Loading...
HomeMy WebLinkAboutNCG551361_Lab Data_20220817ENVIRONMENTAL - WATER SUPPLY - WASTEWATER - GEOTHERMAL.. CONNER CONSULTING, LLC 1284 WINDY RIDGE ROAD, CHAPEL HILL, NORTH CAROLINA 27517 PHONE: (919) 260.7301 August 17, 2022 Mr. Leroy Hutto 25 South Circle Drive Chapel Hill, North Carolina 27516 Re: Effluent Sampling 25 South Circle Drive Chapel Hill, North Carolina Dear Mr. Hutto: NCG-55 IU7 On June 9, 2022, Conner Consulting collected effluent samples as required on your DWQ permit at 25 South Circle Drive, Chapel Hill, North Carolina. The results are as follows: Flow: <:: 200 gpd (estimated) Total Residual Chlorine: 0.30 parts per million @ 12:05 Biochemical Oxygen Demand: 4.4 mg/l Total Suspended Solids: 32 mg/l Fecal Coliform: 610 CFU/100 ml. I suggest adding chlorine tablets more frequently to reduce the fecal coliform. My field laboratory certification is #5149. Please call with questions and comments. Sincerely yours, Chad Leinbach Conner Consulting, LLC Field Laboratory Certification #5149 CC: Mitch Hayes, Surface Water Protection, NC DWQ ENCO Laboratories Accurate. ime ►. Responsive. Innovative. 102-A Woodwinds Industrial Court Cary NC, 27511 Phone: 919.467.3090 FAX: 919.467.3515 Monday, June 20, 2022 CONNER CONSULTING (C0036) Attn: Chad Leinbach 1284 WINDY RIDGE RD CHAPEL HILL, NC 27517- RE: Laboratory Results for Project Number: HUTTO/ SOUTH CIRCLE, Project Name/Desc: Wastewater-Misc. ENCO Workorder(s): CF08917 Dear Chad Leinbach, Enclosed is a copy of your laboratory report for test samples received by our laboratory on Thursday, June 9, 2022. Unless otherwise noted in an attached project narrative, all samples were received in acceptable condition and processed in accordance with the referenced methods/procedures. Results for these procedures apply only to the samples as submitted. The analytical results contained in this report are in compliance with NELAC standards, except as noted in the project narrative if applicable. This report shall not be reproduced except in full, without the written approval of the Laboratory. This report contains only those analyses performed by Environmental Conservation Laboratories. Unless otherwise noted, all analyses were performed at ENCO Cary. Data from outside organizations will be reported under separate cover. If you have any questions or require further information, please do not hesitate to contact me. Sincerely, Daniel G. Harmon For Amanda L. Gaines Project Manager Enclosure(s) FI W5L This report relates only to the sample as received by the la boratory, and may only be reproduced In full. Page 1 of 7 www.encolabs.com SAMPLE SUMMARY/ LABORATORY CHRONICLE 1 Client ID: EFF- SOUTH CIRCLE Lab ID: CFOB917-01 Sampled: 06/09/22 12:00 Received: 06/09/22 16:20 Parameter Collett 18 SM 2540D-2011 SM 5210 8-2011 Preparation NO PREP NO PREP NO PREP Mold Date/Tlme(4 prep Date/Time(s) 06/09/22 19:55 06/10/22 14:39 06/09:22 16:35 06/16/22 06/15122 15:40 06/11/22 12:00 06/10122 13:11 Analvsis Date/Times-1 06/10/22 11:20 06/15/22 15:40 06/10/22 13:11 FINAL ibis report relates only to the sample as received by the laboratory, and may only be reproduced In MI, Page 2 of 7 www.encolabs.com SAMPLE DETECTION SUMMARY Client ID: EFF- SOUTH CIRCLE _ I &abet! linamHa Flan Mk EQL Valli Rattan Nato Biochemical Oxygen Demand 4.4 2.0 2.0 mg/1 5h1 5210 B-2011 Collfarm, Fecal 610 1.0 1.0 MPN/100 mL Coiilert 18 Total Suspended Solids 32 8.3 8.3 mg/L SM 2540D-2011 Lab ID: CF08917-01 flrwL Thls report relates only to the sample as received by the laboratory, and may only be reproduced In hell. I Page3of7 www.encolabs.com ANALYTICAL RESULTS Description: EFF- SOUTH CIRCLE Matrix: Waste Water Project: Wastewater-Misc. Lab Sample ID: CF08917-01 Sampled: 06/09/22 12:00 Sampled By:Chad Leibach Received: 06/09/22 16:20 Work Order: CF08917 Classical Chemistry Parameters Anatabe fCAS Numbed Biochemical Oxygen Demand Total Suspended Solids Results Elsa linital 4.4 mg/L 32 mg/L 12E MRL ItQl. la1sll Me had Anahaald Sic &to 1 2.0 2.0 2F10006 SM 5210 8-2011 06/10/22 13:11 IOC 3.33 8.3 8.3 2F15009 SM 25400-2011 06/15/22 15:40 DM) Microbiological Parameters Arafirte fCAS Numbed CoIttomt, Fecal Rog& flag Units PE MQL !Mk liatsb Method Anahasal Iv MAU 610 MPN/100 1 1.0 2F13013 Calllert 18 06/10/22 11:20 MY mL FINO.L INS report relates only to the sample as received by the laboratory, and may ony be reproduced In full. Page 4of7 www.encolabs.com QUALITY CONTROL DATA (Classical Chemistry Parameters - Quality Control Batch 2F10006 - NO PREP Blank(2F10006-BLK1) Prepared & Analyzed: 06/10/2022 13:11 Anakte Biochemical Oxygen Demand Result Flea 2.0 U Spike P01 Malta Level 2.0 mg/L Source Result %REC %REC Llmtitt RPD RPD l.imlt 1a. LCS(2F10006-BSI) Prepared & Analyzed: 06/10/2022 13:11 AMMO Biochemical Oxygen Demand Result Flae 200 MIL Mitt 2.0 mg/L Spike Level 198 Source Result %REC %REC umka 102 85-115 RPD RPD Una til2t8a Duplicate (2F10006-DUP1) Prepared & Analyzed: 06/10/2022 13:11 Source: CF05210-01 Aaah6e Biochemical Oxygen Demand Batch 2F15009 - NO PREP Spike Source Result Flan P41 Units Level KUHR 6.2 2.0 mg/L 6.0 %REC RPD %REC until RPD Lim Hetet 3 30 Blank(2F15009-BLK1) Prepared & Analyzed: 06/15/2022 15:40 Aaatvt Total Suspended Solids LCS(2F15009-BS1) Spike Source %REC RPD Result flan PC& Units Level Result %REC Limits RPD Limit Nam 2.5 U 2.5 mg/L Prepared & Analyzed: 06/15/2022 15:40 Spike Source %REC RPD _AMMO Result Else LOL Units Level Rai11R %REC Limits RPD Limit Mtsl. Total Suspended Solids 110 2.5 mg/L 100 107 80-120 Duplicate (2F15009-DUP1) Prepared & Analyzed: 06/15/2022 15:40 Source: CF08837-01 Spike Source %REC RPD _AMMO Result Elsa POL Units Level Result %REC Llmtt4 RPD Limit Rolm Tow Suspended Solids 130 25 mg/L 120 3 20 Duplicate (2F15009-DUP2) Prepared & Analyzed: 06/15/2022 15:40 Source: CF08837-02 Spike Source %REC RPD _AMMO Result Flan NH. Unita Level gala %REC Llmlta RPD um lyobes Total Suspended solds 63 25 mg/L 59 7 20 'Microbiological Parameters - Quality Control Bath 2F13013 - NO PREP Duplicate (2F13013-DUPI) Prepared: 06/09/2022 15:03 Analyzed: 06/10/2022 11:20 Source: CF08027-02 jamb _Makers_MakersResult flan P0L Units SLevel pike Source %REC RPD Enid %REC RPD unlit tY4ta_ colifcm, Fecal 1.0 U 1.0 MPN/100 mL 1.0 U 25 FLHBI This report relates only to the sample as receives by the laboratory, and may only be reproduced In full. Page 5 of 7 J www.encolabs.com 1 FLAGS/NOTES AND DEFINITIONS B The analyte was detected in the associated method blank. D The sample was analyzed at dilution. ] The reported value is between the laboratory method detection limit (MDL) and the laboratory method reporting limit (MRL), adjusted for actual sample preparation data and moisture content, where applicable. U The analyte was analyzed for but not detected to the level shown, adjusted for actual sample preparation data and moisture content, where applicable. E The concentration indicated for this analyte is an estimated value above the calibration range of the instrument. This value is considered an estimate. MRL Method Reporting Limit. The MRL is roughly equivalent to the practical quantitation limit (PQL) and is based on the low point of the calibration curve, when applicable, sample preparation factor, dilution factor, and, in the case of soil samples, moisture content. PQL PQL: Practical Quantitation Limit. The PQL presented is the laboratory MRL. N The analysis indicates the presence of an analyte for which there is presumptive evidence (85% or greater confidence) to make a "tentative identification". P Greater than 25% concentration difference was observed between the primary and secondary GC column. The lower concentration is reported. [CALC] Calculated analyte - MDL/MRL reported to the highest reporting limit of the component analyses, fl Wd This report relates only to the sample as received by the laboratory, and may only be reproduced In full. Page 6 of 7 ph i 1111111 III I! 1 a I i 1 Page7of7