Loading...
HomeMy WebLinkAbout20061617 Ver 1_More Info Received_20070912WITHERS a RAVENEL ENGINEERS I PLANNERS I SURVEYORS lli MacKenan Drive CARY, NORTH CAROLINA, 275ii (919) 469-3340 FAX (919) 467-6008 To: North Carolina Division of Water Quality 2321 Crabtree Boulevard, Suite 250 Raleigh, North Carolina 27607 WE ARE SENDING YOU ^ Shop Drawings ^ Copy of Letter ® Attached ® Prints ^ Change order oniE o /X207 los No. 020 0261.0 "'~N10N Annette Lucas PHONE# 7 -1786 RE: Wendell Falls Subdivision Marks Creek {0 0 02, 27- 8, C, NSW} DWQ Pro'ect #06-1617 ^ Under separate cover via _ ^ Plans ^ Samples ^ Diskette ^ the following items: ^ Specifications COPIES DATE NO. DESCRIPTION D Detention Pond Plan S Stormwater Manas;ement Report THESE ARE TRANSMITTED as checked below: ® For approval ^ Approved as submitted ^ Resubmit copies for approval ^ Foryour use ^ Approved as noted ^ Submit copies for distribution ^ As requested ^ Returned for corrections ^ Return corrected prints ^ For review and comment ^ ~ O ^ FOR BIDS DUE 20 ^ PRINTS RETURNED AFTER LOAN T SEP 1 2 2007 REMARKS: DENR • WAT wFn~DS MID StOR~WAIFR BRANCH COPY TO: File SIGNED: Ken Jesneck, PE if enclosures are not as noted, kindly notify us at once. WITHERS t L~~ September 12, 2007 Ms. Annette Lucas North Carolina Division of Water Quality 2321 Crabtree Boulevard, Suite 250 Raleigh, North Carolina 27604 Re: Additional Information Request Wendell Falls DWQ Project #06-1617 Marks Creek {030402. 27-38, C, NSW} W&R Project 02050261.04 Dear Ms. Lucas: RAVEN EL ENGINEERS I PLANNERS I SURVEYORS Attached you will find five (5) copies of the information requested for the proposed dry detention pond for the future Wendell Fall Parkway. This submittal includes five plan sheets for the dry detention pond and associated level spreader as well as the Stormwater Management Report that provides the supporting calculations. The dry detention pond has been designed to capture the runoff from the first of precipitation and release over a 2-5 day period. The outlet structure has been design to allow larger rainfall events to bypass the level spreader. I hope we have providing sufficient responses for additional information request. If you have any questions, please feel free to contact met at (919) 469-3340 or email at kjesneck@withersravenel.com. Sincerely, WIT ERS l A ENEL, INC. en Jesneck, PE Project Manager CC: Mike Jones -Wendell Falls Residential, LLC Qr~c~r~ae~~ SEP 1 2 2007 DENR -WATER pUALITY WETLANDS AND STOR~''lAT6R 9RANCH iii MacKenan Drive i Cary, North Carolina z75ii i tel: 919.469.3340 i fax: 919.467.6008 i www.withersravenel.com 7040 Wrightsville Avenue, Suite lol i Wilmington, North Carolina 28403 i tel : 910.256.9277 i fax : 91o.z56.z584 1027 Sabbath Home Road SW i Supply, NC z846z i tel: 910-842-9392 i fax: 91o.84z.8o19 ~ to - I lv l ~( WITHERS ~~ RAVENEL WENDELL FALLS PARKWAY STORMWATER MANAGEMENT REPORT Wendell Falls Subdivision Wendell, North Carolina Prepared For: Wendell Falls Residential, LLC 566o Six Forks Road Suite #202 Raleigh. NC 27609 Attn: Mike Jones ~~~~ V ~ O Prepared By: WITHERS &RAVENEL, INC SEP 1 2 2007 11i MacKenan Drive Cary, North Carolina 275ii 3~A~S7TOR A~TMRNrCH September zoo? W&R Project No. 2o526i.o4 `,,~ffffftftflf~I ,e ~~ ~¢~H CARD( j'°a p~G .•••.... , ~Y/ya PYl(+(~~C'ESS~~•i !/LV f ~f1~3 ~~NGI E~~'s~ '•••...N.••• G. ~FTH L. lES~~. `` ~~'/`~1~ tet fl~~ t 1~ ~_ r WENDELL FALLS SUBDIVISION WENDELL FALLS PARKWAY STORMWATER MANAGEMENT PLAN WENDELL, NORTH CAROLINA INTRODUCTION The purpose of this Wendell Fall Parkway Stormwater Management Report is to document the design of the dry detention pond for a storm water outlet from the future Wendell Falls Parkway. The primary purpose of dry detention pond is to capture and treat the runoff from the first inch of precipitation. As a result of the design, a secondary benefit is the attenuation of the post- development Stormwater runoff rates for the 1-year, 2-year, 10-year, and 100-year storm events.. The site is located in Wendell, North Carolina, with the boundary approximated by US 64 Bypass to the west, Poole Road to the south, Martin Pond Road to the east, and Knightdale-Eagle Rock Road to the north. The overall subdivision has proposed a mixture of 4000 units of single family and multifamily homes. In addition, approximately 250,000 square feet of commercial space is included in the proposed subdivision. The Town of Wendell has approved the Planned Unit Development. This report addresses the portion of the subdivision that exceeds 30% impervious. METHODOLOGY The Stormwater study was conducted using the natural drainage features as depicted by field surveys. Proposed drainage areas were based on field survey data and proposed development within the drainage areas. The scope of work included the following analyses: Hydrology ^ Simulation of the 1-year, 2-year, 10-year, and 100-year rainfall events for the Wendell area ^ Formulation of the 1-year, 2-year, 10-year, and 100-year flood hydrographs for the pre- and post-development drainage areas Hydraulic ^ Routing the 1-year, 2-year, 10-year, and 100-year flood hydrographs for pre- development runoff from the site. ^ Routing the 1-year, 2-year, 10-year, and 100-year flood hydrographs for post- development runoff through the proposed wet pond. The results of the hydrology calculations are used in the hydraulic analyses. The hydraulic design requires the development of astage-storage and stage-discharge function for the proposed impoundment. The rainfall/runoff hydrographs, stage-storage and stage-discharge functions have been compiled to create a routing computer simulation model using Haestad Methods PondPack v10.0 software. This PondPack model was then used to assess the peak water surface elevations for the design rainfall events. The PondPack modeling results are provided as appendices to this report. HYDROLOGY The SCS Method was used to develop runoff hydrographs for the 24-hour duration rainfall curves using the NOAA Atlas 14 rainfall data for Raleigh-Durham International Airport for the 2-year, 10- year, 50-year and 100-year storm events. This method requires three basic parameters: a curve number (CN), time of concentration (t~), and drainage area. Wendell Falls Subdivision i W&R Project 2o526i.oq Wendell Falls Parkway Stormwater Management Report September zoo? WENDELL FALLS SUBDIVISION WENDELL FALLS PARKWAY STORMWATER MANAGEMENT PLAN WENDELL, NORTH CAROLINA Curve numbers were based on soil type and land use. Soil types were delineated from the Soil Survey of Wake County, North Carolina (November 1970). Land use for existing conditions was based on the most recent Wake County aerial photographs and field observations. Post development land use is based on the proposed site plan. The curve numbers selected for the impervious and pervious areas are 98 and 73 respectively, for a composite curve number of 89.5, Times of concentration were calculated using methods described in the SCS publication "Urban Hydrology for Small Watersheds, TR-55" and based on Wake County topographic maps and field survey data. The post-development time of concentration was calculated for the drainage areas that are piped to the storage area based on the flow time through the piped drainage systems and small areas of sheet flow. Due to length of pipe, a time of concentration of 5 minutes (0.0833 hours) has been selected for the network. HYDRAULICS Computer simulated reservoir routing of the 1-year, 2-year, 10-year, and 100-year design storms utilized stage-storage and stage-discharge functions. Stage-storage functions were derived from the proposed grading of the wet pond. Anon-linear regression relation for surface area versus elevation was derived for the basin. This relation estimates the incremental volume of the basin to the stage or elevation of the basin. Stage-discharge functions were developed to size the proposed outlet structure. CONCLUSIONS Based on the routing study, the proposed constructed wetland ponds have sufficient volume to safely pass the 100-year storm. The outlet was designed to discharge the first inch of runoff through a separate outlet barrel. Larger storm events bypass the level spreader. Wendell Falls Subdivision 2 W&R Project zo526i.oq Wendell Falls Parkway Stormwater Management Report September Zoo? WENDELL FALLS SUBDIVISION WENDELL FALLS PARKWAY STORMWATER MANAGEMENT PLAN WENDELL, NORTH CAROLINA DRY DETENTION POND DESIGN SUMMARY PROPOSED CONSTRUCTED WETLANDS • Water Quality Volume = 14556 CF • Sediment Storage = 3.200 CF • 5' Circular Riser Crest = 258.60 • 2" diameter drawdown orifice ~ 257.00 • 30"diameter RCP outlet barrel • Top of dam = 261.00 Storm Event Peak Water Surface Elevation Freeboard Q~ak Outflow 1" Storm 258.60 2.40 ft 0.13 cfs 2-Year 259.36 1.67 ft 25.6 cfs 10-Year 259.49 1.51 ft 27.4 cfs 100-Year 259.63 1.37 ft 33.6 cfs Wendell Falls Subdivision 3 W&R Project zo526i.oq Wendell Falls Parkway Stormwater Management Report September 2007 DRY DETENTION POND/SITE OUTFLOW CALCULATIONS Wendell Falls Subdivision W&R Project zo526i.oq Wendell Falls Parkway Stormwater Management Report September zoo? Job File: K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\DRYPOND.PPW Rain Dir: K:\05\05-260\05261.09\Proj\Wendell Falls Parkway\ JOB TITLE Project Date: 9/14/2006 Project Engineer: Ken Jesneck, PE Project Title: Kitts Creek Phase lE Project Comments: S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 Table of Contents i ********************** MASTER SUMMARY ********************** Watershed....... Master Network Summary ............. 1.01 *************** NETWORK SUMMARIES (DETAILED) *************** Watershed....... 1 Executive Summary (Nodes) .......... 2.01 Watershed....... 10 Executive Summary (Nodes) .......... 2.02 Watershed....... 25 Executive Summary (Nodes) .......... 2.03 Watershed....... 100 Executive Summary (Nodes) .......... 2.04 ********************** RAINFALL DATA *********************** Distribution A.. 1 Synthetic Curve .................... 3.01 ******************** RUNOFF HYDROGRAPHS ******************** WENDELL FLS PWY 1 Unit Hyd. Summary .................. 4.01 WENDELL FLS PWY 10 Unit Hyd. Summary .................. 4.02 WENDELL FLS PWY 25 Unit Hyd. Summary .................. 4.03 WENDELL FLS PWY 100 Unit Hyd. Summary .................. 4.04 S/N: DOYXYWH3NLBE PondPack (10.00.015.00) 2:51 PM Withers & Ravenel 9/11/2007 Table of Contents 11 ******************** OUTLET STRUCTURES ********************* Outlet 1........ Outlet Input Data .................. 5.01 Composite Rating Curve ............. 5.05 S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 • • • • • • • • • • • • • • • • Type.... Master Network Summary Page 1.01 Name.... Watershed File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw MASTER DESIGN STORM SUMMARY Network Storm Collection: RDU NOAA 14 Desi Total Depth Return Event in ------------ 10 ------ 4.9800 25 5.9000 100 7.3700 1 1.4600 Rainfall Type Time-Depth Curve Time-Depth Curve Time-Depth Curve Synthetic Curve RNF ID RDU NOAA l0yr RDU NOAA 25yr RDU NOAA 100yr Distribution A MASTER NETWORK SUMMARY SCS Unit Hydrograph Method (*Node=Outfall; +Node=Diversion;) (Trun= HYG Truncation: Blank=None; L=Left; R=Rt; LR=Left&Rt) Return HYG Vol Node ID Type Event ac-ft Trun *OUT POST-SITE JCT 10 2.011 *OUT POST-SITE JCT 25 2.474 *OUT POST-SITE JCT 100 3.224 *OUT POST-SITE JCT 1 .330 POND 20 IN POND 10 2.015 POND 20 IN POND 25 2.478 POND 20 IN POND 100 3.228 POND 20 IN POND 1 .334 POND 20 OUT POND 10 2.011 POND 20 OUT POND 25 2.474 POND 20 OUT POND 100 3.224 POND 20 OUT POND 1 .330 Max Qpeak Qpeak Max WSEL Pond Storage hrs cfs ft ac-ft 12.2000 25.61 12.2000 27.37 12.2000 33.59 1.0000 .13 12.1000 36.39 12.1000 41.01 12.1000 46.74 .3000 7.82 12.2000 25.61 259.36 .567 12.2000 27.37 259.49 .610 12.2000 33.59 259.63 .659 1.0000 .13 258.60 .325 S/N: DOYXYWH3NLBE PondPack (10.00.015.00) 2:51 PM Withers & Ravenel 9/11/2007 Type.... Master Network Summary Page 1.02 Name.... Watershed File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw MASTER NETWORK SUMMARY SCS Unit Hydrograph Method (*Node=Outfall; +Node=Diversion;) (Trun= HYG Truncation: Blank=None; L=Left; R=Rt; LR=Left&Rt) Return HYG Vol Qpeak Qpeak Max WSEL Node ID Type Event ac-ft Trun hrs - -- cfs ft --- --- - --- - --------- WENDELL ---- FLS ---- PWY ---- AREA ------ 10 ---------- -- 2.015 ---- -- 12.1000 - - - - - 36.39 WENDELL FLS PWY AREA 25 2.478 12.1000 41.01 WENDELL FLS PWY AREA 100 3.228 12.1000 46.74 WENDELL FLS PWY AREA 1 .334 .3000 7.82 Max Pond Storage ac-ft S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Type.... Executive Summary (Nodes) Page 2.01 Name.... Watershed Event: 1 yr File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw Storm... Distribution A Tag: 1 NETWORK SUMMARY -- NODES (Trun.= HYG Truncation: Blank=None; L=Left; R=Rt; LR=Left & Rt) DEFAULT Design Storm File,ID = RDU NOAA 14 Desi Storm Tag Name = 1 Data Type, File, ID Storm Frequency Total Rainfall Depth Duration Multiplier Resulting Duration Resulting Start Time HYG Vol Qpeak Qpeak Max WSEL Node ID Type ac-ft Trun. hrs cfs ft ----------------- Outfall OUT POST-SITE ---- JCT --------- .330 - -- --------- 1.0000 -------- --------- .13 POND 20 IN POND .334 .3000 7.82 POND 20 OUT POND .330 1.0000 .13 258.60 WENDELL FLS PWY AREA .334 .3000 7.82 Synthetic Storm Distribution A 1 yr 1.4600 in 1 1.0000 hrs .0000 hrs Step= .0500 hrs End= 1.0000 hrs S/N: DOYXYWH3NLBE PondPack (10.00.015.00) 2:51 PM Withers & Ravenel 9/11/2007 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Type.... Executive Summary (Nodes) Page 2.02 Name.... Watershed Event: 10 yr File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw Storm... RDU NOAA l0yr Tag: 10 NETWORK SUMMARY -- NODES (Trun.= HYG Truncation: Blank=None; L=Left; R=Rt; LR=Left & Rt) DEFAULT Design Storm File,ID = RDU NOAA 14 Desi Storm Tag Name = 10 Data Type, File, ID = Time-Depth Curve RDU NOAA l0yr Storm Frequency = 10 yr Total Rainfall Depth= 4.9800 in Duration Multiplier = 1 Resulting Duration = 23.9904 hrs Resulting Start Time= .0000 hrs Step= .0833 hrs End= 23.9904 hrs HYG Vol Qpeak Qpeak Max WSEL Node ID Type ac-ft Trun. hrs cfs ft ---- --------- ----------------- Outfall OUT POST-SITE ---- JCT ---------- 2.011 -- --------- 12.2000 ---- 25.61 POND 20 IN POND 2.015 12.1000 36.39 POND 20 OUT POND 2.011 12.2000 25.61 259.36 WENDELL FLS PWY AREA 2.015 12.1000 36.39 S/N: DOYXYWH3NLBE PondPack (10.00.015.00) 2:51 PM Withers & Ravenel 9/11/2007 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Type.... Executive Summary (Nodes) Page 2.03 Name.... Watershed Event: 25 yr File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw Storm... RDU NOAA 25yr Tag: 25 NETWORK SUMMARY -- NODES (Trun.= HYG Truncation: Blank=None; L=Left; R=Rt; LR=Left & Rt) DEFAULT Design Storm File,ID = RDU NOAA 14 Desi Storm Tag Name = 25 Data Type, File, ID = Time-Depth Curve RDU NOAA 25yr Storm Frequency = 25 yr Total Rainfall Depth= 5.9000 in Duration Multiplier = 1 Resulting Duration = 23.9904 hrs Resulting Start Time= .0000 hrs Step= .0833 hrs End= 23.9904 hrs HYG Vol Qpeak Qpeak Max WSEL Node ID Type ac-ft Trun. hrs -- --------- cfs ft -------- --------- ----------------- Outfall OUT POST-SITE ---- JCT ---------- 2.474 12.2000 27.37 POND 20 IN POND 2.478 12.1000 41.01 POND 20 OUT POND 2.474 12.2000 27.37 259.49 WENDELL FLS PWY AREA 2.478 12.1000 41.01 S/N: DOYXYWH3NLBE PondPack (10.00.015.00) 2:51 PM Withers & Ravenel 9/11/2007 • • • • • • • • • • • • • • • • • • • • • • • • • • • • Type.... Executive Summary (Nodes) Page 2.04 Name.... Watershed Event: 100 yr File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw NETWORK SUMMARY -- NODES (Trun.= HYG Truncation: Blank=None; L=Left; R=Rt; LR=Left & Rt) DEFAULT Design Storm File,ID = RDU NOAA 14 Desi Storm Tag Name = 100 Data Type, File, ID = Time-Depth Curve RDU NOAA 100yr Storm Frequency = 100 yr Total Rainfall Depth= 7.3700 in Duration Multiplier = 1 Resulting Duration = 23.9990 hrs Resulting Start Time= .0000 hrs Step= .0833 hrs End= 23.9990 hrs HYG Vol Qpeak Qpeak Max WSEL Node ID - Type - - ac-ft - Trun. hrs cfs ft --------------- - Outfall OUT POST-SITE - - JCT --- ------ 3.224 -- --------- 12.2000 -------- --------- 33.59 POND 20 IN POND 3.228 12.1000 46.74 POND 20 OUT POND 3.224 12.2000 33.59 259.63 WENDELL FLS PWY AREA 3.228 12.1000 46.74 S/N: DOYXYWH3NLBE PondPack (10.00.015.00) 2:51 PM Withers & Ravenel 9/11/2007 Type.... Synthetic Curve Page 3.01 Name.... Distribution A Tag: 1 File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw CUMULATIVE RAINFALL FRACTIONS Time I Output Time increment = .0500 hrs hrs ~ Time on left represents time for first value in each row. .0000 I .000 .160 .330 .430 .520 .2500 I .600 .660 .710 .750 .790 .5000 I .820 .840 .860 .880 .900 .7500 I .920 .940 .960 .970 .980 1.0000 I 1.000 S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 Type.... Unit Hyd. Summary Page 4.01 Name.... WENDELL FLS PWY Tag: 1 Event: 1 yr File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw Storm... Distribution A Tag: 1 SCS UNIT HYDROGRAPH METHOD STORM EVENT: 1 year storm Duration = 1.0000 hrs Rain Depth = 1.4600 in Rain Dir = K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\ Rain File -ID = - Distribution A Unit Hyd Type = Default Curvilinear HYG Dir = K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\ HYG File - ID = work_pad.hyg - WENDELL FLS PWY 1 Tc (Min. Tc) _ .0833 hrs Drainage Area = 6.220 acres Runoff CN= 90 Computational Time Increment = .01111 hrs Computed Peak Time = .2666 hrs Computed Peak Flow = 8.25 cfs Time Increment for HYG File = .1000 hrs Peak Time, Interpolated Output = .3000 hrs Peak Flow, Interpolated Output = 7.82 cfs WARNING: The difference between calculated peak flow and interpolated peak flow is greater than 1.50% DRAINAGE AREA ID:WENDELL FLS PWY CN = 90 Area = 6.220 acres S = 1.1111 in 0.25 = .2222 in Cumulative Runoff ------------------- .6523 in .338 ac-ft HYG Volume... .334 ac-ft (area under HYG curve) ***** SCS UNIT HYDROGRAPH PARAMETERS ***** Time Concentration, Tc = .08330 hrs (ID: WENDELL FLS PWY) Computational Incr, Tm = .01111 hrs = 0. 20000 Tp Unit Hyd. Shape Fact or = 483.432 (37.46°s under rising limb) K = 483.43/645.333, K = .7491 (also, K = 2/(1+(Tr/Tp)) Receding/Rising, Tr/Tp = 1.6698 (solved from K = .7491) Unit peak, qp = 84.60 cfs Unit peak time Tp = .05553 hrs Unit receding limb, Tr = .22213 hrs Total unit time, Tb = .27767 hrs S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 Type.... Unit Hyd. Summary Page 4.02 Name.... WENDELL FLS PWY Tag: 10 Event: 10 yr File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw Storm... RDU NOAA 10yr Tag: 10 SCS UNIT HYDROGRAPH METHOD STORM EVENT: 10 year storm Duration = 23.9904 hrs Rain Depth = 4.9800 in Rain Dir = K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\ Rain File -ID = - RDU NOAA l0yr Unit Hyd Type = Default Curvilinear HYG Dir = K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\ HYG File - ID = work_pad.hyg - WENDELL FLS PWY 10 Tc (Min. Tc) _ .0833 hrs Drainage Area = 6.220 acres Runoff CN= 90 Computational Time Increment = .01111 hrs Computed Peak Time = 12.0952 hrs Computed Peak Flow = 36.59 cfs Time Increment for HYG File = .1000 hrs Peak Time, Interpolated Output = 12.1000 hrs Peak ---- Flow, ------ Interpolated ------------- Output = --------- 36.39 ---------- cfs -- DRAINAGE AREA ID:WENDELL FLS PWY CN = 90 Area = 6.220 acres S = 1.1111 in 0.2S = .2222 in Cumulative Runoff ------------------- 3.8570 in 1.999 ac-ft HYG Volume... 2.015 ac-ft (area under HYG curve) ***** SCS UNIT HYDROGRAPH PARAMETERS ***** Time Concentration, Tc = .08330 hrs (ID: WENDELL FLS PWY) Computational Incr, Tm = .01111 hrs = 0. 20000 Tp Unit Hyd. Shape Factor = 483.432 (37.46% under rising limb) K = 483.43/645.333, K = .7491 (also, K = 2/(1+(Tr/Tp)) Receding/Rising, Tr/Tp = 1.6698 (solved from K = .7491) Unit peak, qp = 84.60 cfs Unit peak time Tp = .05553 hrs Unit receding limb, Tr = .22213 hrs Total unit time, Tb = .27767 hrs S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 Type.... Unit Hyd. Summary Page 4.03 Name.... WENDELL FLS PWY Tag: 25 Event: 25 yr File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw Storm... RDU NOAA 25yr Tag: 25 SCS UNIT HYDROGRAPH METHOD STORM EVENT: 25 year storm Duration = 23.9904 hrs Rain Depth = 5.9000 in Rain Dir = K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\ Rain File -ID = - RDU NOAA 25yr Unit Hyd Type = Default Curvilinear HYG Dir = K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\ HYG File - ID = work_pad.hyg - WENDELL FLS PWY 25 Tc (Min. Tc) _ .0833 hrs Drainage Area = 6.220 acres Runoff CN= 90 -------------------------------------------- Computational Time Increment = .01111 hrs Computed Peak Time = 12.0952 hrs Computed Peak Flow = 41.26 cfs Time Increment for HYG File = .1000 hrs Peak Time, Interpolated Output = 12.1000 hrs Peak Flow, Interpolated Output = 41.01 cfs DRAINAGE AREA ID:WENDELL FLS PWY CN = 90 Area = 6.220 acres S = 1.1111 in 0.2S = .2222 in Cumulative Runoff ------------------- 4.7485 in 2.461 ac-ft HYG Volume... 2.478 ac-ft (area under HYG curve) ***** SCS UNIT HYDROGRAPH PARAMETERS ***** Time Concentration, Tc = .08330 hrs (ID: WENDELL FLS PWY) Computational Incr, Tm = .01111 hrs = 0. 20000 Tp Unit Hyd. Shape Factor = 483.432 (37.460 under rising limb) K = 483.43/645.333, K = .7491 (also, K = 2/(1+(Tr/Tp)) Receding/Rising, Tr/Tp = 1.6698 (solved from K = .7491) Unit peak, qp = 84.60 cfs Unit peak time Tp = .05553 hrs Unit receding limb, Tr = .22213 hrs Total unit time, Tb = .27767 hrs S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 Type.... Unit Hyd. Summary Page 4.09 Name.... WENDELL FLS PWY Tag: 100 Event: 100 yr File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw Storm... RDU NOAA 100yr Tag: 100 SCS UNIT HYDROGRAPH METHOD STORM EVENT: 100 year storm Duration = 23.9990 hrs Rain Depth = 7.3700 in Rain Dir = K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\ Rain File -ID = - RDU NOAA 100yr Unit Hyd Type = Default Curvilinear HYG Dir = K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\ HYG File - ID = work_pad.hyg - WENDELL FLS PWY 100 Tc (Min. Tc) _ .0833 hrs Drainage Area = 6.220 acres Runoff CN= 90 Computational Time Increment = .01111 hrs Computed Peak Time = 12.1063 hrs Computed Peak Flow = 46.75 cfs Time Increment for HYG File = .1000 hrs Peak Time, Interpolated Output = 12.1000 hrs Peak Flow, Interpolated Output = 46.74 cfs DRAINAGE AREA ID:WENDELL FLS PWY CN = 90 Area = 6.220 acres S = 1.1111 in 0.2S = .2222 in Cumulative Runoff ------------------- 6.1862 in 3.206 ac-ft HYG Volume... 3.228 ac-ft (area under HYG curve) ***** SCS UNIT HYDROGRAPH PARAMETERS ***** Time Concentration, Tc = .08330 hrs (ID: WENDELL FLS PWY) Computational Incr, Tm = .01111 hrs = 0.20000 Tp Unit Hyd. Shape Fact or = 483.432 (37.460 under rising limb) K = 483.43/695.333, K = .7491 (also, K = 2/(1+(Tr/Tp)) Receding/Rising, Tr/ Tp = 1.6698 (solved from K = .7491) Unit peak, qp = 84.60 cfs Unit peak time Tp = .05553 hrs Unit receding limb, Tr = .22213 hrs Total unit time, Tb = .27767 hrs S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 • • • • • • • • • • • • • • • • • • • • • • • • • • • • Type.... Outlet Input Data Name.... Outlet 1 Page 5.01 File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw REQUESTED POND WS ELEVATIONS: Min. Elev.= 257.00 ft Increment = .10 ft Max. Elev.= 261.00 ft OUTLET CONNECTIVITY ---> Forward Flow Only (Upstream to DnStream) <--- Reverse Flow Only (DnStream to Upstream) <---> Forward and Reverse Both Allowed Structure No. ---- Outfall ------- E1, ft --------- E2, ft --------- ----------------- Inlet Box RO ---> CO 258.600 261.000 Orifice-Circular 00 ---> CO 257.000 261.000 Culvert-Circular CO ---> TW 256.500 261.000 Weir-Rectangular WO ---> TW 259.500 261.000 TW SETUP, DS Channel S/N: DOYXYWH3NLBE PondPack (10.00.015.00) 2:51 PM Withers & Ravenel 9/11/2007 Type.... Outlet Input Data Name.... Outlet 1 Page 5.02 File.... K:\05\05-260\05261.04\Proj\wendell Falls Parkway\Drypond.ppw OUTLET STRUCTURE INPUT DATA Structure ID = RO Structure Type = Inlet Box -------------- ------------------- # of Openings = --- 1 Invert Elev. = 258.60 ft Orifice Area = 19.6350 sq.ft Orifice Coeff. _ .600 Weir Length = 15.71 ft Weir Coeff. = 2.800 K, Reverse = 1.000 Mannings n = .0000 Kev,Charged Riser = .000 Weir Submergence = No Structure ID = 00 Structure Type = Orifice-Circular ------------------------------------ # of Openings = 1 Invert Elev. = 257.00 ft Diameter = .1670 ft Orifice Coeff. _ .600 S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 • • • • • • • • • • • • • • • • • • • • • • • • • • Type.... Outlet Input Data Name.... Outlet 1 Page 5.03 File.... K:\05\05-260\05261.04\Proj\Wendell Falls Parkway\Drypond.ppw OUTLET STRUCTURE INPUT DATA Structure ID = CO Structure Type ------------------ = Culvert-Circular ------------------ No. Barrels = 1 Barrel Diameter = 2.5000 ft Upstream Invert = 256.50 ft Dnstream Invert = 256.00 ft Horiz. Length = 100.00 ft Barrel Length = 100.00 ft Barrel Slope = .00500 ft/ft OUTLET CONTROL DATA... Mannings n = .0130 Ke = .5000 Kb = .009217 Kr = .5000 HW Convergence = .001 (forward entrance loss) (per ft of full flow) (reverse entrance loss) +/- ft INLET CONTROL DATA... Equation form = 1 Inlet Control K = .0018 Inlet Control M = 2.0000 Inlet Control c = .02920 Inlet Control Y = .7400 T1 ratio (HW/D) = 1.060 T2 ratio (HW/D) = 1.205 Slope Factor = -.500 Use unsubmerged inlet control Form 1 equ. below T1 elev. Use submerged inlet control Form 1 equ. above T2 elev. In transition zone between unsubmerged and submerged inlet control, interpolate between flows at T1 & T2... At T1 Elev = 259.15 ft ---> Flow = 27.16 cfs At T2 El.ev = 259.51 ft ---> Flow = 31.05 cfs S/N: DOYXYWH3NLBE PondPack (10.00.015.00) 2:51 PM Withers & Ravenel 9/11/2007 Type.... Outlet Input Data Name.... Outlet 1 Page 5.04 File.... K:\05\05-260\05261.09\Proj\Wendell Falls Parkway\Drypond.ppw OUTLET STRUCTURE INPUT DATA Structure ID Structure Type -------------- # of Openings Crest Elev. Weir Length Weir Coeff. WO Weir-Rectangular ---------------- 1 259.50 ft 29.00 ft 3.100000 Weir TW effects (Use adjustment equation) Structure ID = TW Structure Type = TW SETUP, DS Channel ------------------------------------ FREE OUTFACE CONDITIONS SPECIFIED CONVERGENCE TOLERANCES... Maximum Iterations= 40 Min. TW tolerance = .01 ft Max. TW tolerance = .01 ft Min. HW tolerance = .01 ft Max. HW tolerance = .O1 ft Min. Q tolerance = .00 cfs Max. Q tolerance = .00 cfs S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 Type.... Composite Rating Curve Name.... Outlet 1 Page 5.05 File.... K:\05\05-260\05261.09\Proj\Wendell Falls Parkway\Drypond.ppw ***** COMPOSITE OUTFLOW SUMMARY **** WS Elev, Total Q Notes -------- -------- ------ -- Converge ---------- --- ------------ Elev. Q TW El ev Error ft cfs ft +/-ft ----- - Contributing ------------- Structures ------------ -------- 257.00 ------- .00 ------ Free -- Outfall (no Q: RO,OO ,CO,WO) 257.10 .O1 Free Outfall OO,CO (no Q: RO,WO) 257.20 .04 Free Outfall OO,CO (no Q: RO,WO) 257.30 .05 Free Outfall OO,CO (no Q: RO,WO) 257.40 .06 Free Outfall OO,CO (no Q: RO,WO) 257.50 .07 Free Outfall OO,CO (no Q: RO,WO) 257.60 .08 Free Outfall OO,CO (no Q: RO,WO) 257.70 .08 Free Outfall OO,CO (no Q: RO,WO) 257.80 .09 Free Outfall OO,CO (no Q: RO,WO) 257.90 .10 Free Outfall OO,CO (no Q: RO,WO) 258.00 .10 Free Outfall OO,CO (no Q: RO,WO) 258.10 .11 Free Outfall OO,CO (no Q: RO,WO) 258.20 .11 Free Outfall OO,CO (no Q: RO,WO) 258.30 .12 Free Outfall OO,CO (no Q: RO,WO) 258.40 .12 Free Outfall OO,CO (no Q: RO,WO) 258.50 .13 Free Outfall OO,CO (no Q: RO,WO) 258.60 .13 Free Outfall OO,CO (no Q: RO,WO) 258.70 1.53 Free Outfall RO,OO,CO (no Q: WO) 258.80 4.05 Free Outfall RO,OO,CO (no Q: WO) 258.90 7.34 Free Outfall RO,OO,CO (no Q: WO) 259.00 11.21 Free Outfall RO,OO,CO (no Q: WO) 259.10 15.62 Free Outfall RO,OO,CO (no Q: WO) 259.20 20.49 Free Outfall RO,OO,CO (no Q: WO) 259.30 24.70 Free Outfall RO,CO (no Q: OO,WO) 259.40 26.15 Free Outfall RO,OO,CO (no Q: WO) 259.50 27.56 Free Outfall RO,CO (no Q: OO,WO) 259.60 31.76 Free Outfall RO,OO,CO,WO 259.70 38.29 Free Outfall RO,CO,WO (no Q: 00) 259.80 46.26 Free Outfall RO,CO,WO (no Q: 00) 259.90 55.41 Free Outfall RO,CO,WO (no Q: 00) 260.00 65.55 Free Outfall RO,CO,WO (no Q: 00) 260.10 76.57 Free Outfall RO,CO,WO (no Q: 00) 260.20 88.34 Free Outfall RO,CO,WO (no Q: 00) 260.30 100.77 Free Outfall RO,CO,WO (no Q: 00) 260.40 113.90 Free Outfall RO,CO,WO (no Q: 00) 260.50 127.75 Free Outfall RO,CO,WO (no Q: 00) 260.60 142.27 Free Outfall RO,CO,WO (no Q: 00) 260.70 157.43 Free Outfall RO,CO,WO (no Q: 00) S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 Type.... Composite Rating Curve Name.... Outlet 1 ***** COMPOSITE OUTFLOW SUMMARY **** WS Elev, Total Q Notes -------- -------- ------ -- Converge ------------- ------------ Elev. Q TW El ev Error ft cfs ft +/-ft Contributing ------------ Structures ------------ -------- 260.80 ------- 173.21 ------ Free -- ----- Outfall -- RO,CO,WO (no Q: 00) 260.90 189.57 Free Outfall RO,CO,WO (no Q: 00) 261.00 206.51 Free Outfall RO,CO,WO (no Q: 00) Page 5.06 S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 Appendix A Index of Starting Page Numbers for ID Names A-1 ----- D ----- Distribution A 1... 3.01 ----- O ----- Outlet 1... 5.01, 5.05 ----- W ----- Watershed... 1.01, 2.01, 2.02, 2.03, 2.04 WENDELL FLS PWY 1... 4.01, 4.02, 9.03, 4.04 S/N: DOYXYWH3NLBE Withers & Ravenel PondPack (10.00.015.00) 2:51 PM 9/11/2007 BMP SIZING CALCULATIONS Wendell Falls Subdivision W&R Project zo5z6i.o4 Wendell falls Parkway Stormwater Management Report September zoo? Project Name: Wendell Falls Parkway Dry Pond City/State: WENDELL, NC Total Drainage Area = Impervious Surfaces = Undisturbed & Managed Open Space = Impervious Surface Area = 6.22 ac 4.11 ac 2.11 ac 66.1 Proiect #: 205261.04 Date: 11-Sep-07 1-Inch Runoff Volume Calculation Using the runoff volume calculations in the "Simple Method" as described by Schueler (1987) Rv = 0.05 + 0.009(1) where, Rv =Runoff coefficient, in./in. I =Percent impervious Rv = 0.64 in./in. Total runoff volume from 1-inch precipitation: Runoff volume, S = (Design rainfall) (Rv) (Drainage Area) S = 0.334 acre-ft 14556 cu. ft. Proposed orifice elevation = 257 feet Runoff storage provided = 0.335 ac-ft BMP Sizing.xls -Dry Detention Pond 9/11 /2007 Project Name: Wendell Falls Parkway City/State: Raleigh, NC STORMWATER BMP -Dry Pond Orifice Calculator Variables WQ Volume: Head: Draw down time: Orifice Area = 0.013461 sq. ft Orifice Diameter = 1.570991 in 0.334 Acre-ft 14549.04 cf 1.5 ft 0.75 ft 72 hrs 259200 s 1.938372 sq. in Project #: 205261.04 Date: 11-Sep-07 Constants g = 32.2 ft/s2 Cd= 0.6 USE 2.0" DIAMETER ORIFICE FLOTATION AND ANTI- SEEP CALCULATIONS Wendell Falls Subdivision W&R Project zo5z6i.oq Wendell Falls Parkway Stormwater Management Report September zoo? Flotation Calculations Project No: 02050261.01 Calc. By: KLJ Project Name: Wendell Falls -Dry Detention Pond Date: September, 2007 Com oncnts 1'VeighLs Wgt. HZO Wgt.Concrete Wgt. Soil (Sat) (Ibs/cu. ft.) (Ibs/cu. ft.) (Ibs/cu. ft.) 62.40 150.00 120.00 Outlet Stru~ ure Base Diameter Thickness (ft) (i n) 0.00 0.00 Walls Diameter Wall Height (ft) (ft) Outside 5.83 2.10 Inside 5.00 Fillet Volume (cu. ft) 0.00 Weight of Wetwell = (Outside Volume -Inside Volume + Fillet Volume) x Weight of Concrete Walls Base Fillet Total Weight 2,232.51 0.00 0.00 2,232.51 (Ibs) 5oi I Soil Weight =((Base Area -Wetwell OD Area) x Height of Soil) x Weight of Soil Total Height 0.50 (ft) Weight -1,603.34 (Ibs) Withers and Ravenel, Inc. Page 1 of 2 Flotation Calculations Project No: 02050261.01 Calc. By: KLJ Project Name: Wendell Falls - D Detention Pond Date: Se tember, 2007 Bottom Slab Circular Diameter Thickness (ft) (i n) Total 0.00 0.00 0.00 (Ibs) Rectangular Width of slab Length of slab Thickness (ft) (ft) (in) Total 6.50 6.50 12.00 6,337.50 (Ibs) Hatch O enin, s Circular Diameter (i n) Total 1 0.00 (Ibs) 2 0.00 (Ibs) 3 0.00 (Ibs) Rectangular Length Width (in) (in) Total 1 0.00 0.00 0.00 (Ibs) 2 0.00 (Ibs) 3 0.00 (Ibs) U ward r?~ctin ~ Force Upward Force Acting on Bottom of Structure =Base Area x Height of Water x Weight of Water Total Height 3.10 ( ft) Buoyancy Force 5,169.16 ( Ibs) Factor of Safet ~.,; :; Factor of Safety =Downward Force of Structure and Soil/Upward Force of Water Total Downward Force 6,966.68 (Ibs) Total Buoyancy Force 5,169.16 (Ibs) Factor of Safet = 1.35 Withers and Ravenel, Inc. Page 2 of 2 ~~ ", • ~ `~ ~~ -: ,. Desi¢nine Anti-Seep Collars (Refer to Detail 13) 1. Determine the length of pipe within the saturation zone of the embankment (Ls) either graphically or by using the following equation, ..assuming that. the upstream slope of the embankment intersects the invert of the pipe at.its .upstream end and that the slope of the pipe (S,) is constant. Ls = Y Z+4 (1-4 So) 2. Determine the vertical projection (P,) required to`increase L, by 15% either graphically as shown on G10-22 or by using the equation: P, = 0.075 Lt 3. Choose the actual vertical projection (2' minimum) of each anti-seep collar (P) by rounding up P, or rounding down P, and using multiple-collars. 4. Determine the number of anti-seep collars (N) required of the chosen vertical projection (P) using equation: P, = N. P 5. Either roundup N or repeat steps 3 and 4 to determineoptimum-PIN relationship. 6. Provide construction specifications relative to the materials. to be used and method for anchoring the anti-seep collar(s) to the pipe in a water tight manner. 7. Anti-seep collar spacing shall .be between 5 and 14 times the vertical projection of each collar. 8. Anti-seep collar dimensions shall extend :a ,minimum of 2 feet in all directions around the pipe. 9. Anti-seep collars shall be placed a minimum of two .feet from pipe joints. 10. Anti-seep collars should be placed within the saturation zone. In cases where the spacing limit will not allow this, at least one collar shall be placed in the saturation zone. C-10-21 1994 t • • rj • • • • • • • • • • • • • • • • ~~ • • • • • • • • • • • • • • • • •} •- • • • • DETAIL 13 - ANTI~EEP COLLAR DESIGN RISER CREST Y/,t~~!/,A~'/,A _ ~, - _ = ASSUMED ~ PHREATIC EMBANKMENT LINE Y ~'~ \ P ~ 9•~ -------------------------- S EMBANKMENT ~ o INVERT INTERSECTION Ls PIPE DIAMETER WILL VARY ANTI-SEEP COLLAR DESIGN where: p= vertical projection of anti-seep collar(ft). Ls = length of pipe in the saturated zone (ft.) y= distance in feet from upstream invert of pipe to highest normal water level expected to occur during the life of the structure. usually the top of the riser. 2= slope of upstream embankment as a ratio of z ft. horizontal to one ft. vertical. so= slope of pipe in feet per foot. This procedure is based on the phreatic line as shown in the drawing above: II.3. DEPARTMENT OF AGRICULTURE PAGE MARYLAND DEPABZMEN'P OF ENVIRONMENT SOII. CONSERVATION SERVICE C - 10 - 23 WATER MANAGEl1l~NT ADMIN89TSATION • • • i • • 200 ISO u N J 100 v 0 0 N ~ 0 Table 16 ANTI -SEEP COLLAR DESIGN C-10-22 fbw pOth. ~I ~f ) 10 9 8 ;, N_ T v N O 6 c U s N 4 ~c Q 3 2 1 1994 OPERATION AND MAINTENANCE AGREEMENTS Wendell Falls Subdivision W&R Project zo5z6i.oq Wendell Falls Parkway Stormwater Management Report September zoo? ~ WENDELL FALLS SUBDIVISION • DRY DETENTION POND OPERATION AND MAINTENANCE AGREEMENT i • The dry detention basin system is defined as the dry detention basin, pre-treatment including forebays and the • vegetated filter if one is provided. Maintenance activities shall be performed as follows: 1. After every significant runoff producing rainfall event and at least monthly: • a. Inspect the dry detention basin system for sediment accumulation, erosion, trash accumulation, vegetated cover, and general condition. b. Check and clear the orifice on the skimmer of any obstructions such that drawdown of the temporary • pool occurs within 2 to 5 days as designed. ~ 2. Repair eroded areas immediately, re-seed as necessary to maintain good vegetative cover, mow • vegetative cover to maintain a maximum height of six inches, and remove trash as needed. 3. Inspect and repair the collection system (i.e. catch basins, piping, swales, riprap, etc.) quarterly to • maintain proper functioning. 4. Remove accumulated sediment from the dry detention basin system semi-annually or when depth is reduced to 75% of the original design depth (see diagram below). Removed sediment shall be disposed • of in an appropriate manner and shall be handled in a manner that will not adversely impact water quality (i.e. stockpiling near a detention basin or stream, etc.). • The measuring device used to determine the sediment elevation shall be such that it will give an accurate depth reading. • When the sediment depth reads 0.75 feet in the main pond, the sediment shall be removed. When the sediment depth reads 0.75 feet in the forebay, the sediment shall be removed. BASIN DIAGRAM Top of Dam Elevation 261.0 ft Sediment emoval EI. 257.7 7 -------------- -- Sediment Removal Elevation 257.75 ft 75% ---------------------------------1---~-~---~-~-- ------ Bottom E vation 257.0 5% i o FOREBAY MAIN POND • Page 1 of 2 5. Remove cattails and other indigenous wetland plants when they cover 50% of the basin surface. These plants shall be encouraged to grow along the vegetated shelf and forebay berm. [For wetlands: Wetland planting densities in the marsh areas should be maintained by replanting bare areas as needed. Wetland plants should be encouraged to grow in the marsh areas.] 6. If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain shall be minimized to the maximum extent practical. 7. All components of the wet [wetland] detention basin system shall be maintained in good working order. 8. Level spreaders or other structures that provide diffuse flow shall be maintained every six months. All accumulated sediment and debris shall be removed from the structure, and a level elevation shall be maintained across the entire flow spreading structure. Any down gradient erosion must be repaired and/or replanted as necessary. I acknowledge and agree by my signature below that I am responsible for the performance of the seven maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print name: ~?:E~ ,dS+ n1 Title: /Ll~iw4Gc~l~ Address:_ SGG'o S~jc- ~o~_~it~L'~71~L Phone: 9/9 - ECG ~s"1A~ > > Signature: Date: Note: The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the pre ident. 1, ~tt~.iss ~ JA J r • a Notary Public for the State of ~'rn ~~'~' County of Wl~-~ , do hereby certify that ~ ~~US~a{ ' personally appeared before me this ~ day of 7.t ,and acknowledge the due execution of the forgoing wet (wetland] detention basin maintenance requirements. Witness my hand and official seal, ~~ ~~ *,. ~ *~ J ~~• ~:.F COVN~ My commission ~~. ?~j Page 2 of 2 WORKSHEETS Wendell Falls Subdivision W&R Project zo5z6i.oq Wendell Falls Parkway Stormwater Management Report September 2007 DIVISION OF WATER QUALITY -LEVEL SPREADER WORKSHEET (1/2007) • I. PROJECT INFORMATION (please complete the following information): Project Name : Wendell Falls Parkway Contact Person: Ken Jesneck. PE Phone Number: X919 1467-~s4o • Level Spreader ID: Out 3 i Level Spreader Length g ft. (perpendicular to flow) Drainage Area 6.22 ac. (on-site and off-site drainage to the level spreader) Impervious Area 4.11 ac. (on-site and off-site drainage to the level spreader) Forebay Area 54o cu ft. (0.2% of the contributing impervious surface area) Maximum Filter Strip/Buffer Slope 5.5 % (6% for forested/leaf littler cover, 8% for grass/thick cover) Max. Discharge from 1°/Hr Storm 0.13 cfs Max. Discharge to Level Spreader 0.13 cfs (Discharge rate from extended detention wetland or pond) Filter Strip/ Zone 1 Buffer Vegetation Forested (Grass/Thick ground cover or Forested) Filter Strip/ Zone 1 Buffer Width 30 ft. Filter Strip/ Zone 2 Buffer Vegetation Grass Filter Strip/ Zone 2 Buffer Width 20 ft. Bypass Method Used Dro Detention Etc Please include a worksheet for this. II. REQUIRED ITEMS CHECKLIST Initial in the space provided to indicate the following design requirements have been met and supporting documentation is attached. If a requirement has not been met, please explain why. At a minimum, a complete stormwater management plan submittal includes a worksheet for each BMP, design calculations, plans and specifications showing all BMPs and outlet structure details, a detailed drainage plan and a fully executed operation and maintenance agreement. An incomplete submittal package will result in a request for additional information and will substantially delay final review and approval of the project. Applicants Initials KLJ Project Site was visited prior to designing level spreader system. KLJ Date of the Site visit. Please attach time-dated digital photos of existing buffer conditions. KLJ Level spreader length is at least: 13 ft. per cfs for thick ground cover /grass; OR 65 ft per cfs for 50- foot canopied forest with leaf litter; 50 ft per cfs for 100-foot forested buffer; 40 ft. per cfs for 150-foot forested buffer; OR a weighted average of the two vegetation types within the buffer/filter strip). KLJ All ground cover types and their widths have been labeled on the construction plans. KLJ All contours have been depicted on the construction plans. KLJ No structures are located in protected buffers (must meet no practical alternatives criteria). KLJ No draws are located in the buffer or filter strip in the vicinity of the proposed level spreader. KLJ Construction details for the level spreader have been provided. KLJ The operation and maintenance agreement signed and notarized by the responsible party is provided. N/A No practical alternatives explanation + Variance request. (Level Spreaders in Series only). Bypass method used: Dry Detention Bypass conveyance method is specified and construction details and calculations are provided. N/A Alternative design option is specified and plan details and calculations are provided. KLJ Discharge to level spreader and subsequent filter strip is hydraulically and spatially separate from the bypass discharge. KLJ Construction details for the bypass and outlets are provided. Project No. DIVISION OF WATER QUALITY 401 EXTENDED DRY DETENTION BASIN WORKSHEET DWQ Stormwater Management Plan Review: At a minimum, a complete sormwater management plan submittal includes a worksheet for each BMP, design calculations, plans and specifications showing all BMPs and outlet structure details, a detailed drainage plan and a fully executed operation and maintenance agreement. An incomplete submittal package will result in a request for additional information and will substantially delay final review and approval of the project I. PROJECT INFORMATION (please complete the following information): Project Name : Wendell Falls Parkway Contact Person: Ken Jesneck, PE Phone Number: j919 ) 467-3340 For projects with multiple basins, specify which basin this worksheet applies to:_ Drainage Area: s.zz acres Percent Impervious Area: 66_~ II. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices Manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate the following design requirements have been met and supporting documentation is attached. /f a requirement has not been met, attach an explanation of why. A licants Initials Either capture runoff from 1 yr., 24 hour storm and release over a 48 hour period, or capture runoff from 1 inch storm and draw down over a period of 2 to 5 days. Please provide routing for 1 yr. 24 hr. event or volume from 1 inch rain 1 ~ ~ S~• 1'T 3 The basin length to width ratio is greater than 3:1. The basin side slopes are no steeper than 3:1. A small permanent pool at outlet orifice is provided to reduce clogging. An emergency drain to completely empty the basin is provided. Vegetation plan prepared is specified on plans. Basin to be stabilized within 14 days of construction is specified. Sediment storage (20% of detention volume) in addition to detention volume is provided. Inlet and outlet erosion control measures to prevent scour are provided. Additional treatment to meet the 85% TSS removal efficiency is provided. Access for clean-out and maintenance is provided. Inlet plunge pool or other energy dissipation is provided. Forebay is provided to capture sediment and minimize clean-out problems. Uncompacted natural soils are utilized to promote vegetation and reduce sedimentation. Seasonal high water table is at least 1 foot below bottom of basin. If used as a temporary sediment basin, plans indicate clean-out prior to final operation. A site specific operation and maintenance plan with the following provisions is provided. The 0&M agreement is signed by the responsible party and notarized.