Loading...
HomeMy WebLinkAboutNC0025712_Wasteload Allocation_19830121NPDES DOCUHENT SCANNING COVER SFNEET NPDES Permit: NC0025712 Hookerton WWTP Document Type: Permit Issuance Wasteload Allocation Authorize ion fo Construct (AtC) Permit Modification Complete File - Historical Report Speculative Limits Instream Assessment (67b) Environmental Assessment (EA) Permit History Document Date: January 21, 1983 This document is printed on reuse paper - ignore any content on the rezrerse side NPDES WASTE LOAD ALLOCATION a Facility Name • 70%4/ /G4;'-.7t o /L}(�c/ / v Existing Proposed eU c) ea EE'' cs Reference USGS Quad: Zg t (Please attach) Requester. Regional Office . pi (Guideline limitations, if applicable, are to be listed on the back of this form.) Permit No.: X7eU/S,257/2:- Pipe No.: U0/ Engineer Date Rec. # RL() f - U 5 ' County: Date• Design Capacity (MGD) : U P OC. Industrial (% of Flow) : Domestic (% of Flow) : /OCR Receiving Stream: (15-140t/Av- c&.. class: �:_ SwP Sub -Basin' cis - (-) 4 — b 7 Design Temp : Drainage Area: Avg. Streamflow: 7Q10: Winter 7Q10: 30Q2• a�- Location of D.O.minimum (miles below outfall): Slope. CU Velocity (fps): K1 (base e, per day, 200C): K2 (base e, per day, 20°C): 0 0 4.0 a. CIA Effluent Characteristics Monthly Average Comments 7-55 qe 4// /(0-e, /(?Le s 6 —� Original Allocation Revised Allocation Confirmation Prepared By: ebb Effluent Characteristics Monthly Average Comments Date(s) of Revision(s) (Please attach previous allocation) Reviewed By: Date: Form #001' • WASTE LOAD ALLOCATION AP VAL FO RM Facility Name: l400ker4oy wiAtrP County: 6rrL4.4Ae Sub -basin: 7)3 - 04- - 0-7 Regional. Office: 1b11-aSti,ie‘Requestor: 5. Abd.t.41- �-iagq Type of Wastewater: Ind strial Domestic (6D If industrial, specify type(s) of industry: Receiving stream: Cl4vea. (Are-QR.- Class: a -5V\% Other stream(s) affected: Class: 7Q10 flow at point of discharge: 3 1 of s 30Q2 flow at point of discharge: Natural stream drainage area at discharge point: 7 3 rn 2- Recommended Effluent Limitations -boo o MS go - e ) D,OGncp This allocation is: / / for a proposed facility / / for a new (existing) facility / / a revision of existing limitations Y / a confirmation of existing limitations Recommended and reviewed by: /614) Date: Head, Techncial Services Branch Date: Reviewed by: Regional Supervisor Date: Permits Manager Date: Approved by: Division Director Date: DIVISION OF ENVIRONMENTAL MANAGEMENT MF'�'MORANDUM TO: Bill Mills, Supervisor Engineering and Permits Unit THROUGH: Jim Mulligan, Regional Supervisor Washington Regional Office FROM: Roger K. Thorpe,"aegional Engineer Water Quality Section-WaRO SUBJECT: NPDES Permit Renewal #NC0025712 Hookerton Waste Treatment Plant Greene County May 24, 1983 `0EIVED MAY 2 71983 WATER QUALITY SECTION OPERATIONS BRANCH NPDES Permit No. NC0025712 expires June 30, 1983. Renewal has been requested and an inspection was made on May 23, 1983. The Hookerton waste treatment plant is located as follows: From the Contentnea Creek Bridge on NCHwy 123 in Greene County, travel north on NC Hwy 123 for approximately 0.3 mile. Turn left (west) onto private dirt road and travel 0.7 mile to treat- ment facility. The receiving stream is Contentnea Creek in the Neuse River Basin. Contentnea Creek is classified Class C-SWP and has a 7-day, 10-year low flow of 31 CFS. The point of discharge is located at Latitude 350-25'-45" and Longitude 770-35'-35". The 0.06 MGD facility consists of a bar screen and three cell lagoon. This is a Class I facility. The current waste load allocation requires secondary treatment. Disinfection is not required due to the large amount of dilution. Based on self monitoring data, the facility has produced the following average effluent quality: BOD TSS 27 mg/1 27 mg/1 It is recommended that a five year permit be issued with Class I monitoring. ince this facility is a fairly significant discharge in the Neuse River Basin, it is recommended that Total N and Total P be monitored once during the term of the permit. RKT / ekw N)2 AUG 1983 PART ITT ermy _ No. NC OTHER REQUIREMENTS -ts for Effluent Limitations on Pollutants Attributable to :1. Users �t?144luent limitations from this discharger are listed in Part I of this permit. za�t is apparent that other pollutants attributable to inputs from major contributing industries using the municipal system may also be present in the Permittee's discharge. At such time as sufficient information becomes available to establish limitations for such pollutants, this permit may be revised to specify effluent limitations for any or all of such other pollutants ''in accordance with best practicable technology or water quality standards. Under no circumstances shall the permittee allow introduction of the following wastes into the waste treatment system: a. Wastes which create a fire or explosion hazard in the treatment works. b. Wastes which will cause corrosive structural damage to treatment works. c. Solid or viscous substances in amounts which cause obstructions to the flow in sewers or interference with the proper operation of the treatment works. d. Wastewaters at a flow rate and/or pollutant discharge rate which is excessive over relatively short time periods so as to cause a loss of treatment efficiency. e Heat in amounts which will inhibit biological activity in the treatment works resulting in interference but in no case heat in such quantities that the temperature at the treatment works influent exceeds 40°C (104°F) unless the works are designed to accomodate such heat. (After August 25, 1981) 3. With regard to the effluent requirements listed in Part I of this permit, it may be necessary for the permittee to supplement the requirements of the Federal Pretreatment Standards (40 CFR, Part 403) to ensure compliance by the permittee with all applicable effluent limitations. Such actions by the permittee may be necessary regarding some or all of the major contri- buting industries discharging to the municipal system. The permittee shall require each major contributing industry subject to pre-treatment standards or any other applicable requirements promulgated pursuant to Section 307 of the Act to submit to the permittee periodic notice (at intervals not to exceed 9 months) regarding specific actions taken to achieve full compliance with the requirements of Section 307. Starting on the permittee shall submit semi-annually to the permit issuing authority a report summarizing the progress of all known major contributing industries subject to the requirements of Section 307_owards full compliance with such requirements. Such report shall include at least the following information: M 13 PART iII Permit No. NC a. A narrative summary of actions taken by the permittee to ensure that all major contributing industries comply with the requirements of Section 307. b. The number of major contributing industries using the treatment works, divided into SIC group categories. c. The number of major contributing industries in full compliance with the requirements of Section 307, or not subject to these requirements (e.g., discharge only compatible pollutants). d. A list identifying by name those major contributing industries presently in violation of the requirements of Section 307. 4. Immediately upon issuance of this permit, the permittee shall establish and implement a procedure to obtain from all major contributing indus- tries specific information on the quality and quantity of effluents intro- duced by such industrial users. The following information shall be reported to the permitting agency on a quarterly basis beginning ; quarterly reports reflecting no change from the previous quarter may simply relate this fact, without submitting repetitive data. a. Section IV, Standard Form A shall be completed and submitted for each major contributing industry. b. Information on the municipal facility as a whole is to be reported on the monthly Monitoring Report Form (DEM - No. MR 1.0, 1.1, 1.2, and 1.3). Once the specific nature of industrial contributions has been identified, data collection and reporting requirements may be levied for other - parameters in addition to those included on Form (DEM No. 1.0, 1.1, 1.2, and 1.3). 5. Based on the information regarding industrial inputs reported by the permittee pursuant to the preceding paragraph, the permittee will be notified by the permitting authority of the availability of industrial effluent guidelines on which to calculate allowable inputs of incompatible pollutants based on BPT for each industry group. Copies of guidelines will be provided as appropriate. Not later than 120 days following receipt of this information, the permittee shall submit to the permitting authority calculations reflecting allowable inputs from each major con- tributing industry. The permittee shall also require all such major contributing industries to implement necessary pre-treatment requirements (as provided for in 40 CFR, Part 4o3), providing the permitting authority with notifications of specific actions taken in this regard. At that time, the permit may be amended to reflect the municipal facility's efflueAt!!L requirements for incompatible pollutants. - rt"_/*A"\ sup {V I A .a �r + 3.• _•II 14 B. PART iii Permit No. NC-c- 12 Previous Permits All prev'bus State water quality permits issued to this facility, whether for construction or operation or discharge, are hereby revoked by issuance of this permit. The conditions, requirements, terms, and provisions of this permit authorizing discharge under the National Pollutant Discharge Elimination System governs discharges from this facility. C. Construction No construction of wastewater treatment facilities or additions thereto shall be begun until Final Plans and Specifications have been submitted to the Division of Environmental Management and written approval and Authorization to Construct has been issued. If no objections to Final Plans and Specifications has been made by the DEM after 30 days following receipt of the plans or issuance of this permit, whichever is latter, the plans may be considered approved and construction authorized. D. Certified Operator Pursuant to Chapter 90A of North Carolina General Statutes, the permittee shall employ a certified wastewater treatment plant operator in responsible charge of the wastewater treatment facilities. Such operator must hold a certification of the grade equivalent to the classification assigned to the wastewater treatment facilities. E. Special Conditions In the event tnat violations of the fecal colifor:i requirements of the North Carolina water quality standards occur as a result of this discharge, disinfection will be immediately required and the permit amended to establish a coiiform limit. M 15 & I 12