Loading...
HomeMy WebLinkAboutSW3220304_Plansheet C-800 - Misc. Detail_20220629O 8" ADS N-12 COMPATIBLE PAVEMENT W SLABRETE BASIN W PER PLAN ADAPTOR W/ SCREW TYPE SIZE (MIN.) CLEANOUT PLUG BUILDING FACE 8" MIN. ____ _"_"- 15" 4' -0" PVC OR HDPE DRAIN 16" MIN. 18" 4'-6" 3"X4" PIPE; SIZE AND 24" 5'-0" DOWNSPOUT MATERIAL AS SPECIFIED 30" 6'-0" ON SCHEDULE 2'-6" CURB AND 8" ADS N-12 PIPE SEAL AROUND - - - 8" MIN. GUTTER WITH (LENGTH AS REQUIRED TO JOINT DRAIN BASIN WITH H-25 RATED CURB OPENINGS SECTION AT CURB MATCH FINISH GRADE ) CAST-IRON BACKFILL MATERIAL SHALL BE CRUSHED STONE STD. PATTERN DUCTILE IRON PER PLAN SECTION AT DOWNSPOUT OR GRAVEL MATERIAL MEETING CLASS 1 OR 2 LASS 1 GRATE OR SOLID LID; SIZE AND CONC. PAVING CURB CUT ADAPTER AS SPECIFIED IN ASTM D2321. B TYPE AS SPECIFIED ON SCHEDULE SHALLBE PLACED UNIFORMLY IN PER DETAIL 11/C-801 2� 4.5' MIN 4.5' MIN MATERIALFTS AND SHOULDE (SEE PLAN) 2' (MIN.) (SEE PLAN) 2' (MIN.) �f CLEANOUT TYPICAL INSTALLATION IN PAVEMENT AREAS DRAIN BASIN WITH DUCTILE MIN. 6" WIDE BY 4" THK. �s;;,,;,;. •- - ••"'••�'.�;::•: «''' `' ^'-- - ---- - t° "'':•••'•,':'°':::'-''.::•:::;:•::..`'.riti:r•:e..:.����..:�.::�. '' + ` '' `• • •:` `:'..� X/�X//�/NN /N//X//�/�//�//� •� \, • /��/��%�%//� /� ADS N-12 45' BEND 1-3/8" FINISHED GRADE IRON GRATE OR SOLID LID; CONC. PAD TO BE SIZE AND TYPE AS FORMED AROUND DRAIN SPECIFIED ON SCHEDULE BASIN FRAME. z z 3 1 1 11 MAX ADS N-12 "D" x 8" 3 3 REDUCING WYE COMPACTED ABC PVC BODY PERMANENT GRASS WATERTIGHT ADAPTORS LINING PER SEEDING SPECIFICATIONS, 90° BEND FOR USE WITH ALL PVC OR HDPE DRAIN PLASTIC PIPING SYSTEMS SHEET C-700, TYP. o ADS N-12 END CAP PIPE; SIZE AND ELEVATION PLAN MATERIAL AS SPECIFIED ON SCHEDULE CROSS SECTION TYPICAL INSTALLATION IN YARD OR SIDEWALK AREAS NOTES: HEADER PIPE 8" PVC NOTES: 1. GRATES WITHIN LAWN AREAS TO BE 12" STANDARD PATTERN DUCTILE IRON. SIZE PER PLAN 1. THE DIAMETER OF THE PIPE "D" MAY VARY FROM 8" - 15" 2. GRATES WITHIN MULCHED PLANTING BEDS TO BE 12" DUCTILE IRON, ATRIUM STYLE. 3. GRATES WITHIN SIDEWALK AND PEDESTRIAN AREAS TO BE 12" ADA-COMPLIANT 2. ALL JOINTS SHALL BE WATER TIGHT DUCTILE IRON. 3. ADS N-12 PIPE AND APPURTENANCES MAY BE SUBSTITUTED 4. AREA DRAINS SHALL BE FURNISHED WITHOUT SUMP, ELSE SUMP SHALL BE FILLED WITH LIKE HIGH DENSITY POLYETHLENE PIPE OR PVC PRODUCTS WITH LEAN CONCRETE. TYPICAL SECTION AT DRIVEWAY N.T.S. 20 STORM DRAIN CLEANOUT N.T.S. 12 ROOF DRAIN DETAIL W/ CLEANOUT N.T.S. $ AREA DRAIN N.T.S. 4 NOTES: 1. A STABILIZED ENTRANCE PAD OF 2"-3" WASHED STONE OR RAIL ROAD BALLAST SHALL BE LOCATED WHERE CLEANOUT COVER ASSEMBLY, 4" THK., 3000 PSI CAST IRON FRAME WITH BOLTED CONC. PAD TO BE FORMED OR THREADED, SOLID LID SET AROUND CLEANOUT FRAME. TRAFFIC WILL ENTER OR LEAVE THE CONSTRUCTION SITE ONTO A PUBLIC STREET. FLUSH IN A CONCRETE BORDER. 2. FILTER FABRIC OR COMPACTED CRUSHER RUN STONE SHALL BE USED AS A BASE FOR THE CONSTRUCTION ENTRANCE. 4» 6 0' END OF CURB 3 THE ENTRANCE SHALL BE IN A N H WILL PPE TTOPKDRESING OSINGLWITHGOF SEDIMENT THIS AYCREQUIRE IODICREVENT ONTO PUBLIC STREETS OR EXIISTNIGEPAVEMENT.D ADDITIONAL R 20.0 STONE AS CONDITIONS WARRANT AND REPAIR OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. 4. ANY SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. - - - - _ "' _ _ ❑ ❑ ' , °• 5. WHEN APPROPRIATE, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING A PUBLIC STREET. WHEN _ _ -- i'- -� ❑ ❑ ❑ -ICI-ICI III-I�I- WASHING IS REQUIRED, IT SHALL BE DONE IN AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN �- ❑ ❑ ❑ ❑ APPROVED SEDIMENT BASIN SEE STD. NO. 30.11B. -III-I I I- -I = _ I-, ❑ 15' CLEANOUT RISER WITH r° ° v° THREADED PLUG 50' MIN. EDGE OF PAVEMENT PUBLIC STREET 3.0 EXISTING GROUND �M, SOIL STABILIZATION FABRIC PLAN TRANS. UNDER WASHED STONE TOP OF CURB 3.0 ' 50' MIN. � WYE FITTING _ w w z V) LATERAL DRAIN LINE SIZE AND SLOPE PER PLAN � U N m FLOW GUTTER _ _ _ _ _ CONCRETE OR CONCRETE BLOCK END OF CURB FLARE N.T.S. 19 STABILIZED CONSTRUCTION ENTRANCE N.T.S. 11 TYPICAL CLEANOUT - SANITARY SEWER N.T.S. 3 2 W 1 1114 La GRATE HOOD #5 WASHED STONE 2/3Do 0.00% SLOPE --- M M 1" REBAR FOR BAG REMOVAL GRATE FROM INLET l 1 I / O4 \ x DEFLECTOR cc\ ° NON -WOVEN FILTER PROFILE E o° ° �o 00` �- SECTION A -A FABRIC UNDER STONE ° °o A\ A v Ad oo O. _ o_o_ O FILTER BAG A EXPANSION ' ° o o ° DUMP LOOPS RESTRAINT =4: STORAGE AREA �/ 00 0 \ _J o p + d. va C 0 0°00 �j O 7 Q M O CATCH BASIN � CATCH BASIN ,; :• eA: I 1 #5 WASHED STONE PLAN VIEW NOTES: • a a ' a 'a.v OUTLET ; ; ,°•': ° • a:a A- F\_w z 1. SEE TABLE BELOW FOR RIPRAP SIZE, LENGTH, WIDTH AND DEPTH OF APRON. .• v a :. •A �� d e 12 MI r 2. RIPRAP SHOULD EXTEND UP BOTH SIDES OF THE APRON AND AROUND THE END OF THE PIPE OR CULVERT �'a; AT THE DISCHARGE OUTLET AT A MAXIMUM SLOPE OF 2:1 AND A HEIGHT NOT LESS THAN TWO THIRDS THE PIPE DIAMETER OR CULVERT HEIGHT. 3. THERE SHALL BE NO OVERFLOW FROM THE END OF THE APRON TO THE SURFACE OF THE RECEIVING INSTALLATION SECTION VIEW-4 CHANNEL. THE AREA TO BE PAVED OR RIPRAPPED SHALL BE UNDERCUT SO THAT THE INVERT OF THE NOTES: APRON SHALL BE AT THE SAME GRADE (FLUSH) WITH THE SURFACE OF THE RECEIVING CHANNEL. 4. THE WIDTH OF THE END OF THE APRON SHALL BE EQUAL TO THE BOTTOM WIDTH OF THE RECEIVING 1. INLET MAINTENANCE SHALL BE DOCUMENTED IN PROJECT LOG BOOK. CHANNEL. MAXIMUM TAPER TO TO RECEIVING CHANNEL 5:1 NOTES: SECTION A -A 2. FILTER TYPES SHALL BE APPROVED BY THE SITE INSPECTOR PRIOR TO INSTALLATION. 5. ALL SUBGRADE FOR STRUCTURE TO BE COMPACTED TO 95% OR GREATER. 1. SEDIMENT SHALL BE REMOVED AND TRAP RESTORED TO ITS ORIGINAL DIMENSIONS WHEN 6. THE PLACING OF FILL, EITHER LOOSE OR COMPACTED IN THE RECEIVING CHANNEL SHALL NOT BE ALLOWED. 3. FILTER BAGS MAY BE REMOVED WHEN SITE IS STABILIZED AT THE SEDIMENT HAS ACCUMULATED TO 1/2 THE DESIGN DEPTH OF THE TRAP. THE DIRECTION OF THE EROSION CONTROL INSPECTOR. 2. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA AND IN SUCH A 7. NO BENDS OR CURVES IN THE HORIZONTAL ALIGNMENT OF THE APRON WILL BE PERMITTED. MANNER THAT IT WILL NOT ERODE. 4. FILTER BAGS SHALL BE REMOVED PRIOR TO STREET ACCEPTANCE. 3. THE STRUCTURE SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR Do - PIPE STRUCTURE DIAMETER Q10 TAILWATER LENGTH WIDTH d50/dmax DEPTH NCDOT 5. FILTER BAGS SHALL BE CLEANED OR REPLACED ON A REGULAR BASIS (NOT BE MORE HIS/HER AGENT AFTER EACH STORM EVENT AND REPAIRS MADE AS NECESSARY. (IN) (CFS) (FT.) (FT.) (FT.) (IN.) (IN.) CLASS 4. CONSTRUCTION OPERATIONS SHALL BE CARRIED OUT IN A SUCH A MANNER THAT THAN HALF FULL AT ANY TIME). EROSION AND WATER POLLUTION ARE MINIMIZED. HW-1 36 34 - 20 23 8/12 18 B 5. THE SEDIMENT TRAP SHALL BE REMOVED AND THE AREA STABILIZED WHEN THE 6. FILTER BAGS SHALL NOT BE ALLOWED IN EXISTING CITY OR STATE ROADS UNLESS DRAINAGE BASIN HAS BEEN PROPERLY STABILIZED. PRIOR APPROVAL IS GRANTED. 6. ON LARGER DRAINAGE AREAS RIP RAP MAY BE REQUIRED UNDER THE WASHED STONE. STANDARD RIP RAP APRON N.T.S. 18 CATCH BASIN INLET PROTECTION N.T.S. C10 STONE INLET SEDIMENT TRAP N.T.S. 2 SLOPE TRENCH SIDES SLOPE TRENCH SIDES 8.00' MAX. PER OSHA REQUIREMENTS PER OSHA REQUIREMENTS 2' MIN. VARIABLE AS DIRECTED BY THE ENGINEER TOP RIM OF DITCH 10 ga MIN. LINE WIRES WARNING SIGN PLASTIC OR ` STEEL POST SELECT ��'-�I�Ir WIRE TIES I FILL STEEP CUT OR FILL SLOPE - WARNING SIGN SELECT 2:1 SLOPE TREE PROTECTION AREA o I WIRE FABRIC INITIALFILL BACKFILL I MAX DO NOT ENTER MIN. 12-4 ga "� -0WOVEN 2" D 112" DrD D INTERMEDIATE I ORANGE, UV RESISTANT, WIRES HIGH - SILE MIN. 4" iD HAUNCHING BEDDING NOTE: CROSS SECTION A -A STABILIZE DIVERSION DITCH WITH TEMPORARY IICADESTRENGTH FABR C, TYP. I POLY BA R GRADE REQUIRED IF SEEDING AND EROSION CONTROL NETTING. TRENCHING IN ROCK RIGID PIPE FLEXIBLE PIPE O ORANGE, UV RESISTANT, o HIGH - TENSILE STRENGTH IN POLY BARRICADE FABRIC, TYP. N II INCLUDES REINFORCED INCLUDES CORRUGATED METAL, HDPE, UPSLOPE TOE POSITIVE GRADE 1.0% MAXIMUM CONCRETE AND PVC PIPE 3'-4" NOTES: 1. BEDDING SHALL BE CLASSI-A WORKED / FRONT ELEVATION VIEW FRONT SIDE VIEW 4 BY HAND. IF GROUNDWATER IS 6. SELECT BACKFILL NOT UNDER PAVED ANTICIPATED, THEN BEDDING SHALL BE AREAS CAN BE CLASS IV -A COMPACTED -- TREE PROTECTION AREA CLASS I-B COMPACTED TO 95% STD. TO 95% STD. PROCTOR. SIDE SLOPES TOP RIM OF DITCH N NOTES: PROCTOR. 7. ALL MATERIALS ARE CLASSIFIED IN 2:1 MAX I I I I I I I I-- DO NOT ENTER 2. HAUNCHING SHALL BE WORKED AROUND ACCORDANCE WITH THE LATEST EDITION 1. TREE PROTECTION FENCING MUST BE INSTALLED AT A MINIMUM RADIUS OF THE CRITICAL ROOT ZONE. - - THE PIPE BY HAND TO ELIMINATE VOIDS OF ASTM D 2321. 8. ALL MATERIALS SHALL BE INSTALLED IN \ 1 2. THE TREE PROTECTION FENCING MUST REMAIN IN PLACE FOR THE DURATION OF THE PROJECT. - AND SHALL BE CLASS 1-1 OR CLASS I-B OR CLASS II COMPACTED TO 95% MAXIMUM 8" LOOSE LIFTS IN - ZONA DE PROTECCION � PROCTOR. ACCORDANCE WITH ASTM D 698. CLASS 3. APPROVED IMPACT PROTECTION DEVICES MUST BE REMOVED AFTER CONSTRUCTION WHEN APPLICABLE. n 3. INITIAL BACKFILL SHALL BE CLASS I -A III AND IV -A MATERIALS SHALL BE STEEP CUT OR FILL SLOPE WORKED BY HAND, OR CLASS I-B OR COMPACTED NEAR OPTIMUM MOISTURE 4. SIGNS SHALL BE PLACED AT 50' MAXIMUM INTERVALS. PLACE A SIGN AT EACH END OF LINEAR TREE PARA ARBOLES - NO ENTRE CLASS 11 COMPACTED TO 95% STD. CONTENT. PROTECTION AND 50' ON CENTER FOR THE REMAINDER. PROCTOR. 9. FILL SALVAGED FROM EXCAVATION m m 4. INIITIAL BACKFILL NOT UNDER PAVED SHALL BE FREE OF DEBRIS, ORGANICS 5. FOR TREE PROTECTION AREAS LESS THAN 200' IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER AREAS CAN BE CLASS 11 COMPACTED TO AND ROCKS LARGER THAN 3". PROTECTED AREA. WARNING SIGN DETAIL 90% STANDARD PROCTOR. 10. ALL TRENCH EXCAVATIONS SHALL BE 5. SELECT BACKFILL SHALL BE CLASS I, 11, SLOPED, SHORED, SHEETED, BRACED OR O 6. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. PROVIDE WARNING LANGUAGE IN BOTH OR III COMPACTED TO 95% STD. OTHERWISE SUPPORTED IN COMPLIANCE PLAN VIEW ENGLISH AND SPANISH AS SHOWN PROCTOR WITH TOP 24" COMPACTED TO WITH OSHA REGULATIONS AND LOCAL 7. SIGNS ARE TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL WITH LETTERS A MINIMUM OF 3" HIGH, 100% STD. PROCTOR. ORDINANCES. CLEARLY LEGIBLE AND SPACED AS SHOWN. TRENCH DETAIL FOR STORM PIPES N.T.S.Cl TEMPORARY DIVERSION DITCH N.T.S. 9 TREE PROTECTION FENCE N.T.S. 1 ColeJenest & Stone Shaping the Environment Realizing the Possibilities Land Planning Landscape Architecture Civil Engineering Urban Design 200 South Tryon Street, Suite 1400 Charlotte, North Carolina 28202 p+ 704 376 1555 f+ 704 376 7851 url+ www.colejeneststone.com A.M. KING 1610 EAST MOREHEAD SUITE 200 CHARLOTTE, NC 28207 ALDI EAST SPENCER IN -BOUND TRAFFIC IMPROVEMENTS 1985 OLD UNION CHURCH ROAD EAST SPENCER, NC 28146 SITE DETAILS Project No. 4773 Issued 12/10/21 Revised 02/11/22 CLIENT REVISIONS 03/7/22 CLIENT REVISIONS 3/18/22 AGENCY COMMENTS 6/24/22 NCDEQ COMMENTS CID n F-1409 p C-596 =Q;' pTN CA?,o i ARO 25163 '1'f"un 111 u0'%%06 /24/22 O CM800 The drawings, the project manual and the design shown theron are instruments of Bolton & Menk Southeast, LLC.. The reproduction or unauthorized use of the documents without consent of Bolton & Menk Southeast, LLC. is prohibited. OBolton & Menk Southeast, LLC. 2021 C