
BENCH
FLOODPLAIN
EST. 10 TONS
CLASS ’II’ RIP RAP
2A
3A
40.46’
30.22’
39.72’
40.97’
30.00’
+21.00
+30.54
+04.88
+51.83
30.61’
50.07’
29.89’
+69.92
+31.69
+19.36
45.00’
45.00’
45.00’
45.00’
+90.00
+15.00
+70.00
29.75’
30.03’
29.55’
30.37’
+15.00
60.00’+70.00
51.61’
+60.00
53.00’
+27.05
38.23’+62.43
53.00
+86.55
66.93’
+30.83
70.66’
60.00’
1-A
-L2-
10 15
PI Sta 10+95.89
D
L = 188.39’
T = 95.89’
R = 410.00’
PI Sta 12+53.87
D
L = 128.80’
T = 65.48’
R = 290.00’
PI Sta 14+12.28
D
L = 186.87’
T = 95.09’
R = 410.00’
DS = 35 mph DS = 30 mph DS = 35 mph
0
8
0
2
E
XI
S
T.
0
3 0
4 0
5 0
6
0
8
0
8
0
8
0
7
0
9
0
6
EXIST.
PT Sta. 15+04.07
PCC Sta. 13+17.20
PCC Sta. 11+88.39
PC Sta. 10+00.00
0
7
0
5
10
N
C
G
RI
D
N
A
D
8
3
N
A
2
0
11
P
R
ONG CR
E
E
K
-L2-
R
E
V
IS
I
O
N
S
HYDRAULICSROADWAY DESIGN
ENGINEER ENGINEER
R/W SHEET NO.
SHEET NO.PROJECT REFERENCE NO.
517BP.8.R.60
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
1
7
/
9
9
NOTE: SEE SHEETS C-1 THRU C-12 FOR STRUCTURE PLANS
NOTE: SEE PLAN SHEET 7 FOR PROFILE
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
11’
11’
LINE (TYP)
SLOPE STAKE
+
5
0
-L2- STA. 11+35.00
BEGIN PROJECT 17BP.8.R.60
-L2- STA. 13+80.00
END PROJECT 17BP.8.R.60
TYP20’
GRAU 350
G
R
AU
3
5
0
GRAU
3
5
0GRAU 350
+
0
0
BRIDGE 440
3 @ 10’ X 8’ RCBC
-L2- STA. 12+34
4’ PS
4’ PS
10:1
10:1
10
:1
1
0:
1
F
F
F C
C
FF
C
C
5
/
1
4
/
9
9 SHEET NO.PROJECT REFERENCE NO.
HYDRAULICSROADWAY DESIGN
ENGINEER ENGINEER
617BP.8.R.61
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
10 11 12 13 14 15
575
579
583
587
591
595
599
603
607
6
0
1.7
9
PI = 12+06.68
EL = 596.41’
(-
)4
.2
4
6
4%(+)0.6427%
VC = 185’
K = 38
PI = 13+83.19
EL = 597.55’
(+)0.6427%(+)4.9315%
VC = 160’
K = 37
6
0
1.5
8
DS = 30 MPH
DS = 30 MPH
(
-
)
6.
4
2
67%
(-
)5.
8
6
0
0%
E
L
E
V
=
5
9
3
.11
P
I
=
12
+
0
0
L
T
(-
)4
.2
13
3%(+)7.0100%
(+)2.2800%
E
L
E
V
=
5
8
9
.6
1
P
I
=
13
+
7
5
L
T
(+)7.0600%
E
L
E
V
=
5
9
3
.14
P
I
=
14
+
2
5
L
T
(+)9.0250%
(+)6.0533%
E
L
E
V
=
6
0
2
.6
4
P
I
=
10
+
2
5
L
T
B
E
G
I
N
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
5
9
7
.8
2
P
I
=
11+
0
0
L
T
E
N
D
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
5
9
6
.0
4
P
I
=
11+
5
0
L
T
B
E
G
I
N
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
5
8
9
.11
P
I
=
12
+
9
5
L
T
E
N
D
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
5
8
9
.7
1
P
I
=
12
+
9
5
R
T
B
E
G
I
N
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
5
9
7
.0
7
P
I
=
14
+
0
0
R
T
E
N
D
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
5
8
8
.9
3
P
I
=
13
+
4
5
L
T
B
E
G
I
N
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
5
9
6
.7
5
P
I
=
14
+
6
5
L
T
E
N
D
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
5
9
8
.6
1
P
I
=
14
+
5
0
R
T
B
E
G
I
N
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
6
0
3
.15
P
I
=
15
+
2
5
R
T
E
N
D
D
I
T
C
H
G
R
A
D
E
DESIGN DISCHARGE
DESIGN FREQUENCY
BASE DISCHARGE
CFS
YRS
YRS
BASE FREQUENCY
OVERTOPPING ELEVATION
OVERTOPPING FREQUENCY
OVERTOPPING DISCHARGE CFS
CFS
YRS
FT
FT
FT
DESIGN HW ELEVATION
BASE HW ELEVATION
CULVERT HYDRAULIC DATA
= 500
= 25
= 590.1
= 750
= 100
= 591.07
= 2,400
= 500+
= 598.0
NOTE: SEE SHEETS C-1 THRU C-12 FOR STRUCTURE PLANS
NOTE: SEE PLAN SHEET 4 FOR PLAN
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
OFF 53.20’ RT
Sta. 14+06.39
-L1-
OF 24" POPLAR
RR SPIKE IN BASE
ELEV. 603.38’
OFF 63’ RT
Sta. -BL- 9+01.00
BM 1
-L1- STA. 10+80.00
BEGIN GRADE
-L1- STA. 14+65.00
END GRADE
-L1- (BR 439)
5
/
1
4
/
9
9 SHEET NO.PROJECT REFERENCE NO.
HYDRAULICSROADWAY DESIGN
ENGINEER ENGINEER
717BP.8.R.60
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
10 11 12 13 14 15
600
604
608
612
616
620
624
628
632
PI = 12+53.70
VC = 75’
EL = 624.82’
K = 121
DS = 55 MPH
(+)0.5972%(-)0.0218%6
2
4
.11
6
2
4
.7
9
E
L
E
V
=
6
2
2
.0
0
P
I
=
11+
2
5
L
T
(
-
)
5.
40
0
0%
(-
)6.
3
6
0
0%
(-
)4
.3
3
3
3%
E
L
E
V
=
6
19
.0
0
P
I
=
11+
7
5
L
T
(+)1.6286%
E
L
E
V
=
6
17
.0
7
P
I
=
13
+
0
0
L
T
(+)2.4200%(+)10.0000%
E
L
E
V
=
6
18
.2
8
P
I
=
13
+
5
0
L
T
E
L
E
V
=
6
2
0
.7
8
P
I
=
13
+
7
5
L
T
(+)5.7200%
E
L
E
V
=
6
2
3
.5
9
P
I
=
11+
0
0
L
T
B
E
G
I
N
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
6
17
.0
5
P
I
=
12
+
2
0
L
T
E
N
D
D
I
T
C
H
G
R
A
D
E
E
L
E
V
=
6
16
.5
0
P
I
=
12
+
6
5
L
T
B
E
G
I
N
D
I
T
C
H
G
R
A
D
E E
L
E
V
=
6
2
5
.0
7
P
I
=
14
+
5
0
L
T
E
N
D
D
I
T
C
H
G
R
A
D
E
DESIGN DISCHARGE
DESIGN FREQUENCY
BASE DISCHARGE
CFS
YRS
YRS
BASE FREQUENCY
OVERTOPPING ELEVATION
OVERTOPPING FREQUENCY
OVERTOPPING DISCHARGE CFS
CFS
YRS
FT
FT
FT
DESIGN HW ELEVATION
BASE HW ELEVATION
CULVERT HYDRAULIC DATA
= 500
= 25
= 618.0
= 800
= 100
= 618.84
= 2,350
= 500+
= 624.4 OFF 59.47’ RT
Sta. 11+38.45
-L2-
OF 15" POPLAR
RR SPIKE IN BASE
ELEV. 617.64’
OFF 43’ RT
Sta. -BL- 6+51.00
BM 1
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
NOTE: SEE SHEETS C-1 THRU C-12 FOR STRUCTURE PLANS
NOTE: SEE PLAN SHEET 5 FOR PLAN
-L2- STA. 11+35.00
BEGIN GRADE
-L2- STA. 13+80.00
END GRADE
-L2- (BR 440)
SHEET NO.PROJECT REFERENCE NO.
X-1
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
1
7
/
9
9
CROSS SECTION INDEX
X-1 CROSS SECTION INDEX
17BP.8.R.60/17BP.8.R.61
-L1- (BR 439)X-2 THRU X-8
-L2- (BR 440)X-9 THRU X-13
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
595 595
600 600
605 605
610 610
615 615
590 590
10+50.00
595 595
600 600
605 605
610 610
590 590
10+75.00
595 595
600 600
605 605
610 610
590 590
10+80.00
X-217BP.8.R.61
-L1-
2.5 5
License: C-2197
Fax:919-789-9591
Tel:919-789-9977
Raleigh, NC 27605
1025 Wade Avenue
C O N S T R U C T I O N
E N G I N E E R I N G &
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
602.97
2:
1 4:1
601.992:
1
4:1
0.074 0.022 4
:
1
601.792:
1
599.11
4:1
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
595 595
600 600
605 605
610 610
590 590
11+00.00
595 595
600 600
605 605
610 610
590 590
11+25.00
595 595
600 600
605 605
590 59011+50.00
X-317BP.8.R.61
-L1-
2.5 5
0.080 0.030
597.82
4:1
2:
1
4
:
1
600.99
0.080 0.043
596.78
4:12:
1
2:
1
599.99
0.080 0.055
596.04
4:12:
1
2:
1
599.07
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
590 590
595 595
600 600
605 605
585 585
11+75.00
590 590
595 595
600 600
605 605
585 58512+00.00
590 590
595 595
600 600
605 605
585 58512+25.00
X-417BP.8.R.61
-L1-
2.5 5
0.080 0.068
4:1 2:
1
598.10
2:
1 594.58
0.080 0.0804:1
2:
1597.322:
1
593.11
0.080 0.080
2:1 2:
1596.63
2:
1 592.06
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
590 590
595 595
600 600
605 605
585 58512+50.00
585 585
590 590
595 595
600 600
605 605
580 580
12+75.00
585 585
590 590
595 595
600 600
605 605
580 580
13+00.00
X-517BP.8.R.61
-L1-
2.5 5
0.080 0.080
2:1
2:
1596.21
2:
1 591.00
0.080 0.080
2:1
596.00
2:
1 589.95
0.080 0.070
2:
1
585.42
590.06
2:1
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
585 585
590 590
595 595
600 600
605 605
580 58013+25.00
590 590
595 595
600 600
605 605
585 58513+50.00
590 590
595 595
600 600
605 605
585 58513+75.00
X-617BP.8.R.61
-L1-
2.5 5
0.080 0.057
2:1 2:
1
596.12 2:1
591.81
0.080 0.045
2:1 596.87
2:
1
589.04
4
:
1
593.57
2:1
0.080 0.032
2:1 597.91
2:
1
589.61
DRIVEWAY
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
590 590
595 595
600 600
605 605
610 610
585 585
14+00.00
595 595
600 600
605 605
610 610
590 59014+25.00
595 595
600 600
605 605
610 610
615 615
590 590
14+50.00
X-717BP.8.R.61
-L1-
2.5 5
0.080 0.020
597.07
4
:
1
2:1
598.89
2:
1
2:1
592.38
0.080 0.008
597.73
4
:
1 2:1
599.91
4:1
2:
1
593.14
0.075 0.005
598.61
4
:
1
2:1
600.94
1"/ FT 2:
1
595.40
4:1
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
595 595
600 600
605 605
610 610
590 590
14+65.00
595 595
600 600
605 605
610 610
590 590
14+75.00
595 595
600 600
605 605
610 610
615 615
590 590
15+00.00
X-817BP.8.R.61
-L1-
2.5 5
0.064 0.013
4
:
14:1
601.58
599.52
2:1
602.00
4
:
1
600.12
2:1
603.00
4
:
1
2:1
601.64
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
620 620
625 625
630 630
615 615
11+25.00
615 615
620 620
625 625
630 630
610 610
11+35.00
615 615
620 620
625 625
630 630
610 610
11+50.00
X-917BP.8.R.60
-L2-
2.5 5
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
624.10
2:
1
3:1
622.00
624.11
0.010 0.080
2:
1
624.11
2:
1
3:1
621.40
624.14
0.017 0.080
2:
1
624.14
2:
1
3:1
620.50
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
615 615
620 620
625 625
630 630
610 610
11+75.00
615 615
620 620
625 625
630 630
610 610
12+00.00
615 615
620 620
625 625
630 630
610 610
12+25.00
X-1017BP.8.R.60
-L2-
2.5 5
624.13
0.030 0.0802:1
2:
1
624.13
2:
1
619.00
624.19
0.042 0.080
2:
1
624.19
2:
1
617.92
2.1:1
624.32
0.055 0.080
624.322.1:1
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
615 615
620 620
625 625
630 630
610 61012+50.00
615 615
620 620
625 625
630 630
610 610
12+75.00
615 615
620 620
625 625
630 630
610 610
13+00.00
X-1117BP.8.R.60
-L2-
2.5 5
612.83
0.068
0.080
612.83
624.18
0.080
0.080
2:
1
624.18
2:
1
616.66
2.1:1
624.28
0.080
0.080
2:
1
624.28
2:
1 617.07
2.1:1
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
615 615
620 620
625 625
630 630
610 610
13+25.00
615 615
620 620
625 625
630 630
610 610
13+50.00
620 620
625 625
630 630
615 61513+75.00
X-1217BP.8.R.60
-L2-
2.5 5
624.47
0.068
0.0822:1
2:
1
624.47
2:
1
617.68
624.54
0.055 0.0952:1
2:
1
624.54
2:
1
618.28
624.76
0.043 0.107
3:1 2:
1
624.76
2:
1
620.78
00
00
55
55
1010
1010
1515
1515
2020
2020
2525
2525
3030
3030
3535
3535
4040
4040
4545
4545
5050
5050
5555
5555
6060
6060
6565
6565
7070
7070
7575
7575
$
$
$
$
$
$
S
Y
S
T
IM
E
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
D
G
N
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
U
S
E
R
N
A
M
E
$
$
$
$
8
/
2
3
/
9
9
PROJ. REFERENCE NO.SHEET NO.0
620 620
625 625
630 630
615 61513+80.00
620 620
625 625
630 630
615 615
14+00.00
X-1317BP.8.R.60
-L2-
2.5 5
624.79
0.040 0.110
2:
1
624.79
2:
1
621.07
3:1
625.013:1
622.21
2:
1
North Carokna Le 2a i" e E
'elcCro;y
Mr. Art King
NCDOT Division 8 Environmental Officer
North Carolina Department of Transportation
902 N. Sandhills Boulevard
Aberdeen. North Carolina 28315
Dear Mr. King:
-f Vfr0i11'i;£"1t i lid Nal'.;..irli SesaircCS
. C.'
September 30, 2014
I0
Subject: SEEP Mitigation Acceptance Letter:
1)i ision 8 Project. Replace Bridge 440 on SR 2261 over. Prom! Creek, Randolph County
The purpose of this letter is to notify you that the Ecosystem Enhancement Program (F EP) will provide the
compensatory stream mitigation Ibr the subject project. Based on the infomuation supplied by you on September 30.
2014, the impacts are located in CU 03030003 of the Cape Fear Rivet basin in the Central Piedmont (CP) Eco-Region.
and are as follows.
Crape Fear
03030003
CP
Stream
Cold Cool r Warm
Impacts (feet/acres) 1 0
Wetlands
Non- 1 Coastal
Etipaii`irt Riparian llatsli
O 1 98.0 0 f) 0
Buffer (Sq. Et )
Zone 1 Zone 2
0
0
*Some of the stream and vetiand inipaets may be proposed to be mitigated at :i 1.1 mitigation ratio. Sec permit application for
details
This impact and associated mitigation need were under projected by the NCDOT in the 2014 impact data. PEP
will commit to implement sufficient compensator stream mitigation credits to offset the ampacts associated with this
project as determined by die regulatory agencies using the delivery timeline listed in Section 1 3.c.iit of the N.C.
Department of Environment and Natural Resources' Ecosystem Enhancement Program In -Lieu Fee Instrument dated
July 28, 2010. lithe above referenced impact aniotints ate revised, then this mitigation acceptance letter will no longer
be valid and a new m tication acceptance letter will be required from LEP_ -
If you have any questions or need additional information, please eontact Beds l larmcin at 919-707-8420.
Sincerely,
Jai 13. Stanfill
EEP Asset Management Supervisor
cc. Ms. Er/ Ilan•, USACE Wilmington Regulatory Field Office
Dawe 11'amwnuht NCD\VR Raleigh Office
Ms. Linda Fitzpatrick, NCI)O]' PDEA
Mr. Philip Beach, SEPI Engineering
File. SR �261 —Bridge 440— Division 8
h
Statement of Compliance with Session Law 2009-337 An 'Act to Promote
the Use of Compensatory Mitigation Banks and SL 2011-343.
(link to SL 2009-337) (link to SL 2011-343j
Prior to accessing the Ecosystem Enhancement Program (EEP) In -Lieu Fee Mitigation
Program, all applicants requesting wetlands, stream and/or riparian buffer mitigation are now
required by law to comply with Session Law 2009-337 An Act to Promote the Use of
Compensatory Mitigation Banks and Session Law 2011-343. All requests submitted on or
after June 27, 2011 MUST include this form signed and dated by the permit applicant or an
authorized agent. Please refer to DENR's Implementation Policy for more detailed guidance.
Compliance Statement:
I have read and understand SL-2009-337 and SL-2011-343 and have, to the best of my
knowledge, complied with their requirements. I understand that participation in the
NCEEP is voluntary and subject to approval by permitting agencies.
Please check all that apply:
El meeting
is a Federal or State Government Entity or a unit of local government
meeting the requirements set forth in G.S. 143-214.11 (as amended by SL 2011-
343) and is not required to purchase credits from a mitigation bank.
❑ There are no listed mitigation banks with the credit type I need located in the
hydrologic unit where this impact will take place (link to DWR list)'
❑ Mitigation bank(s) in the hydrologic unit where the impacts will occur have been
contacted and credits are not currently available.
❑ The DWR or the Corps of Engineers did not approve of the use of a mitigation
bank for the required compensatory mitigation for this project.
❑ This is a renewal request and the permit application is under review. Bank
credits were not available at the time the application was submitted.
Enter date permit application was submitted for review:
Note: It is the applicant's responsibility to document any inquiries made to private mitigation
banks regarding credit availability.
PDB
initial here
I haveread and understand EEP!s refund. policies. -(attached)
Philip
Digitally signed by Philip
DN cn=Philip, o=SEPI Eng sneering, Inc, ou=Beach,
,,,email=pbeach@sepiengmeenng com, c=US
( Date 2014093009.01 46424100'
Signature of Applicant or Agent
September 30, 2014
Date
Bridge 440 Over Prong Creek Along SR 2261
Philip Beach
Printed Name
Randolph County, NC
Project Name Location
NORTH CAROLINA ECOSYSTEM ENHANCEMENT PROGRAM, NCEEP
IN -LIEU FEE REQUEST FORM Revised June 18, 2014
Complete requested information, sign and date, email to kelly.williams a(�.ncdenr.gov Attachments are acceptable for clarification
purposes (location map, address or lat long is required) Information submitted is subject to NC Public Records Law and may be
requested by third parties Review meetings are held on Tuesday afternoons.
CONTACT INFORMATION APPLICANT'S AGENT APPLICANT
1. Business/Company Name
2. Contact Person
3. Street Address or P 0 Box
4. City, State, Zip
5. Telephone Number
6. E-Mail Address
7. Project Name
SEPI Engineering, Inc.
Philip Beach
1025 Wade Ave
Raleigh, NC
919 573 9936
pbeach@sepiengineering.com
NCDOT Division 8
Art King
902 N. Sandhills Blvd PO Box 1067
Aberdeen, NC
910-944-2344
acking@ncdot.gov
PROJECT INFORMATION
Bridge 440 Over Prong Creek Along SR 2261
8. Project Location (nearest town, city)
9. Lat-Long Coordinates or attach a map
10. County
Grays Chapel
Latitude: 35.832412°
Randolph
11. River Basin & Cataloging Unit (8-digit) Cape Fear 03030003
(See Note 1)
12. Project Type **indicate owner type and Owner Type:
write in project type (e.g. school, church, retail,
residential, apartments, road, utilities, military, Project Type:
etc.)**
13. Riparian Wetland Impact (ac.) (e.g., 0.13) ,
14. Non -Riparian Wetland Impact (ac.)
15. Coastal Marsh Impact (ac.)
16. Stream Impact (ft.) (e.g. 1,234)
Warm
17. Riparian Buffer Impact (sq. ft.)
Include subwatershed if Jordan or Falls Lake: Zone 1:
18. Regulatory Agency Staff Contacts
USACE: Ms. Sarah Hair (Liz)
Check ('l) below if this request is for a.
revision to a current acceptance
❑ renewal of an expired acceptance
❑ extension of unexpired acceptance
98
El
Government
Longitude: -79.683239°
❑ Private
(Culvert
0
0
0
Cool
Zone 2:
Cold
NCDWR:
Other: Mr. David Wainwright
By signing.below,;the applicant is confirming:they have
readsand understand- EEP's. refund policy posted,.at
nceep.net and attached to,this
Signature of Applicant or Authorized Agent:
Philip
Digitally spned by Pbdhp
ON cnnPbdhp,o=SEPIEnpineennp, Inc,ounBeach,
mail pbeacnesepienpmeennp corn, c-us
Dale 20140930090115-0WOO
Date: September 30, 2014
Note 1: For help in determining the Cataloging Unit, visitwww.nceep net or contact EEP
Direct questions to Kelly Williams at 919-707-8915 or kellv.williams(a.ncdenr.gov or to EEP's front desk at 919-707-8976
Refund Policy for Fees Paid to EEP's In -Lieu Fee Programs (9/21/2009)
Purpose: The purpose of this policy is to make clear the circumstances and process under which a
permittee can obtain a refund while simultaneously balancing customer service and responsible
business practices. This policy applies to all refund requests made on or after the publication date of
this policy.
1. All refund requests must be made in writing to EEP's In -Lieu Fee Program Coordinator at
kelly.williams(cr�ncdenr.gov.
2. All refund requests are subject to fund availability. EEP does not guarantee fund availability for
any request.
3. The request must either come from the entity that made the payment or from an authorized agent.
Third parties requesting refunds must provide written authorization from the entity that made the
payment specifying the name and address of the authorized refund recipient.
4. Refund requests related to unintended overpayments, typographical errors or incorrect invoices
should be brought the attention of the In -Lieu Fee Program Coordinator as soon as possible. Such
requests are typically approved without delay.
5. Payments made under EEP's incremental payment procedure are not eligible for refunds.
6. Refund requests made within nine months of payment to EEP will only be considered for requests
associated with projects that have been terminated or modified where the permittee's mitigation
requirements have been reduced. Such requests must be accompanied by written verification from the
permitting agency that the project has been cancelled, the permits have been rescinded or have been
modified, or the mitigation requirements have been reduced.
7. Refund requests made more than nine months from the payment date will only be considered for
permits that were terminated or modified to not require any mitigation. Such requests must be
accompanied by written verification from the permitting agency that the project has been cancelled, the
permits have been rescinded and/or mitigation is no longer required.
8. Refund requests not meeting the criteria specified above are not eligible for a refund.
9. Refund requests that meet the criteria above will be elevated to EEP Senior Management for
review. The following considerations apply to all refund requests:
a. availability of funds after consideration of all existing project and regulatory obligations
b. the date the payment was made
c. the likelihood EEP can use the mitigation procured using the payment to meet other
mitigation requirements
10. Once a refund has been approved, the refund recipient must provide a completed W-9 form to
EEP's In -Lieu fee Program Coordinator within two weeks in order to process the refund though the
State Controller's Office.
11. All decisions shall be final.
STATE OF NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION
PAT MCCRORY ANTHONY J. TATA
SECRETARY
GOVERNOR
September 30, 2014
Wilmington Regulatory Field Office
US Army Corps of Engineers
69 Darlington Avenue
Wilmington, North Carolina 28403
Attention: Ms. Sarah Hair (Liz), Project Manager
Subject: Project: 17BP.8.R.60 — Bridge 440 Over Prong Creek Along SR 2261 Old
Liberty Road
Application for Section 404 Nationwide Permit 14 and 401-Water Quality
Certification #3886
Dear Ms. Hair:
The North Carolina Department of Transportation (NCDOT) is scheduled to replace
Bridge No. 440 on Old Liberty Road over Prong Creek in Randolph County, NC. The
bridge is structurally deficient and will be replaced with a triple box culvert at the same
location. An off -site detour is proposed. The associated culvert installation activities will
cause permanent impacts to Prong Creek. Prong Creek is listed by the North Carolina
Division of Water Resources (DWR) as Class 'WS-III' waters. The project was evaluated
by NCDOT for the presence of federally listed Threatened and Endangered Species for
Chatham County, NC as well as State Listed Historic Properties. Upon completion of the
assessment, NCDOT concluded that there will be 'no effect' to federally listed species
and no historic properties are located within the project study area.
Normal flow width, depth and velocity will be maintained throughout the culvert.
Sediment transport will also be maintained during bankfull discharge to provide a stable
stream. Bank stabilization will be required at the inlet / outlet side resulting in bank
stabilization impacts. Standard matting for erosion control and temporary mulching and
seeding will be utilized to stabilize the entire construction area.
The culvert installation will occur in a dry work area. An impervious dike (stone and
fabric, sheet piles or Jersey barriers) will be utilized to isolate the work area and a pump
will discharge water to a stilling basin or silt bag for sediment control. Mitigation for the
unavoidable stream impacts due to the culvert installation and footprint activities are
proposed at a ratio of 2:1 for a total of 196 LF. A preliminary acceptance letter from the
North Carolina Ecosystem Enhancement Program (NCEEP) is attached.
Sincerely,
Art King
Division Environmental Officer