Loading...
HomeMy WebLinkAboutWQ0043662_Application (FTSE)_20220812June 1, 2022 NCDENR-DWQ Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301 RE: Graves & Gruber St AAFES Fast Track Application for Gravity Sewer Extension Cumberland County, North Carolina • •.ASUS • . • • •Servin9 Those Who Serve. RECEIVED 2:03 AUG 0 9 2022 DEQ-FAYETTEVILLE REO'.ONAL OFFICE We are providing the enclosed information for the permitting of new sewer infrastructure for the Graves & Gruber St AAFES. A new 8-inch gravity sewer main and manholes will be installed to convey wastewater from one new building located on the corner of Gruber Rd & Graves St to the downstream collection system. The 8-inch main will discharge into the proposed manhole that will convey flow downstream through the existing 8-inch gravity sewer main located adjacent to Graves Street. Two 4-inch sanitary sewer laterals and cleanouts will be installed to collect and discharge wastewater into the proposed 8-inch main. The Graves & Gruber St AAFES Building is a convenience store with/without food preparation with a maximum occupancy of 335 people with 14 plumping fixtures. The square footage of the food preparation area is 1,883 square feet; the additional wastewater flow from this building is estimated to be 4,630 gallons per day. Enclosed please find the original and one copy of the following: • NCDENR Fast Track Application • Checkfor$480.00 • USGS and Street Level Map Showing the Project Area • Graves & Gruber St AAFES Building Flow Calculations • Flow Tracking/Acceptance Form Thank you for your consideration in this matter. If you require further information, please do not hesitate to contact me at (910) 987-1950 or Rachelle.Roberge@asusinc.com. Sincerely, an.a,DIlo3 Rachelle Roberge, PE Senior Engineer American States Utility Services, Inc. P.O. Box 73316, Fort Bragg, NC 28307 Tel: (910) 495-1311 Fax: (910) 495-1310 a Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources ISA NCAC 02T .0300 —FAST TRACK SEWER SYSTEM EXTENSION APPLICATION INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of ISA NCAC 02T and the Division's Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, 15A NCAC 02T ISA NCAC 02'f .0300, Division policies and good enaineering practices. While no upfront engineering design documents are required for submittal, in accordance with ISA NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in ISA NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in ISA NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ➢ Projects that require an environmental assessment in accordance with ISA NCAC IC .0100; ➢ Projects that do not meet any part of the minimum design criteria (MDC) document; ➢ Projects that involve a variance from the requirements of 15A NCAC 2T; > Pressure sewer systems utilizing septic tank -effluent pumps (STEPS) or simplex grinder pumps; ➢ STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); ➢ Vacuum sewer systems. General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents Required unless otherwise noted B. Cover Letter (Required for All Application Packages): El List all items included in the application package, as well as a brief description of the requested permitting action. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. > If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Major Modification Application Packages): El Submit a check or money order in the amount of 5480.00 dated within 90 days of application submittal. ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages): Submit the completed and appropriately executed application. ➢ If necessary for clarity or due to space restrictions, attachments to the application may be made. El If the Applicant Type in Item 1.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item I.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item Ili shall be consistent with the project name on the flow acceptance letters, agreements, etc. El The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. El The Applicant's Certification on Page 5 of the application shall be signed in accordance with ISA NCAC 02T .0106(b). Per ISA NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .01.06(b). INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 1 of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (lf Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. ➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. D The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. ➢ Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143- 215.67(a). A. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): El Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters. ➢ Location of the project (gravity sewer, pump stations & force main) ➢ Downstream connection points and permit number (if known) for the receiving sewer ® Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field. G. Existing Permit (All Modification Packages): ❑ Submit the most recently issued existing permit. ❑ Provide a list of any items within the permit the Applicant would like the Division to address during the permit modification (i.e., permit description, flow allocation, treatment facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per I5A NCAC 02T .0305(h)(1), submit documentation of power reliability for pumping stations. ➢ This alternative is only available for average daily flows less than 15,000 gallons per day > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per 15A NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for Tots to be sold): ❑ Home/Property Owners' Associations ❑ Per 15A NCAC 02T .0115(c) submit the properly executed Operational Agreement (FORM: NOA). ❑ Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ❑ Developers of lots to be sold O Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (FORM: DEV). For more information, visit the Division's collection systems website INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Water Quality Section Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5094 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Water Quality Section Mooresville Regional Office 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Water Quality Section Raleigh Regional. Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788-7159 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Water Quality Section Washington Regional Office 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Water Quality Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Water Quality Section Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 Alamance, Allegheny, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin Water Quality Section INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3 D.., Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources ISA NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number�a�j�('Jjbe completed by DWR) AU items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: Old North Utility Services. Inc. (company, municipality, HOA, utility, etc.) 2. Applicant type: 0 Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility 0 Federal 0 State/County 0 Municipal ❑ Other 3. Signature authority's name: Timothy Loughman per 15A NCAC 02T .0106(h) Title: Utility Manager 4. Applicant's mailing address: P.O. Box 73316 City: Fort Bragg State: NC Zip: 28307- 5. Applicant's contact information: Phone number: (910) 495-1311 Email Address: Timothy.Louahman(nlasusinc,com II. PROJECT INFORMATION: 1. Project name: Graves & Gruber St AAFES RECEIVED AUG 0 9 2022 t.r03 DEO-FAVETTEVILLE REOtONAL OFFICE 2. Application/Project status: ® Proposed (New Permit) 0 Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Cumberland County 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.155° Longitude: -78.977° 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Rachelle Roberge License Number: 42922 Firm: American States Utility Services, Inc. Mailing address: 903 Armistead Street City: Fort Braaa State: NC Zip: 28307- Phone number: (910) 495-1311 Email Address: Rachelle.Roberae(nlasusinc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. . Facility Name: South Harnett Regional WWII) - Permit Number: NC10088366 Owner Name: ,Harnett County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. PermitNumber(s): WQ Downstream (Receiving) Sewer Size: inch System Wide Collection System Permit Number(s) (if applicable): WQCS00029 Owner Name(s): Old North Utilities Services FORM: FTA 04-16 Page 1 of 5 Vl. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No I:IN/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Residential Leased ❑ School / preschool / day care ❑ Food and drink facilities O Businesses / offices / factories ❑ Yes ❑No SIN/A 0 Retail (stores, centers, malls) ® Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial 0 % Industrial (See 15A NCAC 021' .0I03(20)) >ls there a Pretreatment Program in effect? 0 Yes 6. Has a flow reduction been approved under I5A NCAC 02T .01 l4(1)? 0 Yes ® No ➢ If yes, providea copy of flow reduction approval letter 7. Summarize wastewater generated by project: ® No Establishment Type (see 02T.0114(f) Daily Design Flow o'b No. of Units Flow Conveince Store without Food Preparation 250 gal/Plumping Fixture 14 3,500 GPD Conveince Store with Food Preparation 60 gal/100 SF Floor Space 1,883 1,130 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 4,630 GPD a See 1 SA NCAC 02T .0114(h). (d). (a)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per ISA NCAC 02T .0114(c), design flow rates for establishments not identified [in table I5A NCAC 0YT.01 14] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0.00462 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line O Flow has already been allocated in Permit Number: 0 Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 304 PVC > Section [I & III of the MDC for Permitting of Gravity Sewers contains information rela ed to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: _ 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - . 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head ('I'DH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with I5A NCAC 021' .0305(h)(11: ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(3): > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be pertnanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - ISA NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(I)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS —(02B.0200 & 15A NCAC 02T .0305(0): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(1) & (a) A 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ZYcs No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class 1 or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or groundwater lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(al contains alternatives where separations in 02T.030501 cannot be achieved. A **Stream classifications can be identified using the Division's NC Surthee Water Classifications webpage ➢ If noncompliance with 02T.0305(t) or (k) see Section X of this application 2. Does the project comply with separation requirements t'or wetlands? (50 feet of separation) ® Yes ❑ No ❑ N/A A See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B ,0200? ® Yes ❑ No ❑ N/A A This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? A Information can be obtained from the 401 & Buffer Permitting Branch ❑ Yes ® No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per I5A NCAC 02T.0105(c)(61 directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402 "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ®No ❑ N/A A If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I5A NCAC 02T the Minimum Design Criteria fbr the Permitting or Pump Stations and Force Mains (latest version) and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: 1, Rachelle Roberge, PE attest that this application for (Professional Engineer's name from Application Item TILL.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25.000 per violation. • ,ltt%U111II11j North Carolina Professional Engineer's seal, signature, and date: i %%% CAR 4,• 1-� 'Essi Ali�G 2:a SEAL Y 42922 Digitally signed ��g� by Rachelle gideeetirkW Roberge Date: 2022.06.01 10:46:52 -07'00' 3. Applicants Certification per 15A NCAC 02T .0106(b): %.0 ..f uttr t 1, Timothy Loughman, Utility Manager attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6t3, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: au /DI IgZZ- FORM: ETA 04-16 Page 5 of 5 • :: • SUS ving These Who Serve. Project Name: Graves & Gruber AAFES Description: A new 8-inch gravity sewer main and manholes will be installed to convey wastewater from one new building located on the corner of Gruber Rd & Graves St to the downstream collection system. The 8-inch main will discharge into the proposed manhole that will convey flow through downstream through the existing 8-inch gravity sewer main located adjacent Graves Street. Two 4-inch sanitary sewer laterals and cleanouts will be installed to collect and discharge wastewater into the 8-inch main. Graves & Gruber AAFES Building Building square footage: 15,072 Building Type: IIB—Convenience Store with Food Preparation Building Type: IIB —Convenience Store without Food Preparation Max No. Occupants: 335 No. Plumbing Fixtures: 14 Flow Criteria: Convenience Store with Food Preparation — 60 gpd/100 SF Floor Space Convenience Store without Food Preparation —250 gpd/Plumbing Fixture Additional Daily Flow into Sewer System: (60 x (1883/100) gpd =1129.8 gallons per day or 0.0011298 MGD (250 x 14) gpd = 3,500 gallons per day or 0.0035 MGD Total : 0.004629 MGD American States Utility Services, Inc. P.O. Box 73316, Fort Bragg, NC 28307 Tel: (910)495-1311 Fax: (910) 495-1310 Pump Station (Name or Number) Division of Waxer ?;csoairces State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Old North Utilities Services, Inc. Project Name for which flow is being requested: Graves and Gruber St AAFES More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: South Harnett Regional Water WWTP b. WWTP Facility Permit #: NC 008366 All flows are in MGD c. WWTP facility's permitted flow 15.000 d. Estimated obligated flow not yet tributary to the WWTP 5.356 e. WWTP facility's actual avg. flow 5.629 f. Total flow for this specific request 0.005 g. Total actual and obligated flows to the facility 10.990 h. Percent of permitted flow used 73.27% H. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWI?: (A) (B) (C) (DHB+C) Approx. Design Current Obligated, Total Average Daily Avg. Not Yet Current Flow** Daily Tributary Flow Plus (Firm / pf), Flow, Daily Flow, Obligated MGD MGD MGD Flow UPSTREAM SLS CAP INFO 19.5 7.8 2.249 0.017 2.266 Pump Station Firm Permit Capacity, No, MGD CONTACT ONUS FOR SLS #74 (E).--(A-D) Available Capacity*** 5.534 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the W WTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): South Harnett Regional WWTP Downstream Permit Number: NC 008366 Page 1 of 6 FTSE 10-18 III. Certification Statement: I _^S e_ kyi( • certify to the best of my knowledge that the addition of the vorume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacityto transport and treat the proposed new wastewater. 7-2 Signing Official Signature Date ire c -rpr Title of Signing Official Page 2 of 6 FTSE 10-18 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Old North Utilities Services, Inc. Project Name for which flow is being requested: Graves and Gruber St AAFES More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: b. WWTP Facility Permit #: c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flaws are in MGD .00462 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pt), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pi) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Downstream Permit Number: Page 1 of 6 FTSE 04-16 III. Certification Statement: I Amos-tkl Act (vt uu n J certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Offici S gnature Date Page 2 of 6 FTSE 04-16 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for % and MGD of the Available Capacity (E) in Pump Station ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately MGD pet year; and that c. A funded Capital Project that will provide the required planned capacity, namely is in design or under construction with planned completion in ; and/or d. The following applies: Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143- 215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. 1JL 4.i Signing Offici t ignature Page 3 of 6 Date FTSE 04-16 Planning Assessment Addendum Instructions Submit a planning assessment addendum for each pump station listed in Section II where available capacity is<0. A planning assessment for Kaw Creek PS (see example data above) may be performed to evaluate whether there is significant likelihood that needed improvements or reductions in obligated flows will be in place prior to activating the flows from the proposed sewer extension project. If the system decides to accept the flow based on a planning assessment addendum, it is responsible to manage the flow without capacity related sanitary overflows and must take all steps necessary to complete the project or control the rate of flow to prevent sanitary sewer overflows. The planning assessment may identify a funded project currently in design or construction, or a planned project in the future not yet funded but in a formal plan adopted by the system. The system should carefully weigh the certainty of successful timely project completion for any expansion, flow management diversion or infiltration and inflow elimination projects that are the foundation of a planned solution to capacity tracking and acceptance compliance. For example: Given that: a. The proportion and amount of obligated, not yet tributary flow accounts for 24 % and 0.080 MGD of the committed flow in Pump Station Kaw Creek; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.01 MGD per year; and that c. A funded capital project that will provide the required planned capacity, namely is in design or under construction with planned completion in ; and/or d. The following applies: The master plan and ten year capital plan contain recommended scope and funding for a capital project entitled Kaw Creek Pump Station upgrade with funding planned in July 2014. This project is planned to add 0.100 MGD to the firm capacity of the pump station by October 2015. Inclusion of this proposed capital project as a condition of this Flow Trackinu/Acceptance for Sewer Extension Permit Application elevates this project's priority for funding and construction to be implemented ahead of the activation of obligated, not yet tributary flows in amounts that exceed the firm pump station capacities identified in Section II above. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. Page 6 of 6 FTSE 04-16 co to c (0 W � � � � 2 � 13 c @ $ > 0 ) § Freshwater Emergent Wetland Freshwater Forested/Shrub Wetland M� Estuarine and Marine Deepwater > Freshwater Pond Estuarine and Marine Wetland The National Map Advanced Viewer 5/9/2022 10:04:52 AM N O n CJ O t- 0 - O Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources ISA NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number c completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Old North Utility Services. Inc. (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation 0 General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County 0 Municipal ❑ Other 3. Signature authority's name: Timothy Loughman per 15A NCAC 02T .0106( b) RECEIVED Title: Utility Manager 4. Applicant's mailing address: P.Q. Box 73316 AU G 0 9 2022 City: Fort Bragg State: NC Zip: 28307- 5. Applicant's contact information: ' 0 3 Phone number: (910) 495-1311 Email Address: Timothv.Loughmanc asusinc.com DEQ-FAVETTEVILLE REGIONAL OFFICE 11. PROJECT INFORMATION: 1. Project name: Graves & Gruber St AAFES 2. Application/Project status: ® Proposed (New Permit) 0 Existing Permit/Project If a modification, provide the existing permit number: W000 and issued date: If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Cumberland County 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.155° Longitude: -78.977° 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Rachelle Roberge License Number: 42922 Firm: American States Utility Services. Inc. THIS CHECK IS VOID A BLOEBACKGROUND.AND .ATRUEWATERMARK HOLD DP,TO'LId3ITTb+SEE!SAFE AND "VERIFY ^MST" SIN THE PAPER` ITIL":ITY SERVICES IN'CC 06fIHItoy,.1.4,OteilekitBY.Ns eluay E.r roe 3O E FQOTH)LL BLVD AMD/MAS eA 9177:ki2'T3 FUR HUNDRED" ICsHTY ND OO/1 OO PAYTHE ' NC16b6 DEPT OF: ENVIRONMENTAL QUALITY SERVICE CENTER THE iiRDER 512 N`SALISBURY STREET DF .:RALEIGH NC 27604-1148 WELLS FARORS STGO BANK $3a S H LOS ANGELE$QA WD71 1 rm" ulb 6/3/22 $*****,.*480.00 ':