HomeMy WebLinkAboutWQ0001077_BIMS Report_20220810Compliance Inspection Report
Permit: WQ0001077 Effective: 08/01/21
SOC: Effective:
County: Rowan
Region: Mooresville
Expiration: 06/30/27
Expiration:
Contact Person: Vic Jameson Title: Vice President
Directions to Facility:
From Salisbury, travel north on 1-85 to exit 81. At the top of the exit ramp turn left and cross over the highway.
Lane. The plant entrance is at the end of the road (approx. 0.75 miles).
System Classifications: WW2, SI,
Primary ORC: James Cloyd White Certification: 25861
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
NC0023884 City of Salisbury - City of Salisbury WWTP
Inspection Date: 08/05/2022 Entry Time 09:OOAM
Primary Inspector: Edward Watson
Secondary Inspector(s):
Reason for Inspection: Routine
Permit Inspection Type: Wastewater Irrigation
Facility Status: Compliant ❑ Not Compliant
Question Areas:
▪ Treatment Flow Measurement -Effluent
▪ Treatment Flow Measurement -Water
Use Records
▪ Treatment Lagoons
▪ Treatment Influent Pump Station
▪ Wells
(See attachment summary)
Exit Time: 10:30AM
Owner : Innospec Active Chemicals LLC
Facility: Innospec Active Chemicals - Salisbury WWTF
500 Hinkle Ln
Salisbury NC 28144
Phone: 704-633-8028
Turn right onto Hinkle
Phone: 704-633-8028
Phone:
Inspection Type: Compliance Evaluation
▪ Treatment Flow Measurement -Influent
▪ Treatment
▪ Treatment Sludge Storage/Treatment
▪ Treatment Flow Measurement
▪ Miscellaneous Questions
▪ Record Keeping
▪ End Use -Irrigation
▪ Storage
Page 1 of 6
Permit: WQ0001077 Owner - Facility: Innospec Active Chemicals LLC
Inspection Date: 08/05/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Inspection Summary:
On August 5,2022, MRO staff performed a Compliance Evaluation Inspection for permit WQ0001077.
The primary treatment lagoon and DAF opeartions were reviewed during the site visit. The system appears to be operating
within the limits of the permit.
The application field did not have any dead areas. There was no ponding observed. However, the spray application does not
overlap to complete coverage. MRO remined Innospec personel that spray head calibration be conducted once every permit
cycle.
MRO staff verified the submittal of the June 2022 reports. MRO staff also received a copy of these reports.
Page 2 of 6
Permit: WQ0001077 Owner - Facility: Innospec Active Chemicals LLC
Inspection Date: 08/05/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Type
Reuse (Quality)
Infiltration System
Single Family Spray, LR
Activated Sludge Spray, LR
Activated Sludge Spray, HR
Recycle/Reuse
Activated Sludge Drip, LR
Single Family Drip
Lagoon Spray, LR
Treatment
Are Treatment facilities consistent with those outlined in the current permit?
Do all treatment units appear to be operational? (if no, note below.)
Yes No NA NE
•
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: Aerators were in operation during the site visit. No dead areas were observed across the
lagoon.
Treatment Influent Pump Station
Is the pump station free of bypass lines or structures?
Is the general housekeeping acceptable?
Are all pumps present?
Are all pumps operable?
Are floats/controls operable?
Are audio and visual alarms available?
Are audio and visual alarms operational?
# Are SCADA/Telemetry alarms required?
Are SCADA/Telemetry available?
Are SCADA/Telemetry operational?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
Comment: If the treatment system fails, an alarm sound in the manufacturing building and someone will be
dispatched to correct the system or turn the system off so the treatment system does not
operate in a failure mode.
Treatment Flow Measurement -Influent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Page 3 of 6
Permit: WQ0001077 Owner - Facility: Innospec Active Chemicals LLC
Inspection Date: 08/05/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Comment: Wastewater effluent flow meters are changed annually to maintain calibration. Effluent flow is
split between the City of Salisbury Grants Creek WWTP and the permitted spray irrigation
system. Any remainder is recycled back to the second lagoon to await distribution to the spray
irrigation system.
Treatment Flow Measurement -Water Use Records
Is water use metered?
Are the daily average values properly calculated?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The flow to the spray irrigation system is monitored and submitted to DWR RO monthly via the
NDMR report. The facility is within the permit limits for flow.
Treatment Flow Measurement -Effluent Yes No NA NE
Is flowmeter calibrated annually? • ❑ ❑ ❑
Is flowmeter operating properly? • ❑ ❑ ❑
Does flowmeter monitor continuously? • ❑ ❑ ❑
Does flowmeter record flow? • ❑ ❑ ❑
Does flowmeter appear to monitor accurately? • ❑ ❑ ❑
Comment: Flow is recorded manually on a daily basis. Data in kept on an Excel spreadsheet that is
maintained by the operator.
Treatment Sludge Storage/Treatment
Is the aeration operational?
Is the aeration pattern even?
If required, are Sanitary "Ts" present in tankage?
Comment: The aeration pattern was observed to be even across the primary treatment lagoon.
Record Keeping
Is a copy of current permit available?
Are monitoring reports present: NDMR?
NDAR?
Are flow rates less than of permitted flow?
Are flow rates less than of permitted flow?
Are application rates adhered to?
Is GW monitoring being conducted, if required (GW-59s submitted)?
Are all samples analyzed for all required parameters?
Are there any 2L GW quality violations?
Is GW-59A certification form completed for facility?
Is effluent sampled for same parameters as GW?
Do effluent concentrations exceed GW standards?
Are annual soil reports available?
# Are PAN records required?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑•
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ • ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
• ❑ ❑ ❑
Page 4 of 6
Permit: WQ0001077 Owner - Facility: Innospec Active Chemicals LLC
Inspection Date: 08/05/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
# Did last soil report indicate a need for lime?
If so, has it been applied?
Are operational logs present?
Are lab sheets available for review?
Do lab sheets support data reported on NDMR?
Do lab sheets support data reported on GW-59s?
Are Operational and Maintenance records present?
Were Operational and Maintenance records complete?
Has permittee been free of public complaints in last 12 months?
Is a copy of the SOC readily available?
No treatment units bypassed since last inspection?
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The O&M records are up-to-date. All of the required reports have been submitted. No GW
violations are reported for the permit. The lab reports were reviewed with the GW-59 records.
End Use -Irrigation
Are buffers adequate?
Is the cover crop type specified in permit?
Is the crop cover acceptable?
Is the site condition adequate?
Is the site free of runoff / ponding?
Is the acreage specified in the permit being utilized?
Is the application equipment present?
Is the application equipment operational?
Is the disposal field free of limiting slopes?
Is access restricted and/or signs posted during active site use?
Are any supply wells within the CB?
Are any supply wells within 250' of the CB?
How close is the closest water supply well?
Is municipal water available in the area?
# Info only: Does the permit call for monitoring wells?
Are GW monitoring wells located properly w/ respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
Are monitoring wells damaged?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
▪ •
▪ •
▪ •
• ❑ ❑•
•
❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
▪ •
Comment: A new tag has been placed on the MW-8 well. The area around the wells is maintained. The
wells are easily accessible to staff.
01 -
Treatment Lagoons
Lagoon Type
Yes No NA NE
Aerated
Page 5 of 6
Permit: WQ0001077 Owner - Facility: Innospec Active Chemicals LLC
Inspection Date: 08/05/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Primary/Secondary Primary
Influent structure • ❑ ❑ ❑
Banks/berms (seepage and erosion) • ❑ ❑ ❑
Vegetation (excessive vegetation on banks/berms) • ❑ ❑ ❑
Liner • ❑ ❑ ❑
Liner Type Unknown
Baffles/curtains • ❑ ❑ ❑
Freeboard Marker • ❑ ❑ ❑
Required freeboard 2
Feet
Actual freeboard 4
Feet
Are increments clearly marked on gauge at adequate intervals? • ❑ ❑ ❑
Has the water level gauge been surveyed w/ respect to lowest point on dike? wall? • ❑ ❑ ❑
No Evidence of overflow • ❑ ❑ ❑
Acceptable color • ❑ ❑ ❑
Floating mats • ❑ ❑ ❑
Excessive solids buildup • ❑ ❑ ❑
Aerators/mixers • ❑ ❑ ❑
Effluent structure • ❑ ❑ ❑
Lagoon cover • ❑ ❑ ❑
Page 6 of 6